Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Talanta ; 273: 125911, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38508129

RESUMO

Lateral flow immunoassays (LFIAs) are widely used to determine carbendazim (CBZ) residues in food products due to their advantages of low cost, ease and rapid use, on-site detection capability. However, conventional LFIAs have low detection sensitivity. Although improvements have been made to increase the sensitivity, it is not sufficient. Here, a hamper pad, polyvinyl alcohol coated on a nitrocellulose membrane, was integrated to enhance the sensitivity of LFIA for CBZ detection. The hamper pad was inserted between the conjugated and nitrocellulose pads to delay the flow rate, thereby increasing the possibility of the antibody and target analyte binding. This platform exhibited a fourfold sensitivity increase in CBZ detection compared with the conventional LFIA, and its limit of detection was 1.6 ng/mL. In addition, a single-step operation was successfully applied to detect CBZ in rice (white rice, brown rice, sticky rice, and paddy) and soybean samples, with acceptable recoveries of 93.6%-120.0%. This novel device was compared to the standard high-performance liquid chromatography method, which shows high accuracy with a Kappa coefficient of 0.91. Therefore, improved sensitivity with a rapid, simple, and inexpensive device could facilitate the detection of CBZ residues in agricultural products for on-field screening and improved user-friendliness.


Assuntos
Benzimidazóis , Nanopartículas Metálicas , Colódio , Imunoensaio/métodos , Carbamatos , Nanopartículas Metálicas/química
2.
Sens Actuators B Chem ; 389: 133898, 2023 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-37151731

RESUMO

Equipment-free colorimetric-based lateral flow immunoassay (LFIA) is the most convenient and popular tool for various applications, including diagnostic tools requiring high sensitivity for the detection of pathogens. Thus, improvements and developments of LFIA are constantly being reported. Herein, we enriched the sensitivity of LFIA using the gold enhancement principle, emphasizing needlessly complicated apparatus, only one step for the strip test operation, and typical time incubation (15 min) process. Self-enhanced LFIA was then executed for subsequent flows by overlapping the additionally enhanced pad composed of gold ions and reducing agent on the conjugate pad and the sample pad. Self-enhanced LFIA was performed to detect SARS-CoV-2 antigens in saliva. The obtained result depicted that the achieved sensitivity was up to tenfold compared with that of conventional LFIA by visual measurements. The detection limits of self-enhanced LFIA detecting nucleocapsid protein antigens in the saliva sample was 0.50 and 0.10 ng/mL employed by naked eye detection and calibration curve-based calculation, respectively. When the proposed device was applied to 207 human saliva samples, the diagnostic performance presented a 96.10 % sensitivity and 99.23 % specificity. This self-enhanced LFIA could be implemented in large-scale production and demonstrates higher sensitivity with effortless use, which meets the requirements for point-of-care testing and on-field mass screening.

3.
PLoS One ; 18(4): e0284305, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37043507

RESUMO

Detection of anti-Strongyloides IgG in urine by enzyme-linked immunosorbent assay (ELISA) for diagnosis of strongyloidiasis reportedly has comparable performance to conventional serum assays. Initial comparisons of urine assays using commercial ELISA kits designated for serology have shown its diagnostic potential but sub-optimal accuracy. In the present study, we optimized urine ELISA protocols based on different antigen types and evaluated their accuracies in determining the epidemiology of strongyloidiasis in Northeast Thailand. Paired urine and fecal samples of 966 individuals from the study community were collected for three consecutive days and tested for strongyloidiasis. We compared three ELISA protocols using different antigens including crude S. stercoralis antigen (Ss-ELISA), crude S. ratti antigen (Sr-ELISA) and recombinant NIE antigen (NIE-ELISA) and fecal examination by agar plate-culture (APCT) technique and formalin-ethyl acetate concentration technique (FECT). The optimized ELISA protocols using three different antigen sources yielded significantly higher prevalence rates of strongyloidiasis (58.9-65.1%) than those by fecal examination methods (19.7%). The prevalence of strongyloidiasis determined by ELISA protocols significantly increased with age (p value < 0.0001) and males had higher prevalence than females (p value < 0.0001). Diagnostic agreements between ELISA protocols were moderate (κ = 0.461-0.586) and the agreement between each ELISA protocol and fecal examinations were slight (κ = 0.139-0.210). The results obtained by urine ELISA protocols using three different antigens showed comparable diagnostic performances, provided further supports for the utility of urine as an alternative clinical specimen for diagnosis of strongyloidiasis.


Assuntos
Parasitos , Strongyloides stercoralis , Estrongiloidíase , Masculino , Animais , Feminino , Humanos , Estrongiloidíase/diagnóstico , Estrongiloidíase/epidemiologia , Tailândia/epidemiologia , Anticorpos Anti-Helmínticos , Ensaio de Imunoadsorção Enzimática/métodos , Antígenos de Helmintos , Fezes , Proteínas Recombinantes , Imunoglobulina G , Sensibilidade e Especificidade
4.
J Clin Microbiol ; 60(1): e0145421, 2022 01 19.
Artigo em Inglês | MEDLINE | ID: mdl-34705534

RESUMO

Detection of IgG in urine is an efficient method comparable to that in serum for diagnosis of strongyloidiasis, but the effects of daily variation in urine dilution on diagnostic accuracy are not clearly known. This study evaluated the effects of urine concentration on the detection of parasite-specific IgG by urine enzyme-linked immunosorbent assay (ELISA), particularly in individuals with borderline results or false-negative diagnosis. Optimal concentration conditions were established by comparing Strongyloides-specific IgG antibody levels between unconcentrated and concentrated urine in participants with different infection intensities, namely, healthy control (HC), low-negative (LN), high-negative (HN), and low-positive (LP) groups. The optimal condition was selected and validated in a field trial study. The final urine concentration protocol required centrifugation at 4,000 × g at 4°C for 10 mins using the Amicon concentrator tube. This protocol was validated in groups of participants with various diagnoses according to urine ELISA and fecal examination (n = 148). The concentrated-urine ELISA increased the proportion of positive results in the LN group by 68.2% and by 100% in the HN group. Significantly elevated IgG antibody levels were seen in the LP group. In the group that was false negative by urine ELISA but positive by fecal examination (n = 28), concentrated-urine ELISA yielded 100% positive results. Overall, the frequency estimates of Strongyloides stercoralis were 23.6% by fecal culture, 27% by standard urine ELISA, and 90.5% by concentrated-urine ELISA. The concentration of urine samples prior to analysis by ELISA improved the sensitivity for diagnosis and is potentially useful in the diagnosis of strongyloidiasis in immunocompromised individuals or in low-prevalence areas.


Assuntos
Strongyloides stercoralis , Estrongiloidíase , Animais , Anticorpos Anti-Helmínticos , Ensaio de Imunoadsorção Enzimática/métodos , Humanos , Imunoglobulina G , Sensibilidade e Especificidade , Estrongiloidíase/diagnóstico
5.
Am J Trop Med Hyg ; 105(3): 688-691, 2021 07 08.
Artigo em Inglês | MEDLINE | ID: mdl-34237022

RESUMO

Strongyloides stercoralis affects more than half a billion people worldwide, and hyperinfection in immunocompromised patients can be fatal. Elimination of this neglected tropical disease requires field-applicable diagnostic tools. We conducted a laboratory evaluation of a lateral flow rapid dipstick test (SsRapid™) using sera samples from a Strongyloides-endemic area in northeast Thailand. Group 1 was S. stercoralis-positive and larvae- and/or antibody-positive (according to the IgG ELISA) (N = 100). Group 2 had negative fecal examination and IgG ELISA results (N = 25). Group 3 had other parasitic infections and negative IgG ELISA results (N = 25). The results showed good diagnostic sensitivity (82%) and excellent specificity (96%). Suggested improvements in the SsRapid™ test include increased diagnostic sensitivity and conversion to the more robust cassette format. Field studies should be performed as well.


Assuntos
Anticorpos Anti-Helmínticos/imunologia , Imunoglobulina G/imunologia , Strongyloides stercoralis/imunologia , Estrongiloidíase/diagnóstico , Animais , Anticorpos Anti-Helmínticos/sangue , Fezes/parasitologia , Proteínas de Helminto , Humanos , Proteínas Recombinantes , Sensibilidade e Especificidade , Testes Sorológicos , Estrongiloidíase/sangue , Tailândia
6.
Acta Trop ; 218: 105896, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33753029

RESUMO

Recent work has found urine analysis to be as sensitive as serology for diagnosis of strongyloidiasis. Here, we examined the daily variation of Strongyloides-specific IgG in urine by qualitative and quantitative ELISA and its effects on diagnostic accuracy and reliability. In the first part of the study, matched urine and fecal samples were collected from project participants in northeast Thailand for three consecutive days. Urine samples were analyzed for Strongyloides-specific IgG by ELISA using Strongyloides ratti as the antigen source. Performance of urine ELISA was compared with parasitological diagnosis by agar plate culture technique (APCT) and formalin-ethyl acetate concentration technique (FECT). In the second part of the study, urine IgG levels were compared daily for thirty consecutive days. The prevalence of Strongyloides infection, as measured by urine ELISA for three consecutive days, was significantly higher than that found using parasitological methods (63.1% vs. 22%). There was slight daily variation in prevalence estimates according to urine ELISA while there were significant variations according to parasitological examination methods over three consecutive days. For the 3-day experiment, urine ELISA had 83-86% diagnostic sensitivity when compared with the fecal examination method or with a composite standard (combined results from fecal examination methods (APCT or FECT) and/or urine ELISA). The levels of parasite-specific IgG in urine were stable throughout both the 3-day and the 30-day studies. In conclusion, diagnosis of strongyloidiasis by urine ELISA is more sensitive than by fecal methods, with minimal daily variation for qualitative and quantitative diagnosis. Urine ELISA has potential for clinical diagnosis and population screening of strongyloidiasis.


Assuntos
Anticorpos Anti-Helmínticos/urina , Fezes/parasitologia , Estrongiloidíase/diagnóstico , Urina/parasitologia , Adulto , Animais , Reações Cruzadas , Ensaio de Imunoadsorção Enzimática , Feminino , Formaldeído , Humanos , Imunoglobulina G/urina , Masculino , Pessoa de Meia-Idade , Prevalência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Manejo de Espécimes/métodos , Strongyloides ratti , Strongyloides stercoralis , Tailândia/epidemiologia
7.
PLoS Negl Trop Dis ; 13(6): e0006943, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-31220075

RESUMO

BACKGROUND: Strongyloides stercoralis is a neglected soil-transmitted helminth that occurs worldwide, though it is particularly endemic in tropical and subtropical areas. It can cause long-lasting and potentially fatal infections due to its ability to replicate within its host. S. stercoralis causes gastrointestinal and dermatological morbidity. The objective of this study was to assess the S. stercoralis infection risk and, using geostatistical models, to predict its geographical distribution in Cambodia. METHODOLOGY / PRINCIPAL FINDINGS: A nation-wide, community-based parasitological survey was conducted among the Cambodian population, aged 6 years and older. S. stercoralis was diagnosed using a serological diagnostic test that detects IgG antibodies in urine. Data on demography, hygiene and knowledge about helminth infection were collected. S. stercoralis prevalence among 7,246 participants with a complete data record was 30.5%, ranging from 10.9% to 48.2% across provinces. The parasite was ubiquitous in Cambodia; only five south-eastern provinces had prevalence rates below 20%. Infection risk increased with age for both men and women, although girls under the age of 13 and women aged 50 years and over had lower odds of infection than their male counterparts. Open defecation was associated with higher odds of infection, while having some knowledge of the health problems caused by worms was a protective factor. Infection risk was positively associated with nighttime maximum temperature, minimum rainfall, and distance to water; it was negatively associated with land occupied by rice fields. CONCLUSIONS / SIGNIFICANCE: S. stercoralis infection is rampant in Cambodia. Control programs delivering ivermectin are needed to manage the parasite. However, the high cost of this drug in Cambodia currently precludes the implementation of control initiatives. Donations, subsidies or affordable generics are needed so that S. stercoralis, which infects almost a third of the Cambodian population, can be addressed through an adequate control program.


Assuntos
Anticorpos Anti-Helmínticos/urina , Strongyloides stercoralis/imunologia , Estrongiloidíase/epidemiologia , Topografia Médica , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Animais , Camboja/epidemiologia , Criança , Feminino , Humanos , Imunoglobulina G/urina , Masculino , Pessoa de Meia-Idade , Medição de Risco , Estudos Soroepidemiológicos , Inquéritos e Questionários , Adulto Jovem
8.
Am J Trop Med Hyg ; 100(1): 127-129, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30398144

RESUMO

To evaluate the accuracy and reliability of urine assay for the diagnosis of strongyloidiasis, three different immunoassays were used to assess the diagnostic accuracy of anti-Strongyloides immunoglobulin G (IgG) in urine and compared with those in serum samples. Analyses by InBios enzyme-linked immunosorbent assay (ELISA) kit (recombinant NIE antigen), SciMedx ELISA kit (Strongyloides stercoralis antigen), and our in-house ELISA (Strongyloides ratti antigen) yielded comparable diagnostic performances between urine and serum assays. Levels of Strongyloides-specific IgG in urine significantly correlated with those in serum. Tests for diagnostic agreement between urine and serum IgG assays showed substantial to fair agreement (κ = 0.207-0.615). The observed quantitative and qualitative concordance between urine and serum assays in strongyloidiasis suggests that urine has similar diagnostic value to that for serum. Because of the ease and noninvasiveness of clinical sample collection, urine assay has a high potential for the initial diagnosis and mass screening of strongyloidiasis.


Assuntos
Anticorpos Anti-Helmínticos/sangue , Anticorpos Anti-Helmínticos/urina , Ensaio de Imunoadsorção Enzimática/normas , Imunoglobulina G/sangue , Imunoglobulina G/urina , Strongyloides stercoralis/isolamento & purificação , Estrongiloidíase/diagnóstico , Idoso , Animais , Estudos Transversais , Ensaio de Imunoadsorção Enzimática/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Strongyloides stercoralis/imunologia , Estrongiloidíase/sangue , Estrongiloidíase/urina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA