Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 60
Filtrar
1.
Europace ; 26(9)2024 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-39210643

RESUMO

AIMS: The extravascular implantable cardioverter-defibrillator (EV ICD) has been shown to be safe and effective for patients at risk of sudden cardiac death, but little is known about EV ICD lead removal in humans. This analysis aimed to characterize the EV ICD lead removal experience thus far. METHODS AND RESULTS: This was a retrospective analysis of lead removals from the EV ICD Pilot, Pivotal, and Continued Access Studies. Patients with a successful EV ICD implant who underwent lead removal were included. The main objective was lead removal success. Ancillary objectives included characterizing technique used, procedure complications, and reimplantation status. An EV ICD system was successfully implanted in 347 patients across the 3 studies (25.9% female; 53.4 ± 13.3 years; left ventricular ejection fraction: 39.7 ± 15.9). Of these patients, 29 (8.4%) underwent lead removal with a mean lead dwell time of 12.6 ± 14.3 months (0.2-58.4). The main reason for lead removal was lead dislodgement (n = 9, 31.0%). Lead removal was successful in 27/29 (93.1%) cases [100% (19/19) success rate <1 year and 80% (8/10) success rate >1 year post-implant]. Simple traction was used in 22/26 (84.6%) and extraction tools in 4/26 (15.4%) successful cases where technique was known. No complications were reported for any of the removal procedures. All 11 EV ICD reimplant attempts were successful. CONCLUSION: Complete removal of the EV ICD lead was successful in 93.1% of cases, and simple traction was sufficient in most instances. Based on these results, lead removal from the substernal space was safe and achievable up to 3 years post-implant.


Assuntos
Desfibriladores Implantáveis , Remoção de Dispositivo , Humanos , Remoção de Dispositivo/métodos , Feminino , Pessoa de Meia-Idade , Masculino , Estudos Retrospectivos , Idoso , Adulto , Resultado do Tratamento , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/etiologia , Projetos Piloto , Fatores de Tempo , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/efeitos adversos
2.
Artigo em Inglês | MEDLINE | ID: mdl-39014965

RESUMO

BACKGROUND: Extravascular and leadless pacemakers are a new class of cardiac devices that may reduce the rate of complications common to traditional cardiac pacemakers with intracardiac leads. These devices also have the potential of expanding access to cardiac pacing therapy by simplifying the complexity and cost of implantation. The objective of this study is to evaluate the implantation, chronic safety, and performance of a novel subxiphoidal pacemaker. METHODS: This study is an open-label, non-randomized, early feasibility study. Ten patients indicated for implantation of a single-chamber ventricular pacemaker will be enrolled and implanted with the investigational device. The pacemaker will be inserted underneath the ribcage and clipped to the xiphoid process, with stimulation electrodes positioned on the cardiac pericardium. Patients will be programmed to chronic pacing; pacing capture threshold, sensing amplitude, and lead impedance will be measured at implant and regularly scheduled follow-up visits. 24-h Holter ECG and cardiac troponin will also be periodically measured. Adverse events will be recorded throughout the study period. CONCLUSION: This study is designed to assess the feasibility, safety, and chronic performance of a novel extravascular pacemaker, and will provide valuable data on whether this device has the potential to be a viable alternative to conventional pacemakers.

4.
Artigo em Inglês | MEDLINE | ID: mdl-38758466

RESUMO

BACKGROUND: Intravascular cardiac pacemakers are an established therapy for bradycardic indications. Recently, a new class of leadless pacemakers have mitigated some of the complications related to pacemaker leads. In this study, we evaluate the implantation and performance of a novel extravascular technology that delivers epicardial pacing through a subxiphoidal approach. METHODS: Fifteen patients undergoing non-emergent open-heart surgery were enrolled. A midline incision was made just below the xiphoid process, and substernal tunneling was used to create a pocket for the device and to access the anterior pericardium over the right ventricle. The test device (Calyan Technologies, Oakdale, MN) was temporarily inserted underneath the ribcage and clipped to the xiphoid process. The sensing and pacing electrode (FlexArm) was positioned on the anterior pericardium. Ventricular sensing and pacing capture thresholds were measured. RESULTS: The test device was successfully implanted in all 15 patients. There were no device or procedure-related adverse events. The first five implanted patients had no pacing capture at maximum stimulation intensity. Design changes were made to the device, including different electrode size and shape, and successful ventricular capture was achieved in 9 of the subsequent 10 patients. In these patients, pacing threshold was 3.8 ± 1.6 mA with a pulse width of 0.5 ms. All devices were successfully explanted at the end of the procedure. CONCLUSIONS: In a first-in-human experience with a novel extravascular pacemaker, this study demonstrated the feasibility of pericardial ventricular pacing via a subxiphoidal approach. Further chronic studies are required to evaluate the safety and performance of this novel pacing technology.

5.
Ann Nucl Med ; 38(5): 391-399, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38430406

RESUMO

OBJECTIVE: Papillary muscle (PM) activity may demonstrate true active cardiac sarcoidosis (CS) or mimic CS in 18FDG-PET/CT if adequate myocardial suppression (MS) is not achieved. We aim to examine whether PM uptake can be used as a marker of failed MS and measure the rate of PM activity presence in active CS with different dietary preparations. MATERIALS AND METHODS: We retrospectively reviewed PET/CTs obtained with three different dietary preparations. Diet-A: 24-h ketogenic diet with overnight fasting (n = 94); Diet-B: 18-h fasting (n = 44); and Diet-C: 72-h daytime ketogenic diet with 3-day overnight fasting (n = 98). Each case was evaluated regarding CS diagnosis (negative, positive, and indeterminant) and presence of PM activity. MaxSUV was measured from bloodpool, liver, and the most suppressed normal myocardium. Linear mixed-effects models were used to compare these factors between those with PM activity and those without. RESULTS: PM activity was markedly lower in the Diet-C group compared with others: Diet-C: 6 (6.1%), Diet-A: 36 (38.3%), and Diet-B: 26 (59.1%) (p < 0.001). MyocardiumMaxSUV was higher, and MyocardiummaxSUV/BloodpoolmaxSUV, MyocardiummaxSUV/LivermaxSUV ratios were significantly higher in the cases with PM activity (p < 0.001). Among cases that used Diet-C and had PM activity, 66.7% were positive and 16.7% were indeterminate. If Diet-A or Diet-B was used, those with PM activity had a higher proportion of indeterminate cases (Diet-A: 61.1%, Diet-B: 61.5%) than positive cases (Diet-A: 36.1%, Diet-B: 38.5%). CONCLUSION: Lack of PM activity can be a sign of appropriate MS. PM activity is less common with a specific dietary preparation (72-h daytime ketogenic diet with 3-day overnight fasting), and if it is present with this particular preparation, the likelihood that the case being true active CS might be higher than the other traditional dietary preparations.


Assuntos
Cardiomiopatias , Sarcoidose , Humanos , Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Músculos Papilares/diagnóstico por imagem , Estudos Retrospectivos , Tomografia por Emissão de Pósitrons , Sarcoidose/diagnóstico por imagem , Compostos Radiofarmacêuticos , Cardiomiopatias/diagnóstico por imagem
6.
Artigo em Inglês | MEDLINE | ID: mdl-38427181

RESUMO

BACKGROUND: Traditional cardiac pacemakers commonly have a range of complications related to the presence of intracardiac leads. A new class of extravascular and leadless pacemakers has recently emerged with the potential to mitigate these complications and expand access to cardiac pacing. The objective of this study is to evaluate the implantation, short-term chronic safety, and performance of a novel subxiphoidal extracardiac pacemaker. METHODS: Normal Yorkshire Cross swine (n = 16) were implanted with the subxiphoidal pacemaker. The pacemaker was inserted through a midline chest incision and clipped to the underside of the sternum, with the stimulation electrode placed on the anterior pericardium. Animals were chronically paced and followed for 90 days post-implant, with periodic measurement of pacing capture threshold (PCT) and electrode impedance. RESULTS: All 16 animals were successfully implanted with the study device. At implant, a consistent average PCT of 2.2 ± 0.4 V at a pulse width of 1.0 ms was observed in all animals, with an average implant impedance of 648 ± 44 Ω. Chronic pacing was programmed at a rate of 60 bpm, an amplitude of 3.4 ± 0.7 V, and a pulse width of 1.0 ms. PCT rose to 4.6 ± 0.8 V at 14 days and stabilized; at 90 days, PCT was 3.8 ± 1.2 V and electrode impedance was 533 ± 105 Ω. All implanted animals completed the study with no clinically significant findings, no clinically significant abnormalities, and with no adverse events that affected animal welfare. CONCLUSIONS: This study demonstrated the safety and feasibility of a novel subxiphoidal extracardiac pacemaker to deliver short-term chronic extravascular therapy. Further studies are required to assess the safety, feasibility, and long-term chronic pacing performance in human subjects.

7.
Indian Pacing Electrophysiol J ; 24(2): 84-93, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38340957

RESUMO

Myocardial scar in ischemic cardiomyopathy is predominantly endocardial, however, between 5% and 15% of these patients have an arrhythmogenic epicardial substrate. Percutaneous epicardial ablation should be considered in patients with ICM and VT especially if they failed an endocardial ablation. Simultaneous epicardial and endocardial ablation of VT in ICM may reduce short- and medium-term VT recurrence compared with an endocardial only approach. Cardiac imaging could be used to help guide patient selection for a combined epi-endo approach. Complications related to epicardial access can happen in up to 7% of patients. Epicardial ablation in these patients should be referred to experienced tertiary centers. We review the literature and share interesting cases.

8.
J Cardiovasc Electrophysiol ; 35(2): 230-237, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38047467

RESUMO

INTRODUCTION: The extravascular implantable cardioverter defibrillator (EV ICD) has extended projected battery longevity compared to the subcutaneous implantable cardioverter defibrillator (S-ICD). This study used modeling to characterize the need for generator changes, long-term complications, and overall costs for both the EV ICD and S-ICD in healthcare systems of various countries. METHODS: Battery longevity data were modeled using a Markov model from averages reported in device labeling for the S-ICD and with engineering estimates based on real life usage from EV ICD Pivotal Study patient data to introduce variability. Clinical demographic data were derived from published literature. The primary outcomes were defined as the number of generator replacement surgeries, complications, and total healthcare system costs due to battery depletion over the expected lifetime of patients receiving EV ICD or S-ICD therapy. RESULTS: Average modeled battery longevity was determined to be 7.3 years for the S-ICD versus 11.8 years for the EV ICD. The probability of a complication after a replacement procedure was 1.4%, with an operative mortality rate of 0.02%. The use of EV ICD was associated with 1.4-1.6 fewer replacements on average over an expected patient lifetime as compared to S-ICD and a 24.3%-26.0% reduction in cost. A one-way sensitivity analysis of the model for the US healthcare system found that use of an EV ICD resulted in a reduction in replacement surgeries of greater than 1 (1.1-1.6) along with five-figure cost savings in all scenarios ($18 602-$40 948). CONCLUSION: The longer projected battery life of the EV ICD has the potential to meaningfully reduce long-term morbidity and healthcare resources related to generator changes from the perspective of multiple diverse healthcare systems.


Assuntos
Desfibriladores Implantáveis , Humanos , Falha de Equipamento , Cardioversão Elétrica/efeitos adversos , Previsões , Redução de Custos
10.
Indian Pacing Electrophysiol J ; 23(6): 189-195, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37714513

RESUMO

Premature Ventricular Complexes (PVCs) refer to electrical activity arising from ventricles resulting in ventricular contraction independent of the native rhythm. PVCs by themselves are common in the general population but based on the origin of the PVCs, either related to anatomical or electrical substrate, the disease process has a widely varied presentation and prognosis. The clinical presentation of symptoms may vary from being extremely benign, or very severe (malignant). Benign PVCs include those that are asymptomatic or induce very mild symptoms including palpitations, lightheadedness, chest discomfort, or the sensation of skipped beats. The middle range of PVCs present as heart failure or heart failure complicated by PVCs. The malignant variety may present as syncope, or sudden cardiac death. In this review we describe the multiple facets of PVC presentation and strategies of clinical management.

11.
JACC Clin Electrophysiol ; 9(8 Pt 3): 1719-1729, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37227359

RESUMO

BACKGROUND: Multiple cardiac sarcoidosis (CS) diagnostic schemes have been published. OBJECTIVES: This study aims to evaluate the association of different CS diagnostic schemes with adverse outcomes. The diagnostic schemes evaluated were 1993, 2006, and 2017 Japanese criteria and the 2014 Heart Rhythm Society criteria. METHODS: Data were collected from the Cardiac Sarcoidosis Consortium, an international registry of CS patients. Outcome events were any of the following: all-cause mortality, left ventricular assist device placement, heart transplantation, and appropriate implantable cardioverter-defibrillator therapy. Logistic regression analysis evaluated the association of outcomes with each CS diagnostic scheme. RESULTS: A total of 587 subjects met the following criteria: 1993 Japanese (n = 310, 52.8%), 2006 Japanese (n = 312, 53.2%), 2014 Heart Rhythm Society (n = 480, 81.8%), and 2017 Japanese (n = 112, 19.1%). Patients who met the 1993 criteria were more likely to experience an event than patients who did not (n = 109 of 310, 35.2% vs n = 59 of 277, 21.3%; OR: 2.00; 95% CI: 1.38-2.90; P < 0.001). Similarly, patients who met the 2006 criteria were more likely to have an event than patients who did not (n = 116 of 312, 37.2% vs n = 52 of 275, 18.9%; OR: 2.54; 95% CI: 1.74-3.71; P < 0.001). There was no statistically significant association between the occurrence of an event and whether a patient met the 2014 or the 2017 criteria (OR: 1.39; 95% CI: 0.85-2.27; P = 0.18 or OR: 1.51; 95% CI: 0.97-2.33; P = 0.067, respectively). CONCLUSIONS: CS patients who met the 1993 and the 2006 criteria had higher odds of adverse clinical outcomes. Future research is needed to prospectively evaluate existing diagnostic schemes and develop new risk models for this complex disease.


Assuntos
Cardiomiopatias , Desfibriladores Implantáveis , Transplante de Coração , Miocardite , Sarcoidose , Humanos , Sarcoidose/diagnóstico , Sarcoidose/epidemiologia , Sarcoidose/complicações , Desfibriladores Implantáveis/efeitos adversos
12.
Entropy (Basel) ; 25(2)2023 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-36832698

RESUMO

Atrial Fibrillation (AF) is the most common cardiac arrhythmia. Signal-processing approaches are widely used for the analysis of intracardiac electrograms (iEGMs), which are collected during catheter ablation from patients with AF. In order to identify possible targets for ablation therapy, dominant frequency (DF) is widely used and incorporated in electroanatomical mapping systems. Recently, a more robust measure, multiscale frequency (MSF), for iEGM data analysis was adopted and validated. However, before completing any iEGM analysis, a suitable bandpass (BP) filter must be applied to remove noise. Currently, no clear guidelines for BP filter characteristics exist. The lower bound of the BP filter is usually set to 3-5 Hz, while the upper bound (BP¯th) of the BP filter varies from 15 Hz to 50 Hz according to many researchers. This large range of BP¯th subsequently affects the efficiency of further analysis. In this paper, we aimed to develop a data-driven preprocessing framework for iEGM analysis, and validate it based on DF and MSF techniques. To achieve this goal, we optimized the BP¯th using a data-driven approach (DBSCAN clustering) and demonstrated the effects of different BP¯th on subsequent DF and MSF analysis of clinically recorded iEGMs from patients with AF. Our results demonstrated that our preprocessing framework with BP¯th = 15 Hz has the best performance in terms of the highest Dunn index. We further demonstrated that the removal of noisy and contact-loss leads is necessary for performing correct data iEGMs data analysis.

13.
JAMA Cardiol ; 7(10): 1057-1066, 2022 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-36103165

RESUMO

Importance: In patients with sarcoidosis with suspected cardiac involvement, late gadolinium enhancement (LGE) on cardiovascular magnetic resonance imaging (CMR) identifies those with an increased risk of adverse outcomes. However, these outcomes are experienced by only a minority of patients with LGE, and identifying this subgroup may improve treatment and outcomes in these patients. Objective: To assess whether CMR phenotypes based on left ventricular ejection fraction (LVEF) and LGE in patients with suspected cardiac sarcoidosis (CS) are associated with adverse outcomes during follow-up. Design, Setting, and Participants: This cohort study included consecutive patients with histologically proven sarcoidosis who underwent CMR for the evaluation of suspected CS from 2004 to 2020 with a median follow-up of 4.3 years at an academic medical center in Minnesota. Demographic data, medical history, comorbidities, medications, and outcome data were collected blinded to CMR data. Exposures: CMR phenotypes were identified based on LVEF and LGE presence and features. LGE was classified as pathology-frequent or pathology-rare based on the frequency of cardiac damage features on gross pathology assessment of the hearts of patients with CS who had sudden cardiac death or cardiac transplant. Main Outcomes and Measures: Composite of ventricular arrhythmic events and composite of heart failure events. Results: Among 504 patients (mean [SD] age, 54.1 [12.5] years; 242 [48.0%] female and 262 [52.0%] male; 2 [0.4%] American Indian or Alaska Native, 6 [1.2%] Asian, 90 [17.9%] Black or African American, 399 [79.2%] White, 5 [1.0%] of 2 or more races (including the above-mentioned categories and Native Hawaiian or Other Pacific Islander), and 2 [0.4%] of unknown race; 4 [0.8%] Hispanic or Latino, 498 [98.8%] not Hispanic or Latino, and 2 [0.4%] of unknown ethnicity), 4 distinct CMR phenotypes were identified: normal LVEF and no LGE (n = 290; 57.5%), abnormal LVEF and no LGE (n = 53; 10.5%), pathology-frequent LGE (n = 103; 20.4%), and pathology-rare LGE (n = 58; 11.5%). The phenotype with pathology-frequent LGE was associated with a high risk of arrhythmic events (hazard ratio [HR], 12.12; 95% CI, 3.62-40.57; P < .001) independent of LVEF and extent of left ventricular late gadolinium enhancement (LVLGE). It was also associated with a high risk of heart failure events (HR, 2.49; 95% CI, 1.19-5.22; P = .02) independent of age, pulmonary hypertension, LVEF, right ventricular ejection fraction, and LVLGE extent. Risk of arrhythmic events was greater with an increasing number of pathology-frequent LGE features. The absence of the pathology-frequent LGE phenotype was associated with a low risk of arrhythmic events, even in the presence of LGE or abnormal LVEF. Conclusions and Relevance: This cohort study found that a CMR phenotype involving pathology-frequent LGE features was associated with a high risk of arrhythmic and heart failure events in patients with sarcoidosis. The findings indicate that CMR phenotypes could be used to optimize clinical decision-making for treatment options, such as implantable cardioverter-defibrillators.


Assuntos
Insuficiência Cardíaca , Miocardite , Sarcoidose , Estudos de Coortes , Meios de Contraste , Feminino , Gadolínio , Insuficiência Cardíaca/etiologia , Humanos , Imageamento por Ressonância Magnética/métodos , Imagem Cinética por Ressonância Magnética/métodos , Masculino , Fenótipo , Estudos Prospectivos , Sarcoidose/complicações , Sarcoidose/diagnóstico por imagem , Volume Sistólico , Função Ventricular Esquerda , Função Ventricular Direita
14.
J Am Heart Assoc ; 11(11): e023762, 2022 06 07.
Artigo em Inglês | MEDLINE | ID: mdl-35656998

RESUMO

Background Atrial and ventricular arrhythmias are commonly encountered in patients with advanced heart failure, with amiodarone being the most commonly used antiarrhythmic drug in continuous-flow left ventricular assist device (CF-LVAD) recipients. The purpose of this study was to assess the impact of amiodarone use on long-term all-cause mortality in ptients with a CF-LVAD. Methods and Results A retrospective multicenter study of CF-LVAD was conducted at 5 centers including all CF-LVAD implants from 2007 to 2015. Patients were stratified based on pre-CF-LVAD implant amiodarone use. Additional use of amiodarone after CF-LVAD implantation was also evaluated. Primary outcome was all-cause mortality during long-term follow-up. Kaplan-Meier curves were used to assess survival outcomes. Multivariable Cox regression was used to identify predictors of outcomes. Propensity matching was done to address baseline differences. A total of 480 patients with a CF-LVAD (aged 58±13 years, 81% men) were included. Of these, 170 (35.4%) were on chronic amiodarone therapy at the time of CF-LVAD implant, and 310 (64.6%) were not on amiodarone. Rate of all-cause mortality over the follow-up period was 32.9% in the amiodarone group compared with 29.6% in those not on amiodarone (P=0.008). Similar results were noted in the propensity-matched group (log-rank, P=0.04). On multivariable Cox regression analysis, amiodarone use at baseline was independently associated with all-cause mortality (hazard ratio, 1.68 [95% CI, 1.1-2.5]; P=0.01). Conclusions Amiodarone use was associated with significantly increased rates of all-cause mortality in CF-LVAD recipients. Earlier interventions for arrhythmias to avoid long-term amiodarone exposure may improve long-term outcomes in CF-LVAD recipients and needs further study.


Assuntos
Amiodarona , Insuficiência Cardíaca , Coração Auxiliar , Amiodarona/efeitos adversos , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/terapia , Feminino , Coração Auxiliar/efeitos adversos , Humanos , Masculino , Estudos Retrospectivos , Resultado do Tratamento
16.
JAMA Cardiol ; 7(2): 175-183, 2022 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-34787643

RESUMO

Importance: Ventricular tachycardia (VT) is associated with high mortality in patients with cardiac sarcoidosis (CS), and medical management of CS-associated VT is limited by high failure rates. The role of catheter ablation has been investigated in small, single-center studies. Objective: To investigate outcomes associated with VT ablation in patients with CS. Design, Setting, and Participants: This cohort study from the Cardiac Sarcoidosis Consortium registry (2003-2019) included 16 tertiary referral centers in the US, Europe, and Asia. A total of 158 consecutive patients with CS and VT were included (33% female; mean [SD] age, 52 [11] years; 53% with ejection fraction [EF] <50%). Exposures: Catheter ablation of CS-associated VT and, as appropriate, medical treatment. Main Outcomes and Measures: Immediate and short-term outcomes included procedural success, elimination of VT storm, and reduction in defibrillator shocks. The primary long-term outcome was the composite of VT recurrence, heart transplant (HT), or death. Results: Complete procedural success (no inducible VT postablation) was achieved in 85 patients (54%). Sixty-five patients (41%) had preablation VT storm that did not recur postablation in 53 (82%). Defibrillator shocks were significantly reduced from a median (IQR) of 2 (1-5) to 0 (0-0) in the 30 days before and after ablation (P < .001). During median (IQR) follow-up of 2.5 (1.1-4.9) years, 73 patients (46%) experienced VT recurrence and 81 (51%) experienced the composite primary outcome. One- and 2-year rates of survival free of VT recurrence, HT, or death were 60% and 52%, respectively. EF less than 50% and myocardial inflammation on preprocedural 18F-fluorodeoxyglucose positron emission tomography were significantly associated with adverse prognosis in multivariable analysis for the primary outcome (HR, 2.24; 95% CI, 1.37-3.64; P = .001 and HR, 2.93; 95% CI, 1.31-6.55; P = .009, respectively). History of hypertension was associated with a favorable long-term outcome (adjusted HR, 0.51; 95% CI, 0.28-0.92; P = .02). Conclusions and Relevance: In this observational study of selected patients with CS and VT, catheter ablation was associated with reductions in defibrillator shocks and recurrent VT storm. Preablation LV dysfunction and myocardial inflammation were associated with adverse long-term prognosis. These data support the role of catheter ablation in conjunction with medical therapy in the management of CS-associated VT.


Assuntos
Antiarrítmicos/uso terapêutico , Cardiomiopatias/terapia , Ablação por Cateter , Morte Súbita Cardíaca/prevenção & controle , Sarcoidose/terapia , Taquicardia Ventricular/cirurgia , Adulto , Cardiomiopatias/complicações , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/fisiopatologia , Desfibriladores Implantáveis , Cardioversão Elétrica/estatística & dados numéricos , Feminino , Fluordesoxiglucose F18 , Coração/diagnóstico por imagem , Transplante de Coração/estatística & dados numéricos , Humanos , Inflamação/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Mortalidade , Análise Multivariada , Miocárdio , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos , Recidiva , Sarcoidose/complicações , Sarcoidose/diagnóstico por imagem , Sarcoidose/fisiopatologia , Volume Sistólico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/fisiopatologia , Resultado do Tratamento
17.
Ann Am Thorac Soc ; 18(12): 1935-1947, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34524933

RESUMO

Sarcoidosis is a multisystem disease of unknown cause with heterogeneous clinical manifestations and variable course. Spontaneous remissions occur in some patients, whereas others have progressive disease impacting survival, organ function, and quality of life. Four high-risk sarcoidosis phenotypes associated with chronic inflammation have recently been identified as high-priority areas for research. These include treatment-refractory pulmonary disease, cardiac sarcoidosis, neurosarcoidosis, and multiorgan sarcoidosis. Significant gaps currently exist in the understanding of these high-risk manifestations of sarcoidosis, including their natural history, diagnostic criteria, biomarkers, and the treatment strategy, such as the ideal agent, optimal dose, and treatment duration. The use of registries with well-phenotyped patients is a critical first step to study high-risk sarcoidosis manifestations systematically. We review the diagnostic and treatment approach to high-risk sarcoidosis manifestations. Appropriately identifying these disease subgroups will help enroll well-phenotyped patients in sarcoidosis registries and clinical trials, a necessary step to narrow existing gaps in understanding of this enigmatic disease.


Assuntos
Doenças do Sistema Nervoso Central , Sarcoidose , Humanos , Pulmão , Fenótipo , Qualidade de Vida , Sarcoidose/diagnóstico , Sarcoidose/terapia
18.
Circ Arrhythm Electrophysiol ; 14(9): e009966, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34546787

RESUMO

Background: There are few data on sex differences in suspected cardiac sarcoidosis. Methods: Consecutive patients with histologically proven sarcoidosis and suspected cardiac involvement were studied. We investigated sex differences in presenting features, cardiac involvement, and the long-term incidence of a primary composite end point of all-cause death or significant ventricular arrhythmia and secondary end points of all-cause death and significant ventricular arrhythmia. Results: Among 324 patients, 163 (50.3%) were female and 161 (49.7%) were male patients. Female patients had a greater prevalence of chest pain (37.4% versus 23.6%; P=0.010) and palpitations (39.3% versus 26.1%; P=0.016) than male patients but not dyspnea, presyncope, syncope, or arrhythmias at presentation. Female patients had a lower prevalence of late gadolinium enhancement on cardiovascular magnetic resonance imaging (20.2% versus 35.4%; P=0.003) and less often met criteria for a clinical diagnosis of cardiac sarcoidosis (Heart Rhythm Society consensus criteria, 22.7% versus 36.0%; P=0.012 and 2016 Japanese Circulation Society guideline criteria, 8.0% versus 19.3%; P=0.005), indicating lesser cardiac involvement. However, the long-term incidence of all-cause death or significant ventricular arrhythmia was not different between female and male patients (23.2% versus 23.2%; P=0.46). Among the secondary end points, the incidence of all-cause death was not different between female and male patients (20.7% versus 14.3%; P=0.51), while female patients had a lower incidence of significant ventricular arrhythmia compared with male patients (4.3% versus 13.0%; P=0.022). On multivariable analyses, sex was not associated with the primary end point (hazard ratio for female patients, 1.36 [95% CI, 0.77­2.43]; P=0.29). Conclusions: We observed distinct sex differences in patients with suspected cardiac sarcoidosis. A paradox was identified wherein female patients had a greater prevalence of chest pain and palpitations than male patients, but lesser cardiac involvement, and a similar long-term incidence of all-cause death or significant ventricular arrhythmia.


Assuntos
Cardiomiopatias/diagnóstico , Imagem Cinética por Ressonância Magnética/métodos , Miocárdio/patologia , Sarcoidose/diagnóstico , Cardiomiopatias/epidemiologia , Causas de Morte/tendências , Feminino , Seguimentos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Minnesota/epidemiologia , Estudos Retrospectivos , Sarcoidose/epidemiologia , Distribuição por Sexo , Fatores Sexuais
19.
Sci Rep ; 11(1): 19196, 2021 09 28.
Artigo em Inglês | MEDLINE | ID: mdl-34584108

RESUMO

The association between ventricular arrhythmias (VAs) and mortality in patients supported by continuous flow left ventricular assist devices (LVAD) remains controversial. To evaluate the association between pre-implantation, early (≤ 30 day) post-implantation VAs and mortality in bridge to transplant (BTT) and destination therapy (DT) LVAD patients, separately. The risk factors for post LVAD VAs were also investigated. In this observational cohort study, we included 341 patients who received a first time, continuous flow LVAD between January 1st 2010 and July 30th 2018. We used Kaplan-Meier curves and multivariable cox regression analyses to study the association between VAs and mortality in the BTT and DT populations. The mean age of the cohort was 58 ± 14 years, with 82% males, 53% had ischemic cardiomyopathy, and 45% were DT. The mean follow-up was 2.2 ± 2.1 years. In both BTT and DT cohorts, pre LVAD VAs were not associated with mortality after LVAD implantation (log-rank p = 0.95 and p = 0.089, respectively). In the BTT population, early post-LVAD VAs were not statistically associated with increased mortality (log rank p = 0.072). In the DT patients, early post LVAD VAs were associated with a 67% increase in the hazards rate of mortality on LVAD support (HR 1.67 [1.05-2.65], p = 0.029). The final model was adjusted for type of cardiomyopathy, INTERMACS profile, glomerular filtration rate, post LVAD atrial fibrillation, age and cerebrovascular events. Early post-LVAD VA is common after LVAD implantation and is an independent predictor of mortality in the DT LVAD population.


Assuntos
Arritmias Cardíacas/epidemiologia , Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Implantação de Prótese/estatística & dados numéricos , Adulto , Idoso , Arritmias Cardíacas/etiologia , Feminino , Seguimentos , Insuficiência Cardíaca/mortalidade , Transplante de Coração/métodos , Transplante de Coração/estatística & dados numéricos , Coração Auxiliar/estatística & dados numéricos , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA