Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros








Intervalo de ano de publicação
1.
PLoS One ; 18(3): e0283039, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36928465

RESUMO

INTRODUCTION: General anesthesia is associated with the development of atelectasis, which may affect lung ventilation. Electrical impedance tomography (EIT) is a noninvasive imaging tool that allows monitoring in real time the topographical changes in aeration and ventilation. OBJECTIVE: To evaluate the pattern of distribution of pulmonary ventilation through EIT before and after anesthesia induction in pediatric patients without lung disease undergoing nonthoracic surgery. METHODS: This was a prospective observational study including healthy children younger than 5 years who underwent nonthoracic surgery. Monitoring was performed continuously before and throughout the surgical period. Data analysis was divided into 5 periods: induction (spontaneous breathing, SB), ventilation-5min, ventilation-30min, ventilation-late and recovery-SB. In addition to demographic data, mechanical ventilation parameters were also collected. Ventilation impedance (Delta Z) and pulmonary ventilation distribution were analyzed cycle by cycle at the 5 periods. RESULTS: Twenty patients were included, and redistribution of ventilation from the posterior to the anterior region was observed with the beginning of mechanical ventilation: on average, the percentage ventilation distribution in the dorsal region decreased from 54%(IC95%:49-60%) to 49%(IC95%:44-54%). With the restoration of spontaneous breathing, ventilation in the posterior region was restored. CONCLUSION: There were significant pulmonary changes observed during anesthesia and controlled mechanical ventilation in children younger than 5 years, mirroring the findings previously described adults. Monitoring these changes may contribute to guiding the individualized settings of the mechanical ventilator with the goal to prevent postoperative complications.


Assuntos
Respiração Artificial , Tomografia , Adulto , Humanos , Criança , Respiração Artificial/métodos , Impedância Elétrica , Tomografia/métodos , Ventilação Pulmonar , Pulmão/diagnóstico por imagem , Anestesia Geral/efeitos adversos
2.
Pediatr Pulmonol ; 57(11): 2681-2687, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35931651

RESUMO

OBJECTIVES: To evaluate the effects of four flow rates on the functional residual capacity (FRC) and pulmonary ventilation distribution while using a high-flow nasal cannula (HFNC). WORKING HYPOTHESIS: Our hypothesis is that flow rates below 1.5 L·kg-1 ·min-1 lead to FRC loss and respiratory distress. STUDY DESIGN: A single-center, prospective clinical study. PATIENT SELECTION: Infants diagnosed with acute viral bronchiolitis were given HFNC. METHODOLOGY: Through a prospective clinical study, the effects of four different flow rates, 2.0, 1.5, 1.0, and 0.5 L·kg-1 ·min-1 , on FRC and the pulmonary ventilation pattern were evaluated using electrical impedance tomography. The impedance variation (delta Z), end-expiratory lung volume (EELZ), respiratory rate, heart rate, respiratory distress score, and saturation/fraction of inspired oxygen ratio (SpO2 /FI O2 ), were also evaluated at each flow rate. RESULTS: Among the 11 infants included, There was a decrease in respiratory distress score at a flow rate of 1.5 L·kg-1 ·min-1 (*p = 0.021), and at a flow rate of 2.0 L·kg-1 ·min-1 (**p = 0.003) compared to 0.5 L·kg-1 ·min-1 . There was also a small but significant increase in SpO2 /FiO2 at flow rates of 1.5 (*p = 0.023), and 2.0 L·kg-1 ·min-1 (**p = 0.008) compared to 0.5 L·kg-1 ·min-1 . There were no other significant changes in the clinical parameters. In the global EELZ measurements, there was a significant increase under a flow rate of 2.0 L·kg-1 ·min-1 as compared to 0.5 L·kg-1 ·min-1 (p = 0.03). In delta Z values, there were no significant variations between the different flow rates. CONCLUSION: The ∆EELZ increases at the highest flow rates were accompanied by decreased distress scores and improved oxygenation.


Assuntos
Bronquiolite , Síndrome do Desconforto Respiratório , Bronquiolite/terapia , Cânula , Impedância Elétrica , Humanos , Lactente , Medidas de Volume Pulmonar , Oxigênio , Oxigenoterapia , Estudos Prospectivos , Tomografia
3.
BMC Pulm Med ; 21(1): 357, 2021 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-34749685

RESUMO

INTRODUCTION: Electrical impedance tomography (EIT) is a noninvasive, radiation-free, bedside tool to monitor ventilation distribution in real time. OBJECTIVE: To evaluate, in pediatric COVID-19 patients, the ventilation distribution using EIT and compare it to thoracic computed tomography (TCT) or chest radiograph results obtained in these patients. METHODS: This was a prospective, observational clinical study including pediatric patients admitted to the intensive care unit of a private hospital. The patients monitored with EIT tested positive for COVID-19 and were submitted to the previously mentioned radiation exams. EIT monitoring lasted 15 min and no sedation was used. RESULTS: Six patients were included in this study. The main differences observed in the EIT were in the right-left distribution and were compatible with the morphological changes found in the TCT or radiograph images due to COVID-19 infection. CONCLUSION: We conclude that EIT is ready to investigate the ventilatory profile present at different lung diseases, including COVID-19, and might postpone or mitigate the need of repeated ionizing radiation exams in the pediatric population, although larger pediatric cohorts comparing to standard radiological imaging are needed.


Assuntos
COVID-19/diagnóstico por imagem , Impedância Elétrica , Tomografia/métodos , COVID-19/terapia , Criança , Feminino , Humanos , Lactente , Masculino , Estudos Prospectivos
6.
Clinics (Sao Paulo) ; 63(2): 237-44, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18438579

RESUMO

INTRODUCTION: Studies comparing high frequency oscillatory and conventional ventilation in acute respiratory distress syndrome have used low values of positive end-expiratory pressure and identified a need for better recruitment and pulmonary stability with high frequency. OBJECTIVE: To compare conventional and high frequency ventilation using the lower inflection point of the pressure-volume curve as the determinant of positive end-expiratory pressure to obtain similar levels of recruitment and alveolar stability. METHODS: After lung lavage of adult rabbits and lower inflection point determination, two groups were randomized: conventional (positive end-expiratory pressure = lower inflection point; tidal volume=6 ml/kg) and high frequency ventilation (mean airway pressures= lower inflection point +4 cmH2O). Blood gas and hemodynamic data were recorded over 4 h. After sacrifice, protein analysis from lung lavage and histologic evaluation were performed. RESULTS: The oxygenation parameters, protein and histological data were similar, except for the fact that significantly more normal alveoli were observed upon protective ventilation. High frequency ventilation led to lower PaCO2 levels. DISCUSSION: Determination of the lower inflection point of the pressure-volume curve is important for setting the minimum end expiratory pressure needed to keep the airways opened. This is useful when comparing different strategies to treat severe respiratory insufficiency, optimizing conventional ventilation, improving oxygenation and reducing lung injury. CONCLUSIONS: Utilization of the lower inflection point of the pressure-volume curve in the ventilation strategies considered in this study resulted in comparable efficacy with regards to oxygenation and hemodynamics, a high PaCO2 level and a lower pH. In addition, a greater number of normal alveoli were found after protective conventional ventilation in an animal model of acute respiratory distress syndrome.


Assuntos
Modelos Animais de Doenças , Ventilação de Alta Frequência , Respiração com Pressão Positiva/métodos , Síndrome do Desconforto Respiratório , Análise de Variância , Animais , Gasometria , Lavagem Broncoalveolar , Distribuição de Qui-Quadrado , Ventilação de Alta Frequência/efeitos adversos , Pulmão/patologia , Complacência Pulmonar , Respiração com Pressão Positiva/efeitos adversos , Coelhos , Distribuição Aleatória , Síndrome do Desconforto Respiratório/patologia , Síndrome do Desconforto Respiratório/fisiopatologia , Síndrome do Desconforto Respiratório/terapia , Volume de Ventilação Pulmonar/fisiologia , Fatores de Tempo
7.
Clinics ; Clinics;63(2): 237-244, 2008. graf, tab
Artigo em Inglês | LILACS | ID: lil-481054

RESUMO

INTRODUCTION: Studies comparing high frequency oscillatory and conventional ventilation in acute respiratory distress syndrome have used low values of positive end-expiratory pressure and identified a need for better recruitment and pulmonary stability with high frequency. OBJECTIVE: To compare conventional and high frequency ventilation using the lower inflection point of the pressure-volume curve as the determinant of positive end-expiratory pressure to obtain similar levels of recruitment and alveolar stability. METHODS: After lung lavage of adult rabbits and lower inflection point determination, two groups were randomized: conventional (positive end-expiratory pressure = lower inflection point; tidal volume=6 ml/kg) and high frequency ventilation (mean airway pressures= lower inflection point +4 cmH2O). Blood gas and hemodynamic data were recorded over 4 h. After sacrifice, protein analysis from lung lavage and histologic evaluation were performed. RESULTS: The oxygenation parameters, protein and histological data were similar, except for the fact that significantly more normal alveoli were observed upon protective ventilation. High frequency ventilation led to lower PaCO2 levels. DISCUSSION: Determination of the lower inflection point of the pressure-volume curve is important for setting the minimum end expiratory pressure needed to keep the airways opened. This is useful when comparing different strategies to treat severe respiratory insufficiency, optimizing conventional ventilation, improving oxygenation and reducing lung injury. CONCLUSIONS: Utilization of the lower inflection point of the pressure-volume curve in the ventilation strategies considered in this study resulted in comparable efficacy with regards to oxygenation and hemodynamics, a high PaCO2 level and a lower pH. In addition, a greater number of normal alveoli were found after protective conventional ventilation in an animal model of acute respiratory distress syndrome.


Assuntos
Animais , Coelhos , Modelos Animais de Doenças , Ventilação de Alta Frequência , Respiração com Pressão Positiva/métodos , Síndrome do Desconforto Respiratório , Análise de Variância , Gasometria , Lavagem Broncoalveolar , Distribuição de Qui-Quadrado , Ventilação de Alta Frequência/efeitos adversos , Complacência Pulmonar , Pulmão/patologia , Respiração com Pressão Positiva/efeitos adversos , Distribuição Aleatória , Síndrome do Desconforto Respiratório/patologia , Síndrome do Desconforto Respiratório/fisiopatologia , Síndrome do Desconforto Respiratório/terapia , Fatores de Tempo , Volume de Ventilação Pulmonar/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA