Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.243
Filtrar
1.
Anaesthesia ; 2024 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-38345268

RESUMO

Aspiration of gastric contents is a recognised complication during all phases of anaesthesia. The risk of this event becomes more likely with repeated attempts at tracheal intubation. There is a lack of clinical data on the effectiveness of videolaryngoscopy relative to direct laryngoscopy rapid sequence intubation in the operating theatre. We hypothesised that the use of a videolaryngoscope during rapid sequence intubation would be associated with a higher first pass tracheal intubation success rate than conventional direct laryngoscopy. In this multicentre randomised controlled trial, 1000 adult patients requiring tracheal intubation for elective, urgent or emergency surgery were allocated randomly to airway management using a McGrath™ MAC videolaryngoscope (Medtronic, Minneapolis, MN, USA) or direct laryngoscopy. Both techniques used a Macintosh blade. First-pass tracheal intubation success was higher in patients allocated to the McGrath group (470/500, 94%) compared with those allocated to the direct laryngoscopy group (358/500, 71.6%), odds ratio (95%CI) 1.31 (1.23-1.39); p < 0.001. This advantage was observed in both trainees and consultants. Cormack and Lehane grade ≥ 3 view occurred less frequently in patients allocated to the McGrath group compared with those allocated to the direct laryngoscopy group (5/500, 1% vs. 94/500, 19%, respectively; p < 0.001). Tracheal intubation with a McGrath videolaryngoscope was associated with a lower rate of adverse events compared with direct laryngoscopy (13/500, 2.6% vs. 61/500, 12.2%, respectively; p < 0.001). These findings suggest that the McGrath videolaryngoscope is superior to a conventional direct laryngoscope for rapid sequence intubation in the operating theatre.

2.
Ophthalmologie ; 121(4): 272-281, 2024 Apr.
Artigo em Alemão | MEDLINE | ID: mdl-38252295

RESUMO

Endogenous Candida endophthalmitis is a rare but vision-threatening disease. In most cases, endogenous endophthalmitis caused by Candida species has a better prognosis than endogenous endophthalmitis caused by other fungal species or bacteria but the prognosis still depends heavily on the time required for diagnosis and subsequent treatment as well as the initial visual acuity. Suggestions for treatment algorithms have already been made in the past but binding guidelines in ophthalmology only exist sporadically due to the rarity of the disease. This review discusses the current knowledge on endogenous Candida endophthalmitis and draws conclusions from the current study situation.


Assuntos
Endoftalmite , Vitrectomia , Humanos , Endoftalmite/diagnóstico , Prognóstico , Bactérias , Candida
3.
Rev Sci Instrum ; 94(9)2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-37737696

RESUMO

We report on the commissioning of a full aperture backscatter diagnostics station for the kilojoule, nanosecond high repetition rate L4n laser operating at a wavelength of 527 nm at the Extreme Light Infrastructure (ELI) - Beamlines, Dolni Brezany, Czech Republic. Light scattered back from laser-plasma interaction into the cone of the final focusing lens is captured and split into different channels to measure the signatures of laser plasma instabilities from stimulated Brillouin scattering, stimulated Raman scattering, and two plasmon decay with respect to back scattered energy, its spectrum, and its temporal profile. The performance was confirmed in a commissioning experiment with more than 800 shots at laser intensities ranging from 0.5 × 1013 to 1.1 × 1015 W cm-2. These diagnostics are permanently installed at ELI Beamlines, and can be used to understand the details of laser-plasma interactions in experiments with kJ and 527 nm light. The large number of shots that can be collected in an experimental campaign will allow us to study the details of the laser-plasma interaction with a high level of confidence.

4.
Am J Med Genet A ; 191(9): 2312-2323, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37477275

RESUMO

Pierre Robin sequence (PRS) is frequently co-occurring with other non-PRS congenital anomalies. The types and the prevalence of anomalies co-occurring with PRS vary in the reported studies. The aims of this report was to study the types and the prevalence of the anomalies co-occurring with PRS in a well-studied population northeastern France. The types and the prevalence of anomalies co-occurring in cases with PRS were ascertained in all terminations of pregnancy, stillbirths and live births in 387,067 births occurring consecutively during the period 1979-2007 in the area covered by our registry of congenital anomalies which is population-based, 89 cases of PRS were registered during the study period with a prevalence of 2.29 per 10,000 births, 69.7% of the cases had associated non-PRS anomalies. Chromosomal abnormalities were present in 10 (11.2%) cases including three 22 q11.2 deletion. Non-chromosomal recognizable conditions were diagnosed in 27 cases (30.3%) including 10 Stickler syndrome, 8 Treacher Collins syndrome, 3 cases with short stature and 6 other syndromes. Multiple congenital anomalies (MCA) were present in 25 cases (28.1%). The most frequent MCA were in the ear, face and neck (35 out of 98 anomalies, 35.7%), cardiovascular (18 anomalies, 18.4%), musculoskeletal (11 anomalies, 11.2%), central nervous (7 anomalies, 7.1%), urinary (6 anomalies, 6.1%), and eye (6 anomalies, 6.1%) system. The high prevalence of associated anomalies justifies a thorough screening for other congenital anomalies in cases with PRS.


Assuntos
Anormalidades Múltiplas , Doenças do Tecido Conjuntivo , Síndrome de Pierre Robin , Gravidez , Feminino , Humanos , Síndrome de Pierre Robin/epidemiologia , Síndrome de Pierre Robin/genética , Anormalidades Múltiplas/epidemiologia , Anormalidades Múltiplas/genética , Aberrações Cromossômicas , França/epidemiologia
5.
Ophthalmologie ; 120(7): 779-790, 2023 Jul.
Artigo em Alemão | MEDLINE | ID: mdl-37318615

RESUMO

Mucous membrane pemphigoid refers to a heterogeneous group of autoimmune diseases with subepidermal blister formation that can affect all mucous membranes with varying frequencies. This is a rare disease without any geographic or sexual predisposition that is characterized by recurrent inflammation and progressive scarring. The specific diagnostics can be negative in up to 50% of cases. The diagnosis is predominantly made in patients aged 60-80 years. Ophthalmologists play an important role in the care of affected individuals as the conjunctiva is the second most frequent site of involvement. The treatment is often tedious and primarily consists of long-term systemic immunosuppression.


Assuntos
Penfigoide Mucomembranoso Benigno , Penfigoide Bolhoso , Humanos , Penfigoide Mucomembranoso Benigno/diagnóstico , Mucosa , Túnica Conjuntiva , Vesícula
6.
Ophthalmologie ; 120(5): 496-501, 2023 May.
Artigo em Alemão | MEDLINE | ID: mdl-37173600

RESUMO

Ocular mucous membrane pemphigoid is the manifestation of a systemic autoimmune disease. As autoantibodies circulating in the blood cannot be adequately treated by eye drops, systemic immunosuppressive treatment of this autoimmune disease naturally plays the most important role. Ophthalmic topical or even surgical procedures are only used as supportive measures or usually to control ocular complications that have developed. Patients with the typical clinical picture are treated causally with systemic immunosuppression causally, nurturing eye drops, as well as by minimally invasive surgery if complications arise, if possible in an inflammation-free state, in accordance with the guidelines if the diagnosis is positive but also if the biopsy and serology are repeatedly negative after exclusion of all differential diagnoses. Purely topical anti-inflammatory treatment is insufficient to prevent irreversible progression of scarring conjunctivitis. Corresponding treatment recommendations have been formulated in current European as well as German guidelines and are presented here as an overview.


Assuntos
Doenças Autoimunes , Penfigoide Mucomembranoso Benigno , Penfigoide Bolhoso , Humanos , Penfigoide Bolhoso/complicações , Penfigoide Mucomembranoso Benigno/diagnóstico , Doenças Autoimunes/complicações , Mucosa , Soluções Oftálmicas/uso terapêutico
8.
Ophthalmologie ; 120(5): 472-477, 2023 May.
Artigo em Alemão | MEDLINE | ID: mdl-37095414

RESUMO

Mucosal pemphigoid is a rare chronic autoimmune disease that also affects the eyes in more than two thirds of all cases. Especially in the early phase of the ocular manifestation, the findings are subtle and the disease is often not recognized. The aim of this article is to provide the clinical aspects of ocular mucosal pemphigoid so that timely diagnostics can be initiated when this disease is suspected.


Assuntos
Doenças Autoimunes , Penfigoide Mucomembranoso Benigno , Penfigoide Bolhoso , Humanos , Penfigoide Bolhoso/diagnóstico , Penfigoide Mucomembranoso Benigno/diagnóstico , Mucosa , Olho
9.
Ophthalmologie ; 120(5): 502-507, 2023 May.
Artigo em Alemão | MEDLINE | ID: mdl-37115219

RESUMO

Mucous membrane pemphigoid (MMP) is a rare disease that presents clinicians with a diagnostic and therapeutic challenge. The aim of this article is to present the German ocular pemphigoid register, which is a retrospective data collection and a collaborative network to improve the care of these patients. It was founded in 2020 and currently comprises 17 eye clinics/cooperation partners. An initial evaluation of the results shows a known epidemiological profile and an expected high proportion of patients with negative diagnostics (48.6%) despite a clinically suspected diagnosis. In this register study predominantly recruiting from eye clinics, the proportion of patients with a strictly ocular involvement was 65.4%. Also of interest was the high number of patients with glaucoma (22.3%) as the most frequent comorbidity. Based on the working group formed, a prospective survey will be conducted in the future, which enables a follow-up.


Assuntos
Penfigoide Mucomembranoso Benigno , Penfigoide Bolhoso , Humanos , Penfigoide Bolhoso/tratamento farmacológico , Estudos Retrospectivos , Estudos Prospectivos , Penfigoide Mucomembranoso Benigno/diagnóstico , Olho
10.
Exp Eye Res ; 227: 109356, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36563893

RESUMO

The most commonly used tissue substitute for ocular surface reconstruction is human amniotic membrane (AM). Because of its low biomechanical strength and intransparency there is a need to search for alternatives of consistent quality. This study, further explored the biocompatibility of Keratin Film (KF) and its ability to sustain corneal epithelial wound healing. In three equal groups of 5 New Zeeland white rabbits a 4 mm superficial keratectomy was created in the right eye. Five eyes received a KF, five a human AM graft and the remaining five no implant. All eyes were treated with ofloxacin and dexamethasone eye drops and followed up for 10 days. Corneal fluorescein staining, vascularization, and transparency were assessed using slit lamp biomicroscopy according to a standardized grading score during and at the end of follow-up. The corneal-scleral-button was excised and processed for histology. After 10 days all eyes which had received a KF showed complete epithelial healing and no signs of neovascularization. In the AM group 1 eye showed a persistent epithelial defect at day 10 and 2 eyes showed neovascularization at day 7 resolving at day 10. Transparency improved progressively both in the KF group as well as in the AM group towards the end of the follow. Histology showed a multilayer epithelium firmly adherent to the KF with no evidence of keratocyte migration or inflammatory reaction in the corneal stroma. In this study on rabbit eyes KF better supported corneal epithelial wound healing than amniotic membrane.


Assuntos
Córnea , Epitélio Corneano , Queratinas , Cicatrização , Animais , Humanos , Coelhos , Córnea/cirurgia , Substância Própria , Epitélio , Epitélio Corneano/fisiopatologia , Queratinas/administração & dosagem , Cicatrização/fisiologia
11.
Ocul Immunol Inflamm ; 31(1): 142-148, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34797735

RESUMO

BACKGROUND: In accordance with worldwide data, the Robert Koch Institute (RKI) has reported a constant increase of syphilis cases in Germany over the past decade. METHODS: We analysed the data of all patients, referred to a Department of Ophthalmology in a tertiary referral centre in Düsseldorf, Germany between 2008 and 2019, who were tested for syphilis. The epidemiologic, demographic, clinical, diagnostic and therapeutic data were retrieved from the records and evaluated in a retrospective, descriptive, non-comparative study. RESULTS: Syphilis serology was positive in 32/1840 (1.7%) patients, and was evenly distributed over this period. 26 (81.3%) were male, 19 (59.4%) belonged to a risk group. Ocular syphilis was the primary diagnosis for 29 patients (90.6%). The most frequent manifestation was uveitis (n = 20, 62.5%). By the end of therapy, 19 patients (59.4%) had an improved visual acuity. CONCLUSION: The incidence of ocular syphilis cases has remained stable over the last decade.


Assuntos
Infecções Oculares Bacterianas , Sífilis , Centros de Atenção Terciária , Feminino , Humanos , Masculino , Infecções Oculares Bacterianas/diagnóstico , Infecções Oculares Bacterianas/epidemiologia , Alemanha/epidemiologia , Oftalmologia , Estudos Retrospectivos , Sífilis/diagnóstico , Sífilis/epidemiologia , Sorodiagnóstico da Sífilis , Centros de Atenção Terciária/estatística & dados numéricos , Uveíte/epidemiologia , Encaminhamento e Consulta
12.
Phys Rev E ; 106(4-2): 045211, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36397600

RESUMO

A strong quasistationary magnetic field is generated in hollow targets with curved internal surface under the action of a relativistically intense picosecond laser pulse. Experimental data evidence the formation of quasistationary strongly magnetized plasma structures decaying on a hundred picoseconds timescale, with the magnetic field strength of the kilotesla scale. Numerical simulations unravel the importance of transient processes during the magnetic field generation and suggest the existence of fast and slow regimes of plasmoid evolution depending on the interaction parameters. The proposed setup is suited for perspective highly magnetized plasma application and fundamental studies.

13.
Phys Rev Lett ; 129(11): 114801, 2022 Sep 09.
Artigo em Inglês | MEDLINE | ID: mdl-36154426

RESUMO

Premature relativistic transparency of ultrathin, laser-irradiated targets is recognized as an obstacle to achieving a stable radiation pressure acceleration in the "light sail" (LS) mode. Experimental data, corroborated by 2D PIC simulations, show that a few-nm thick overcoat surface layer of high Z material significantly improves ion bunching at high energies during the acceleration. This is diagnosed by simultaneous ion and neutron spectroscopy following irradiation of deuterated plastic targets. In particular, copious and directional neutron production (significantly larger than for other in-target schemes) arises, under optimal parameters, as a signature of plasma layer integrity during the acceleration.

14.
Geophys Res Lett ; 49(3): e2021GL096069, 2022 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-35859568

RESUMO

Water storage plays an important role in mitigating heat and flooding in urban areas. Assessment of the water storage capacity of cities remains challenging due to the inherent heterogeneity of the urban surface. Traditionally, effective storage has been estimated from runoff. Here, we present a novel approach to estimate effective water storage capacity from recession rates of observed evaporation during precipitation-free periods. We test this approach for cities at neighborhood scale with eddy-covariance based latent heat flux observations from 14 contrasting sites with different local climate zones, vegetation cover and characteristics, and climates. Based on analysis of 583 drydowns, we find storage capacities to vary between 1.3 and 28.4 mm, corresponding to e-folding timescales of 1.8-20.1 days. This makes the urban storage capacity at least five times smaller than all the observed values for natural ecosystems, reflecting an evaporation regime characterized by extreme water limitation.

15.
Rev Sci Instrum ; 93(5): 053303, 2022 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-35649771

RESUMO

Image plates (IPs) are a popular detector in the field of laser driven ion acceleration, owing to their high dynamic range and reusability. An absolute calibration of these detectors to laser-driven protons in the routinely produced tens of MeV energy range is, therefore, essential. In this paper, the response of Fujifilm BAS-TR IPs to 1-40 MeV protons is calibrated by employing the detectors in high resolution Thomson parabola spectrometers in conjunction with a CR-39 nuclear track detector to determine absolute proton numbers. While CR-39 was placed in front of the image plate for lower energy protons, it was placed behind the image plate for energies above 10 MeV using suitable metal filters sandwiched between the image plate and CR-39 to select specific energies. The measured response agrees well with previously reported calibrations as well as standard models of IP response, providing, for the first time, an absolute calibration over a large range of proton energies of relevance to current experiments.

17.
Phys Rev E ; 105(5-2): 055206, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35706166

RESUMO

Laser-accelerated proton beams are applicable to several research areas within high-energy density science, including warm dense matter generation, proton radiography, and inertial confinement fusion, which all involve transport of the beam through matter. We report on experimental measurements of intense proton beam transport through plastic foam blocks. The intense proton beam was accelerated by the 10ps, 700J OMEGA EP laser irradiating a curved foil target, and focused by an attached hollow cone. The protons then entered the foam block of density 0.38g/cm^{3} and thickness 0.55 or 1.00mm. At the rear of the foam block, a Cu layer revealed the cross section of the intense beam via proton- and hot electron-induced Cu-K_{α} emission. Images of x-ray emission show a bright spot on the rear Cu film indicative of a forward-directed beam without major breakup. 2D fluid-PIC simulations of the transport were conducted using a unique multi-injection source model incorporating energy-dependent beam divergence. Along with postprocessed calculations of the Cu-K_{α} emission profile, simulations showed that protons retain their ballistic transport through the foam and are able to heat the foam up to several keV in temperature. The total experimental emission profile for the 1.0mm foam agrees qualitatively with the simulated profile, suggesting that the protons indeed retain their beamlike qualities.

18.
J Med Case Rep ; 16(1): 167, 2022 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-35449024

RESUMO

BACKGROUND: Retinal arterial occlusive events in young patients are rare. However, because of physiological multifactorial adaptations during pregnancy, retinal vascular occlusive disease may occur spontaneously. In addition, a patent foramen ovale is a risk factor for an ischemic thromboembolic event. Since fluorescein angiography, a central tool in the evaluation of these occlusions, should be avoided during pregnancy, optical coherence tomography angiography, a novel technique, offers a good opportunity for visualizing vascular perfusion of retinal tissue. CASE PRESENTATION: Here we present a case series of three patients (Caucasian, nonsmoker) who visited our clinic owing to acute visual impairment and central scotoma. Using regular optical coherence tomography and optical coherence tomography angiography, retinal vascular occlusions were detected, thus initiating the evaluation of systemic risk factors. We report two patients (30 and 32 years old) who developed cilioretinal artery occlusion but whose etiology differed: one was of thromboembolic origin associated with patent foramen ovale, while the other was caused by hemodynamic blockade secondary to central retinal vein occlusion. In both cases, optical coherence tomography angiography revealed reperfusion of the cilioretinal artery occlusion. However, transient ischemia led to retinal atrophy after a few weeks. In the third patient (32 years old), 8 weeks after onset of scotoma, optical coherence tomography angiography revealed atrophy of the middle layers and impaired perfusion in the deep capillary plexus, and thus a paracentral acute middle maculopathy was diagnosed. All patients regained normal visual acuity and had otherwise uncomplicated pregnancies, and laboratory blood tests did not reveal any defects or alterations. CONCLUSIONS: As shown here, optical coherence tomography angiography enables risk-free imaging of retinal vessel perfusion during pregnancy. Together with regular optical coherence tomography, it allows one to predict functional outcome according to the existing retinal occlusion-related atrophy.


Assuntos
Forame Oval Patente , Oclusão da Artéria Retiniana , Doenças Retinianas , Adulto , Atrofia/complicações , Atrofia/patologia , Feminino , Angiofluoresceinografia/métodos , Forame Oval Patente/complicações , Humanos , Isquemia/diagnóstico , Gravidez , Oclusão da Artéria Retiniana/diagnóstico por imagem , Oclusão da Artéria Retiniana/etiologia , Doenças Retinianas/etiologia , Vasos Retinianos/patologia , Escotoma , Tomografia de Coerência Óptica/métodos
19.
Graefes Arch Clin Exp Ophthalmol ; 260(8): 2605-2612, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35357547

RESUMO

BACKGROUND AND PURPOSE: Corneal fluorescein staining is one of the most important diagnostic tests in dry eye disease (DED). Nevertheless, the result of this examination is depending on the grader. So far, there is no method for an automated quantification of corneal staining commercially available. Aim of this study was to develop a software-assisted grading algorithm and to compare it with a group of human graders with variable clinical experience in patients with DED. METHODS: Fifty images of eyes stained with 2 µl of 2% fluorescein presenting different severity of superficial punctate keratopathy in patients with DED were taken under standardized conditions. An algorithm for detecting and counting superficial punctate keratitis was developed using ImageJ with a training dataset of 20 randomly picked images. Then, the test dataset of 30 images was analyzed (1) by the ImageJ algorithm and (2) by 22 graders, all ophthalmologists with different levels of experience. All graders evaluated the images using the Oxford grading scheme for corneal staining at baseline and after 6-8 weeks. Intrarater agreement was also evaluated by adding a mirrored version of all original images into the set of images during the 2nd grading. RESULTS: The count of particles detected by the algorithm correlated significantly (n = 30; p < 0.01) with the estimated true Oxford grade (Sr = 0,91). Overall human graders showed only moderate intrarater agreement (K = 0,426), while software-assisted grading was always the same (K = 1,0). Little difference was found between specialists and non-specialists in terms of intrarater agreement (K = 0,436 specialists; K = 0,417 non-specialists). The highest interrater agreement was seen with 75,6% in the most experienced grader, a cornea specialist with 29 years of experience, and the lowest was seen in a resident with 25,6% who had only 2 years of experience. CONCLUSION: The variance in human grading of corneal staining - if only small - is likely to have only little impact on clinical management and thus seems to be acceptable. While human graders give results sufficient for clinical application, software-assisted grading of corneal staining ensures higher consistency and thus is preferrable for re-evaluating patients, e.g., in clinical trials.


Assuntos
Síndromes do Olho Seco , Córnea , Síndromes do Olho Seco/diagnóstico , Fluoresceína , Humanos , Software , Coloração e Rotulagem
20.
Ophthalmologie ; 119(6): 552-560, 2022 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-35294593

RESUMO

BACKGROUND AND OBJECTIVES: Climate change is also an increasingly important issue in the healthcare system. Due to its anatomical and physiological nature, the eye is directly exposed to environmental influences and changes in a special way. METHODS: The current literature is used to illustrate the effects of climate-induced changes and the respective influences on the eye. A PubMed search (cut-off date 3 October 2021) using the search terms "climate change" or "planetary health" or "global health" and in each case "ophthalmology" or "eye" or "ocular" was used to determine the development of the number of publications between 2011 and 2021. RESULTS: Measurable effects of climate change are already evident in a wide variety of ophthalmological fields. The significance of this topic, for instance, is reflected in a relatively constant increase in the number of publications and an almost tenfold increase in the number of publications per year from 2011 to 2021. CONCLUSION: The impact of climate change on eye diseases and on the field of ophthalmology is multifaceted and could be expected to intensify in the coming years. Therefore, the interrelationships need to be further investigated in future studies, preferably on a large scale.


Assuntos
Mudança Climática , Saúde Global , Previsões
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA