Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
Water Res ; 242: 120275, 2023 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-37413746

RESUMO

A mathematical correlation between biomass kinetic and membrane fouling can improve the understanding and spread of Membrane Bioreactor (MBR) technology, especially in solving the membrane fouling issues. On this behalf, this paper, produced by the International Water Association (IWA) Task Group on Membrane modelling and control, reviews the current state-of-the-art regarding the modelling of kinetic processes of biomass, focusing on modelling production and utilization of soluble microbial products (SMP) and extracellular polymeric substances (EPS). The key findings of this work show that the new conceptual approaches focus on the role of different bacterial groups in the formation and degradation of SMP/EPS. Even though several studies have been published regarding SMP modelling, there still needs to be more information due to the highly complicated SMP nature to facilitate the accurate modelling of membrane fouling. The EPS group has seldom been addressed in the literature, probably due to the knowledge deficiency concerning the triggers for production and degradation pathways in MBR systems, which require further efforts. Finally, the successful model applications showed that proper estimation of SMP and EPS by modelling approaches could optimise membrane fouling, which can influence the MBR energy consumption, operating costs, and greenhouse gas emissions.


Assuntos
Matriz Extracelular de Substâncias Poliméricas , Membranas Artificiais , Reatores Biológicos/microbiologia , Bactérias , Biomassa , Esgotos/microbiologia
2.
Membranes (Basel) ; 13(3)2023 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-36984652

RESUMO

The granular sludge based anaerobic membrane bioreactor (G-AnMBR) has gained emphasis in the last decade by combining AnMBR advantages (high quality permeate and biogas production towards energy positive treatment) and benefits of granular biomass (boosted biological activity and reduced membrane fouling). With the aim to further reduce energy costs, produce higher quality effluent for water reuse applications and improve system efficiency, a forward osmosis (FO) system was integrated into a 17 L G-AnMBR pilot. Plate and frame microfiltration modules were step by step replaced by submerged FO ones, synthetic wastewater was used as feed (chemical oxygen demand (COD) content 500 mg/L), with hydraulic retention time of 10 h and operated at 25 °C. The system was fed with granular biomass and after the acclimation period, operated neither with gas sparging nor relaxation at around 5 L.m-2.h-1 permeation flux during at least 10 days for each tested configuration. Process stability, impact of salinity on biomass, the produced water quality and organic matter removal efficiency were assessed and compared for the system working with 100% microfiltration (MF), 70% MF/30% FO, 50% MF/50% FO and 10% MF/90% FO, respectively. Increasing the FO share in the reactor led to salinity increase and to enhanced fouling propensity probably due to salinity shock on the active biomass, releasing extracellular polymeric substances (EPS) in the mixed liquor. However, above 90% COD degradation was observed for all configurations with a remaining COD content below 50 mg/L and below the detection limit for MF and FO permeates, respectively. FO membranes also proved to be less prone to fouling in comparison with MF ones. Complete salt mass balance demonstrated that major salinity increase in the reactor was due to reverse salt passage from the draw solution but also that salts from the feed solution could migrate to the draw solution. While FO membranes allow for full rejection and very high permeate purity, operation of G-AnMBR with FO membranes only is not recommended since MF presence acts as a purge and allows for reactor salinity stabilization.

3.
Membranes (Basel) ; 12(11)2022 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-36422162

RESUMO

Landfill leachate (LFL) has a complex inorganic, organic and microbiological composition. Although pressure-driven membrane technology contributes to reaching the discharge limits, the need for frequent membrane replacement (typically every 1-3 years) is an economical and environmental limitation. The goal of this work is to evaluate the feasibility of using second-hand reverse osmosis (RO) membranes to treat LFL in an industrially relevant environment. End-of-life RO membranes discarded from a seawater desalination plant were first tested with brackish water and directly reused or regenerated to fit with requirements for LFL treatment. A laboratory scale test of second-hand membrane reuse was carried out using ultrafiltered LFL. Then, a long-term test in an LFL full-scale facility was performed, where half of the membranes of the facility were replaced. The industrial plant was operated for 27 months with second-hand membranes. The permeate water quality fit the required standards and the process showed a trend of lower energy requirement (up to 12 bar lower transmembrane pressure and up to 9% higher recovery than the average of the previous 4 years). Direct reuse and membrane regeneration were successfully proven to be an alternative management to landfill disposal, boosting membranes towards the circular economy.

4.
Water Res ; 199: 117166, 2021 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-33984584

RESUMO

Impacts from urban wastewater treatment plants (WWTP) to receiving riverine surface water bodies (SWBs) depend on the load of contaminants discharged, as well as on their dilution capacity. Yet, climate change impacts on such dilution capacity and ultimately on the SWBs ecological status remain unclear. Here, we assess SWBs dilution capacity across the European continent to identify most vulnerable areas using information from centralized European databases. SWBs´ future dilution factor values are estimated based on representative concentration pathway scenarios impacts on rivers flow, and likely changes in European SWBs´ ecological status foretold. Results show that dilution factor in Europe increases by 5.4% in average. Yet, climate change effects are found to lead to a consistent dilution factor decrease for 11% of the 40074 European SWBs receiving WWTP discharge for the early century. This share reaches 17% for the midcentury period. We estimate that up to 42% of the SWBs receiving WWTP discharges and currently reaching a good ecological status show a 0.7 probability to have their ecological status downgraded due to climate change. Sites more vulnerable are located in the Mediterranean countries. Our findings highlight that climate change mitigation is essential for maintaining good ecological status in European SWBs.


Assuntos
Rios , Purificação da Água , Mudança Climática , Monitoramento Ambiental , Europa (Continente)
5.
Bioresour Technol ; 329: 124828, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33621928

RESUMO

Integrated Membrane Bioreactor (MBR) models, combination of biological and physical models, have been representing powerful tools for the accomplishment of high environmental sustainability. This paper, produced by the International Water Association (IWA) Task Group on Membrane Modelling and Control, reviews the state-of-the-art, identifying gaps for future researches, and proposes a new integrated MBR modelling framework. In particular, the framework aims to guide researchers and managers in pursuing good performances of MBRs in terms of effluent quality, operating costs (such as membrane fouling, energy consumption due to aeration) and mitigation of greenhouse gas emissions.


Assuntos
Gases de Efeito Estufa , Eliminação de Resíduos Líquidos , Reatores Biológicos , Membranas Artificiais , Modelos Teóricos , Águas Residuárias
6.
Water Res ; 175: 115657, 2020 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-32151816

RESUMO

The feasibility of Forward Osmosis (FO) as an alternative treatment technology to current membrane processes is believed to hinge on its reported lower fouling propensity. In this study, the impacts of constant osmotic pressure and hydraulic pressure driving forces on membrane fouling were investigated using a novel approach. In each case the cake layer was modelled accounting for all concentration polarisation effects and effective driving force. Compared to the widely employed method of using a non-constant osmotic pressure difference during bench-scale fouling experiments, maintaining a constant osmotic pressure led to 50% more alginate deposited on the same membrane surface (from 13.7 to 21.7 g/m2). This was attributed to a stronger osmotic driving force at the active layer interface and enhanced fouling due to a greater reverse flux of Na+ ions. An applied hydraulic pressure of 1 bar already changed fouling cake deposition and the cake structural parameter shrunk by 224 and 83 µm for the two thin-film composite membranes tested. A detailed analysis of the model however demonstrated that it needs further development, incorporating pore size, porosity and tortuosity of the foulant cake to enable drawing reliable conclusions on the causality of cake layer compaction.


Assuntos
Membranas Artificiais , Purificação da Água , Alginatos , Osmose , Pressão Osmótica
7.
Membranes (Basel) ; 9(8)2019 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-31387333

RESUMO

Applying forward osmosis directly on raw municipal wastewater is of high interest for the simultaneous production of a high quality permeate for water reuse and pre-concentrating wastewater for anaerobic digestion. This pilot scale study investigates, for the first time, the feasibility of concentrating real raw municipal wastewater using a submerged plate and frame forward osmosis module (0.34 m2) to reach 70% water recovery. Membrane performance, fouling behavior, and effective concentration of wastewater compounds were examined. Two different draw solutions (NaCl and MgCl2), operating either with constant draw concentration or in batch with draw dilution over time, were evaluated. Impact of gas sparging on fouling and external concentration polarization was also assessed. Water fluxes up to 15 L m-2 h-1 were obtained with clean water and 35 g NaCl/L as feed and draw solution, respectively. When using real wastewater, submerged forward osmosis proved to be resilient to clogging, demonstrating its suitability for application on municipal or other complex wastewater; operating with 11.7 g NaCl/L constant draw solution, water and reverse salt fluxes up to 5.1 ± 1.0 L m-2 h-1 and 4.8 ± 2.6 g m-2 h-1 were observed, respectively. Positively, total and soluble chemical oxygen demand concentration factors of 2.47 ± 0.15 and 1.86 ± 0.08, respectively, were achieved, making wastewater more suitable for anaerobic treatment.

8.
Sci Total Environ ; 670: 993-1000, 2019 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-31018441

RESUMO

A laboratory scale anaerobic membrane bioreactor was operated for 11 months treating synthetic wastewater that mimicked the concentrate from a forward osmosis process treating municipal wastewater with 80% water recovery. The effect of temperature variation on reactor performance was assessed. The reactor operated during 4 months at 34 °C and then temperature was decreased to 23 °C, 17 °C and 15 °C mimicking the typical temperature seasonal variations of the sewage. Average COD removal efficiencies were 95, 87, 76 and 67% at 34, 23, 17 and 15 °C respectively, obtaining lower biogas production and lower COD removal at lower temperatures. Dissolved methane in the permeate averaged 8.2 mg CH4/L and did not significantly change with temperature. After 2 months operating at 15 °C, temperature was progressively increased, resulting in an immediate increase of methane production and COD removal efficiencies. Microbial analysis showed important changes in the archaeal community when temperature was changed from 34 to 23 °C.


Assuntos
Biocombustíveis/análise , Reatores Biológicos , Esgotos/análise , Eliminação de Resíduos Líquidos/métodos , Águas Residuárias/análise , Anaerobiose , Archaea/fisiologia , Membranas Artificiais , Microbiota , Esgotos/microbiologia , Águas Residuárias/microbiologia
9.
Chemosphere ; 217: 659-668, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30447613

RESUMO

Despite the number of studies that have investigated the fate of endocrine disrupting compounds (EDCs), to date results are still contradictory and more research is required to evaluate the contribution of the microbial communities present in different engineered treatment systems. Thus, autotrophic and heterotrophic types of biomass were here compared in terms of efficiency in the removal of estrone (E1), 17ß-estradiol (E2), estriol (E3), 17α-ethynilestradiol (EE2) and bisphenol A (BPA). Experiments were performed with enriched nitrifying activated sludge (NAS) and enriched ammonia oxidizing bacteria (AOB) sludge cultivated at lab-scale, as well as with conventional activated sludge (CAS) from a full-scale wastewater treatment plant. Both enriched NAS and AOB demonstrated a negligible degrading capacity. In both cases, the studied EDCs exhibited low removals (<14%) and showed no correlation with the increasing nitrification rates contradicting some of the hypothesis present in literature. Contrariwise, the biodegradation capabilities of the heterotrophic fraction of CAS were highlighted. E2 and E3 were removed by up to 100% and 78%, respectively. E1 was found to be the main transformation product of E2 (almost quantitative oxidation) and it was also highly eliminated. Finally, EE2 and BPA were more persistent biologically with removals ranging from 10% to 39%. For these two compounds similar removals were obtained during experiments with heat-inactivated biomass suggesting that sorption could be a relevant route of elimination.


Assuntos
Biodegradação Ambiental , Disruptores Endócrinos/isolamento & purificação , Processos Heterotróficos , Nitrificação , Biomassa , Disruptores Endócrinos/análise , Microbiota , Oxirredução , Esgotos/microbiologia , Águas Residuárias/química
10.
Membranes (Basel) ; 8(3)2018 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-30200413

RESUMO

Submerged forward osmosis (FO) is of high interest for bioreactors, such as osmotic membrane bioreactor, microalgae photobioreactor, food or bioproduct concentration where pumping through pressurized modules is a limitation due to viscosity or breakage of fragile components. However, so far, most FO efforts have been put towards cross flow configurations. This study provides, for the first time, insights on mass transfer limitations in the operation of submerged osmotic systems and offer recommendations for optimized design and operation. It is demonstrated that operation of the submerged plate and frame FO module requires draw circulation in the vacuum mode (vacuum assisted osmosis) that is in favor of the permeation flux. However, high pressure drops and dead zones occurring in classical U-shape FO draw channel strongly disadvantage this design; straight channel design proves to be more effective. External concentration polarization (ECP) is also a crucial element in the submerged FO process since mixing of the feed solution is not as optimized as in the cross flow module unless applying intense stirring. Among the mitigation techniques tested, air scouring proves to be more efficient than feed solution circulation. However, ECP mitigation methodology has to be adapted to application specificities with regards to combined/synergetic effects with fouling mitigation.

11.
Sci Total Environ ; 636: 519-529, 2018 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-29715656

RESUMO

Through their release of effluents, conventional wastewater treatment plants (WWTPs) represent a major pollution point sources for pharmaceutically active compounds (PhACs) in water bodies. The combination of a biological activated carbon (BAC) filter coupled with an ultrafiltration (UF) unit was evaluated as an advanced treatment for PhACs removal at pilot scale. The BAC-UF pilot plant was monitored for one year. The biological activity of the biofilm that developed on the granular activated carbon (GAC) particles and the contribution of this biofilm to the overall removal of PhACs were evaluated. Two different phases were observed during the long-term monitoring of PhACs removal. During the first 9200 bed volumes (BV; i.e., before GAC saturation), 89, 78, 83 and 79% of beta-blockers, psychiatric drugs, antibiotics and a mix of other therapeutic groups were removed, respectively. The second phase was characterized by deterioration of the overall performances during the period between 9200 and 13,800 BV. To quantify the respective contribution of adsorption and biodegradation, a lab-scale setup was operated for four months and highlighted the essential role played by GAC in biofiltration units. Physical adsorption was indeed the main removal mechanism. Nevertheless, a significant contribution due to biological activity was detected for some PhACs. The biofilm contributed to the removal of 22, 25, 30, 32 and 35% of ciprofloxacin, bezafibrate, ofloxacin, azithromycin and sulfamethoxazole, respectively.


Assuntos
Carvão Vegetal/química , Eliminação de Resíduos Líquidos/métodos , Águas Residuárias/química , Poluentes Químicos da Água/análise , Adsorção , Biodegradação Ambiental , Carbono , Purificação da Água
12.
Water Res ; 141: 65-73, 2018 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-29778066

RESUMO

Forward osmosis (FO) offers to be a very promising technology for the removal of trace organic compounds (TrOCs) from contaminated wastewater, and with the recent developments in FO membranes, the effect of both a higher water flux and reverse salt flux on the rejection of TrOCs needs to be explored. In this study two novel thin-film composite (TFC) membranes with greater water permeability and selectivity than the benchmark cellulose tri-acetate (CTA) membrane were compared at bench-scale in terms of TrOCs permeability. By probing the solute-membrane interactions that dictate the transport of TrOCs through the two membranes in the absence and presence of a draw solution, several conclusions were drawn. Firstly, steric hindrance is the main TrOCs transport -limiting mechanism through TFC membranes unless the negative membrane surface charge is significant, in which case, electrostatic interactions can dominate over steric hindrance. Secondly, the increase in ionic strength induced by the draw solution in the vicinity of and perhaps inside the membrane seems to favour the rejection of TrOCs by "shrinking" the membrane pores or by "shielding" the negative surface charge. Lastly, during FO operation, solute concentration polarisation becomes detrimental when working at high water fluxes, whereas the reverse solute flux has no direct impact on the transport of TrOCs through the membrane.


Assuntos
Celulose/análogos & derivados , Membranas Artificiais , Compostos Orgânicos/química , Poluentes Químicos da Água/química , Purificação da Água/instrumentação , Celulose/química , Concentração Osmolar , Osmose , Permeabilidade , Soluções , Eletricidade Estática , Águas Residuárias
13.
Sci Total Environ ; 624: 722-731, 2018 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-29272841

RESUMO

In the past few years, anaerobic ammonium oxidation-based processes have attracted a lot of attention for their implementation at the mainstream line of wastewater treatment plants, due to the possibility of leading to energy autarky if combined with anaerobic digestion. However, little is known about the potential degradation of micropollutants by the microbial groups responsible of these processes and the few results available are inconclusive. This study aimed to assess the degradation capability of biomass withdrawn from a combined nitritation/anaerobic ammonium oxidation (combined N/A) pilot plant towards five pharmaceutically active compounds (ibuprofen, sulfamethoxazole, metoprolol, venlafaxine and carbamazepine). Batch experiments were performed under different conditions by selectively activating or inhibiting different microbial groups: i) regular combined N/A operation, ii) aerobic (optimal for nitrifying bacteria), iii) aerobic with allylthiourea (an inhibitor of ammonia monooxygenase, enzyme of ammonia oxidizing bacteria), iv) anoxic (optimal for anaerobic ammonium oxidizing bacteria), v) aerobic with acetate (optimal for heterotrophic bacteria) and vi) anoxic with acetate (optimal for heterotrophic denitrifying bacteria). Ibuprofen was the most biodegradable compound being significantly degraded (49-100%) under any condition except heterotrophic denitrification. Sulfamethoxazole, exhibited the highest removal (70%) under optimal conditions for nitrifying bacteria but in the rest of the experiments anoxic conditions were found to be slightly more favorable (up to 58%). For metoprolol the highest performance was obtained under anoxic conditions favoring anammox bacteria (62%). Finally, carbamazepine and venlafaxine were hardly removed (≤10% in the majority of cases). Taken together, these results suggest the specificity of different microbial groups that in combination with alternating operational parameters can lead to enhanced removal of some micropollutants.


Assuntos
Bactérias Anaeróbias/metabolismo , Biodegradação Ambiental , Preparações Farmacêuticas/metabolismo , Compostos de Amônio , Anaerobiose , Biomassa , Reatores Biológicos , Nitrificação , Nitrogênio , Oxirredução
14.
Water Sci Technol ; 75(11-12): 2546-2553, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28617273

RESUMO

This paper proposes a model-based methodology that allows synthesising the most appropriate strategies for optimising the operation of wastewater treatment plants (WWTPs). The methodology is applied with the aim of maximising the nitrogen removal in membrane bioreactors (MBRs). The proposed procedure is based on a systematic approach composed of four steps. First, a sensitivity analysis of the input variables is carried out in order to obtain a first assessment of the potential for operational improvements. Then, the optimum input variable values are calculated by a model-based optimisation algorithm that minimises a cost function associated with the effluent total nitrogen at different temperatures. Then, the optimum operational strategies are identified. Finally, these operational strategies form the conceptual knowledge base for designing automatic control laws. The obtained optimal control strategies have shown a significant improvement in performance in comparison with fixed operation for the studied case, reducing the total nitrogen by 40%.


Assuntos
Reatores Biológicos , Nitrogênio/química , Eliminação de Resíduos Líquidos/métodos , Águas Residuárias/química , Membranas Artificiais , Modelos Teóricos , Eliminação de Resíduos Líquidos/instrumentação
15.
Water Sci Technol ; 75(11-12): 2562-2570, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28617275

RESUMO

The paper assesses the costs of full-scale membrane bioreactors (MBRs). Capital expenditures (CAPEX) and operating expenses (OPEX) of Spanish MBR facilities have been verified and compared to activated sludge plants (CAS) using water reclamation treatment (both conventional and advanced). Spanish MBR facilities require a production of 0.6 to 1.2 kWh per m3, while extended aeration (EA) and advanced reclamation treatment require 1.2 kWh per m3. The energy represents around 40% of the OPEX in MBRs. In terms of CAPEX, the implementation costs of a CAS facility followed by conventional water reclamation treatment (physical-chemical + sand filtration + disinfection) ranged from 730 to 850 €.m-3d, and from 1,050 to 1,250 €.m-3d in the case of advanced reclamation treatment facilities (membrane filtration) with a capacity of 8,000 to 15,000 m3d-1. The MBR cost for similar capacities ranges between 700 and 960 €.m-3d. This study shows that MBRs that have been recently installed represent a cost competitive option for water reuse applications for medium and large capacities (over 10,000 m3d-1), with similar OPEX to EA and conventional water reclamation treatment. In terms of CAPEX, MBRs are cheaper than EA, followed by advanced water reclamation treatment.


Assuntos
Reatores Biológicos/economia , Custos e Análise de Custo , Eliminação de Resíduos Líquidos/economia , Purificação da Água/economia , Filtração , Membranas Artificiais , Espanha , Eliminação de Resíduos Líquidos/instrumentação , Purificação da Água/instrumentação
16.
J Environ Manage ; 193: 503-511, 2017 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-28249760

RESUMO

Greywater is an important alternative water source, particularly in semi-arid, touristic areas, where the biggest water demand is usually in the dry period. By using this source wisely, tourist facilities can substantially reduce the pressure to scarce water resources. In densely urbanized touristic areas, where space has high value, compact solutions such as MBR based greywater reuse systems appear very appropriate. This research focuses on technical and economical evaluation of such solution by implementing a pilot MBR to a hotel with separated grey water. The pilot was operated for 6 months, with thorough characterisation of the GW performed, its operation was monitored and its energy consumption was optimized by applying a control system for the air scour. Based on the pilot operation a design and economic model was set to estimate the feasibility (CAPEX, OPEX, payback period of investment) of appropriate scales of MBR based GW systems, including separation of GW, MBR technology, clean water storage and disinfection. The model takes into account water and energy prices in Spain and a planning period of 20 years. The results demonstrated an excellent performance in terms of effluent quality, while the energy demand for air-scour was reduced by up to 35.2%, compared to the manufacturer recommendations. Economical evaluation of the entire MBR based GW reuse system shows its feasibility for sizes already at 5 m3/day (60 PE). The payback period of the investment for hotels like the demonstration hotel, treating 30 m3/day is 3 years.


Assuntos
Desinfecção , Eliminação de Resíduos Líquidos , Reatores Biológicos , Membranas Artificiais , Espanha , Purificação da Água
17.
Glob Chall ; 1(3): 1700009, 2017 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-31565269

RESUMO

Environmental decision support systems (EDSSs) are attractive tools to cope with the complexity of environmental global challenges. Several thoughtful reviews have analyzed EDSSs to identify the key challenges and best practices for their development. One of the major criticisms is that a wide and generalized use of deployed EDSSs has not been observed. The paper briefly describes and compares four case studies of EDSSs applied to the water domain, where the key aspects involved in the initial conception and the use and transfer evolution that determine the final success or failure of these tools (i.e., market uptake) are identified. Those aspects that contribute to bridging the gap between the EDSS science and the EDSS market are highlighted in the manuscript. Experience suggests that the construction of a successful EDSS should focus significant efforts on crossing the death-valley toward a general use implementation by society (the market) rather than on development.

18.
Water Res ; 102: 383-393, 2016 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-27393963

RESUMO

The removal of N-nitrosodimethylamine (NDMA) formation potential through a membrane bioreactor (MBR) coupled to a nanofiltration (NF) pilot plant that treats urban wastewater is investigated. The results are compared to the fate of the individual NDMA precursors detected: azithromycin, citalopram, erythromycin, clarithromycin, ranitidine, venlafaxine and its metabolite o-desmethylvenlafaxine. Specifically, the effect of dissolved oxygen in the aerobic chamber of the MBR pilot plant on the removal of NDMA formation potential (FP) and individual precursors is studied. During normal aerobic operation, implying a fully nitrifying system, the MBR was able to reduce NDMA precursors above 94%, however this removal percentage was reduced to values as low as 72% when changing the conditions to minimize nitrification. Removal decreased also for azithromycin (68-59%), citalopram (31-17%), venlafaxine (35-15%) and erythromycin (61-16%) on average during nitrifying versus non-nitrifying conditions. The removal of clarithromycin, o-desmethylvenlafaxine and ranitidine could not be correlated with the nitrification inhibition, as it varied greatly during the experiment time. The MBR pilot plant is coupled to a nanofiltration (NF) system and the results on the rejection of both, NDMA FP and individual precursors, through this system was above 90%. Finally, results obtained for the MBR pilot plant are compared to the percentage of removal by a conventional full scale biological wastewater treatment plant (WWTP) fed with the same influent. During aerobic operation, the removal of NDMA FP by the MBR pilot plant was similar to the full scale WWTP.


Assuntos
Dimetilnitrosamina , Águas Residuárias , Reatores Biológicos , Membranas Artificiais , Nitrificação , Eliminação de Resíduos Líquidos , Purificação da Água
19.
Membranes (Basel) ; 6(3)2016 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-27376337

RESUMO

Forward osmosis (FO) is a promising membrane technology to combine seawater desalination and water reuse. More specifically, in a FO-reverse osmosis (RO) hybrid process, high quality water recovered from the wastewater stream is used to dilute seawater before RO treatment. As such, lower desalination energy needs and/or water augmentation can be obtained while delivering safe water for direct potable reuse thanks to the double dense membrane barrier protection. Typically, FO-RO hybrid can be a credible alternative to new desalination facilities or to implementation of stand-alone water reuse schemes. However, apart from the societal (public perception of water reuse for potable application) and water management challenges (proximity of wastewater and desalination plants), FO-RO hybrid has to overcome technical limitation such as low FO permeation flux to become economically attractive. Recent developments (i.e., improved FO membranes, use of pressure assisted osmosis, PAO) demonstrated significant improvement in water flux. However, flux improvement is associated with drawbacks, such as increased fouling behaviour, lower rejection of trace organic compounds (TrOCs) in PAO operation, and limitation in FO membrane mechanical resistance, which need to be better considered. To support successful implementation of FO-RO hybrid in the industry, further work is required regarding up-scaling to apprehend full-scale challenges in term of mass transfer limitation, pressure drop, fouling and cleaning strategies on a module scale. In addition, refined economics assessment is expected to integrate fouling and other maintenance costs/savings of the FO/PAO-RO hybrid systems, as well as cost savings from any treatment step avoided in the water recycling.

20.
Environ Sci Pollut Res Int ; 23(14): 14431-41, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27068900

RESUMO

The occurrence of 32 pharmaceuticals and 14 UV filters in swimming pools and spas was studied. Fifty-one water samples were collected from 17 pools located in sport centres and hotels in Catalonia, Spain. The samples were analysed by liquid chromatography-tandem mass spectrometry. The pharmaceuticals atenolol, carbamazepine, hydrochlorothiazide, metronidazole, ofloxacin, sulfamethoxazole, acetaminophen, ibuprofen, ketoprofen and phenazone were measured in water samples at concentrations higher than their limit of quantification (LOQ). The highest concentration of any individual pharmaceutical was measured for the diuretic hydrochlorothiazide (904 ng/L). The most frequently detected pharmaceutical was carbamazepine, as it was observed in more than half of all the water samples measured (53 %, 27/51). The UV filters at concentrations higher than LOQ in water samples were BP1, BP2, BP3, BP8, THB, 4DHB, 4MBC, OD-PABA, 1HBT, MeBT and DMeBT. The highest concentration of UV filter observed was 4MBC (69.3 ng/L) while the most frequent UV filters in the samples were 1HBT (59 %, 30/51). The results also showed that pharmaceuticals and UV filters were most frequently found in spas. Finally, from a water treatment technology perspective, the lowest occurrence of pharmaceuticals was in the pools applying sand filters followed by disinfection by sodium hypochlorite, while the lowest occurrence of UV filters was in the pools applying coagulation, sand filtration, UV and salt electrolysis.


Assuntos
Poluentes Químicos da Água/análise , Atenolol/análise , Banhos , Carbamazepina/análise , Cromatografia Líquida de Alta Pressão , Extração em Fase Sólida , Piscinas , Espectrometria de Massas em Tandem , Raios Ultravioleta , Purificação da Água/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA