Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Eur J Clin Invest ; 53(4): e13935, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36504276

RESUMO

BACKGROUND: Although cardiac resynchronization therapy (CRT) is beneficial in most heart failure patients, up to 40% do not respond to CRT. It has been suggested that multipoint left ventricle pacing (MPP) would increase the response rate. AIM: To assess the CRT response rate at 6 months in patients implanted with a CRT device with the MPP feature activated early after the implant. METHODS: This was a multicentre, prospective, open-label and non-randomized study. The primary endpoint was response to biventricular pacing defined as >15% relative reduction in left ventricular end-systolic volume (LVESV) comparing echocardiography measurements performed at baseline and 6 months by a core laboratory. Among secondary endpoints the combined endpoint of mortality or all-cause hospitalizations was evaluated. Primary study endpoint and clinical outcomes were compared to a Quarto II control cohort. RESULTS: Totally, 105 patients were included. The response rate was 64.6% (97.5% lower confidence bound 53%). Mean relative reduction in LVESV was 25.3%, and mean absolute increase in LVEF was 9.4%. The subjects with device programmed using anatomical approach showed a trend towards higher responder rate than those using the electrical approach (72% vs. 61.1%, p = 0.32). Finally, the combined incidence of mortality and or all-cause hospitalizations at 6 month was 12.4%. CONCLUSIONS: Early activation of MPP was not associated to an advantage increasing echocardiography responders to CRT at 6 months of follow-up. Nevertheless, patients programmed using widest pacing cathodes had a numerically higher responder rate. Finally, early activation of MPP was associated to a low incidence of clinical endpoints at 6 months of follow-up.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Estudos Prospectivos , Função Ventricular Esquerda/fisiologia , Volume Sistólico/fisiologia , Resultado do Tratamento , Dispositivos de Terapia de Ressincronização Cardíaca
3.
J Am Heart Assoc ; 10(1): e018108, 2021 01 05.
Artigo em Inglês | MEDLINE | ID: mdl-33356406

RESUMO

Background Large-scale studies describing modern populations using an implantable cardioverter-defibrillator (ICD) are lacking. We aimed to analyze the incidence of arrhythmia, device interventions, and mortality in a broad spectrum of real-world ICD patients with different heart disorders. Methods and Results The UMBRELLA study is a prospective, multicenter, nationwide study of contemporary patients using an ICD followed up by remote monitoring, with a blinded review of arrhythmic episodes. From November 2005 to November 2017, 4296 patients were followed up. After 46.6±27.3 months, 16 067 episodes of sustained ventricular arrhythmia occurred in 1344 patients (31.3%). Appropriate ICD therapy occurred in 27.3% of study population. Patients with ischemic cardiomyopathy (hazard ratio [HR], 1.51; 95% CI, 1.29-1.78), dilated cardiomyopathy (HR, 1.28; 95% CI, 1.07-1.53), and valvular heart disease (HR, 1.94; 95% CI, 1.43-2.62) exhibited a higher risk of appropriate ICD therapies, whereas patients with hypertrophic cardiomyopathy (HR, 0.72; 95% CI, 0.54-0.96) and Brugada syndrome (HR, 0.25; 95% CI, 0.14-0.45) showed a lower risk. All-cause death was 13.4% at follow-up. Ischemic cardiomyopathy (HR, 3.09; 95% CI, 2.58-5.90), dilated cardiomyopathy (HR, 3.33; 95% CI, 2.18-5.10), and valvular heart disease (HR, 3.97; 95% CI, 2.25-6.99) had the worst prognoses. Delayed high-rate detection was enabled in 39.7% of patients, and single-zone programming occurred in 52.6% of primary prevention patients. Both parameters correlated with lower risk of first appropriate ICD therapy, with no excess risk of mortality. The rate of inappropriate shocks at follow-up was low (6%) and did not differ among type of ICD but was lower in SmartShock-capable devices. Conclusions Irrespective of the cause, contemporary ICD patients with heart failure-related disorders had a similar risk of ICD life-saving interventions and death. Current ICD programming recommendations still need to be implemented. Registration URL: https://www.clinicaltrials.gov; Unique identifier: NTC01561144.


Assuntos
Desfibriladores Implantáveis , Cardioversão Elétrica , Taquicardia Ventricular , Estudos de Coortes , Desfibriladores Implantáveis/efeitos adversos , Desfibriladores Implantáveis/classificação , Desfibriladores Implantáveis/estatística & dados numéricos , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/métodos , Cardioversão Elétrica/estatística & dados numéricos , Análise de Falha de Equipamento , Feminino , Cardiopatias/classificação , Cardiopatias/complicações , Cardiopatias/mortalidade , Cardiopatias/terapia , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Mortalidade , Avaliação das Necessidades , Serviços Preventivos de Saúde/métodos , Serviços Preventivos de Saúde/estatística & dados numéricos , Medição de Risco , Espanha/epidemiologia , Análise de Sobrevida , Taquicardia Ventricular/epidemiologia , Taquicardia Ventricular/terapia
6.
Int J Cardiol ; 251: 45-50, 2018 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-29107360

RESUMO

BACKGROUND: We describe the feasibility of monitoring with a Textile Wearable Holter (TWH) in patients included in Crypto AF registry. METHODS: We monitored cryptogenic stroke patients from stroke onset (<3days) continuously during 28days. We employed a TWH composed by a garment and a recorder. We compared two garments (Lead and Vest) to assess rate of undiagnosed Atrial Fibrillation (AF) detection, monitoring compliance, comfortability (1 to 5 points), skin lesions, and time analyzed. We describe the timing of AF detection in three periods (0-3, 4-15 and 16-28days). RESULTS: The rate of undiagnosed AF detection with TWH was 21.9% (32 out of 146 patients who completed the monitoring). Global time compliance was 90% of the time expected (583/644h). The level of comfortability was 4 points (IQR 3-5). We detected reversible skin lesions in 5.47% (8/146). The comfortability was similar but time compliance (in hours) was longer in Vest group 591 (IQR [521-639]) vs. Lead 566 (IQR [397-620]) (p=0.025). Also, time analyzed was more prolonged in Vest group 497 (IQR [419-557]) vs. Lead (336h (IQR [140-520]) (p=0.001)). The incidence of AF increases from 5.6% (at 3days) to 17.5% (at 15th day) and up to 20.9% (at 28th day). The percentage of AF episodes detected only in each period was 12.5% (0-3days); 21.7% (4-15days) and 19% (16-28days). CONCLUSIONS: 28days Holter monitoring from the acute phase of the stroke was feasible with TWH. Following our protocol, only five patients were needed to screen to detected one case of AF.


Assuntos
Fibrilação Atrial/diagnóstico , Eletrocardiografia Ambulatorial/métodos , Sistema de Registros , Acidente Vascular Cerebral/diagnóstico , Têxteis , Doença Aguda , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/fisiopatologia , Eletrocardiografia Ambulatorial/instrumentação , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Masculino , Projetos Piloto , Estudos Prospectivos , Acidente Vascular Cerebral/fisiopatologia
9.
Pacing Clin Electrophysiol ; 39(7): 633-41, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27019211

RESUMO

BACKGROUND: Different types of ventricular arrhythmias (monomorphic ventricular tachycardia [VT], polymorphic VT, or ventricular fibrillation) can be detected by implantable cardiac defibrillators (ICDs) in fast VT zone. The efficacy of antitachycardia pacing (ATP) depends on the type of the treated arrhythmia. We hypothesized that an automatic algorithm based on morphological affinity of ICD far-field electrograms during tachycardia can predict ATP success and the need of shock. METHODS: The algorithm was evaluated on ventricular arrhythmias recorded in CareLink ICD remote monitoring system (Medtronic Inc., Minneapolis, MN, USA). Patients were selected if first ATP programmed was a burst of eight pulses at 88% coupling interval and if a far-field electrogram was available. The algorithm calculated a stability coefficient (SC) for all their stored ATP-treated fast ventricular arrhythmia (VA) episodes (LC 200-300 ms), analyzing the morphology homogeneity of the last eight recorded far-field electrograms before ventricular arrhythmias detection. RESULTS: Inclusion criteria were fulfilled by 717 patients from 29 centers. Three hundred and twenty fast VA were recorded in 103 patients. A higher SC was observed in episodes terminated with the first-ATP (0.78 [0.72-0.84] vs 0.74 [0.60-0.84]; P = 0.006). These differences were especially marked among the 62 episodes of very fast VA (CL ≤250 ms) (0.77 [0.74-0.85] vs 0.64 [0.51-0.8]; P = 0.006). In the multivariate analysis, a SC > 70% was independently associated with a higher likelihood of first-ATP success (odds ratio [OR] = 2.5; [95% confidence interval (CI) = 1.4-4.5], P = 0.001) and a lower need of shock (OR = 0.37; [95% CI = 0.2-0.7], P = 0.002). CONCLUSION: This automatic algorithm (stability coefficient) shows that ATP therapy response can be predicted in fast ventricular arrhythmias through morphology evaluation.


Assuntos
Algoritmos , Técnicas Eletrofisiológicas Cardíacas/métodos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/prevenção & controle , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/prevenção & controle , Estimulação Cardíaca Artificial , Desfibriladores Implantáveis , Diagnóstico por Computador/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde/métodos , Prognóstico , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espanha , Terapia Assistida por Computador/métodos , Resultado do Tratamento
10.
Arch Soc Esp Oftalmol ; 84(8): 407-10, 2009 Aug.
Artigo em Espanhol | MEDLINE | ID: mdl-19728243

RESUMO

CASE REPORT: A 20 year-old woman was submitted to resection of an ependymome of the fourth ventricle. After surgery the patient began to refer diplopia and oscillopsia. WEBINO syndrome (wall-eyed bilateral internuclear ophthalmoplegia), vertical nystagmus and skew deviation were diagnosed. DISCUSSION: WEBINO syndrome is considered a special form of bilateral internuclear ophthalmoplegia. It is characterized by bilateral absence of adduction, nystagmic abduction of both eyes, convergence deficiency and frequently exotropia. Ischemic, demyelinating and infectious etiologies have been described, but to our knowledge this is the first report of a postsurgical form of this syndrome.


Assuntos
Transtornos da Motilidade Ocular , Complicações Pós-Operatórias , Feminino , Humanos , Transtornos da Motilidade Ocular/diagnóstico , Complicações Pós-Operatórias/diagnóstico , Síndrome , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA