Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Chest ; 164(3): 700-716, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-36965765

RESUMO

BACKGROUND: Microvascular abnormalities and impaired gas transfer have been observed in patients with COVID-19. The progression of pulmonary changes in these patients remains unclear. RESEARCH QUESTION: Do patients hospitalized with COVID-19 without evidence of architectural distortion on structural imaging exhibit longitudinal improvements in lung function measured by using 1H and 129Xe MRI between 6 and 52 weeks following hospitalization? STUDY DESIGN AND METHODS: Patients who were hospitalized with COVID-19 pneumonia underwent a pulmonary 1H and 129Xe MRI protocol at 6, 12, 25, and 51 weeks following hospital admission in a prospective cohort study between November 2020 and February 2022. The imaging protocol was as follows: 1H ultra-short echo time, contrast-enhanced lung perfusion, 129Xe ventilation, 129Xe diffusion-weighted, and 129Xe spectroscopic imaging of gas exchange. RESULTS: Nine patients were recruited (age 57 ± 14 [median ± interquartile range] years; six of nine patients were male). Patients underwent MRI at 6 (n = 9), 12 (n = 9), 25 (n = 6), and 51 (n = 8) weeks following hospital admission. Patients with signs of interstitial lung damage were excluded. At 6 weeks, patients exhibited impaired 129Xe gas transfer (RBC to membrane fraction), but lung microstructure was not increased (apparent diffusion coefficient and mean acinar airway dimensions). Minor ventilation abnormalities present in four patients were largely resolved in the 6- to 25-week period. At 12 weeks, all patients with lung perfusion data (n = 6) showed an increase in both pulmonary blood volume and flow compared with 6 weeks, although this was not statistically significant. At 12 weeks, significant improvements in 129Xe gas transfer were observed compared with 6-week examinations; however, 129Xe gas transfer remained abnormally low at weeks 12, 25, and 51. INTERPRETATION: 129Xe gas transfer was impaired up to 1 year following hospitalization in patients who were hospitalized with COVID-19 pneumonia, without evidence of architectural distortion on structural imaging, whereas lung ventilation was normal at 52 weeks.


Assuntos
COVID-19 , Isótopos de Xenônio , Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Idoso , Feminino , Estudos Prospectivos , Imageamento por Ressonância Magnética/métodos , Pulmão/diagnóstico por imagem
2.
Br J Radiol ; 95(1132): 20210872, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-35100003

RESUMO

OBJECTIVES: Design and build a portable xenon-129 (129Xe) hyperpolariser for clinically accessible 129Xe lung MRI. METHODS: The polariser system consists of six main functional components: (i) a laser diode array and optics; (ii) a B0 coil assembly; (iii) an oven containing an optical cell; (iv) NMR and optical spectrometers; (v) a gas-handling manifold; and (vi) a cryostat within a permanent magnet. All components run without external utilities such as compressed air or three-phase electricity, and require just three mains sockets for operation. The system can be manually transported in a lightweight van and rapidly installed on a small estates footprint in a hospital setting. RESULTS: The polariser routinely provides polarised 129Xe for routine clinical lung MRI. To test the concept of portability and rapid deployment, it was transported 200 km, installed at a hospital with no previous experience with the technology and 129Xe MR images of a diagnostic quality were acquired the day after system transport and installation. CONCLUSION: This portable 129Xe hyperpolariser system could form the basis of a cost-effective platform for wider clinical dissemination and multicentre evaluation of 129Xe lung MR imaging. ADVANCES IN KNOWLEDGE: Our work successfully demonstrates the feasibility of multicentre clinical 129Xe MRI with a portable hyperpolariser system.


Assuntos
Imageamento por Ressonância Magnética , Isótopos de Xenônio , Humanos , Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética
3.
Magn Reson Med ; 85(3): 1561-1570, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32926448

RESUMO

PURPOSE: To measure the transverse relaxation time ( T 2 ∗ ) and apparent diffusion coefficient (ADC) of 19 F-C3 F8 gas in vivo in human lungs at 1.5T and 3T, and to determine the representative distribution of values of these parameters in a cohort of healthy volunteers. METHODS: Mapping of ADC at lung inflation levels of functional residual capacity (FRC) and total lung capacity (TLC) was performed with inhaled 19 F-C3 F8 (eight subjects) and 129 Xe (six subjects) at 1.5T. T 2 ∗ mapping with 19 F-C3 F8 was performed at 1.5T (at FRC and TLC) for 8 subjects and at 3T (at TLC for seven subjects). RESULTS: At both FRC and TLC, the 19 F-C3 F8 ADC was smaller than the free diffusion coefficient demonstrating airway microstructural diffusion restriction. From FRC to TLC, the mean ADC significantly increased from 1.56 mm2 /s to 1.83 mm2 /s (P = .0017) for 19 F-C3 F8, and from 2.49 mm2 /s to 3.38 mm2 /s (P = .0015) for 129 Xe. The posterior-to-anterior gradient in ADC for FRC versus TLC in the superior half of the lungs was measured as 0.0308 mm2 /s per cm versus 0.0168 mm2 /s per cm for 19 F-C3 F8 and 0.0871 mm2 /s per cm versus 0.0326 mm2 /s per cm for 129 Xe. A consistent distribution of 19 F-C3 F8 T 2 ∗ values was observed in the lungs, with low values observed near the diaphragm and large pulmonary vessels. The mean T 2 ∗ across volunteers was 4.48 ms at FRC and 5.33 ms at TLC for 1.5T, and 3.78 ms at TLC for 3T. CONCLUSION: In this feasibility study, values of physiologically relevant parameters of lung microstructure measurable by MRI ( T 2 ∗ , and ADC) were established for C3 F8 in vivo lung imaging in healthy volunteers.


Assuntos
Pulmão , Imageamento por Ressonância Magnética , Imagem de Difusão por Ressonância Magnética , Voluntários Saudáveis , Humanos , Pulmão/diagnóstico por imagem , Testes de Função Respiratória
4.
Magn Reson Med ; 83(1): 262-270, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31400040

RESUMO

PURPOSE: To assess the feasibility of using dissolved hyperpolarized xenon-129 (129 Xe) MRI to study renal physiology in humans at 3 T. METHODS: Using a flexible transceiver RF coil, dynamic and spatially resolved 129 Xe spectroscopy was performed in the abdomen after inhalation of hyperpolarized 129 Xe gas with 3 healthy male volunteers. A transmit-only receive-only RF coil array was purpose-built to focus RF excitation and enhance sensitivity for dynamic imaging of 129 Xe uptake in the kidneys using spoiled gradient echo and balanced steady-state sequences. RESULTS: Using spatially resolved spectroscopy, different magnitudes of signal from 129 Xe dissolved in red blood cells and tissue/plasma could be identified in the kidneys and the aorta. The spectra from both kidneys showed peaks with similar amplitudes and chemical shift values. Imaging with the purpose-built coil array was shown to provide more than a 3-fold higher SNR in the kidneys when compared with surrounding tissues, while further physiological information from the dissolved 129 Xe in the lungs and in transit to the kidneys was provided with the transceiver coil. The signal of dissolved hyperpolarized 129 Xe could be imaged with both tested sequences for about 40 seconds after inhalation. CONCLUSION: The uptake of 129 Xe dissolved in the human kidneys was measured with spectroscopic and imaging experiments, demonstrating the potential of hyperpolarized 129 Xe MR as a novel, noninvasive technique to image human kidney tissue perfusion.


Assuntos
Rim/diagnóstico por imagem , Imageamento por Ressonância Magnética , Perfusão , Isótopos de Xenônio , Abdome/diagnóstico por imagem , Adulto , Gases , Humanos , Processamento de Imagem Assistida por Computador/métodos , Pulmão/diagnóstico por imagem , Masculino , Projetos Piloto , Ondas de Rádio , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA