Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
BMC Med Res Methodol ; 20(1): 256, 2020 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-33059590

RESUMO

BACKGROUND: Systematic reviews often require substantial resources, partially due to the large number of records identified during searching. Although artificial intelligence may not be ready to fully replace human reviewers, it may accelerate and reduce the screening burden. Using DistillerSR (May 2020 release), we evaluated the performance of the prioritization simulation tool to determine the reduction in screening burden and time savings. METHODS: Using a true recall @ 95%, response sets from 10 completed systematic reviews were used to evaluate: (i) the reduction of screening burden; (ii) the accuracy of the prioritization algorithm; and (iii) the hours saved when a modified screening approach was implemented. To account for variation in the simulations, and to introduce randomness (through shuffling the references), 10 simulations were run for each review. Means, standard deviations, medians and interquartile ranges (IQR) are presented. RESULTS: Among the 10 systematic reviews, using true recall @ 95% there was a median reduction in screening burden of 47.1% (IQR: 37.5 to 58.0%). A median of 41.2% (IQR: 33.4 to 46.9%) of the excluded records needed to be screened to achieve true recall @ 95%. The median title/abstract screening hours saved using a modified screening approach at a true recall @ 95% was 29.8 h (IQR: 28.1 to 74.7 h). This was increased to a median of 36 h (IQR: 32.2 to 79.7 h) when considering the time saved not retrieving and screening full texts of the remaining 5% of records not yet identified as included at title/abstract. Among the 100 simulations (10 simulations per review), none of these 5% of records were a final included study in the systematic review. The reduction in screening burden to achieve true recall @ 95% compared to @ 100% resulted in a reduced screening burden median of 40.6% (IQR: 38.3 to 54.2%). CONCLUSIONS: The prioritization tool in DistillerSR can reduce screening burden. A modified or stop screening approach once a true recall @ 95% is achieved appears to be a valid method for rapid reviews, and perhaps systematic reviews. This needs to be further evaluated in prospective reviews using the estimated recall.


Assuntos
Inteligência Artificial , Aprendizado de Máquina , Algoritmos , Humanos , Programas de Rastreamento , Estudos Prospectivos
2.
Acta Radiol Suppl ; 347: 217-22, 1976.
Artigo em Inglês | MEDLINE | ID: mdl-207097

RESUMO

The Neuroparallelogram, a radiographic system with an opposing tube-serial film changer provides for isoentric 2:1 magnification, stero radiography, a.p. or p.a. projections, more accurately positioned bi-plane angiography and the capacity for angiotomography. Angiographic examinations are expedited not only by the ease of set-up for different projections, but also by the capacity to accommodate for head rotation without repositioning the patient. The tube and film changer can be uncoupled so that routine films may be obtained. The improved detail of magnification radiography and the simplicity of positioning can also be used to perform routine skull radiography.


Assuntos
Angiografia Cerebral/instrumentação , Ampliação Radiográfica/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA