Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Intervalo de ano de publicação
1.
Front Neurol ; 15: 1360335, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38606280

RESUMO

Introduction and purpose: Basilar artery occlusion (BAO) is still one of the most devastating neurological conditions associated with high morbidity and mortality. In the present study, we aimed to assess the role of posterior circulation collaterals as predictors of outcome in the BASICS trial and to compare two grading systems (BATMAN score and PC-CS) in terms of prognostic value. Methods: We performed a sub-analysis of the BASICS trial. Baseline clinical and imaging variables were analyzed. For the imaging analysis, baseline CT and CTA were analyzed by a central core lab. Only those patients with good or moderate quality of baseline CTA and with confirmed BAO were included. Multivariable binary logistic regression analysis was used to test the independent association of clinical and imaging characteristics with a favorable outcome at 3 months (defined as a modified Rankin Score of ≤3). ROC curve analysis was used to assess and compare accuracy between the two collateral grading systems. Results: The mean age was 67.0 (±12.5) years, 196 (65.3%) patients were males and the median NIHSS was 21.5 (IQR 11-35). Median NCCT pc-ASPECTS was 10 (IQR10-10) and median collateral scores for BATMAN and PC-CS were 8 (IQR 7-9) and 7 (IQR 6-8) respectively. Collateral scores were associated with favorable outcome at 3 months for both BATMAN and PC-CS but only with a modest accuracy on ROC curve analysis (AUC 0.62, 95% CI [0.55-0.69] and 0.67, 95% CI [0.60-0.74] respectively). Age (OR 0.97, 95% CI [0.95-1.00]), NIHSS (OR 0.91, 95% CI [0.89-0.94]) and collateral score (PC-CS - OR 1.2495% CI [1.02-1.51]) were independently associated with clinical outcome. Conclusion: The two collateral grading systems presented modest prognostic accuracy. Only the PC-CS was independently associated with a favorable outcome at 3 months.

2.
Interv Neuroradiol ; : 15910199241239094, 2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38515399

RESUMO

BACKGROUND: The best strategy to achieve optimal reperfusion outcomes during mechanical thrombectomy remains to be defined. The RapidPulseTM Cyclic Aspiration System is a novel technology, delivering high-frequency pulsed vacuum forces to increase the efficiency of aspiration thrombectomy. METHODS: Prospective, multicenter, open-label, core lab-adjudicated, two-arm study comparing safety and efficacy of a feasibility version of the RapidPulseTM system compared with contemporary controls. Primary endpoint was the rate of mTICI ≥ 2c after first-pass effect (FPE). Additional efficacy endpoints were the rates of mTICI ≥ 2b after first pass (modified FPE (mFPE)), last pass with study device defined as frontline technical success, and after all passes including rescue therapy. The primary safety endpoints included symptomatic ICH (sICH) within 24 h post-procedure. RESULTS: Between February 2022 to December 2022, 80 subjects were consented and enrolled in the study (n = 40 treatment arm, n = 40 control arm). In the intent to treat (ITT) population, mean age was 67.8 ± 11.5 years; 19 (47.5%) were male. Median NIHSS score was 16 (IQR: 13-22). Median ASPECTS score was 9 (IQR: 8-10). The rate of mTICI ≥ 2c after first pass was 53.9% in ITT population (60.0% in per-protocol population) versus 38.5% in the corresponding control population. Functional independence (mRS 0-2) at 90 days was achieved in 61.1% (22/36) in the RapidPulseTM arm and 52.8% (19/36) in the control arm. In the RapidPulseTM arm, no sICH within 24 h and no device-related morbidity or mortality occurred. CONCLUSION: Preliminary data suggests RapidPulseTM Aspiration System is highly effective and safe for recanalization of large vessel occlusions.

3.
ROBRAC ; 19(48)abr. 2010. ilus, tab
Artigo em Português | LILACS | ID: lil-558305

RESUMO

A estabilidade primária dos implantes dentários influencia no índice de sucesso e na escolha do protocolo de tratamento. Para o emprego da técnica da carga imediata é essencial que o implante apresente boa estabilidade primária. No presente trabalho implantes com a forma cilíndrica e com perfil cônico foram inseridos em resina poliuretana e em blocos de costela suína. Determinaram-se os torques de inserção e de remoção Os resultados mostraram que a inserção dos implantes cilíndricos exige maior torque e que quanto menor o diâmetro da última fresa empregada para preparar o sítio de instalação, maior o torque para inserir os implantes.


The primary stability of dental implants influences the success rate and treatment protocol. To achieve success in the dental implant immediate loading is essential that the implant presents higher primary stability. In the present study dental implants with cylindrical and conical design were inserted into polyurethane and pork rib blocks. The results showed that the insertion of the cylindrical implant requires higher insertion torque than conical implant. The placement of dental implants using an undersized preparation technique resulted in enhanced primary implant stability.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA