Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 471
Filtrar
1.
Clin Nucl Med ; 46(4): 310-322, 2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-33534256

RESUMO

PURPOSE: To compare the agreement between whole-body (WB) magnetic resonance (MR) imaging, 18F-FDG PET/CT, and skeletal survey (SS) in patients with multiple myeloma (MM) for diagnosis, initial staging, response evaluation, and early detection of complications. METHODS: This is a retrospective cohort study including MM patients who were diagnosed, treated, and followed in 2 institutions. These patients were studied with SS, WB-MR, and/or 18F-FDG PET/CT. We studied bone lesions by anatomical locations and analyzed the concordance between SS and a tomographic technique (WB-MR or 18F-FDG PET/CT) and between both tomographic techniques (WB-MR and PET/CT). RESULTS: Forty-four MM patients with a mean age of 62.6 years (range, 38-85 years) were included from January 2012 to February 2016. Whole-body MR and 18F-FDG PET/CT found more lesions than SS in every location except in the skull. Concordance between WB-MR and 18F-FDG PET/CT was either good or excellent in most of the locations and in plasmacytoma studies. However, WB-MR was better than 18F-FDG PET/CT in the study of complications (medullar compression and vascular necrosis). CONCLUSIONS: Our results suggest the study of MM patients should include WB-MR and/or 18F-FDG PET/CT, whereas SS is only useful for the skull. Whole-body MR and 18F-FDG PET/CT are complementary techniques, because both of them show good concordance in almost every location. It is still necessary to individualize the indication of each technique according to patient characteristics.


Assuntos
Fluordesoxiglucose F18 , Imageamento por Ressonância Magnética , Mieloma Múltiplo/patologia , Mieloma Múltiplo/terapia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Esqueleto/diagnóstico por imagem , Imagem Corporal Total , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Mieloma Múltiplo/diagnóstico por imagem , Estudos Retrospectivos , Resultado do Tratamento
2.
J Neurooncol ; 152(2): 325-332, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33502678

RESUMO

INTRODUCTION: This study aimed to test the diagnostic significance of FET-PET imaging combined with machine learning for the differentiation between multiple sclerosis (MS) and glioma II°-IV°. METHODS: Our database was screened for patients in whom FET-PET imaging was performed for the diagnostic workup of newly diagnosed lesions evident on MRI and suggestive of glioma. Among those, we identified patients with histologically confirmed glioma II°-IV°, and those who later turned out to have MS. For each group, tumor-to-brain ratio (TBR) derived features of FET were determined. A support vector machine (SVM) based machine learning algorithm was constructed to enhance classification ability, and Receiver Operating Characteristic (ROC) analysis with area under the curve (AUC) metric served to ascertain model performance. RESULTS: A total of 41 patients met selection criteria, including seven patients with MS and 34 patients with glioma. TBR values were significantly higher in the glioma group (TBRmax glioma vs. MS: p = 0.002; TBRmean glioma vs. MS: p = 0.014). In a subgroup analysis, TBR values significantly differentiated between MS and glioblastoma (TBRmax glioblastoma vs. MS: p = 0.0003, TBRmean glioblastoma vs. MS: p = 0.0003) and between MS and oligodendroglioma (ODG) (TBRmax ODG vs. MS: p = 0.003; TBRmean ODG vs. MS: p = 0.01). The ability to differentiate between MS and glioma II°-IV° increased from 0.79 using standard TBR analysis to 0.94 using a SVM based machine learning algorithm. CONCLUSIONS: FET-PET imaging may help differentiate MS from glioma II°-IV° and SVM based machine learning approaches can enhance classification performance.


Assuntos
Neoplasias Encefálicas/diagnóstico por imagem , Glioma/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Aprendizado de Máquina , Esclerose Múltipla/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos , Tirosina/análogos & derivados
3.
Clin Nucl Med ; 46(4): e181-e187, 2021 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-33323744

RESUMO

PURPOSE: The clinical introduction of a radioactive and fluorescent hybrid tracer allowed for preoperative lymphatic mapping and intraoperative real-time fluorescence tracing of the sentinel lymph node (SLN) by a single injection. The aim of this feasibility study is to evaluate the first-in-human use of the hybrid tracer by combining indocyanine green (ICG) and radiocolloid based on Nanotop compound (99mTc Nanotop) for SLN biopsy (SLNB) in breast cancer patients. METHODS: The day before surgery, ICG-99mTc Nanotop was injected periareolarly in breast cancer patients scheduled for SLNB. Planar lymphoscintigraphic (PL) and SPECT/CT images were then acquired. An intraoperative optonuclear probe was used to detect SLN gamma and fluorescent signals. The harvested SLNs were examined by hematoxylin-eosin staining, and patients were clinically evaluated 1 month after surgery. RESULTS: Twenty-one consecutive patients were enrolled. The PL and SPECT/CT techniques identified at least 1 SLN in all patients for a preoperative sentinel detection rate of 100%. SPECT/CT revealed 3 additional lymph nodes in the same nodal basin, which had not been visualized on conventional PL (κ = 0.747; P < 0.005). All 30 preoperative SLNs were localized and excised up to 16 hours after injection. The counts measured via gamma tracing showed a very strong correlation with those measured via near-infrared fluorescent tracing (P < 0.005, r = 0.964). No adverse reactions were observed. CONCLUSIONS: The SLNB technique used with the ICG-99mTc Nanotop tracer resulted to be feasible, reliable, and safe. This hybrid compound allowed us to obtain excellent performance in terms of both preoperative lymphatic mapping and intraoperative SLN detection in breast cancer patients.


Assuntos
Neoplasias da Mama/patologia , Verde de Indocianina/química , Biópsia de Linfonodo Sentinela/métodos , Tecnécio/química , Adulto , Idoso , Neoplasias da Mama/diagnóstico por imagem , Estudos de Viabilidade , Feminino , Humanos , Linfadenopatia , Metástase Linfática , Pessoa de Meia-Idade , Traçadores Radioativos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único
4.
Biomed Pharmacother ; 133: 110936, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33254016

RESUMO

Lapachol (LAP) is a natural compound with various biological properties, including anticancer activity. However, its clinical application is limited due to the low aqueous solubility and potential adverse side effects. Nanoemulsions are drug delivery systems that can assist in the administration of hydrophobic drugs, increasing their bioavailability and protecting from degradation. Thus, this study aimed to prepare a LAP-loaded nanoemulsion (NE-LAP), and evaluate its antitumor activity. For this purpose, the nanoemulsion was prepared using a hot homogenization method and characterized morphologically by cryogenic transmission electron microscopy (cryo-TEM). Mean diameter, polydispersity index, and zeta potential was evaluated by DLS, encapsulation efficiency was measured by HPLC. Moreover, the short-term storage stability, the drug release and hemolysis in vitro was determined. Additionally, pharmacokinetic, toxicology and toxicity properties of99mTc-NE-LAP were evaluated in a breast cancer (4T1) tumor model. The cryo-TEM showed spherical globules, and the physicochemical characterization of NE-LAP showed a homogeneous stable nanoemulsion with a mean diameter of ∼170 nm, zeta potential of around -20 mV, and encapsulation greater than 85 %. In vitro studies validated that encapsulation did not impair the cytotoxicity activity of LAP. The nanoemulsion was successfully radiolabeled and 99mTc-NE-LAP showed prolonged blood circulation and tumor affinity was confirmed by tumor-to-muscle ratio. Moreover, NE-LAP showed higher antitumor activity than the free drug and the treatment did not result in any signs of toxicity. Therefore, these findings suggest that NE-LAP can be considered an effective strategy for cancer treatment.


Assuntos
Antineoplásicos Fitogênicos/farmacologia , Neoplasias da Mama/tratamento farmacológico , Nanopartículas , Naftoquinonas/farmacologia , Animais , Antineoplásicos Fitogênicos/química , Antineoplásicos Fitogênicos/farmacocinética , Neoplasias da Mama/patologia , Linhagem Celular Tumoral , Composição de Medicamentos , Liberação Controlada de Fármacos , Estabilidade de Medicamentos , Emulsões , Feminino , Humanos , Camundongos Endogâmicos BALB C , Naftoquinonas/química , Naftoquinonas/farmacocinética , Carga Tumoral
5.
Clin Nucl Med ; 46(2): 171-172, 2021 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-33208617

RESUMO

ABSTRACT: A 60-year-old woman with primary hyperparathyroidism with previous nonconclusive imaging studies was referred for 18F-fluorocholine (18F-FCH) PET/CT as part of the preoperative diagnostic imaging workup to localize the adenoma before minimally invasive surgery. 18F-FCH PET/CT with dual time point was performed, acquiring immediately and 60 minutes after 18F-FCH administration. The early images demonstrated possible hyperfunctioning parathyroid tissue in the mediastinum, located in the right upper paratracheal space (region 2R), with an incidental iatrogenic subclavian venous air bubble embolism presenting as high uptake in the early images that disappeared in the late images. No symptomatology was reported during the examination.


Assuntos
Colina/análogos & derivados , Embolia Aérea/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Veias/diagnóstico por imagem , Feminino , Humanos , Pessoa de Meia-Idade
6.
Biomed Pharmacother ; 132: 110865, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33254427

RESUMO

INTRODUCTION: Selective Internal Radiation Therapy (SIRT) is used for the treatment of hepatic tumors. The aim of this retrospective study was to compare two dosimetric approaches based on 99mTc-MAA SPECT/CT and 90Y PET/CT, using Simplicit90Y™ versus the supplier suggested method of activity calculation. MATERIAL AND METHODS: A total of 19 patients underwent 21 SIRT after baseline angiography and 99mTc-MAA SPECT/CT, followed by 90Y PET/CT. Overlap between 99mTc-MAA and 90Y-microspheres was quantified with different thresholds isocontours. The perfused volume and tumor absorbed dose were estimated using Simplicit90Y™ based on SPECT/CT and PET/CT, then compared with the supplier suggested method. These data were related to overall survival to evaluate their prognostic impact. RESULTS: The overlap between PET/CT and SPECT/CT was dependent on thresholds, decreasing with an increasing threshold. The overlap between the 99mTc-MAA and 90Y-microspheres biodistributions versus the tumor distribution on morphological imaging was suboptimal, in particular for small tumor volume. The tumor absorbed dose estimated after 90Y PET/CT was not different from tumor absorbed dose estimated after SPECT/CT. The Perfused lobe absorbed dose was significantly lower while the volume of the perfused lobe was significantly higher when estimated by Simplicit90Y™ compared to the supplier suggested conventional approach. A statistical parameter based on overlap between tumor and 90Y-microspheres distribution as well as tumoral dosimetry was significantly related to the overall survival. CONCLUSION: Post-treatment imaging remains paramount to estimate the irradiation dosimetry, due to an imperfect overlap. The perfused volume could be estimated from functional imaging, given its impact on dosimetry. Finally, survival seems related to tumoral overlap and dosimetry.


Assuntos
Carcinoma Hepatocelular/radioterapia , Neoplasias Hepáticas/radioterapia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/métodos , Idoso , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/metabolismo , Feminino , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/metabolismo , Masculino , Pessoa de Meia-Idade , Radioterapia Assistida por Computador/métodos , Estudos Retrospectivos , Radioisótopos de Ítrio/metabolismo
7.
Clin Nucl Med ; 45(12): 943-947, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32910057

RESUMO

AIM: The aim of this study was to evaluate if integrating whole-body PET/CT with CT colonography (PET/CTC) improves the preoperative diagnosis of obstructive colorectal cancer (CRC). METHODS: We prospectively included 47 consecutive patients (18 women and 29 men; mean age, 71 ± 14 years) suspected of having CRC by optical colonoscopy, which was not completed due to obstructive masses. To perform PET/CTC, a small caliber Foley catheter was inserted to distend the colon with CO2 insufflations. Polyps measuring 10 mm or larger were considered as high risk of malignancy. All findings were histologically confirmed. RESULTS: Colorectal cancer was localized in the sigmoid (n = 21), rectum (n = 7), rectosigmoid junction (n = 5), ascending (n = 7), descending (n = 5), and transverse (n = 2) colon. All tumors showed FDG uptake (mean ± SD SUVmax, 20.02 ± 9.9) including one synchronic tumor (SUVmax, 10.46). Forty-seven polyps were histologically confirmed as smaller than 10 mm (n = 35) and 10 mm or larger (n = 12). All 12 polyps 10 mm or larger showed FDG uptake (SUVmax range, 3.08-19.5), but only one smaller than 10 mm could be identified by PET. Pathological lymph nodes were diagnosed in 17/47 cases after surgical removal with a sensitivity and specificity for CTC and PET/CTC of 71% and 97% and 59% and 100%, respectively. Liver metastases were confirmed in 9 patients and in 4/9 along with lung metastases (n = 2) or implants (n = 2), showing a sensitivity and specificity for CTC of 89% and 100% and both 100% for PET/CTC. CONCLUSIONS: PET/CTC is a reliable technique for staging CRC and diagnosing synchronous tumors. In this series, PET/CTC was not able to identify small polyps but showed potential use for ruling out 10 mm or larger polyps at high risk of malignancy.


Assuntos
Colonografia Tomográfica Computadorizada , Colonoscopia , Neoplasias Colorretais/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias Colorretais/patologia , Neoplasias Colorretais/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Período Pré-Operatório , Estudos Prospectivos , Sensibilidade e Especificidade
8.
Clin Nucl Med ; 45(11): 854-859, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32796237

RESUMO

Coronavirus disease (COVID-19) outbreak has profoundly changed the organization of hospital activities. We present our experience of reorganization of a nuclear medicine service settled in Northern Italy during the pandemic period of March and April 2020 characterized a government-mandated lockdown. Our service remained open during the whole period, performing approximately 80% of the routine practice, while maintaining it COVID-free despite the geographical context characterized by a high risk of infection. Reorganization involved all aspects of a nuclear medicine department, following local, national, and international guidelines for prioritizing patients, telephone and physical triages, deployment of appropriate personal protective equipment, social distancing, and logistic changes for scheduling examinations and disinfection procedures. All staff remained COVID-19-negative despite the unintentional admission of 4 patients who later turned out to be positive for the severe acute respiratory syndrome coronavirus 2. These adopted measures would serve as the basis for safe nuclear medicine services in the post-lockdown phase.


Assuntos
Infecções por Coronavirus/epidemiologia , Departamentos Hospitalares/organização & administração , Medicina Nuclear , Pandemias , Pneumonia Viral/epidemiologia , COVID-19 , Humanos , Itália/epidemiologia
9.
Clin Nucl Med ; 45(10): 771-777, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32701805

RESUMO

We review recent technological advances and new clinical indications for sentinel node (SN) and radioguided surgery in order to delineate future tendencies of interventional nuclear medicine in this field. A literature research was performed in PubMed to select relevant articles to be used as key references for analysis of the current approaches and tendencies in SN and radioguided surgery, as well as the evolving contribution of nuclear medicine intervention techniques to the various clinical applications. For classic indications such as melanoma and breast cancer, the incorporation of the SN approach based on the combined use of existing and new preoperative and intraoperative technologies in high-risk patient categories is becoming an emerging area of clinical indication. For SN biopsy staging in other malignancies with more complex lymphatic drainage, the incorporation of sophisticated tools is most helpful. The consecutive use of PET/CT and the SN procedure is increasing as a potential combined approach for the management of specific areas such as the axilla and the pelvis in patients at high risk of regional dissemination. Also, for the management of locoregional metastasis and oligometastatic disease, interventional nuclear medicine techniques are becoming valuable alternatives. The extended experience with SN biopsy is leading to technological advances facilitating the incorporation of this procedure to stage other malignancies with complex lymphatic drainage. New nuclear medicine-based approaches, incorporating SPECT/CT and PET/CT to guide resection of SNs and occult metastases, have recently been gaining ground.


Assuntos
Biópsia Guiada por Imagem/métodos , Medicina Nuclear , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Linfonodo Sentinela/diagnóstico por imagem , Linfonodo Sentinela/cirurgia , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Humanos , Linfonodo Sentinela/patologia
10.
Clin Nucl Med ; 45(8): 652-653, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32520507

RESUMO

We present an asymptomatic 70-year-old man referred for an F-FDG PET/CT for initial staging of a Hodgkin lymphoma. F-FDG PET/CT showed bilateral cervical lymphadenopathy (stage II). Incidentally, the CT demonstrated bilateral ground-glass opacities with low-grade F-FDG activity. CT findings were suspicious for COVID-19 pneumonitis. The COVID-19 reverse transcriptase polymerase chain reaction (RT-PCR) examination result was negative. Given the high clinical suspicion for COVID-19, the patient was isolated and repeat RT-PCR was positive at 72 hours. RT-PCR may be falsely negative in early COVID-19 disease, even with positive CT findings.


Assuntos
Betacoronavirus , Infecções por Coronavirus/diagnóstico por imagem , Doença de Hodgkin/complicações , Pneumonia Viral/diagnóstico por imagem , Idoso , COVID-19 , Teste para COVID-19 , Técnicas de Laboratório Clínico , Infecções por Coronavirus/complicações , Infecções por Coronavirus/diagnóstico , Fluordesoxiglucose F18 , Humanos , Masculino , Pandemias , Pneumonia Viral/complicações , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , SARS-CoV-2
11.
J Clin Med ; 9(6)2020 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-32498217

RESUMO

We compared the detection rate (DR) for sentinel lymph nodes (SLN), the number of SLNs and the subjects with additional SLNs of single-photon emission computed tomography (SPECT/CT) and planar lymphoscintigraphy (PL) in patients with melanoma. Furthermore, we evaluated the impact of SPECT/CT on surgical plans. Articles containing head-to-head comparisons between SPECT/CT and PL were searched in Pubmed/MEDLINE and Scopus. The literature search was updated until December 31st, 2019. DR was calculated on a per patient-based analysis; the studies were pooled by their odds ratios (ORs) with a random effects model to assess the significance of difference (p < 0.05). The number of additional SLNs (calculated as the relative risk) and pooled proportion of patients with additional SLNs were investigated. The pooled ratio of surgical procedures influenced by the SPECT/CT findings was calculated. Seventeen studies with 1438 patients were eligible for the calculation of DR of SPECT/CT and PL. The average DR was 98.28% (95% confidence interval (95% CI): 97.94-99.19%) for the SPECT/CT and 95.53% (95% CI: 92.55-97.77%) for the PL; OR of 2.31 (95% CI: 1.66-4.18, p < 0.001) in favor of the SPECT/CT. There was a relative risk of a higher number of SLNs (1.13) for the SPECT/CT and 17.87% of patients with additional SLNs were detected by SPECT/CT. The average impact of SPECT/CT on surgery resulted in 37.43% of cases. This meta-analysis favored SPECT/CT over PL for the identification of SLNs in patients with melanoma due to a higher DR, reproducibility, number of SLNs depicted, proportion of patients with additional SLNs and the impact on the surgical plan. However, PL remains a good option due to the high values of the DR for SLNs.

12.
Clin Nucl Med ; 45(8): 611-617, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32558716

RESUMO

At the moment, international guidelines for rectal cancer suggest to consider F-FDG PET/CT scan in a few conditions: (1) at disease presentation in case of suspected or proven metastatic synchronous adenocarcinoma with potentially curable M1 disease; (2) in the recurrence workup for serial carcinoembryonic antigen level elevation; (3) in the recurrence workup with metachronous metastases documented by CT, MRI, or biopsy; (4) in case of strong contraindication to IV contrast agent administration; and (5) to evaluate an equivocal finding on a contrast-enhanced CT or MRI. PET/CT is not indicated in the follow-up or surveillance of rectal cancer. On the other hand, an attentive evaluation of the literature shows that PET/CT may also be used in some circumstances with significant levels of diagnostic accuracy. This review article aims to emphasize differences between current international guidelines and scientific literature in the role of PET/CT in rectal cancer.


Assuntos
Adenocarcinoma/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/normas , Guias de Prática Clínica como Assunto , Neoplasias Retais/diagnóstico por imagem , Adenocarcinoma/patologia , Fluordesoxiglucose F18 , Humanos , Compostos Radiofarmacêuticos , Neoplasias Retais/patologia
13.
Clin Nucl Med ; 45(7): 525-530, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32433179

RESUMO

International colon cancer guidelines suggest F-FDG PET/CT in a few circumstances: (1) at disease presentation in case of suspected or proven metastatic synchronous adenocarcinoma; (2) in the workup of recurrent colon cancer with metachronous metastases documented by CT, MRI, or biopsy and in case of serial CEA elevation with negative colonoscopy and negative CT; and (3) in case of contraindication to iodine- and gadolinium-based contrast agents. However, review of the literature has shown that PET/CT can also be used in other scenarios with significant levels of diagnostic advantage. This review aims to emphasize differences between guidelines and scientific literature for the use of PET/CT in colon cancer.


Assuntos
Neoplasias do Colo/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Guias de Prática Clínica como Assunto , Adenocarcinoma/diagnóstico por imagem , Adenocarcinoma/patologia , Idoso , Biópsia , Neoplasias do Colo/patologia , Meios de Contraste , Feminino , Fluordesoxiglucose F18 , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Metástase Neoplásica
14.
Eur J Surg Oncol ; 46(6): 967-975, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32098735

RESUMO

BACKGROUND: The management of papillary thyroid carcinoma (PTC) is changed after introduction of sentinel lymph node biopsy (SNB) technique for nodal staging. Some debate still surrounds the accuracy of this procedure in terms of wide heterogeneity of sentinel lymph node detection and false-negative findings. AIM: to identify the key issues which make it difficult the usefulness of SNB in PTC. METHODS: A comprehensive computer literature search of meta-analyses published in PubMed/MEDLINE and Cochrane library database until June 30, 2019 was conducted. We used a search algorithm based on this combination of terms: (i) "thyroid neoplasm" or "thyroid cancer" or "thyroid carcinoma" or "thyroid malignancy" or "meta-analysis" or "systematic review") AND (ii) "sentinel lymph node biopsy". RESULTS: Comparing 4 written meta-analyses published in the literature, the diagnostic performance of SNB technique in PTC has been summarized. Relatively high false-negative rates (FNR) were reported for each SNB methods: vital-dye (VD: 12.7%; 7%; 0-38%), 99mTc-nanocolloid planar lymphoscintigraphy with the use of intraoperative hand-held gamma probes (LS: 11.3%; 16%; 0-40%), combined LS with VD (LS+VD: 0%; 0-17%), LS with the additional contribution of preoperative SPECT/CT (7-8%). CONCLUSION: Evidence-based data about the diagnostic performance of SNB in PTC are increasing. The nuclear medicine community should reach a consensus on the operational definition of the SLN to better guide the surgeon in identifying the lymph nodes most likely contain metastatic cells. Standardization of SLN identification, removal and analysis are required.


Assuntos
Biópsia de Linfonodo Sentinela/métodos , Câncer Papilífero da Tireoide/secundário , Neoplasias da Glândula Tireoide/patologia , Reações Falso-Negativas , Humanos , Metástase Linfática , Câncer Papilífero da Tireoide/diagnóstico
15.
Biomed Pharmacother ; 130: 110596, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34321170

RESUMO

BACKGROUND: Sacubitril/valsartan, the first agent to be approved in a new class of drugs called angiotensin receptor neprilysin inhibitors (ARNIs), has been shown to reduce cardiovascular mortality and morbidity compared to enalapril in outpatient subjects with chronic heart failure (HF) and reduced left ventricular ejection fraction (HFrEF). However, there is little real-world evidence about the efficacy of ARNIs in elderly hypertensive patients with HFrEF and comorbidities. METHODS: In this prospective open-label study, 108 subjects, 54 of them (mean age 78.6 ±â€¯8.2 years, 75.0 % male), with HFrEF (29.8 ±â€¯4.3 %) and New York Heart Association (NYHA) class II-III symptoms were assigned to receive ARNIs twice daily, according to the recommended dosage of 24/26, 49/51, 97/103 mg. Patients were gender- and age-matched with a control arm of patients with HFrEF receiving the optimal standard therapy for HF. The clinic blood pressure (BP), N-terminal pro-B-type natriuretic peptide (NT-proBNP), estimated glomerular filtration rate (eGFR), blood glucose and glycated hemoglobin (HbA1c), uric acid (UA), left ventricular ejection fraction (LVEF) and NYHA class were evaluated at a mean follow-up of 12 months. During the follow-up, the clinical outcomes, including mortality and re-hospitalization for HF, were collected. RESULTS: NYHA class significantly improved in the ARNI arm compared to the control (24.9 vs. 6.4 %, shifting from class III to II, and 55.4 vs. 25.2 %, from class II to I, p < 0.05 for all). A significant improvement in LVEF and eGFR levels was found in the ARNI arm compared to controls (42.4 vs. 34.2 %, 73.8 vs. 61.2 mL/min, respectively; p < 0.001 for all). NT-proBNP, clinic systolic and diastolic BP, blood glucose, HbA1c and UA values were reduced in both treatment arms, but they were lower in the ARNI arm compared controls (3107 vs. 4552 pg/mL, 112.2 vs. 120.4 and 68.8 vs. 75.6 mmHg, 108.4 vs. 112.6 mg/dL, 5.4 vs. 5.9 % and 5.9 vs. 6.4 mg/dL, respectively, p < 0.05). Mortality and re-hospitalization for HF was lower in the ARNI arm than controls (20.1 vs. 33.6 % and 27.7 vs. 46.3 % respectively; p < 0.05 for all). Gender differences were not found in either arm. No patients refused to continue the study, and no side effects to the ARNI treatment were observed. CONCLUSIONS: In elderly patients with HFrEF and comorbidities, ARNI treatment seems effective and safe. The improvement in LVEF and cardiac remodeling, BP, eGFR, serum glucose, UA and HbA1c could be the mechanisms by which ARNIs play their beneficial role on clinical outcomes. However, these results need to be confirmed in studies involving a greater number of subjects, and with a longer follow-up.


Assuntos
Aminobutiratos/uso terapêutico , Compostos de Bifenilo/uso terapêutico , Insuficiência Cardíaca/tratamento farmacológico , Insuficiência Cardíaca/fisiopatologia , Volume Sistólico/efeitos dos fármacos , Valsartana/uso terapêutico , Idoso , Aminobutiratos/administração & dosagem , Aminobutiratos/efeitos adversos , Compostos de Bifenilo/administração & dosagem , Compostos de Bifenilo/efeitos adversos , Doença Crônica , Estudos Clínicos como Assunto , Combinação de Medicamentos , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/etiologia , Humanos , Hipertensão/complicações , Masculino , Readmissão do Paciente , Prognóstico , Índice de Gravidade de Doença , Resultado do Tratamento , Valsartana/administração & dosagem , Valsartana/efeitos adversos , Disfunção Ventricular Esquerda/tratamento farmacológico
16.
J Radiol Prot ; 40(1): 243-252, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31499482

RESUMO

PURPOSE: Recently new mobile systems for dispensing positron emitters have been produced, designed to guarantee dispensing cycles in an aseptic environment. The aim of the present work was to assess the advantage of one of these systems in radiation protection of operators in clinical settings. METHODS: Recently, in our centre the new self-dispensing system named KARL100 by Tema Sinergie was adopted for 18F-FDG radiopharmaceuticals. The system is associated with an automatic Rad-inject infuser. The system that was previously used was a fixed isolator NMC DSI (Tema Sinergie), equipped with a µDDS-An activity fractioning system, together with a pneumatic post for the syringe delivery. The dosimetric evaluations on both systems were carried out through environmental measurements with an ionisation chamber and with the use of personal dosimeters. RESULTS: The operations of preparation and administration of 18F-FDG dose to the patient, with the use of Karl100 + RadInject, involve exposures much lower than those obtained by the fixed isolator. The average body exposure of the technician was reduced by 31%, and for the physician by 77%. On the extremities, the equivalent dose to the hands of the technician was reduced by 78%, and for the physician by 96%. Also the additional dosimeters worn by the technician confirmed the estimated environmental assessments. CONCLUSIONS: The exposures of the working personnel were significantly reduced with the introduction of the new KARL100 system.


Assuntos
Fluordesoxiglucose F18/administração & dosagem , Exposição Ocupacional/prevenção & controle , Proteção Radiológica/métodos , Radiometria/instrumentação , Compostos Radiofarmacêuticos/administração & dosagem , Humanos , Doses de Radiação
17.
Clin Nucl Med ; 45(1): 38-43, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31714278

RESUMO

PURPOSE: The outcome of locally advanced adenocarcinoma of the esophagogastric junction (AEG) treated with preoperative chemoradiotherapy is heterogeneous, and favorable response to this treatment is a key factor in the patient's prognosis. The aim of this study was to evaluate F-FDG PET/CT in assessing metabolic response in patients with AEG. MATERIALS AND METHODS: This prospective study evaluated all consecutive patients with potentially operable locally advanced AEG who were candidates for neoadjuvant chemoradiotherapy. PET/CT and contrast-enhanced thoracoabdominal CT were performed at baseline and 2 weeks after completion of chemoradiotherapy for response evaluation. The response rate was assessed using Response Evaluation Criteria in Solid Tumors criteria for contrast-enhanced thoracoabdominal CT and Positron Emission Tomography Response Criteria in Solid Tumors criteria for PET/CT. The regression rate was assessed using a 5-grade histopathology scoring system of the surgically resected tumor. Metastatic lesions were confirmed by histopathology examination or imaging and clinical follow-up at 6 months. RESULTS: A total of 40 cases were finally included in the study. Distant metastases were found in the baseline PET/CT in 6 of 40 cases (retroperitoneal [2] or mediastinal/hiliar [1] lymph nodes and liver [2] or bone [1] metastases) and were therefore excluded from surgery. Pathologic response correlated with the ΛSUVmax threshold of ≤45% (P = 0.033). CT response correlated well with both the baseline SUVmax (P = 0.039) and the ΛSUVmax (P = 0.001). Five-year survival curves for AEG correlated with the ΛSUVmax using a threshold of ≤45% for both progression-free and overall survival. CONCLUSIONS: F-FDG PET/CT is useful for diagnosing nonsuspected metastasis before neoadjuvancy in potentially operable AEG. The ΛSUV correlates with pathologic response and is a long-term independent prognostic factor of survival.


Assuntos
Adenocarcinoma/diagnóstico por imagem , Adenocarcinoma/terapia , Quimiorradioterapia , Neoplasias Esofágicas/diagnóstico por imagem , Neoplasias Esofágicas/terapia , Junção Esofagogástrica/patologia , Fluordesoxiglucose F18 , Terapia Neoadjuvante , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Adenocarcinoma/patologia , Neoplasias Esofágicas/patologia , Junção Esofagogástrica/diagnóstico por imagem , Junção Esofagogástrica/efeitos dos fármacos , Junção Esofagogástrica/efeitos da radiação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos
18.
Pharmaceuticals (Basel) ; 12(4)2019 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-31775273

RESUMO

Conventional chemotherapy regimens have limitations due to serious adverse effects. Targeted drug delivery systems to reduce systemic toxicity are a powerful drug development platform. Encapsulation of antitumor drug(s) in thermosensitive nanocarriers is an emerging approach with a promise to improve uptake and increase therapeutic efficacy, as they can be activated by hyperthermia selectively at the tumor site. In this review, we focus on thermosensitive nanosystems associated with hyperthermia for the treatment of cancer, in preclinical and clinical use.

19.
Biomed Pharmacother ; 120: 109539, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31627089

RESUMO

BACKGROUND: Most antihypertensive drugs used in monotherapy or in combination therapy reduce the left ventricular mass index (LVMI). However, little is known about the effects on LVMI of a triple fixed-dose combination (TFC) therapy, containing in a single pill an angiotensin-converting enzyme inhibitor (ACEI), a diuretic and a calcium channel blocker (CCB). METHODS: In this prospective open-label study, 92 patients with essential hypertension were randomized to treatment with a TFC of perindopril/indapamide/amlodipine at different doses or a triple free combination therapy (FCT) including ACEI/diuretic/CCB. Office blood pressure (BP) measurement, 24 h-ambulatory BP monitoring and echocardiography were performed at baseline and during a 14-month follow-up. The BP variability (BPV) over 24 h was calculated as ± standard deviation of the daytime systolic BP. Differences between office and monitored BP and LVMI were evaluated by ANOVA for repeated measures. RESULTS: A significant BP-lowering effect was observed for both treatments. At follow-up, BPV was reduced in both the treatment groups vs. the baseline (14.0±1.5 vs. 17.0±1.8 and 16.2±2.1 vs. 17.6±2.3, respectively), but it was lower in the TFC vs. the FCT group (14.0±1.5 vs. 16.1±2.2, P < 0.05). LVMI was lower in both the treatment groups, but the change was greater for TFC vs. FCT (-8.3±4.9% vs. -2.0 ±2.1%, P < 0.0001). Left ventricular hypertrophy (LVH) regression was greater in the TFC vs. the FCT group (43.5% vs. 30.4%, P < 0.05). CONCLUSIONS: Independently of BP values achieved, the antihypertensive TFC therapy was more effective than FCT in LVMI reduction and LVH regression, possibly related to drugs' intrinsic properties and to BPV modulation.


Assuntos
Anlodipino/uso terapêutico , Hipertensão/complicações , Hipertensão/tratamento farmacológico , Hipertrofia Ventricular Esquerda/complicações , Hipertrofia Ventricular Esquerda/tratamento farmacológico , Indapamida/uso terapêutico , Pacientes Ambulatoriais , Perindopril/uso terapêutico , Pressão Sanguínea/efeitos dos fármacos , Monitorização Ambulatorial da Pressão Arterial , Combinação de Medicamentos , Feminino , Seguimentos , Humanos , Hipertensão/fisiopatologia , Hipertrofia Ventricular Esquerda/fisiopatologia , Masculino , Pessoa de Meia-Idade , Sístole/efeitos dos fármacos , Fatores de Tempo
20.
Biomed Pharmacother ; 118: 109323, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31400669

RESUMO

Long circulating pH-sensitive liposomes have been shown to effectively deliver doxorubicin (DOX) to tumors and reduce its toxic effects. Folic acid receptors are upregulated in a wide variety of solid, epithelial tumors, including breast cancer. In order to improve liposomal endocytosis and antitumor activity, folic acid has been added to nanoparticles surfaces to exploit overexpression of folate receptors in tumor cells. The purpose of this study was to evaluate the antitumor activity in vitro and in vivo of long circulating pH-sensitive folate-coated DOX-loaded liposomes (SpHL-DOX-Fol) in a 4T1 breast cancer model system in vitro and in vivo. Biodistribution studies were performed and in vivo electrocardiographic parameters were evaluated. A higher tumor uptake for radiolabeled SpHL-Fol (99mTc-SpHL-Fol) 4 h after intravenous administration was observed in comparision with non-folate-coated liposomes (99mTc-SpHL). Antitumor activity showed that SpHL-DOX-Fol treatment led to a 68% growth arrest and drastically reduce pulmonary metastasis foci. Additionally, eletrocardiographic parameters analysis revealed no dispersion in the QT and QTc interval was observed in liposomal treated mice. In summary, this novel multifunctional nanoplatform deomonstrated higher tumor uptake and antitumor activity. SpHL-DOX-Fol represents a drug delivery platform to improve DOX tumor delivery and reduce dose-limiting toxicity.


Assuntos
Neoplasias da Mama/tratamento farmacológico , Doxorrubicina/uso terapêutico , Ácido Fólico/química , Animais , Antineoplásicos/farmacologia , Antineoplásicos/uso terapêutico , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Neoplasias da Mama/ultraestrutura , Linhagem Celular Tumoral , Sobrevivência Celular/efeitos dos fármacos , Modelos Animais de Doenças , Doxorrubicina/sangue , Doxorrubicina/farmacologia , Feminino , Concentração de Íons de Hidrogênio , Lipossomos , Camundongos Endogâmicos BALB C , Metástase Neoplásica , Distribuição Tecidual/efeitos dos fármacos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA