Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 176
Filtrar
1.
Phys Rev Lett ; 131(22): 221801, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-38101357

RESUMO

Using an 185-kg NaI[Tl] array, COHERENT has measured the inclusive electron-neutrino charged-current cross section on ^{127}I with pion decay-at-rest neutrinos produced by the Spallation Neutron Source at Oak Ridge National Laboratory. Iodine is one the heaviest targets for which low-energy (≤50 MeV) inelastic neutrino-nucleus processes have been measured, and this is the first measurement of its inclusive cross section. After a five-year detector exposure, COHERENT reports a flux-averaged cross section for electron neutrinos of 9.2_{-1.8}^{+2.1}×10^{-40} cm^{2}. This corresponds to a value that is ∼41% lower than predicted using the MARLEY event generator with a measured Gamow-Teller strength distribution. In addition, the observed visible spectrum from charged-current scattering on ^{127}I has been measured between 10 and 55 MeV, and the exclusive zero-neutron and one-or-more-neutron emission cross sections are measured to be 5.2_{-3.1}^{+3.4}×10^{-40} and 2.2_{-0.5}^{+0.4}×10^{-40} cm^{2}, respectively.

2.
Phys Rev Lett ; 131(4): 041003, 2023 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-37566859

RESUMO

We report on the first search for nuclear recoils from dark matter in the form of weakly interacting massive particles (WIMPs) with the XENONnT experiment, which is based on a two-phase time projection chamber with a sensitive liquid xenon mass of 5.9 ton. During the (1.09±0.03) ton yr exposure used for this search, the intrinsic ^{85}Kr and ^{222}Rn concentrations in the liquid target are reduced to unprecedentedly low levels, giving an electronic recoil background rate of (15.8±1.3) events/ton yr keV in the region of interest. A blind analysis of nuclear recoil events with energies between 3.3 and 60.5 keV finds no significant excess. This leads to a minimum upper limit on the spin-independent WIMP-nucleon cross section of 2.58×10^{-47} cm^{2} for a WIMP mass of 28 GeV/c^{2} at 90% confidence level. Limits for spin-dependent interactions are also provided. Both the limit and the sensitivity for the full range of WIMP masses analyzed here improve on previous results obtained with the XENON1T experiment for the same exposure.

3.
Phys Rev Lett ; 130(26): 261002, 2023 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-37450817

RESUMO

Multiple viable theoretical models predict heavy dark matter particles with a mass close to the Planck mass, a range relatively unexplored by current experimental measurements. We use 219.4 days of data collected with the XENON1T experiment to conduct a blind search for signals from multiply interacting massive particles (MIMPs). Their unique track signature allows a targeted analysis with only 0.05 expected background events from muons. Following unblinding, we observe no signal candidate events. This Letter places strong constraints on spin-independent interactions of dark matter particles with a mass between 1×10^{12} and 2×10^{17} GeV/c^{2}. In addition, we present the first exclusion limits on spin-dependent MIMP-neutron and MIMP-proton cross sections for dark matter particles with masses close to the Planck scale.

4.
Phys Rev Lett ; 130(5): 051803, 2023 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-36800477

RESUMO

The COHERENT Collaboration searched for scalar dark matter particles produced at the Spallation Neutron Source with masses between 1 and 220 MeV/c^{2} using a CsI[Na] scintillation detector sensitive to nuclear recoils above 9 keV_{nr}. No evidence for dark matter is found and we thus place limits on allowed parameter space. With this low-threshold detector, we are sensitive to coherent elastic scattering between dark matter and nuclei. The cross section for this process is orders of magnitude higher than for other processes historically used for accelerator-based direct-detection searches so that our small, 14.6 kg detector significantly improves on past constraints. At peak sensitivity, we reject the flux consistent with the cosmologically observed dark-matter concentration for all coupling constants α_{D}<0.64, assuming a scalar dark-matter particle. We also calculate the sensitivity of future COHERENT detectors to dark-matter signals which will ambitiously test multiple dark-matter spin scenarios.

5.
Phys Rev Lett ; 129(16): 161805, 2022 Oct 14.
Artigo em Inglês | MEDLINE | ID: mdl-36306777

RESUMO

We report on a blinded analysis of low-energy electronic recoil data from the first science run of the XENONnT dark matter experiment. Novel subsystems and the increased 5.9 ton liquid xenon target reduced the background in the (1, 30) keV search region to (15.8±1.3) events/(ton×year×keV), the lowest ever achieved in a dark matter detector and ∼5 times lower than in XENON1T. With an exposure of 1.16 ton-years, we observe no excess above background and set stringent new limits on solar axions, an enhanced neutrino magnetic moment, and bosonic dark matter.

6.
Phys Rev Lett ; 129(8): 081801, 2022 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-36053683

RESUMO

We measured the cross section of coherent elastic neutrino-nucleus scattering (CEvNS) using a CsI[Na] scintillating crystal in a high flux of neutrinos produced at the Spallation Neutron Source at Oak Ridge National Laboratory. New data collected before detector decommissioning have more than doubled the dataset since the first observation of CEvNS, achieved with this detector. Systematic uncertainties have also been reduced with an updated quenching model, allowing for improved precision. With these analysis improvements, the COHERENT Collaboration determined the cross section to be (165_{-25}^{+30})×10^{-40} cm^{2}, consistent with the standard model, giving the most precise measurement of CEvNS yet. The timing structure of the neutrino beam has been exploited to compare the CEvNS cross section from scattering of different neutrino flavors. This result places leading constraints on neutrino nonstandard interactions while testing lepton flavor universality and measures the weak mixing angle as sin^{2}θ_{W}=0.220_{-0.026}^{+0.028} at Q^{2}≈(50 MeV)^{2}.

7.
Eur Phys J C Part Fields ; 81(4): 337, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34720714

RESUMO

The selection of low-radioactive construction materials is of utmost importance for the success of low-energy rare event search experiments. Besides radioactive contaminants in the bulk, the emanation of radioactive radon atoms from material surfaces attains increasing relevance in the effort to further reduce the background of such experiments. In this work, we present the 222 Rn emanation measurements performed for the XENON1T dark matter experiment. Together with the bulk impurity screening campaign, the results enabled us to select the radio-purest construction materials, targeting a 222 Rn activity concentration of 10 µ Bq / kg in 3.2 t of xenon. The knowledge of the distribution of the 222 Rn sources allowed us to selectively eliminate problematic components in the course of the experiment. The predictions from the emanation measurements were compared to data of the 222 Rn activity concentration in XENON1T. The final 222 Rn activity concentration of ( 4.5 ± 0.1 ) µ Bq / kg in the target of XENON1T is the lowest ever achieved in a xenon dark matter experiment.

8.
Clin Proteomics ; 18(1): 23, 2021 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-34583636

RESUMO

BACKGROUND: Cardiovascular disease (CVD) is a common comorbidity in chronic obstructive pulmonary disease (COPD) and reduced lung function is an important risk factor for CVD and CVD-related death. However, the mechanisms behind the increased risk for CVD in COPD patients are not fully understood. METHODS: We examined the association between CVD- and inflammation-related serum biomarkers, and pulmonary function in a geriatric population. 266 biomarkers related to CVD and inflammation were analyzed in blood samples from 611 subjects aged 66-86 years who participated in the Good Aging in Skåne study. Serum levels were assessed by a proximity extension assay. Pulmonary function was measured using the lower limit of normality (LLN) spirometry criteria, i.e., forced expiratory volume in 1 s (FEV1)/forced vital capacity (FVC) < LLN. Logistic regression models were implemented and multiple comparisons were accounted for. RESULTS: 10.3% of the study participants fulfilled pulmonary function decline criteria according to LLN. Out of the 266 biomarkers, only plasminogen activator, urokinase receptor (PLAUR) was statistically significantly associated with decreased pulmonary function. We could not find a statistically significant association between pulmonary function decline and other biomarkers previously linked to COPD, such as interleukin 6, tumor necrosis factor and surfactant protein D. CONCLUSION: We found that serum levels of PLAUR are associated with pulmonary function decline in older adults. PLAUR is activated following inflammation and promotes matrix metallopeptidase (MMP) activation and extracellular matrix (ECM) degradation. This implies that PLAUR could play a role in the early phase of COPD pathogenesis.

9.
Phys Rev Lett ; 126(1): 012002, 2021 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-33480779

RESUMO

We report the first measurement of coherent elastic neutrino-nucleus scattering (CEvNS) on argon using a liquid argon detector at the Oak Ridge National Laboratory Spallation Neutron Source. Two independent analyses prefer CEvNS over the background-only null hypothesis with greater than 3σ significance. The measured cross section, averaged over the incident neutrino flux, is (2.2±0.7)×10^{-39} cm^{2}-consistent with the standard model prediction. The neutron-number dependence of this result, together with that from our previous measurement on CsI, confirms the existence of the CEvNS process and provides improved constraints on nonstandard neutrino interactions.

10.
J Gen Intern Med ; 36(3): 753-761, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33403622

RESUMO

BACKGROUND: Many studies have shown that low health literacy (HL) is associated with several adverse outcomes. In this study, we systematically reviewed the prevalence of low HL in Europe. METHODS: PubMed, Embase, and Scopus were searched. Cross-sectional studies conducted in the European Union (EU), published from 2000, investigating the prevalence of low HL in adults using a reliable tool, were included. Quality was assessed with the Newcastle-Ottawa Scale. Inverse-variance random effects methods were used to produce pooled prevalence estimates. A meta-regression analysis was performed to assess the association between low HL and the characteristics of the studies. RESULTS: The pooled prevalence of low HL ranged from of 27% (95% CI: 18-38%) to 48% (95% CI: 41-55%), depending on the literacy assessment method applied. Southern, Western, and Eastern EU countries had lower HL compared to northern Europe (ß: 0.87, 95% CI: 0.40-1.35; ß: 0.59, 95% CI: 0.25-0.93; and ß: 0.72, 95% CI: 0.06-1.37, respectively). The assessment method significantly influenced the pooled estimate: compared to word recognition items, using self-reported comprehensions items (ß: 0.61, 95% CI: 0.15-1.08), reading or numeracy comprehensions items (ß: 0.77, 95% CI: 0.24-1.31), or a mixed method (ß: 0.66, 95% CI: 0.01-1.33) found higher rates of low HL. Refugees had the lowest HL (ß: 1.59, 95% CI: 0.26-2.92). Finally, lower quality studies reported higher rates of low HL (ß: 0.56, 95% CI: 0.06-1.07). DISCUSSION: We found that low HL is a public health challenge throughout Europe, where one in every three to almost one in every two Europeans may not be able to understand essential health-related material. Additional research is needed to investigate the underlying causes and to develop remedies. PROSPERO REGISTRATION: CRD42019133377.


Assuntos
Letramento em Saúde , Adulto , Estudos Transversais , Europa (Continente)/epidemiologia , União Europeia , Humanos , Prevalência
12.
Neuroimage Clin ; 28: 102401, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32932053

RESUMO

BACKGROUND AND AIM: The basal ganglia are critical for planned locomotion, but their role in age-related gait slowing is not well known. Spontaneous regional co-activation of brain activity at rest, known as resting state connectivity, is emerging as a biomarker of functional neural specialization of varying human processes, including gait. We hypothesized that greater connectivity amongst regions of the basal ganglia would be associated with faster gait speed in the elderly. We further investigated whether this association was similar in strength to that of other risk factors for gait slowing, specifically white matter hyperintensities (WMH). METHODS: A cohort of 269 adults (79-90 years, 146 females, 164 White) were assessed for gait speed (m/sec) via stopwatch; brain activation during resting state functional magnetic resonance imaging, WMH, and gray matter volume (GMV) normalized by intracranial volume via 3T neuroimaging; and risk factors of poorer locomotion via clinical exams (body mass index (BMI), muscle strength, vision, musculoskeletal pain, cardiometabolic conditions, depressive symptoms, and cognitive function). To understand whether basal ganglia connectivity shows distinct clusters of connectivity, we conducted a k-means clustering analysis of regional co-activation among the substantia nigra, nucleus accumbens, subthalamic nucleus, putamen, pallidum, and caudate. We conducted two multivariable linear regression models: (1) with gait speed as the dependent variable and connectivity, demographics, WMH, GMV, and locomotor risk factors as independent variables and (2) with basal ganglia connectivity as the dependent variable and demographics, WMH, GMV, and locomotor risk factors as independent variables. RESULTS: We identified two clusters of basal ganglia connectivity: high and low without a distinct spatial distribution allowing us to compute an average connectivity index of the entire basal ganglia regional connectivity (representing a continuous measure). Lower connectivity was associated with slower gait, independent of other locomotor risk factors, including WMH; the coefficient of this association was similar to those of other locomotor risk factors. Lower connectivity was significantly associated with lower BMI and greater WMH. CONCLUSIONS: Lower resting state basal ganglia connectivity is associated with slower gait speed. Its contribution appears comparable to WMH and other locomotor risk factors. Future studies should assess whether promoting higher basal ganglia connectivity in older adults may reduce age-related gait slowing.


Assuntos
Doenças de Pequenos Vasos Cerebrais , Velocidade de Caminhada , Idoso , Gânglios da Base/diagnóstico por imagem , Feminino , Substância Cinzenta , Humanos , Imageamento por Ressonância Magnética , Fatores de Risco
13.
Zootaxa ; 4728(4): zootaxa.4728.4.1, 2020 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-32229881

RESUMO

The genus Setosella included to date six species. After revision, only four of these species were retained, i.e. S. vulnerata, S. cavernicola, S. folini and S. spiralis. The remaining two species were tentatively placed in Woodipora, W.? antilleana n. comb., and Andreella,  A.? fragilis n. comb. On the other hand, scanning electron microscopy examination of Mediterranean material, revealed the presence of three new species previously included in species complexes: S. cyclopensis n. sp. from the open-shelf, S. rossanae n. sp. from submarine caves, and S. alfioi n. sp. from deep-waters. The diagnosis of the genus was amended to include the occurrence of kenozooids in S. cyclopensis n. sp. and S. cavernicola, and of free-living ring-shaped and scorpioid colonies in S. folini and S. alfioi n. sp. All the seven species now in Setosella have present-day representatives; the geographic distribution of the genus is restricted to the NE Atlantic and adjacent seas; its stratigrafic distribution is rejuvenated to the late Tortonian-early Messinian of southern Italy and insular Greece, with only three species occasionally and discontinuously reported. All species are able to produce numerous, subsequent intramural buds and morphological differences seem to be consistently associated with exploitation of particular habitats and substrata.


Assuntos
Briozoários , Animais , Cavernas , Mar Mediterrâneo
14.
Mar Environ Res ; 159: 104955, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32250878

RESUMO

The study aimed at contributing to the knowledge of alternative stable states by evaluating the differences of mobile and sessile macro-zoobenthic assemblages between sea urchin barrens and macroalgal forests in coastal Mediterranean systems considering a large spatial scale. Six sites (100 s km apart) were selected: Croatia, Montenegro, Sicily (Italy), Sardinia (Italy), Tuscany (Italy), and Balearic Islands (Spain). A total of 531 taxa, 404 mobile and 127 sessile macro-invertebrates were recorded. Overall, 496 and 201 taxa were found in macroalgal forests and in barrens, respectively. The results of this large-scale descriptive study have met the expectation of lower macrofauna complexity and diversity in barrens rather than in macroalgal forests, and have allowed estimating the differences in levels of diversity and the consistency of variability across Mediterranean sites. Some peculiar patterns in barrens, related to both abundance of specific taxa and to high values of beta diversity, have been evidenced.


Assuntos
Ecossistema , Florestas , Animais , Biodiversidade , Croácia , Mar Mediterrâneo , Ouriços-do-Mar , Sicília , Espanha
15.
Phys Rev Lett ; 122(14): 141301, 2019 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-31050482

RESUMO

We report the first experimental results on spin-dependent elastic weakly interacting massive particle (WIMP) nucleon scattering from the XENON1T dark matter search experiment. The analysis uses the full ton year exposure of XENON1T to constrain the spin-dependent proton-only and neutron-only cases. No significant signal excess is observed, and a profile likelihood ratio analysis is used to set exclusion limits on the WIMP-nucleon interactions. This includes the most stringent constraint to date on the WIMP-neutron cross section, with a minimum of 6.3×10^{-42} cm^{2} at 30 GeV/c^{2} and 90% confidence level. The results are compared with those from collider searches and used to exclude new parameter space in an isoscalar theory with an axial-vector mediator.

16.
Phys Rev Lett ; 122(7): 071301, 2019 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-30848617

RESUMO

We present first results on the scalar coupling of weakly interacting massive particles (WIMPs) to pions from 1 t yr of exposure with the XENON1T experiment. This interaction is generated when the WIMP couples to a virtual pion exchanged between the nucleons in a nucleus. In contrast to most nonrelativistic operators, these pion-exchange currents can be coherently enhanced by the total number of nucleons and therefore may dominate in scenarios where spin-independent WIMP-nucleon interactions are suppressed. Moreover, for natural values of the couplings, they dominate over the spin-dependent channel due to their coherence in the nucleus. Using the signal model of this new WIMP-pion channel, no significant excess is found, leading to an upper limit cross section of 6.4×10^{-46} cm^{2} (90% confidence level) at 30 GeV/c^{2} WIMP mass.

17.
Phys Rev Lett ; 123(25): 251801, 2019 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-31922764

RESUMO

We report constraints on light dark matter (DM) models using ionization signals in the XENON1T experiment. We mitigate backgrounds with strong event selections, rather than requiring a scintillation signal, leaving an effective exposure of (22±3) tonne day. Above ∼0.4 keV_{ee}, we observe <1 event/(tonne day keV_{ee}), which is more than 1000 times lower than in similar searches with other detectors. Despite observing a higher rate at lower energies, no DM or CEvNS detection may be claimed because we cannot model all of our backgrounds. We thus exclude new regions in the parameter spaces for DM-nucleus scattering for DM masses m_{χ} within 3-6 GeV/c^{2}, DM-electron scattering for m_{χ}>30 MeV/c^{2}, and absorption of dark photons and axionlike particles for m_{χ} within 0.186-1 keV/c^{2}.

18.
Phys Rev Lett ; 123(24): 241803, 2019 Dec 13.
Artigo em Inglês | MEDLINE | ID: mdl-31922867

RESUMO

Direct dark matter detection experiments based on a liquid xenon target are leading the search for dark matter particles with masses above ∼5 GeV/c^{2}, but have limited sensitivity to lighter masses because of the small momentum transfer in dark matter-nucleus elastic scattering. However, there is an irreducible contribution from inelastic processes accompanying the elastic scattering, which leads to the excitation and ionization of the recoiling atom (the Migdal effect) or the emission of a bremsstrahlung photon. In this Letter, we report on a probe of low-mass dark matter with masses down to about 85 MeV/c^{2} by looking for electronic recoils induced by the Migdal effect and bremsstrahlung using data from the XENON1T experiment. Besides the approach of detecting both scintillation and ionization signals, we exploit an approach that uses ionization signals only, which allows for a lower detection threshold. This analysis significantly enhances the sensitivity of XENON1T to light dark matter previously beyond its reach.

19.
Zootaxa ; 4524(4): 401-439, 2018 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-30486103

RESUMO

Four cribrilinid bryozoans associated with deep-water corals (578-682 m depth) from the Great Bahama Bank slope, are described, two of them are new. The generic allocation of some species prompted us to raise the subgenera Puellina, Cribrilaria, and Glabrilaria to genus rank. The new combination Cribrilaria saginata (Winston, 2005) n. comb. is proposed. Genus Glabrilaria is reported from the NW Atlantic for the first time based on the description of Glabrilaria hirsuta Rosso n. sp. and Glabrilaria polita Rosso n. sp. The new genus Teresaspis Rosso n. gen. is erected, and Teresaspis lineata (Canu Bassler, 1928) n. comb. is proposed as its type species. The new genus Harmelinius Rosso n. gen. is erected for Cribrilina uniserialis (Harmelin, 1978). Both genera have uniserial colonies formed by slightly caudate zooids with extensive gymnocyst and a frontal shield of flattened costae. Teresaspis lineata n. comb., however, has costae with pelmatidia that are connected by few intercostal bridges and separated by intercostal spaces, four orificial costa-like processes with the proximal pair arching above the orifice, hyperstomial acleithral ovicells with a pseudoporous ooecium formed by the distal zooid or a kenozooid, two types of kenozooids (large with costate frontal shield and small with smooth shield and central opesia), and an ancestrula with costate frontal shield. Avicularia are apparently absent in this species. In contrast, the type species of Harmelinius Rosso n. gen. has costae lacking pelmatidia and which are separated by slit-like intercostal spaces. The hyperstomial cleithral ovicells have smooth ooecia with a median suture and without pseudopores, and are formed by a distal kenozooid associated with a small avicularium. Additional paired oral avicularia are occasionally present, as are large kenozooids with a central opesia. Oral spines or spine-like processes are absent. Taxonomy of the above reported cribrilinid genera is discussed in detail together with the geographic distribution of all mentioned taxa.


Assuntos
Antozoários , Briozoários , Animais , Bahamas , Ecossistema , Água
20.
Phys Rev Lett ; 121(11): 111302, 2018 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-30265108

RESUMO

We report on a search for weakly interacting massive particles (WIMPs) using 278.8 days of data collected with the XENON1T experiment at LNGS. XENON1T utilizes a liquid xenon time projection chamber with a fiducial mass of (1.30±0.01) ton, resulting in a 1.0 ton yr exposure. The energy region of interest, [1.4,10.6] keV_{ee} ([4.9,40.9] keV_{nr}), exhibits an ultralow electron recoil background rate of [82_{-3}^{+5}(syst)±3(stat)] events/(ton yr keV_{ee}). No significant excess over background is found, and a profile likelihood analysis parametrized in spatial and energy dimensions excludes new parameter space for the WIMP-nucleon spin-independent elastic scatter cross section for WIMP masses above 6 GeV/c^{2}, with a minimum of 4.1×10^{-47} cm^{2} at 30 GeV/c^{2} and a 90% confidence level.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA