Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 523
Filtrar
1.
J Pharm Biomed Anal ; 156: 379-388, 2018 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-29783113

RESUMO

Human mistakes are still one of the main reasons of underlying regulatory affairs that in a compliance with FDA's Data Integrity and Analytical Quality by Design (AQbD) must be eliminated. To develop smooth, fast and robust methods that are free of human failures, a state-of-the-art automation was presented. For the scope of this study, a commercial software (DryLab) and a model mixture of 10 drugs were subjected to testing. Following AQbD-principles, the best available working point was selected and conformational experimental runs, i.e. the six worst cases of the conducted robustness calculation, were performed. Simulated results were found to be in excellent agreement with the experimental ones, proving the usefulness and effectiveness of an automated, software-assisted analytical method development.


Assuntos
Fracionamento Químico/métodos , Química Farmacêutica/métodos , Preparações Farmacêuticas/análise , Software , Cromatografia Líquida de Alta Pressão/métodos , Estudos de Viabilidade , Preparações Farmacêuticas/química
2.
J Chromatogr A ; 1232: 218-30, 2012 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-22226460

RESUMO

Robust HPLC separations lead to fewer analysis failures and better method transfer as well as providing an assurance of quality. This work presents the systematic development of an optimal, robust, fast UHPLC method for the simultaneous assay of two APIs of an eye drop sample and their impurities, in accordance with Quality by Design principles. Chromatography software is employed to effectively generate design spaces (Method Operable Design Regions), which are subsequently employed to determine the final method conditions and to evaluate robustness prior to validation.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Líquida de Alta Pressão/normas , Projetos de Pesquisa/normas , Software , Modelos Teóricos , Reprodutibilidade dos Testes , Interface Usuário-Computador
3.
J Pharm Biomed Anal ; 56(5): 874-9, 2011 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-21893394

RESUMO

The current article presents a novel approach to applying Quality by Design (QbD) principles to the development of high pressure reversed phase liquid chromatography (HPLC) methods. Four common critical parameters in HPLC--gradient time, temperature, pH of the aqueous eluent, and stationary phase--are evaluated within the Quality by Design framework by the means of computer modeling software and a column database, to a satisfactory degree. This work proposes the establishment of two mutually complimentary Design Spaces to fully depict a chromatographic method; one Column Design Space (CDS) and one Eluent Design Space (EDS) to describe the influence of the stationary phase and of the mobile phase on the separation selectivity, respectively. The merge of both Design Spaces into one is founded on the continuous nature of the mobile phase influence on retention and the great variety of the stationary phases available.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Concentração de Íons de Hidrogênio , Modelos Teóricos
11.
J Chromatogr A ; 1217(19): 3193-200, 2010 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-20189187

RESUMO

The present paper describes a multifactorial optimization of 4 critical HPLC method parameters, i.e. gradient time (t(G)), temperature (T), pH and ternary composition (B(1):B(2)) based on 36 experiments. The effect of these experimental variables on critical resolution and selectivity was carried out in such a way as to systematically vary all four factors simultaneously. The basic element is a gradient time-temperature (t(G)-T) plane, which is repeated at three different pH's of the eluent A and at three different ternary compositions of eluent B between methanol and acetonitrile. The so-defined volume enables the investigation of the critical resolution for a part of the Design Space of a given sample. Further improvement of the analysis time, with conservation of the previously optimized selectivity, was possible by reducing the gradient time and increasing the flow rate. Multidimensional robust regions were successfully defined and graphically depicted.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Acetonitrilas/química , Simulação por Computador , Concentração de Íons de Hidrogênio , Metanol/química , Modelos Teóricos , Reprodutibilidade dos Testes , Projetos de Pesquisa , Temperatura , Fatores de Tempo , Interface Usuário-Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA