Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Endocr Soc ; 8(6): bvae071, 2024 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-38721109

RESUMO

Background: Customized and standard automated insulin delivery (AID) systems for use in pregnancies of women with preexisting type 1 diabetes (T1D) are being developed and tested to achieve pregnancy appropriate continuous glucose monitoring (CGM) targets. Guidance on the use of CGM for treatment decisions during pregnancy in the United States is limited. Methods: Ten pregnant women with preexisting T1D participated in a trial evaluating at-home use of a pregnancy-specific AID system. Seven-point self-monitoring of blood glucose (SMBG) was compared to the closest sensor glucose (Dexcom G6 CGM) value biweekly to assess safety and reliability based on the 20%/20 mg/dL criteria. Results: All participants completed the study with 7 participants satisfying the safety and reliability criteria with a mean absolute relative difference of 10.3%. Three participants did not fulfill the criteria, mainly because the frequency of SMBG did not meet the requirements. Conclusion: Dexcom G6 CGM is safe and accurate in the real-world setting for use in pregnant women with preexisting T1D with reduced SMBG testing as part of a pregnancy-specific AID system.

2.
J Diabetes Complications ; 38(5): 108739, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38564971

RESUMO

BACKGROUND: Adults with type 1 diabetes (T1D) are considered at increased risk for cognitive impairment and accelerated brain aging. However, longitudinal data on cognitive impairment and dementia in this population are scarce. OBJECTIVE: To identify risk factors associated with cognitive performance and cognitive impairment in a longitudinal sample of older adults with T1D. METHODS: We analyzed data collected as part of the Wireless Innovation for Seniors with Diabetes Mellitus (WISDM) Study, in which 22 endocrinology practices participated. Randomized participants with T1D ≥60 years of age who completed at least one cognitive assessment were included in this study (n = 203). Cognitive impairment was classified using published recommendations. RESULTS: Older age, male sex, non-private health insurance, worse daily functioning, diagnosis of neuropathy, and longer duration of diabetes were associated with worse cognitive performance, but not cognitive impairment. 49 % and 39 % of the sample met criteria for cognitive impairment at baseline and 52 weeks respectively. Of the participants that had data at both time points, 10 % were normal at baseline and impaired at 52 weeks and 22 % of participants (44 % of those classified with cognitive impairment at baseline) reverted to normal over 52 weeks. CONCLUSION: This study indicated that several demographic and clinical characteristics are associated with worse cognitive performance in older adults with T1D, but there were no associations between these characteristics and cognitive impairment defined by NIH Toolbox cognitive impairment criteria. Caution is warranted when assessing cognition in older adults with T1D, as a large percentage of those identified as having cognitive impairment at baseline reverted to normal after 52 weeks. There is need for future studies on the interrelationship of cognition and aging to better understand the effects of T1D on cognitive health, to improve clinical monitoring and help mitigate the risk of dementia in this population.


Assuntos
Cognição , Disfunção Cognitiva , Diabetes Mellitus Tipo 1 , Humanos , Masculino , Diabetes Mellitus Tipo 1/complicações , Diabetes Mellitus Tipo 1/psicologia , Diabetes Mellitus Tipo 1/epidemiologia , Feminino , Idoso , Disfunção Cognitiva/epidemiologia , Disfunção Cognitiva/etiologia , Disfunção Cognitiva/diagnóstico , Fatores de Risco , Pessoa de Meia-Idade , Estudos Longitudinais , Cognição/fisiologia , Idoso de 80 Anos ou mais , Envelhecimento/fisiologia , Envelhecimento/psicologia
3.
Clin Transplant ; 38(1): e15212, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38041451

RESUMO

Pancreas transplantation alone (PTA) is a ß cell replacement option for selected patients with type 1 diabetes mellitus; concerns have been raised regarding deterioration in kidney function (KF) after PTA. This retrospective multicenter study assessed actual impact of transplantation and immunosuppression on KF in PTA recipients at three Transplant Centers. The primary composite endpoint 10 years after PTA was >50% eGFR decline, eGFR < 30 mL/min/1.73 m2 , and/or receiving a kidney transplant (KT). Overall, 822 PTA recipients met eligibility. Median baseline and 10-year eGFR (mL/min/1.73 m2 ) were 76.3 (58.1-100.8) and 51.3 (35.3-65.9), respectively. Primary composite endpoint occurred in 98 patients (53.5%) with 45 experiencing a >50% decrease in eGFR by 10 years post-transplant, 38 eGFR < 30 mL/min/1.73 m2 and 49 requiring KT. KF declined most significantly within 6 months post-PTA, more often in females and patients with better preserved GFR up to 5 years with 11.6% kidney failure at 10 years. Patient survival and death-censored graft survival were both 68% at 10 years with overall graft thrombosis rate 8%. KF declined initially after PTA but stabilized with further slow progression. In conclusion, prospective intervention studies are needed to test renal sparing interventions while gathering more granular data.


Assuntos
Diabetes Mellitus Tipo 1 , Transplante de Pâncreas , Feminino , Humanos , Estudos de Coortes , Diabetes Mellitus Tipo 1/cirurgia , Sobrevivência de Enxerto , Rim , Transplante de Pâncreas/efeitos adversos , Estudos Retrospectivos
4.
Diabetes Care ; 46(7): 1425-1431, 2023 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-37196353

RESUMO

OBJECTIVE: There are no commercially available hybrid closed-loop insulin delivery systems customized to achieve pregnancy-specific glucose targets in the U.S. This study aimed to evaluate the feasibility and performance of at-home use of a zone model predictive controller-based closed-loop insulin delivery system customized for pregnancies complicated by type 1 diabetes (CLC-P). RESEARCH DESIGN AND METHODS: Pregnant women with type 1 diabetes using insulin pumps were enrolled in the second or early third trimester. After study sensor wear collecting run-in data on personal pump therapy and 2 days of supervised training, participants used CLC-P targeting 80-110 mg/dL during the day and 80-100 mg/dL overnight running on an unlocked smartphone at home. Meals and activities were unrestricted throughout the trial. The primary outcome was the continuous glucose monitoring percentage of time in the target range 63-140 mg/dL versus run-in. RESULTS: Ten participants (HbA1c 5.8 ± 0.6%) used the system from mean gestational age of 23.7 ± 3.5 weeks. Mean percentage time in range increased 14.1 percentage points, equivalent to 3.4 h per day, compared with run-in (run-in 64.5 ± 16.3% versus CLC-P 78.6 ± 9.2%; P = 0.002). During CLC-P use, there was significant decrease in both time over 140 mg/dL (P = 0.033) and the hypoglycemic ranges of less than 63 mg/dL and 54 mg/dL (P = 0.037 for both). Nine participants exceeded consensus goals of above 70% time in range during CLC-P use. CONCLUSIONS: The results show that the extended use of CLC-P at home until delivery is feasible. Larger, randomized studies are needed to further evaluate system efficacy and pregnancy outcomes.


Assuntos
Diabetes Mellitus Tipo 1 , Humanos , Feminino , Gravidez , Lactente , Diabetes Mellitus Tipo 1/tratamento farmacológico , Insulina/uso terapêutico , Glicemia , Automonitorização da Glicemia/métodos , Sistemas de Infusão de Insulina , Estudos Cross-Over , Hipoglicemiantes/uso terapêutico , Resultado da Gravidez , Insulina Regular Humana/uso terapêutico
5.
Mayo Clin Proc ; 98(5): 748-749, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37137645
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA