Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
PLoS One ; 19(6): e0304612, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38870171

RESUMO

A similarity-driven multi-dimensional binning algorithm (SIMBA) reconstruction of free-running cardiac magnetic resonance imaging data was previously proposed. While very efficient and fast, the original SIMBA focused only on the reconstruction of a single motion-consistent cluster, discarding the remaining data acquired. However, the redundant data clustered by similarity may be exploited to further improve image quality. In this work, we propose a novel compressed sensing (CS) reconstruction that performs an effective regularization over the clustering dimension, thanks to the integration of inter-cluster motion compensation (XD-MC-SIMBA). This reconstruction was applied to free-running ferumoxytol-enhanced datasets from 24 patients with congenital heart disease, and compared to the original SIMBA, the same XD-MC-SIMBA reconstruction but without motion compensation (XD-SIMBA), and a 5D motion-resolved CS reconstruction using the free-running framework (FRF). The resulting images were compared in terms of lung-liver and blood-myocardium sharpness, blood-myocardium contrast ratio, and visible length and sharpness of the coronary arteries. Moreover, an automated image quality score (IQS) was assigned using a pretrained deep neural network. The lung-liver sharpness and blood-myocardium sharpness were significantly higher in XD-MC-SIMBA and FRF. Consistent with these findings, the IQS analysis revealed that image quality for XD-MC-SIMBA was improved in 18 of 24 cases, compared to SIMBA. We successfully tested the hypothesis that multiple motion-consistent SIMBA clusters can be exploited to improve the quality of ferumoxytol-enhanced cardiac MRI when inter-cluster motion-compensation is integrated as part of a CS reconstruction.


Assuntos
Algoritmos , Óxido Ferroso-Férrico , Cardiopatias Congênitas , Imageamento por Ressonância Magnética , Humanos , Cardiopatias Congênitas/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Masculino , Feminino , Processamento de Imagem Assistida por Computador/métodos , Coração/diagnóstico por imagem , Coração/fisiopatologia , Movimento (Física) , Adulto , Criança , Meios de Contraste , Adolescente , Adulto Jovem
2.
MAGMA ; 2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38743377

RESUMO

OBJECT: To enable high-quality physics-guided deep learning (PG-DL) reconstruction of large-scale 3D non-Cartesian coronary MRI by overcoming challenges of hardware limitations and limited training data availability. MATERIALS AND METHODS: While PG-DL has emerged as a powerful image reconstruction method, its application to large-scale 3D non-Cartesian MRI is hindered by hardware limitations and limited availability of training data. We combine several recent advances in deep learning and MRI reconstruction to tackle the former challenge, and we further propose a 2.5D reconstruction using 2D convolutional neural networks, which treat 3D volumes as batches of 2D images to train the network with a limited amount of training data. Both 3D and 2.5D variants of the PG-DL networks were compared to conventional methods for high-resolution 3D kooshball coronary MRI. RESULTS: Proposed PG-DL reconstructions of 3D non-Cartesian coronary MRI with 3D and 2.5D processing outperformed all conventional methods both quantitatively and qualitatively in terms of image assessment by an experienced cardiologist. The 2.5D variant further improved vessel sharpness compared to 3D processing, and scored higher in terms of qualitative image quality. DISCUSSION: PG-DL reconstruction of large-scale 3D non-Cartesian MRI without compromising image size or network complexity is achieved, and the proposed 2.5D processing enables high-quality reconstruction with limited training data.

3.
J Cardiovasc Magn Reson ; 26(1): 101037, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38499269

RESUMO

BACKGROUND: Free-running cardiac and respiratory motion-resolved whole-heart five-dimensional (5D) cardiovascular magnetic resonance (CMR) can reduce scan planning and provide a means of evaluating respiratory-driven changes in clinical parameters of interest. However, respiratory-resolved imaging can be limited by user-defined parameters which create trade-offs between residual artifact and motion blur. In this work, we develop and validate strategies for both correction of intra-bin and compensation of inter-bin respiratory motion to improve the quality of 5D CMR. METHODS: Each component of the reconstruction framework was systematically validated and compared to the previously established 5D approach using simulated free-running data (N = 50) and a cohort of 32 patients with congenital heart disease. The impact of intra-bin respiratory motion correction was evaluated in terms of image sharpness while inter-bin respiratory motion compensation was evaluated in terms of reconstruction error, compression of respiratory motion, and image sharpness. The full reconstruction framework (intra-acquisition correction and inter-acquisition compensation of respiratory motion [IIMC] 5D) was evaluated in terms of image sharpness and scoring of image quality by expert reviewers. RESULTS: Intra-bin motion correction provides significantly (p < 0.001) sharper images for both simulated and patient data. Inter-bin motion compensation results in significant (p < 0.001) lower reconstruction error, lower motion compression, and higher sharpness in both simulated (10/11) and patient (9/11) data. The combined framework resulted in significantly (p < 0.001) sharper IIMC 5D reconstructions (End-expiration (End-Exp): 0.45 ± 0.09, End-inspiration (End-Ins): 0.46 ± 0.10) relative to the previously established 5D implementation (End-Exp: 0.43 ± 0.08, End-Ins: 0.39 ± 0.09). Similarly, image scoring by three expert reviewers was significantly (p < 0.001) higher using IIMC 5D (End-Exp: 3.39 ± 0.44, End-Ins: 3.32 ± 0.45) relative to 5D images (End-Exp: 3.02 ± 0.54, End-Ins: 2.45 ± 0.52). CONCLUSION: The proposed IIMC reconstruction significantly improves the quality of 5D whole-heart MRI. This may be exploited for higher resolution or abbreviated scanning. Further investigation of the diagnostic impact of this framework and comparison to gold standards is needed to understand its full clinical utility, including exploration of respiratory-driven changes in physiological measurements of interest.


Assuntos
Artefatos , Cardiopatias Congênitas , Interpretação de Imagem Assistida por Computador , Valor Preditivo dos Testes , Humanos , Reprodutibilidade dos Testes , Feminino , Masculino , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/fisiopatologia , Adulto , Adulto Jovem , Imageamento por Ressonância Magnética , Adolescente , Mecânica Respiratória , Técnicas de Imagem de Sincronização Respiratória , Criança , Pessoa de Meia-Idade , Respiração , Imagem Cinética por Ressonância Magnética
4.
J Cardiovasc Magn Reson ; 26(1): 101006, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38309581

RESUMO

BACKGROUND: Four-dimensional (4D) flow magnetic resonance imaging (MRI) often relies on the injection of gadolinium- or iron-oxide-based contrast agents to improve vessel delineation. In this work, a novel technique is developed to acquire and reconstruct 4D flow data with excellent dynamic visualization of blood vessels but without the need for contrast injection. Synchronization of Neighboring Acquisitions by Physiological Signals (SyNAPS) uses pilot tone (PT) navigation to retrospectively synchronize the reconstruction of two free-running three-dimensional radial acquisitions, to create co-registered anatomy and flow images. METHODS: Thirteen volunteers and two Marfan syndrome patients were scanned without contrast agent using one free-running fast interrupted steady-state (FISS) sequence and one free-running phase-contrast MRI (PC-MRI) sequence. PT signals spanning the two sequences were recorded for retrospective respiratory motion correction and cardiac binning. The magnitude and phase images reconstructed, respectively, from FISS and PC-MRI, were synchronized to create SyNAPS 4D flow datasets. Conventional two-dimensional (2D) flow data were acquired for reference in ascending (AAo) and descending aorta (DAo). The blood-to-myocardium contrast ratio, dynamic vessel area, net volume, and peak flow were used to compare SyNAPS 4D flow with Native 4D flow (without FISS information) and 2D flow. A score of 0-4 was given to each dataset by two blinded experts regarding the feasibility of performing vessel delineation. RESULTS: Blood-to-myocardium contrast ratio for SyNAPS 4D flow magnitude images (1.5 ± 0.3) was significantly higher than for Native 4D flow (0.7 ± 0.1, p < 0.01) and was comparable to 2D flow (2.3 ± 0.9, p = 0.02). Image quality scores of SyNAPS 4D flow from the experts (M.P.: 1.9 ± 0.3, E.T.: 2.5 ± 0.5) were overall significantly higher than the scores from Native 4D flow (M.P.: 1.6 ± 0.6, p = 0.03, E.T.: 0.8 ± 0.4, p < 0.01) but still significantly lower than the scores from the reference 2D flow datasets (M.P.: 2.8 ± 0.4, p < 0.01, E.T.: 3.5 ± 0.7, p < 0.01). The Pearson correlation coefficient between the dynamic vessel area measured on SyNAPS 4D flow and that from 2D flow was 0.69 ± 0.24 for the AAo and 0.83 ± 0.10 for the DAo, whereas the Pearson correlation between Native 4D flow and 2D flow measurements was 0.12 ± 0.48 for the AAo and 0.08 ± 0.39 for the DAo. Linear correlations between SyNAPS 4D flow and 2D flow measurements of net volume (r2 = 0.83) and peak flow (r2 = 0.87) were larger than the correlations between Native 4D flow and 2D flow measurements of net volume (r2 = 0.79) and peak flow (r2 = 0.76). CONCLUSION: The feasibility and utility of SyNAPS were demonstrated for joint whole-heart anatomical and flow MRI without requiring electrocardiography gating, respiratory navigators, or contrast agents. Using SyNAPS, a high-contrast anatomical imaging sequence can be used to improve 4D flow measurements that often suffer from poor delineation of vessel boundaries in the absence of contrast agents.


Assuntos
Interpretação de Imagem Assistida por Computador , Síndrome de Marfan , Valor Preditivo dos Testes , Fluxo Sanguíneo Regional , Humanos , Velocidade do Fluxo Sanguíneo , Adulto , Masculino , Síndrome de Marfan/fisiopatologia , Feminino , Adulto Jovem , Estudos de Casos e Controles , Angiografia por Ressonância Magnética , Reprodutibilidade dos Testes , Estudos de Viabilidade , Hemodinâmica , Imagem de Perfusão/métodos , Meios de Contraste/administração & dosagem , Fatores de Tempo , Pessoa de Meia-Idade
5.
bioRxiv ; 2023 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-37425913

RESUMO

Functional magnetic resonance imaging (fMRI) is a methodological cornerstone of neuroscience. Most studies measure blood-oxygen-level-dependent (BOLD) signal using echo-planar imaging (EPI), Cartesian sampling, and image reconstruction with a one-to-one correspondence between the number of acquired volumes and reconstructed images. However, EPI schemes are subject to trade-offs between spatial and temporal resolutions. We overcome these limitations by measuring BOLD with a gradient recalled echo (GRE) with 3D radial-spiral phyllotaxis trajectory at a high sampling rate (28.24ms) on standard 3T field-strength. The framework enables the reconstruction of 3D signal time courses with whole-brain coverage at simultaneously higher spatial (1mm 3 ) and temporal (up to 250ms) resolutions, as compared to optimized EPI schemes. Additionally, artifacts are corrected before image reconstruction; the desired temporal resolution is chosen after scanning and without assumptions on the shape of the hemodynamic response. By showing activation in the calcarine sulcus of 20 participants performing an ON-OFF visual paradigm, we demonstrate the reliability of our method for cognitive neuroscience research.

6.
Magn Reson Med ; 90(3): 922-938, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37103471

RESUMO

PURPOSE: To develop a free-running 3D radial whole-heart multiecho gradient echo (ME-GRE) framework for cardiac- and respiratory-motion-resolved fat fraction (FF) quantification. METHODS: (NTE = 8) readouts optimized for water-fat separation and quantification were integrated within a continuous non-electrocardiogram-triggered free-breathing 3D radial GRE acquisition. Motion resolution was achieved with pilot tone (PT) navigation, and the extracted cardiac and respiratory signals were compared to those obtained with self-gating (SG). After extra-dimensional golden-angle radial sparse parallel-based image reconstruction, FF, R2 *, and B0 maps, as well as fat and water images were generated with a maximum-likelihood fitting algorithm. The framework was tested in a fat-water phantom and in 10 healthy volunteers at 1.5 T using NTE = 4 and NTE = 8 echoes. The separated images and maps were compared with a standard free-breathing electrocardiogram (ECG)-triggered acquisition. RESULTS: The method was validated in vivo, and physiological motion was resolved over all collected echoes. Across volunteers, PT provided respiratory and cardiac signals in agreement (r = 0.91 and r = 0.72) with SG of the first echo, and a higher correlation to the ECG (0.1% of missed triggers for PT vs. 5.9% for SG). The framework enabled pericardial fat imaging and quantification throughout the cardiac cycle, revealing a decrease in FF at end-systole by 11.4% ± 3.1% across volunteers (p < 0.0001). Motion-resolved end-diastolic 3D FF maps showed good correlation with ECG-triggered measurements (FF bias of -1.06%). A significant difference in free-running FF measured with NTE = 4 and NTE = 8 was found (p < 0.0001 in sub-cutaneous fat and p < 0.01 in pericardial fat). CONCLUSION: Free-running fat fraction mapping was validated at 1.5 T, enabling ME-GRE-based fat quantification with NTE = 8 echoes in 6:15 min.


Assuntos
Coração , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Coração/diagnóstico por imagem , Eletrocardiografia , Processamento de Imagem Assistida por Computador/métodos , Respiração , Imageamento Tridimensional/métodos
7.
Magn Reson Med ; 90(1): 117-132, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36877140

RESUMO

PURPOSE: To validate a respiratory motion correction method called focused navigation (fNAV) for free-running radial whole-heart 4D flow MRI. METHODS: Using fNAV, respiratory signals derived from radial readouts are converted into three orthogonal displacements, which are then used to correct respiratory motion in 4D flow datasets. Hundred 4D flow acquisitions were simulated with non-rigid respiratory motion and used for validation. The difference between generated and fNAV displacement coefficients was calculated. Vessel area and flow measurements from 4D flow reconstructions with (fNAV) and without (uncorrected) motion correction were compared to the motion-free ground-truth. In 25 patients, the same measurements were compared between fNAV 4D flow, 2D flow, navigator-gated Cartesian 4D flow, and uncorrected 4D flow datasets. RESULTS: For simulated data, the average difference between generated and fNAV displacement coefficients was 0.04 ± $$ \pm $$ 0.32 mm and 0.31 ± $$ \pm $$ 0.35 mm in the x and y directions, respectively. In the z direction, this difference was region-dependent (0.02 ± $$ \pm $$ 0.51 mm up to 5.85 ± $$ \pm $$ 3.41 mm). For all measurements (vessel area, net volume, and peak flow), the average difference from ground truth was higher for uncorrected 4D flow datasets (0.32 ± $$ \pm $$ 0.11 cm2 , 11.1 ± $$ \pm $$ 3.5 mL, and 22.3 ± $$ \pm $$ 6.0 mL/s) than for fNAV 4D flow datasets (0.10 ± $$ \pm $$ 0.03 cm2 , 2.6 ± $$ \pm $$ 0.7 mL, and 5.1 ± 0 $$ \pm 0 $$ .9 mL/s, p < 0.05). In vivo, average vessel area measurements were 4.92 ± $$ \pm $$ 2.95 cm2 , 5.06 ± $$ \pm $$ 2.64 cm2 , 4.87 ± $$ \pm $$ 2.57 cm2 , 4.87 ± $$ \pm $$ 2.69 cm2 , for 2D flow and fNAV, navigator-gated and uncorrected 4D flow datasets, respectively. In the ascending aorta, all 4D flow datasets except for the fNAV reconstruction had significantly different vessel area measurements from 2D flow. Overall, 2D flow datasets demonstrated the strongest correlation to fNAV 4D flow for both net volume (r2  = 0.92) and peak flow (r2  = 0.94), followed by navigator-gated 4D flow (r2  = 0.83 and r2  = 0.86, respectively), and uncorrected 4D flow (r2  = 0.69 and r2  = 0.86, respectively). CONCLUSION: fNAV corrected respiratory motion in vitro and in vivo, resulting in fNAV 4D flow measurements that are comparable to those derived from 2D flow and navigator-gated Cartesian 4D flow datasets, with improvements over those from uncorrected 4D flow.


Assuntos
Imageamento por Ressonância Magnética , Taxa Respiratória , Humanos , Imageamento por Ressonância Magnética/métodos , Movimento (Física) , Aorta , Imageamento Tridimensional/métodos
8.
J Cardiovasc Dev Dis ; 9(11)2022 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-36421934

RESUMO

The 2019 Global Burden of Disease (GBD) study estimated that there were approximately 24.2 million people affected worldwide by degenerative mitral regurgitation (MR), resulting in 34,200 deaths. After aortic stenosis, MR is the most prevalent VHD in Europe and the second-most common VHD to pose indications for surgery in western countries. Current ESC and AHA/ACC guidelines for the management of VHD emphasize the importance of an integrative approach for the assessment of MR severity, which is of paramount importance in dictating the timing for surgery. Transthoracic echocardiography (TTE) and transesophageal echocardiography (TEE) are the first-line imaging modalities; however, despite the technological advancement, sometimes, the final diagnosis on the degree of the disease may still be challenging. In the last 20 years, CMR has emerged as a robust technique in the assessment of patients with cardiac disease, and, recently, its role is gaining more and more importance in the field of VHD. In fact, CMR is the gold standard in the assessment of cardiac volumes, and it is possible to accurately evaluate the regurgitant volume. The purpose of this review is to outline the current state-of-the-art management of MR by using Cardiac Magnetic Resonance (CMR).

9.
J Cardiovasc Magn Reson ; 24(1): 39, 2022 06 27.
Artigo em Inglês | MEDLINE | ID: mdl-35754040

RESUMO

BACKGROUND: Coronary cardiovascular magnetic resonance angiography (CCMRA) of congenital heart disease (CHD) in pediatric patients requires accurate planning, adequate sequence parameter adjustments, lengthy scanning sessions, and significant involvement from highly trained personnel. Anesthesia and intubation are commonplace to minimize movements and control respiration in younger subjects. To address the above concerns and provide a single-click imaging solution, we applied our free-running framework for fully self-gated (SG) free-breathing 5D whole-heart CCMRA to CHD patients after ferumoxytol injection. We tested the hypothesis that spatial and motion resolution suffice to visualize coronary artery ostia in a cohort of CHD subjects, both for intubated and free-breathing acquisitions. METHODS: In 18 pediatric CHD patients, non-electrocardiogram (ECG) triggered 5D free-running gradient echo CCMRA with whole-heart 1 mm3 isotropic spatial resolution was performed in seven minutes on a 1.5T CMR scanner. Eleven patients were anesthetized and intubated, while seven were breathing freely without anesthesia. All patients were slowly injected with ferumoxytol (4 mg/kg) over 15 minutes. Cardiac and respiratory motion-resolved 5D images were reconstructed with a fully SG approach. To evaluate the performance of motion resolution, visibility of coronary artery origins was assessed. Intubated and free-breathing patient sub-groups were compared for image quality using coronary artery length and conspicuity as well as lung-liver interface sharpness. RESULTS: Data collection using the free-running framework was successful in all patients in less than 8 min; scan planning was very simple without the need for parameter adjustments, while no ECG lead placement and triggering was required. From the resulting SG 5D motion-resolved reconstructed images, coronary artery origins could be retrospectively extracted in 90% of the cases. These general findings applied to both intubated and free-breathing pediatric patients (no difference in terms of lung-liver interface sharpness), while image quality and coronary conspicuity between both cohorts was very similar. CONCLUSIONS: A simple-to-use push-button framework for 5D whole-heart CCMRA was successfully employed in pediatric CHD patients with ferumoxytol injection. This approach, working without any external gating and for a wide range of heart rates and body sizes provided excellent definition of cardiac anatomy for both intubated and free-breathing patients.


Assuntos
Cardiopatias Congênitas , Angiografia por Ressonância Magnética , Criança , Angiografia Coronária/métodos , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Óxido Ferroso-Férrico , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/patologia , Humanos , Imageamento Tridimensional/métodos , Pulmão , Angiografia por Ressonância Magnética/métodos , Valor Preditivo dos Testes , Respiração , Estudos Retrospectivos
10.
Sci Rep ; 12(1): 8682, 2022 05 23.
Artigo em Inglês | MEDLINE | ID: mdl-35606398

RESUMO

Accurate characterization of in utero human brain maturation is critical as it involves complex and interconnected structural and functional processes that may influence health later in life. Magnetic resonance imaging is a powerful tool to investigate equivocal neurological patterns during fetal development. However, the number of acquisitions of satisfactory quality available in this cohort of sensitive subjects remains scarce, thus hindering the validation of advanced image processing techniques. Numerical phantoms can mitigate these limitations by providing a controlled environment with a known ground truth. In this work, we present FaBiAN, an open-source Fetal Brain magnetic resonance Acquisition Numerical phantom that simulates clinical T2-weighted fast spin echo sequences of the fetal brain. This unique tool is based on a general, flexible and realistic setup that includes stochastic fetal movements, thus providing images of the fetal brain throughout maturation comparable to clinical acquisitions. We demonstrate its value to evaluate the robustness and optimize the accuracy of an algorithm for super-resolution fetal brain magnetic resonance imaging from simulated motion-corrupted 2D low-resolution series compared to a synthetic high-resolution reference volume. We also show that the images generated can complement clinical datasets to support data-intensive deep learning methods for fetal brain tissue segmentation.


Assuntos
Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Encéfalo/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética , Imagens de Fantasmas
11.
Magn Reson Med ; 87(2): 718-732, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34611923

RESUMO

PURPOSE: In this work, we integrated the pilot tone (PT) navigation system into a reconstruction framework for respiratory and cardiac motion-resolved 5D flow. We tested the hypotheses that PT would provide equivalent respiratory curves, cardiac triggers, and corresponding flow measurements to a previously established self-gating (SG) technique while being independent from changes to the acquisition parameters. METHODS: Fifteen volunteers and 9 patients were scanned with a free-running 5D flow sequence, with PT integrated. Respiratory curves and cardiac triggers from PT and SG were compared across all subjects. Flow measurements from 5D flow reconstructions using both PT and SG were compared to each other and to a reference electrocardiogram-gated and respiratory triggered 4D flow acquisition. Radial trajectories with variable readouts per interleave were also tested in 1 subject to compare cardiac trigger quality between PT and SG. RESULTS: The correlation between PT and SG respiratory curves were 0.95 ± 0.06 for volunteers and 0.95 ± 0.04 for patients. Heartbeat duration measurements in volunteers and patients showed a bias to electrocardiogram measurements of, respectively, 0.16 ± 64.94 ms and 0.01 ± 39.29 ms for PT versus electrocardiogram and of 0.24 ± 63.68 ms and 0.09 ± 32.79 ms for SG versus electrocardiogram. No significant differences were reported for the flow measurements between 5D flow PT and from 5D flow SG. A decrease in the cardiac triggering quality of SG was observed for increasing readouts per interleave, whereas PT quality remained constant. CONCLUSION: PT has been successfully integrated in 5D flow MRI and has shown equivalent results to the previously described 5D flow SG technique, while being completely acquisition-independent.


Assuntos
Coração , Imageamento por Ressonância Magnética , Eletrocardiografia , Coração/diagnóstico por imagem , Humanos , Movimento (Física) , Respiração , Taxa Respiratória
12.
Front Cardiovasc Med ; 8: 712383, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34660714

RESUMO

Background: T2 mapping is a magnetic resonance imaging technique that can be used to detect myocardial edema and inflammation. However, the focal nature of myocardial inflammation may render conventional 2D approaches suboptimal and make whole-heart isotropic 3D mapping desirable. While self-navigated 3D radial T2 mapping has been demonstrated to work well at a magnetic field strength of 3T, it results in too noisy maps at 1.5T. We therefore implemented a novel respiratory motion-resolved compressed-sensing reconstruction in order to improve the 3D T2 mapping precision and accuracy at 1.5T, and tested this in a heterogeneous patient cohort. Materials and Methods: Nine healthy volunteers and 25 consecutive patients with suspected acute non-ischemic myocardial injury (sarcoidosis, n = 19; systemic sclerosis, n = 2; acute graft rejection, n = 2, and myocarditis, n = 2) were included. The free-breathing T2 maps were acquired as three ECG-triggered T2-prepared 3D radial volumes. A respiratory motion-resolved reconstruction was followed by image registration of the respiratory states and pixel-wise T2 mapping. The resulting 3D maps were compared to routine 2D T2 maps. The T2 values of segments with and without late gadolinium enhancement (LGE) were compared in patients. Results: In the healthy volunteers, the myocardial T2 values obtained with the 2D and 3D techniques were similar (45.8 ± 1.8 vs. 46.8 ± 2.9 ms, respectively; P = 0.33). Conversely, in patients, T2 values did differ between 2D (46.7 ± 3.6 ms) and 3D techniques (50.1 ± 4.2 ms, P = 0.004). Moreover, with the 2D technique, T2 values of the LGE-positive segments were similar to those of the LGE-negative segments (T2LGE-= 46.2 ± 3.7 vs. T2LGE+ = 47.6 ± 4.1 ms; P = 0.49), whereas the 3D technique did show a significant difference (T2LGE- = 49.3 ± 6.7 vs. T2LGE+ = 52.6 ± 8.7 ms, P = 0.006). Conclusion: Respiratory motion-registered 3D radial imaging at 1.5T led to accurate isotropic 3D whole-heart T2 maps, both in the healthy volunteers and in a small patient cohort with suspected non-ischemic myocardial injury. Significantly higher T2 values were found in patients as compared to controls in 3D but not in 2D, suggestive of the technique's potential to increase the sensitivity of CMR at earlier stages of disease. Further study will be needed to demonstrate its accuracy.

14.
J Cardiovasc Magn Reson ; 23(1): 33, 2021 03 29.
Artigo em Inglês | MEDLINE | ID: mdl-33775246

RESUMO

BACKGROUND: Radial self-navigated (RSN) whole-heart coronary cardiovascular magnetic resonance angiography (CCMRA) is a free-breathing technique that estimates and corrects for respiratory motion. However, RSN has been limited to a 1D rigid correction which is often insufficient for patients with complex respiratory patterns. The goal of this work is therefore to improve the robustness and quality of 3D radial CCMRA by incorporating both 3D motion information and nonrigid intra-acquisition correction of the data into a framework called focused navigation (fNAV). METHODS: We applied fNAV to 500 data sets from a numerical simulation, 22 healthy subjects, and 549 cardiac patients. In each of these cohorts we compared fNAV to RSN and respiratory resolved extradimensional golden-angle radial sparse parallel (XD-GRASP) reconstructions of the same data. Reconstruction times for each method were recorded. Motion estimate accuracy was measured as the correlation between fNAV and ground truth for simulations, and fNAV and image registration for in vivo data. Percent vessel sharpness was measured in all simulated data sets and healthy subjects, and a subset of patients. Finally, subjective image quality analysis was performed by a blinded expert reviewer who chose the best image for each in vivo data set and scored on a Likert scale 0-4 in a subset of patients by two reviewers in consensus. RESULTS: The reconstruction time for fNAV images was significantly higher than RSN (6.1 ± 2.1 min vs 1.4 ± 0.3, min, p < 0.025) but significantly lower than XD-GRASP (25.6 ± 7.1, min, p < 0.025). Overall, there is high correlation between the fNAV and reference displacement estimates across all data sets (0.73 ± 0.29). For simulated data, healthy subjects, and patients, fNAV lead to significantly sharper coronary arteries than all other reconstruction methods (p < 0.01). Finally, in a blinded evaluation by an expert reviewer fNAV was chosen as the best image in 444 out of 571 data sets (78%; p < 0.001) and consensus grades of fNAV images (2.6 ± 0.6) were significantly higher (p < 0.05) than uncorrected (1.7 ± 0.7), RSN (1.9 ± 0.6), and XD-GRASP (1.8 ± 0.8). CONCLUSION: fNAV is a promising technique for improving the quality of RSN free-breathing 3D whole-heart CCMRA. This novel approach to respiratory self-navigation can derive 3D nonrigid motion estimations from an acquired 1D signal yielding statistically significant improvement in image sharpness relative to 1D translational correction as well as XD-GRASP reconstructions. Further study of the diagnostic impact of this technique is therefore warranted to evaluate its full clinical utility.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca , Angiografia Coronária , Doença das Coronárias/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador , Angiografia por Ressonância Magnética , Adulto , Idoso , Estudos de Casos e Controles , Simulação por Computador , Doença das Coronárias/fisiopatologia , Vasos Coronários/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Cardiovasculares , Movimento , Análise Numérica Assistida por Computador , Valor Preditivo dos Testes , Respiração , Adulto Jovem
15.
Magn Reson Med ; 86(1): 213-229, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33624348

RESUMO

PURPOSE: Whole-heart MRA techniques typically target predetermined motion states, address cardiac and respiratory dynamics independently, and require either complex planning or computationally demanding reconstructions. In contrast, we developed a fast data-driven reconstruction algorithm with minimal physiological assumptions and compatibility with ungated free-running sequences. THEORY AND METHODS: We propose a similarity-driven multi-dimensional binning algorithm (SIMBA) that clusters continuously acquired k-space data to find a motion-consistent subset for whole-heart MRA reconstruction. Free-running 3D radial data sets from 12 non-contrast-enhanced scans of healthy volunteers and six ferumoxytol-enhanced scans of pediatric cardiac patients were reconstructed with non-motion-suppressed regridding of all the acquired data ("All Data"), with SIMBA, and with a previously published free-running framework (FRF) that uses cardiac and respiratory self-gating and compressed sensing. Images were compared for blood-myocardium sharpness and contrast ratio, visibility of coronary artery ostia, and right coronary artery sharpness. RESULTS: Both the 20-second SIMBA reconstruction and FRF provided significantly higher blood-myocardium sharpness than All Data in both patients and volunteers (P < .05). The SIMBA reconstruction provided significantly sharper blood-myocardium interfaces than FRF in volunteers (P < .001) and higher blood-myocardium contrast ratio than All Data and FRF, both in volunteers and patients (P < .05). Significantly more ostia could be visualized with both SIMBA (31 of 36) and FRF (34 of 36) than with All Data (4 of 36) (P < .001). Inferior right coronary artery sharpness using SIMBA versus FRF was observed (volunteers: SIMBA 36.1 ± 8.1%, FRF 40.4 ± 8.9%; patients: SIMBA 35.9 ± 7.7%, FRF 40.3 ± 6.1%, P = not significant). CONCLUSION: The SIMBA technique enabled a fast, data-driven reconstruction of free-running whole-heart MRA with image quality superior to All Data and similar to the more time-consuming FRF reconstruction.


Assuntos
Imageamento Tridimensional , Angiografia por Ressonância Magnética , Algoritmos , Criança , Vasos Coronários/diagnóstico por imagem , Humanos , Movimento (Física)
16.
J Magn Reson Imaging ; 53(2): 540-551, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32815242

RESUMO

BACKGROUND: Phase contrast MRI in the great vessels is a potential clinical tool for managing fetal pathologies. One challenge is the uncontrollable fetal motion, potentially corrupting flow quantifications. PURPOSE: To demonstrate improvements in fetal blood flow quantification in great vessels using retrospectively motion-corrected golden-angle radial phase contrast MRI relative to Cartesian phase contrast MRI. STUDY TYPE: Method comparison. PHANTOM/SUBJECTS: Computer simulation. Seventeen pregnant volunteers. FIELD STRENGTH/SEQUENCE: 1.5T and 3T. Cartesian and golden-angle radial phase contrast MRI. ASSESSMENT: Through computer simulations, radial (with and without retrospective motion correction) and Cartesian phase contrast MRI were compared using flow deviations. in vivo Cartesian and radial phase contrast MRI measurements and reconstruction qualities were compared in pregnancies. Cartesian data were reconstructed into gated reconstructions (CINEs) after cardiac gating with metric optimized gating (MOG). For radial data, real-time reconstructions were performed for motion correction and MOG followed by CINE reconstructions. STATISTICAL TESTS: Wilcoxon signed-rank test. Linear regression. Bland-Altman plots. Student's t-test. RESULTS: Simulations showed significant improvements (P < 0.05) in flow accuracy and reconstruction quality with motion correction ([mean/peak] flow errors with ±5 mm motion corruption: Cartesian [35 ± 1/115 ± 7] mL/s, motion uncorrected radial [25 ± 1/75 ± 2] mL/s and motion-corrected radial [1.0 ± 0.5/-5 ± 1] mL/s). in vivo Cartesian reconstructions without motion correction had lower quality than the motion-corrected radial reconstructions (P < 0.05). Across all fetal mean flow measurements, the bias [limits of agreement] between the two measurements were -0.2 [-76, 75] mL/min/kg, while the linear regression coefficients were (Mradial = 0.81 × MCartesian + 29.8 [mL/min/kg], r2 = 0.67). The corresponding measures for the peak fetal flows were -23 [-214, 167] mL/min/kg and (Pradial = 0.95 × PCartesian -1.2 [mL/min/kg], r2 = 0.80). Cartesian reconstructions of low quality showed significantly higher estimated mean and peak (P < 0.05) flows than the corresponding radial reconstructions. DATA CONCLUSION: Simulations showed that radial phase contrast MRI with motion compensation improved flow accuracy. For fetal measurements, motion-corrected radial reconstructions showed better image quality than, and different flow values from, Cartesian reconstructions. Level of Evidence 1. Technical Efficacy Stage 1. J. MAGN. RESON. IMAGING 2021;53:540-551.


Assuntos
Interpretação de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Simulação por Computador , Feminino , Humanos , Movimento (Física) , Gravidez , Reprodutibilidade dos Testes , Estudos Retrospectivos
17.
Magn Reson Med ; 84(3): 1470-1485, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32144824

RESUMO

PURPOSE: To implement, optimize, and characterize lipid-insensitive binomial off-resonant RF excitation (LIBRE) pulses for fat-suppressed fully self-gated free-running 5D cardiac MRI. METHODS: Bloch equation simulations were used to optimize LIBRE parameter settings in non-interrupted bSSFP prior to in vitro validation. Thus, optimized LIBRE pulses were subsequently applied to free-running coronary MRA in 20 human adult subjects, where resulting images were quantitatively compared to those obtained with non-fat-suppressing excitation (SP), conventional 1-2-1 water excitation (WE), and a previously published interrupted free-running (IFR) sequence. SAR and scan times were recorded. Respiratory-and-cardiac-motion-resolved images were reconstructed with XD-GRASP, and contrast ratios, coronary artery detection rate, vessel length, and vessel sharpness were computed. RESULTS: The numerically optimized LIBRE parameters were successfully validated in vitro. In vivo, LIBRE had the lowest SAR and a scan time that was similar to that of WE yet 18% shorter than that of IFR. LIBRE improved blood-fat contrast when compared to SP, WE, and IFR, vessel detection relative to SP and IFR, and vessel sharpness when compared to WE and IFR (for example, for the left main and anterior descending coronary artery, 51.5% ± 10.2% [LIBRE] versus 42.1% ± 6.8% [IFR]). Vessel length measurements remained unchanged for all investigated methods. CONCLUSION: LIBRE enabled fully self-gated non-interrupted free-running 5D bSSFP imaging of the heart at 1.5T with suppressed fat signal. Measures of image quality, vessel conspicuity, and scan time compared favorably to those obtained with the more conventional non-interrupted WE and the previously published IFR, while SAR reduction offers added flexibility.


Assuntos
Coração , Água , Adulto , Angiografia Coronária , Vasos Coronários/diagnóstico por imagem , Humanos , Imageamento Tridimensional , Lipídeos , Angiografia por Ressonância Magnética , Imageamento por Ressonância Magnética
18.
Radiol Cardiothorac Imaging ; 2(6): e200219, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33385164

RESUMO

PURPOSE: To implement, validate, and apply a self-gated free-running whole-heart five-dimensional (5D) flow MRI framework to evaluate respiration-driven effects on three-dimensional (3D) hemodynamics in a clinical setting. MATERIALS AND METHODS: In this prospective study, a free-running five-dimensional (5D) flow sequence was implemented with 3D radial sampling, self-gating, and a compressed-sensing reconstruction. The 5D flow was evaluated in a pulsatile phantom and adult participants with aortic and/or valvular disease who were enrolled between May and August 2019. Conventional twofold-accelerated four-dimensional (4D) flow of the thoracic aorta with navigator gating was performed as a reference comparison. Continuous parameters were evaluated for parameter normality and were compared between conventional 4D flow and 5D flow using a signed-rank or two-tailed paired t test. Differences between respiratory states were evaluated using a repeated-measure analysis of variance or a nonparametric Friedman test. RESULTS: A total of 20 adult participants (mean age, 49 years ± 17 [standard deviation]; 18 men and two women) were included. In vitro 5D flow results showed excellent agreement with conventional 4D flow-derived values (peak and net flow, <7% difference over all quantified planes). Whole-heart 5D flow data were collected in all participants in 7.65 minutes ± 0.35 (acceleration rate = 36.0-76.9) versus 9.88 minutes ± 3.17 for conventional aortic 4D flow. In vivo, 5D flow demonstrated moderate agreement with conventional 4D flow but demonstrated overestimation in net flow and peak velocity (up to 26% and 12%, respectively) in the ascending aorta and underestimation (<12%) in the arch and descending aorta. Respiratory-resolved analyses of caval veins showed significantly increased net and peak flow in the inferior vena cava in end inspiration compared with end expiration, and the opposite trend was shown in the superior vena cava. CONCLUSION: A free-running 5D flow MRI framework consistently captured cardiac and respiratory motion-resolved 3D hemodynamics in less than 8 minutes. Supplemental material is available for this article. © RSNA, 2020.

19.
Magn Reson Med ; 83(1): 45-55, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31452244

RESUMO

PURPOSE: To implement, optimize, and test fast interrupted steady-state (FISS) for natively fat-suppressed free-running 5D whole-heart MRI at 1.5 tesla (T) and 3T. METHODS: FISS was implemented for fully self-gated free-running cardiac- and respiratory-motion-resolved radial imaging of the heart at 1.5T and 3T. Numerical simulations and phantom scans were performed to compare fat suppression characteristics and to determine parameter ranges (number of readouts [NR] per FISS module and TR) for effective fat suppression. Subsequently, free-running FISS data were collected in 10 healthy volunteers and images were reconstructed with compressed sensing. All acquisitions were compared with a continuous balanced steady-state free precession version of the same sequence, and both fat suppression and scan times were analyzed. RESULTS: Simulations demonstrate a variable width and location of suppression bands in FISS that were dependent on TR and NR. For a fat suppression bandwidth of 100 Hz and NR ≤ 8, simulations demonstrated that a TR between 2.2 ms and 3.0 ms is required at 1.5T, whereas a range of 3.0 ms to 3.5 ms applies at 3T. Fat signal increases with NR. These findings were corroborated in phantom experiments. In volunteers, fat SNR was significantly decreased using FISS compared with balanced steady-state free precession (P < 0.05) at both field strengths. After protocol optimization, high-resolution (1.1 mm3 ) 5D whole-heart free-running FISS can be performed with effective fat suppression in under 8 min at 1.5T and 3T at a modest scan time increase compared to balanced steady-state free precession. CONCLUSION: An optimal FISS parameter range was determined enabling natively fat-suppressed 5D whole-heart free-running MRI with a single continuous scan at 1.5T and 3T, demonstrating potential for cardiac imaging and noncontrast angiography.


Assuntos
Radicais Livres , Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética , Técnicas de Imagem de Sincronização Respiratória , Algoritmos , Simulação por Computador , Angiografia Coronária , Eletrocardiografia , Voluntários Saudáveis , Humanos , Processamento de Imagem Assistida por Computador , Modelos Teóricos , Movimento (Física) , Distribuição Normal , Imagens de Fantasmas , Razão Sinal-Ruído
20.
Top Magn Reson Imaging ; 28(5): 235-244, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31592990

RESUMO

Magnetic resonance imaging (MRI) is an appealing technology for fetal cardiovascular assessment. It can be used to visualize fetal cardiac and vascular anatomy, to quantify fetal blood flow, and to quantify fetal blood oxygen saturation and hematocrit. However, there are practical limitations to the use of conventional MRI for fetal cardiovascular assessment, including the small size and high heart rate of the human fetus, the lack of conventional cardiac gating methods to synchronize data acquisition, and the potential corruption of MRI data due to maternal respiration and unpredictable fetal movements. In this review, we discuss recent technical advances in accelerated imaging, image reconstruction, cardiac gating, and motion compensation that have enabled dynamic MRI of the fetal heart.


Assuntos
Coração Fetal/diagnóstico por imagem , Cardiopatias Congênitas/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Diagnóstico Pré-Natal/métodos , Feminino , Coração Fetal/embriologia , Humanos , Movimento (Física)
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA