Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
2.
J Clin Microbiol ; 55(8): 2413-2421, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-28539343

RESUMO

BacT/Alert Virtuo is an advanced, automated blood culture system incorporating improved automation and an enhanced detection algorithm to shorten time to detection. A multicenter study of the investigational Virtuo system (bioMérieux, Inc., Durham, NC) compared to BacT/Alert 3D (BTA3D) for detection of bacteremia/fungemia in four bottle types, SA and FA Plus (aerobic) and SN and FN Plus (anaerobic), was performed in a clinical setting with patient samples in a matched system design clinical trial. Blood was added to paired aerobic or anaerobic bottles, with the volume in each bottle in each pair required to be ≤10 ml and with the volumes required to be within 30% of each other. Of 5,709 bottle sets (52.5% aerobic pairs and 47.5% anaerobic pairs), 430 (7.5%) were positive for bacterial or fungal growth, with 342 (6.0%) clinically significant and 83 (1.5%) contaminated. A total of 3,539 sets (62.0%) were volume compliant, with 203 sets (5.7%) clinically significant. The positivity rates for volume-compliant bottle pairs determined by the two systems were comparable, with 68.7% of clinically significant isolates detected by both instruments, 15.7% by Virtuo only, and 15.7% by BTA3D only. Virtuo detected microbial growth nearly 2 h sooner overall than BTA3D (mean, 15.9 h versus 17.7 h). Shorter time to detection by Virtuo was related to organism group, with the time to detection being significantly shorter for enteric Gram-negative bacilli and enterococci (means, 3.6 h and 2.3 h shorter, respectively). This large clinical study demonstrated that the Virtuo blood culture system produced results comparable to those seen with the long-established BTA3D system, with significantly shorter time to detection.


Assuntos
Automação Laboratorial/métodos , Bacteriemia/diagnóstico , Hemocultura/métodos , Fungemia/diagnóstico , Aerobiose , Anaerobiose , Humanos , Fatores de Tempo
3.
Transfusion ; 53(11): 2690-6, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23461309

RESUMO

BACKGROUND: Microbial contamination of hematopoietic progenitor cells (HPCs) and other regenerative cells used in transplantation and regenerative medicine can occur during collection and after in vitro manipulation, including purging, cryopreservation, thawing, and infusion. STUDY DESIGN AND METHODS: Microbiologic culture findings on consecutive HPCs and other cell preparations at a single institution derived from peripheral blood, marrow, cord blood, and mesenchymal stromal cells during all phases of manipulation were retrospectively examined from 2005 through 2011. Results were classified as confirmed positive, false positive, and indeterminate. RESULTS: During the 6-year surveillance period, 365 patients underwent 912 procedures involving HPC or other cell-based transfusion. True positive microbial contamination was found in five of 663 (0.8%) peripheral blood and two of 34 (5.9%) marrow preparations (p = 0.04), while no contamination was found in 118 preparations from other sources. True-positive microbial contaminants included coagulase-negative staphylococci in autologous HPC products derived from peripheral blood from two patients with asymptomatic central venous catheter infections at time of apheresis and Propionibacterium acnes in one apheresis and two marrow products. Organism loads were low in all cases (≤500 colony-forming units/mL), and no adverse sequelae occurred in four patients that received contaminated products. CONCLUSION: The incidence of microbial contamination of progenitor cell products in our institution over a 6-year period was low (0.8% overall), with contaminants originating from infected central venous catheters or from skin flora. All contaminants were bacterial species of low virulence, present in low titers and, if transfused, did not result in adverse reactions.


Assuntos
Bactérias/isolamento & purificação , Transplante de Células-Tronco Hematopoéticas , Células-Tronco Hematopoéticas/microbiologia , Medicina Regenerativa , Remoção de Componentes Sanguíneos , Humanos , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA