RESUMO
INTRODUCTION: Changes in plasma sodium concentration (pNa, expressed in mEq/L) are common in hemodialysis (HD) patients. Hemodialysis monitors can estimate pNa by using an internal algorithm based on ion dialysance measurements. The present study studies the accuracy of the correlation between the pNa estimated by the dialysis monitor and that measured by the biochemistry laboratory at our center. MATERIAL AND METHODS: A single-centre prospective observational study in patients on a chronic HD program with the 6008 CAREsystem monitor and standard sodium (138mmol/L) and bicarbonate (32mmol/L) prescriptions. Venous blood samples were drawn from each patient before and after each HD session to ensure inter- and intra-individual validity. The pNa was measured in the biochemistry laboratory using indirect potentiometry and simultaneously the estimated pNa by the HD monitor was recorded at the beginning and at the end of the HD session. For statistical analysis, a scatterplot was made, and Spearman's correlation quotient was calculated. In addition, the differences between both methods were represented as Bland-Altman diagrams. RESULTS: The pre-dialysis pNa measured in the laboratory was 137.49±3.3, and that of the monitor, 137.96±2.91, with a correlation with R2 value of 0.683 (p<0.001). The post-dialysis pNa measured in the laboratory was 137.08±2.23, and that of the monitor was 138.87±1.88, with an R2 of 0.442 (p<0.001). On the Bland-Altman plots, the pre-dialysis pNa has a systematic error of 0.49, in favor of the monitor-estimated pNa, with a 95% confidence interval (CI) of (-3.24 to a 4.22). In the post-dialysis pNa, a systematic error of 1.79 with a 95% CI of (-1.64 to 5.22) was obtained. CONCLUSION: The correlation between the pNa estimated by Fresnius 6008 CAREsystem HD monitor and that measured by the laboratory is good, especially pre-dialysis measurements. Further studies should verify the external validity of these results.
Assuntos
Diálise Renal , Sódio , Humanos , Estudos Prospectivos , Sódio/sangue , Feminino , Masculino , Pessoa de Meia-Idade , IdosoRESUMO
Contrast-induced encephalopathy is a neurological complication related to contrast used in endovascular procedures or computed tomography (CT). The main risk factors are arterial hypertension, diabetes mellitus, chronic kidney disease (CKD), hyperosmolar contrasts, the amount of infused contrast and its direct infusion in the posterior cerebral territory, or pathologies with blood-brain barrier damage. Symptomatology is non-specific and may present as altered level of consciousness, neurological focality or seizures. Diagnosis is done by exclusion after ischemic or hemorrhagic stroke has been ruled out; CT or MRI are useful for differentiation. Generally, it appears shortly after exposure and the symptoms lasts 48-72h with complete recovery, although cases with persistence of symptoms or longer duration have been described. Treatment consists of monitoring, supportive measures and kidney replacement therapy (KRT) with hemodialysis (HD) in patients in chronic KRT program. It is important for the nephrologist to be aware of this entity given the susceptibility of the patient on HD as well as its potential therapeutic role in these patients.
Assuntos
Encefalopatias , Meios de Contraste , Insuficiência Renal Crônica , Humanos , Insuficiência Renal Crônica/complicações , Insuficiência Renal Crônica/terapia , Meios de Contraste/efeitos adversos , Encefalopatias/induzido quimicamente , Nefrologia , Fatores de Risco , Diálise RenalRESUMO
INTRODUCTION: New generation helixone dialyzers has recently been developed as part of the ongoing effort to improve dialyzer hemocompatibility and avoid adverse reactions to synthetic dialyzers. This study aimed to assess the performance and albumin loss of this new dialyzer series in hemodiafiltration and compare it with the previous generation helixone series. MATERIAL AND METHODS: A prospective study was conducted in 19 patients. Each patient underwent eight dialysis sessions with the same routine dialysis parameters; only the dialyzer varied: FX60 CorDiax, FX CorAL 60, FX600 CorDiax, FX CorAL 600, FX80 CorDiax, FX CorAL 80, FX800 CorDiax, and FX CorAL 800. The reduction ratios (RR) of urea, creatinine, ß2-microglobulin, myoglobin, kappa-free immunoglobulin light chains (κFLC), prolactin, α1-microglobulin, α1-acid glycoprotein, lambda immunoglobulin light chains (λFLC), and albumin were compared intra-individually. Dialysate albumin loss was also measured. RESULTS: All treatments were well tolerated. The mean amount of replacement fluid ranged from 31 to 34â¯L. Comparison of dialysis treatments showed no differences between small molecules and even up to those the size of ß2-microglobulins. Little differences were found between myoglobin, κFLC, prolactin, α1-microglobulin, and λFLC RRs, and only FX80 CorDiax was slightly superior to the others. Mean dialysate albumin losses were similar, with less than 2.5â¯g lost in each dialyzer. The FX80 CorDiax showed slightly higher global removal scores than the other dialyzers evaluated, except for FX CorAL 800. CONCLUSION: The new generation helixone dialyzers series has been updated to minimise the risk of adverse reactions, while maintaining the effectiveness and albumin loss achieved by the previous most advanced helixone generation.
Assuntos
Hemodiafiltração , Humanos , Estudos Prospectivos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Hemodiafiltração/instrumentação , Hemodiafiltração/métodos , Desenho de Equipamento , Adulto , Resultado do Tratamento , Albumina Sérica/análise , Idoso de 80 Anos ou maisRESUMO
BACKGROUND: New versions of the polyester polymer alloy (PEPA) membrane have appeared over the years, with increases in both the pore size and the amount of polyvinylpyrrolidone (PVP) to optimize hydrophilicity performance. This study aimed to assess the efficacy of the most recently developed PEPA dialyzer, the FDY series, in hemodialysis (HD) modality in terms of uremic toxin removal and albumin loss and to compare it with that of several high-flux dialyzers currently used in HD and post-dilution hemodiafiltration (HDF) treatments. METHODS: A prospective study was carried out in 21 patients. All patients underwent six dialysis sessions with the same routine dialysis parameters; only the dialyzer and/or the dialysis modality varied: FX80 in HD, FDY 180 in HD, Clearum HS17 in HDF, Elisio 19H in HDF, Vitapes 180 in HDF, and FX80 in post-dilution HDF. The reduction ratios (RR) of urea, creatinine, ß2-microglobulin, myoglobin, κFLC, prolactin, α1-microglobulin, α1-acid glycoprotein, λFLC, and albumin were compared intraindividually. Dialysate albumin loss was also measured. RESULTS: Both membranes FDY and FX80 are high-flux dialyzers and are applied here in high-flux HD. The average RR of ß2-microglobulin was slightly lower in the two HD treatments than in the HDF treatments. Comparison of dialysis treatments revealed that the PEPA FDY dialyzer in the HD modality was more effective than the FX80 dialyzer in high-flux HD and was as effective as post-dilution HDF, especially in terms of myoglobin, κFLC, prolactin, α1-microglobulin, and λFLC RRs. The FDY treatments obtained similar albumin RR in blood and slightly higher dialysate albumin loss, although the values were clinically acceptable. CONCLUSIONS: The most recently developed PEPA dialyzers in the HD modality were as effective as all treatments in the HDF modality and were clearly superior to high-flux helixone HD treatment. These results confirm that this dialyzer should be categorized within the medium cut-off (MCO) membrane classification.
Assuntos
Membranas Artificiais , Poliésteres , Diálise Renal , Humanos , Masculino , Diálise Renal/instrumentação , Diálise Renal/métodos , Pessoa de Meia-Idade , Feminino , Idoso , Estudos Prospectivos , Poliésteres/química , Ligas/química , Idoso de 80 Anos ou mais , Hemodiafiltração/instrumentação , Hemodiafiltração/métodos , Adulto , Polímeros/químicaRESUMO
Background: The number of frail patients of advanced age with end-stage kidney disease (ESKD) undergoing hemodialysis is increasing globally. Here we evaluated a frailty screening program of ESKD patients starting hemodialysis, and subsequent multidisciplinary interventions. Methods: This was a prospective observational study of ESKD patients in a hemodialysis program. Patients were evaluated for frailty (Fried frail phenotype) before and after a 12-month period. Patients followed standard clinical practice at our hospital, which included assessment and multidisciplinary interventions for nutritional (malnutrition-inflammation score, protein-energy wasting), physical [short physical performance battery (SPPB)] and psychological status. Results: A total of 167 patients (mean ± standard deviation age 67.8 ± 15.4 years) were screened for frailty, and 108 completed the program. At screening, 27.9% of the patients were frail, 40.0% pre-frail and 32.1% non-frail. Nutritional interventions (enrichment, oral nutritional supplements, intradialytic parenteral nutrition) resulted in stable nutritional status for most frail and pre-frail patients after 12 months. Patients following recommendations for intradialytic, home-based or combined physical exercise presented improved or stable in SPPB scores after 12 months, compared with those that did not follow recommendations, especially in the frail and pre-frail population (P = .025). A rate of 0.05 falls/patient/year was observed. More than 60% of frail patients presented high scores of sadness and anxiety. Conclusions: Frailty screening, together with coordinated interventions by nutritionists, physiotherapists, psychologists and nurses, preserved the health status of ESKD patients starting hemodialysis. Frailty assessment helped in advising patients on individual nutritional, physical or psychological needs.
RESUMO
Background: Up to 50-60% of patients with diabetes have non-diabetic kidney disease (NDKD) on kidney biopsy. Diabetic retinopathy (DR) is a microvascular complication of diabetes frequently associated with diabetic nephropathy (DN). The objective of the current study was to investigate the kidney outcomes and survival in patients with biopsy diagnoses of DN and NDKD according to the presence of DR. Methods: We conducted an observational, multicentre and retrospective study of the pathological findings of renal biopsies from 832 consecutive patients with diabetes from 2002 to 2014 from 18 nephrology departments. The association of DR with kidney replacement therapy (KRT) or survival was assessed by Kaplan-Meier and Cox regression analyses. Results: Of 832 patients with diabetes and renal biopsy, 768 had a retinal examination and 221/768 (22.6%) had DR. During a follow-up of 10 years, 288/760 (37.9%) patients with follow-up data needed KRT and 157/760 (20.7%) died. The incidence of KRT was higher among patients with DN (alone or with NDKD) and DR [103/175 (58.9%)] than among patients without DR [88/216 (40.7%), P < .0001]. The incidence of KRT was also higher among patients with only NDKD and DR than among those without DR [18/46 (39.1%) versus 79/331 (23.9%), P < .0001]. In multivariate analysis, DR or DN were independent risk factors for KRT {hazard ratio [HR] 2.48 [confidence interval (CI) 1.85-3.31], P < .001}. DN (with or without DR) was also identified as an independent risk factor for mortality [HR 1.81 (CI 1.26-2.62), P = .001]. Conclusions: DR is associated with a higher risk of progression to kidney failure in patients with histological DN and in patients with NDKD.
RESUMO
Introduction: Macroscopic hematuria (MH) bouts, frequently accompanied by acute kidney injury (AKI-MH) are one of the most common presentations of IgA nephropathy (IgAN) in the elderly. Immunosuppressive therapies are used in clinical practice; however, no studies have analyzed their efficacy on kidney outcomes. Methods: This is a retrospective, multicenter study of a cohort of patients aged ≥50 years with biopsy-proven IgAN presenting with AKI-MH. Outcomes were complete, partial, or no recovery of kidney function at 1 year after AKI-MH, and kidney survival at 1, 2, and 5 years. Propensity score matching (PSM) analysis was applied to balance baseline differences between patients treated with immunosuppression and those not treated with immunosuppression. Results: The study group consisted of 91 patients with a mean age of 65 ± 15 years, with a mean follow-up of 59 ± 36 months. Intratubular red blood cell (RBC) casts and acute tubular necrosis were found in all kidney biopsies. The frequency of endocapillary hypercellularity and crescents were low. Immunosuppressive therapies (corticosteroids alone or combined with mycophenolate mofetil or cyclophosphamide) were prescribed in 52 (57%) patients, whereas 39 (43%) received conservative treatment. There were no significant differences in the proportion of patients with complete, partial, or no recovery of kidney function at 1 year between patients treated with immunosuppression and those not treated with immunosuppression (29% vs. 36%, 30.8% vs. 20.5% and 40.4 % vs. 43.6%, respectively). Kidney survival at 1, 3, and 5 years was similar among treated and untreated patients (85% vs. 81%, 77% vs. 76% and 72% vs. 66%, respectively). Despite the PSM analysis, no significant differences were observed in kidney survival between the two groups. Fourteen patients (27%) treated with immunosuppression had serious adverse events. Conclusions: Immunosuppressive treatments do not modify the unfavorable prognosis of patients with IgAN who are aged ≥50 years presenting with AKI-MH, and are frequently associated with severe complications.
RESUMO
INTRODUCTION: Adherence to a low-sodium (Na) diet is crucial in patients under hemodialysis, as it improves cardiovascular outcomes and reduces thirst and interdialytic weight gain. Recommended salt intake is lower than 5 g/day. The new 6008 CAREsystem monitors incorporate a Na module that offers the advantage of estimating patients' salt intake. The objective of this study was to evaluate the effect of dietary Na restriction for 1 week, monitored with the Na biosensor. METHODS: A prospective study was conducted in 48 patients who maintained their usual dialysis parameters and were dialyzed with a 6008 CAREsystem monitor with activation of the Na module. Total Na balance, pre-/post-dialysis weight, serum Na (sNa), changes in pre- to post-dialysis sNa (ΔsNa), diffusive balance, and systolic and diastolic blood pressure were compared twice, once after 1 week of patients' usual Na diet and again after another week with more restricted Na intake. RESULTS: Restricted Na intake increased the percentage of patients on a low-Na diet (<85 Na mmol/day) from 8% to 44%. Average daily Na intake decreased from 149 ± 54 to 95 ± 49 mmol, and interdialytic weight gain was reduced by 460 ± 484 g per session. More restricted Na intake also decreased pre-dialysis sNa and increased both intradialytic diffusive balance and ΔsNa. In hypertensive patients, reducing daily Na by more than 3 g Na/day lowered their systolic blood pressure. CONCLUSIONS: The new Na module allowed objective monitoring of Na intake, which in turn could permit more precise personalized dietary recommendations in patients under hemodialysis.
Assuntos
Cloreto de Sódio na Dieta , Sódio , Humanos , Estudos Prospectivos , Diálise Renal/métodos , Dieta Hipossódica , Pressão Sanguínea , Aumento de PesoRESUMO
Background: A key feature of dialysis treatment is the prescription of dialysate sodium (Na). This study aimed to describe the practical implementation of a new automated dialysate Na control biosensor and to assess its tolerance and the beneficial clinical effects of isonatraemic dialysis. Methods: A prospective study was carried out in 86 patients who, along with their usual parameters, received the following five consecutive phases of treatment for 3 weeks each: phase 0: baseline 5008 machine; phases 1 and 2: 6008 machine without activation of the Na control biosensor and the same fixed individualized Na dialysate prescription or adjusted to obtain similar conductivity to phase 0; phases 3 and 4: activated Na control to isonatraemic dialysis (Na dialysate margins 135-141 or 134-142 mmol/L). Results: When the Na control was activated, the few episodes of cramps or hypotension disappeared when the lower dialysate Na margin was increased by 1 or 2 mmol/L. The activated Na control module showed significant differences compared with baseline and the non-activated Na module in final serum Na values, diffusive Na balance, and changes in pre- to postdialysis plasma Na values. The mean predialysis systolic blood pressure value was significantly lower in phase 4 than in phase 1. There were no significant differences in total Na balance in the four 6008 phases evaluated. Conclusions: The implementation of the automated dialysate Na control module is a useful new tool, which reduced the diffusive load of Na with good tolerance. The module had the advantages of reducing thirst, interdialytic weight gain and intradialytic plasma Na changes.
RESUMO
The following paper reports the case of a woman on in-center hemodialysis through an arteriovenous graft, who attended with an acute vascular access thrombosis. Post percutaneous thrombectomy, the patient presented a rare case of self-limited acute hepatitis secondary to the revascularization procedure. We explain the probable trigger for this complication, its pathophysiology, management, and evolution.
Assuntos
Derivação Arteriovenosa Cirúrgica , Hepatite , Trombose , Feminino , Humanos , Oclusão de Enxerto Vascular/diagnóstico por imagem , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/cirurgia , Grau de Desobstrução Vascular , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Trombectomia/efeitos adversos , Trombose/diagnóstico por imagem , Trombose/etiologia , Trombose/cirurgia , Diálise Renal/efeitos adversos , Hepatite/complicações , Resultado do Tratamento , Estudos RetrospectivosRESUMO
INTRODUCTION: The medium cut-off Elisio HX dialyzer by Nipro became commercially available in Europe in 2021, but there are still no reports of in vivo data. This study aimed to evaluate the safety and efficacy of it compared with previously evaluated hemodialysis (HD), expanded HD (HDx), and postdilution hemodiafiltration (HDF) treatments. METHODS: A prospective study was carried out on 18 patients who underwent 5 dialysis sessions: FX80 Cordiax in HD, Elisio H19 in HD, Elisio HX19 in HDx, Theranova 400 in HDx, and FX80 Cordiax in HDF. The reduction ratios of urea, creatinine, ß2-microglobulin, myoglobin, kappa FLC, prolactin, α1-microglobulin, α1-acid glycoprotein, lambda FLC, and albumin were compared. Dialysate albumin loss was measured. RESULTS: The comparison between the different dialysis modalities revealed no difference for small molecules, but HDx and HDF were significantly more efficient than HD for medium and large molecule removal. The efficacy of Elisio HX19 dialyzer in HDx was similar to the Theranova 400, superior to both dialyzers in HD, and slightly lower than HDF. Albumin losses in dialysate with HD dialyzers were less than 1 g, but between 1.5 and 2.5 g in HDx and HDF. The global removal score (GRS) values with HDx treatments were statistically significantly higher than those with HD. The highest GRS was obtained with the helixone dialyzer in HDF. CONCLUSIONS: The new MCO dialyzer, Elisio HX, performs with excellent behavior and tolerance. It represents an upgrade compared to their predecessor and is very close to the removal capacity of HDF treatment.
Assuntos
Hemodiafiltração , Diálise Renal , Humanos , Estudos Prospectivos , Hemodiafiltração/efeitos adversos , Albuminas , Soluções para DiáliseRESUMO
INTRODUCTION: The sodium gradient during hemodialysis sessions is one of the key factors in sodium balance in patients with dialysis-dependent chronic kidney disease; however, until the appearance of the new monitors with sodium modules, the differences between prescribed and measured sodium have been understudied. The present study aimed to compare the impact on the measured conductivity and the initial and final plasma sodium after changing the 5008 Cordiax to the new 6008 Cordiax monitor. MATERIAL AND METHODS: 106 patients on hemodialysis were included. Each patient underwent 2 dialysis sessions in which only the monitor was varied. The variables collected were dialysate, sodium and bicarbonate prescribed, real conductivity, initial and final plasma sodium measured, and the calculated sodium gradient (ΔPNa). RESULTS: The change of dialysis monitor showed small but statistically significant differences in the initial (138.14mmol/L with 5008 vs. 138.81mmol/L with 6008) and final plasma sodium (139.58mmol/L vs. 140.97mmol/L), as well as in the actual conductivity obtained (13.97 vs. 14.1mS/cm). The ΔPNa also increased significantly. CONCLUSION: The change from 5008 to 6008 monitor is associated with increased conductivity, leading the patient to end the sessions with higher plasma sodium and ΔPNa. Knowing and confirming this change will allow us to individualize the sodium prescription and avoid possible undesirable effects. It could be the preliminary study to explore the new sodium biosensor incorporated into the new generation of monitors.
Assuntos
Diálise Renal , Sódio , Humanos , Diálise Renal/efeitos adversos , Soluções para DiáliseRESUMO
Background: Recently, several pharmaceutical companies have developed new medium cut-off (MCO) dialyzers for expanded hemodialysis (HDx). This study aimed to compare the safety and efficacy of four MCO dialyzers, against each other and versus high-flux hemodialysis (HD) and post-dilution hemodiafiltration (HDF). Methods: A prospective study was carried out on 23 patients who underwent six dialysis sessions: two sessions with the FX80 Cordiax in HD and HDF, and four HDx sessions with the Phylther 17-SD, Vie-18X, Elisio HX19 and Theranova 400 dialyzers. The reduction ratios (RRs) of urea, creatinine, ß2-microglobulin, myoglobin, kappa free immunoglobulin light chain (κFLC), prolactin, α1-microglobulin, α1-acid glycoprotein, lambda (λFLC) and albumin were compared. Dialysate albumin loss was also measured. Results: The differences in efficacy between the evaluated dialyzers were minimal in small molecules and even up to the size of ß2-microglobulin. The main differences were found between myoglobin, κFLC, prolactin, α1-microglobulin and λFLC RRs, in which all four MCO dialyzers, with similar efficacy, were clearly superior to HD and slightly inferior to HDF treatment. Albumin losses in the dialysate with HD dialyzers were <1 g and between 1.5 and 2.5 g in HDx and HDF. The global removal score values were similar in all four HDx treatments, and again significantly higher than those with HD. Conclusions: The results of the four MCO dialyzers evaluated in this study showed good efficiency, with no significant performance differences between them while being completely safe in terms of albumin loss. Likewise, the study confirms the superiority of HDx over high-flux HD with an efficacy close to that of post-dilution HDF.
RESUMO
Background: Both metabolic acidosis and alkalosis increase hospitalizations, haemodynamic instability and mortality in haemodialysis patients. Unfortunately, current practices opt for a one-size-fits-all approach, leaving many patients either acidotic before or alkalotic after dialysis sessions. Therefore an individualized adjustment of these patients' dialysate bicarbonate prescriptions could reduce these acid-base imbalances. Methods: This is a prospective single-cohort study of patients on a chronic haemodiafiltration programme. The dialysate bicarbonate prescription was modified according to the pre- and post-dialysis total carbon dioxide (TCO2) values of 19-25 mEq/L and ≤29 mEq/L, respectively, with an adjustment formula calculated with the data obtained from previously published work by our group. In addition, we analysed this adjustment's effect on plasma sodium, potassium, phosphorus, parathyroid hormone (PTH) and calcium. Results: At baseline, only 67.9% of patients were within the desired pre- and post-dialysis TCO2 target range. As of the first month, every followed patient met the TCO2 target range objective in pre-dialysis measurements and Ë95% met the post-dialysis TCO2 target. At the end of the study, 75% of the patients were on dialysate bicarbonate of 32-34 mEq/L. There were no clinically significant changes in calcium, phosphate, PTH, sodium or potassium levels. Also, we did not notice any increase in intradialytic adverse events. Conclusions: We suggest an individualized adjustment of the dialysate bicarbonate concentration according to the pre- and post-dialysis TCO2 values. With it, nearly every patient in our cohort reached the established range, potentially reducing their mortality risk.
RESUMO
Introduction: IgA nephropathy (IgAN) is the most common primary glomerulonephritis (GN) worldwide. The disease course fluctuates, and the most important challenge is the considerable variation in the time lag between diagnosis and the development of a hard clinical end point, such as end-stage kidney disease (ESKD). The reaction of renal tissue to damage resembles the common wound-healing response. One part of this repair in IgAN is the expansion of lymphatic vessels known as lymphangiogenesis. The aim of this work was to establish the prognostic value of the density of lymphatic vessels in the renal biopsy at the time of diagnosis, for predicting the risk of ESKD in a Spanish cohort of patients with IgAN. Methods: We performed a retrospective multicenter study of 76 patients with IgAN. The end point of the study was progression to ESKD. The morphometric analysis of lymphatic vessels was performed on tissue sections stained with antipodoplanin antibody. Results: Density of lymphatic vessels was significantly higher in patients with IgAN with mesangial hypercellularity >50%, segmental sclerosis, higher degrees of interstitial fibrosis, and tubular atrophy. Patients with more lymphatic vessels had significantly higher values of proteinuria and lower estimated glomerular filtration rate (eGFR). A density of lymphatic vessels ≥8 per mm2 was associated with a significantly higher rate of progression to ESKD at 3 years from biopsy. After adjustment for the International IgAN prediction score, at the multivariate logistic regression, high density of lymphatic vessels (≥8 per mm2) remained significantly associated with a higher rate of early progression to ESKD. Conclusion: This study contributes to the understanding of the natural history of the progression to ESKD in patients with IgAN revealing the density of lymphatics vessels may optimize the prognostic value of the International IgA predicting tool to calculate the risk of ESKD, favoring the evaluation of new targeted therapies.
RESUMO
INTRODUCTION: Given the increased COVID-19 observed in kidney transplant recipients (KTRs) and haemodialysis patients, several studies have tried to establish the efficacy of mRNA vaccines in these populations by evaluating their humoral and cellular responses. However, there is currently no information on clinical protection (deaths and hospitalizations), a gap that this study aims to fill. METHODS: Observational prospective study involving 1,336 KTRs and haemodialysis patients from three dialysis units affiliated to Hospital Clínic of Barcelona, Spain, vaccinated with two doses of mRNA-1273 (Moderna) or BNT162b2 (Pfizer-BioNTech) SARS-CoV-2 mRNA vaccines. The outcomes measured were SARS-CoV-2 infection diagnosed by a positive RT-PCR fourteen days after the second vaccine dose, hospital admissions derived from infection, and a severe COVID-19 composite outcome, defined as either ICU admission, invasive and non-invasive mechanical ventilation, or death. RESULTS: Six per cent (18/302) of patients on haemodialysis were infected, of whom four required hospital admission (1.3%), only one (0.3%) had severe COVID-19, and none of them died. In contrast, 4.3% (44/1034) of KTRs were infected, and presented more hospital admissions (26 patients, 2.5%), severe COVID-19 (11 patients, 1.1%) or death (4 patients, 0.4%). KTRs had a significantly higher risk of hospital admission than HD patients, and this risk increased with age and male sex (HR 3.37 and 4.74, respectively). CONCLUSIONS: The study highlights the need for booster doses in KTRs. In contrast, the haemodialysis population appears to have an adequate clinical response to vaccination, at least up to four months from its administration.