Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
1.
J Pharm Biomed Anal ; 221: 115034, 2022 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-36095884

RESUMO

The goal of this study was to develop a method for the simultaneous quantification of 23 commonly used antineoplastic drugs in a hospital pharmacy, using ultra-high pressure liquid chromatography separation coupled to tandem mass spectrometry detection (UHPLC-MS/MS). The following drugs were investigated: 5-fluorouracil, cytarabine, ganciclovir, gemcitabine, dacarbazine, methotrexate, pemetrexed, busulfan, topotecan, rentitrexed, ifosfamide, cyclophosphamide, etoposide, irinotecan, doxorubicin/epirubicin, vincristine, docetaxel, paclitaxel, daunorubicin, idarubicin, vinblastine, oxaliplatin and carboplatin. The chromatographic separation was performed on a phenyl-hexyl column (2.1 ×100 mm, 1.7 µm) with a gradient elution of methanol and water containing 10 mM ammonium formate adjusted to pH 4.9. All compounds were analyzed in less than 13 min and detected with a triple quadrupole mass spectrometer operating in MRM mode. Limits of detection (LODs) and limits of quantification (LOQs) were comprised between 0.01 and 5 ng.mL-1, and between 0.5 and 5 ng.mL-1, respectively. Accuracies ranged between 117% and 83% at the LOQ, intermediate and upper LOQ concentrations, with relative standard deviations (RSD) inferior to 8%, for all the antineoplastic drugs. Finally, the UHPLC-MS/MS method was successfully applied to the analysis of surface samples to evaluate the chemical contamination by these highly toxic compounds in a chemotherapy preparation unit in a hospital pharmacy with the purpose of monitoring the exposure of health care professionals.


Assuntos
Antineoplásicos , Espectrometria de Massas em Tandem , Antineoplásicos/análise , Bussulfano , Carboplatina , Cromatografia Líquida , Ciclofosfamida/análise , Citarabina , Dacarbazina , Daunorrubicina , Docetaxel , Doxorrubicina/análise , Epirubicina , Etoposídeo , Fluoruracila , Ganciclovir , Humanos , Idarubicina , Ifosfamida , Irinotecano , Metanol , Metotrexato , Oxaliplatina , Paclitaxel/análise , Pemetrexede , Espectrometria de Massas em Tandem/métodos , Topotecan , Vimblastina , Vincristina , Água
2.
Clin Pharmacol Ther ; 100(3): 295-304, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27264793

RESUMO

Ticagrelor is a potent antiplatelet drug metabolized by cytochrome (CYP)3A. It is contraindicated in patients with human immunodeficiency virus (HIV) because of the expected CYP3A inhibition by most protease inhibitors, such as ritonavir and an increased bleeding risk. In this study, a physiologically based pharmacokinetic (PBPK) model was created for ticagrelor and its active metabolite (AM). Based on the simulated interaction between ticagrelor 180 mg and ritonavir 100 mg, a lower dose of ticagrelor was calculated to obtain, when coadministered with ritonavir, the same pharmacokinetic (PK) and platelet inhibition as ticagrelor administered alone. A clinical study was thereafter conducted in healthy volunteers. Observed PK profiles of ticagrelor and its AM were successfully predicted with the model. Platelet inhibition was nearly complete in both sessions despite administration of a fourfold lower dose of ticagrelor in the second session. This PBPK model could be prospectively used to broaden the usage of ticagrelor in patients with ritonavir-treated HIV regardless of the CYP3A inhibition.


Assuntos
Adenosina/análogos & derivados , Inibidores do Citocromo P-450 CYP3A/farmacologia , Inibidores da Protease de HIV/farmacologia , Inibidores da Agregação Plaquetária/farmacocinética , Ritonavir/farmacologia , Adenosina/farmacocinética , Adulto , Área Sob a Curva , Plaquetas/efeitos dos fármacos , Meia-Vida , Humanos , Cetoconazol/farmacologia , Masculino , Taxa de Depuração Metabólica , Estudos Prospectivos , Ticagrelor , Adulto Jovem
3.
CPT Pharmacometrics Syst Pharmacol ; 3: e152, 2014 Dec 17.
Artigo em Inglês | MEDLINE | ID: mdl-25518025

RESUMO

Evaluation of a potential risk of metabolic drug-drug interactions (DDI) is of high importance in the clinical setting. In this study, a physiologically based pharmacokinetic (PBPK) model was developed for oxycodone and its two primary metabolites, oxymorphone and noroxycodone, in order to assess different DDI scenarios using published in vitro and in vivo data. Once developed and refined, the model was able to simulate pharmacokinetics of the three compounds and the DDI extent in case of coadministration with an inhibitor, as well as the oxymorphone concentration variation between CYP2D6 extensive metabolizers (EM) and poor metabolizers (PM). The reliability of the model was tested against published clinical studies monitoring different inhibitors and dose regimens, and all predicted area under the concentration-time curve (AUC) ratios were within the twofold acceptance range. This approach represents a strategy to evaluate the impact of coadministration of different CYP inhibitors using mechanistic incorporation of drug-dependent and system-dependent available in vitro and in vivo data.

4.
Eur J Pharm Biopharm ; 80(3): 544-52, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22155591

RESUMO

Cyclosporine A (CsA) has been demonstrated to be effective for the treatment of a variety of ophthalmological conditions, including ocular surface disorders such as the dry eye disease (DED). Since CsA is characterised by its low water solubility, the development of a topical ophthalmic formulation represents an interesting pharmaceutical question. In the present study, two different strategies to address this challenge were studied and compared: (i) a water-soluble CsA prodrug formulated within an aqueous solution and (ii) a CsA oil-in-water emulsion (Restasis, Allergan Inc., Irvine, CA). First, the prodrug formulation was shown to have an excellent ocular tolerance as well as no influence on the basal tear production; maintaining the ocular surface properties remained unchanged. Then, in order to allow in vivo investigations, a specific analytical method based on ultra high pressure liquid chromatography coupled with triple quadrupole mass spectrometer (UHPLC-MS/MS) was developed and optimised to quantify CsA in ocular tissues and fluids. The CsA ocular kinetics in lachrymal fluid for both formulations were found to be similar between 15 min and 48 h. The CsA ocular distribution study evidenced the ability of the prodrug formulation to penetrate into the eye, achieving therapeutically active CsA levels in tissues of both the anterior and posterior segments. In addition, the detailed analysis of the in vivo data using a bicompartmental model pointed out a higher bioavailability and lower elimination rate for CsA when it is generated from the prodrug than after direct application as an emulsion. The interesting in vivo properties displayed by the prodrug solution make it a safe and suitable option for the treatment of DED.


Assuntos
Ciclosporina/química , Ciclosporina/farmacologia , Síndromes do Olho Seco/tratamento farmacológico , Pró-Fármacos/química , Pró-Fármacos/farmacologia , Animais , Disponibilidade Biológica , Química Farmacêutica/métodos , Ciclosporina/farmacocinética , Síndromes do Olho Seco/metabolismo , Emulsões/química , Emulsões/farmacocinética , Emulsões/farmacologia , Olho/efeitos dos fármacos , Olho/metabolismo , Feminino , Cinética , Soluções Oftálmicas/química , Pró-Fármacos/farmacocinética , Coelhos , Ratos , Ratos Endogâmicos Lew , Solubilidade , Lágrimas/efeitos dos fármacos , Água/química
5.
Anal Chim Acta ; 702(2): 160-71, 2011 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-21839193

RESUMO

Evaluation of analytical results reliability is of core importance as crucial decisions are taken with them. From the various methodologies to evaluate the fitness of purpose of analytical methods, overall measurement uncertainty estimation is more and more applied. Overall measurement uncertainty allows to combine simultaneously the remaining systematic influences to the random sources of uncertainty and allows assessing the reliability of results generated by analytical methods. However there are various interpretations on how to estimate overall measurement uncertainty, and thus various models for estimating it. Each model together with its assumptions has great impacts on the risks to abusively declare that analytical methods are suitable for their intended purpose. This review paper aims at (i) summarizing the various models used to estimate overall measurement uncertainty, (ii) provide their pros and cons, (iii) review the main areas of application and (iv) as a conclusion provide some recommendations when evaluating overall measurement uncertainty.


Assuntos
Técnicas de Química Analítica/métodos , Modelos Estatísticos , Animais , Interpretação Estatística de Dados , Humanos , Controle de Qualidade , Reprodutibilidade dos Testes , Incerteza
6.
Clin Biochem ; 44(1): 45-53, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20705066

RESUMO

OBJECTIVES: Perform a comparison of results obtained with a LC-MS/MS method and a Remedi® instrument on clinical serum samples. DESIGN AND METHODS: Results obtained on 146 selected plasma samples were compared between the two methods. RESULTS: On the 336 positive identifications, 89% were obtained using the LC-MS/MS technique and 57% by the LC-DAD. Benzodiazepines were well recognized by LC-MS/MS. For some compounds such as antidepressant agents, sensitivity was improved using LC-MS/MS. Moreover, this method extended the panel of drugs detected in clinical toxicology. CONCLUSION: The new software platform developed for screening and identification of small molecules (SmileMS) allows an easy and reproducible detection of drugs and toxic compounds in blood for general unknown screening. It offers automated generation of reports, which makes the LC-MS/MS easier to use without having specialised skills in mass spectrometry. This LC-MS/MS screening method will be a reliable alternative to the Remedi® instrument in the global process of screening in emergency clinical toxicology laboratories.


Assuntos
Cromatografia Líquida , Preparações Farmacêuticas/análise , Espectrometria de Massas em Tandem , Humanos , Preparações Farmacêuticas/sangue
7.
Clin Biochem ; 44(1): 32-44, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20691172

RESUMO

OBJECTIVES: Evaluate a new LC-MS/MS screening method for drugs and drugs of abuse as an alternative to the existing methods used in clinical toxicology laboratories. DESIGN AND METHODS: The work was divided in two parts. The first part was dedicated to the technical development and evaluation of the method for which a set of 97 drugs and relevant metabolites was used to perform a complete investigation of matrix effects and lower limit of identification (LOI). The second part was a comparison of identified drugs between LC-MS/MS and Remedi® instrument on clinical serum samples. RESULTS: The method offers good performance allowing an automatic peak detection and compound identification. The limit of identification is equivalent to 50 µg/L for the majority of the studied compounds. The process efficiency (PE) is higher than 70% for 65% of the evaluated compounds. Thus, a sufficient detection capability in terms of limit of detection for identification and PE satisfied the expected performance. CONCLUSION: The described methodology allows the identification of the main drugs incriminated in intoxications within a quite short analysis time. The separation of most of the analytes is performed in 15 min. The procedure is sufficiently sensitive and selective.


Assuntos
Cromatografia Líquida , Preparações Farmacêuticas/análise , Espectrometria de Massas em Tandem , Humanos , Preparações Farmacêuticas/sangue , Extração em Fase Sólida , Transtornos Relacionados ao Uso de Substâncias/sangue
8.
Anal Bioanal Chem ; 399(8): 2719-30, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20953866

RESUMO

Nowadays, in forensic laboratories, heroin profiling is frequently carried out by gas chromatography coupled with mass spectrometry (GC-MS). This analytical technique is well established, provides good sensitivity and reproducibility, and allows the use of large databases. Despite those benefits, recently introduced analytical techniques, such as ultra-high-pressure liquid chromatography (UHPLC), could offer better chromatographic performance, which needs to be considered to increase the analysis throughput for heroin profiling. With the latter, chromatographic conditions were optimized through commercial modeling software and two atmospheric pressure ionization sources were evaluated. Data obtained from UHPLC-MS/MS were thus transferred, thanks to mathematical models to mimic GC-MS data. A calibration and a validation set of representative heroin samples were selected among the database to establish a transfer methodology and assess the models' abilities to transfer using principal component analysis and hierarchical classification analysis. These abilities were evaluated by computing the frequency of successful classification of UHPLC-MS/MS data among GC-MS database. Seven mathematical models were tested to adjust UHPLC-MS/MS data to GC-MS data. A simplified mathematical model was finally selected and offered a frequency of successful transfer equal to 95%.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Heroína/análise , Espectrometria de Massas em Tandem/métodos , Calibragem , Cromatografia Líquida de Alta Pressão/normas , Cromatografia Gasosa-Espectrometria de Massas , Modelos Teóricos , Análise de Componente Principal , Espectrometria de Massas em Tandem/normas
9.
Anal Bioanal Chem ; 398(5): 2163-71, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20835864

RESUMO

An automated in-capillary assay requiring very small quantities of reagents was developed for performing in vitro cytochrome P450 (CYP450) drug metabolism studies. The approach is based on the following: (i) hydrodynamic introduction of nanoliter volumes of substrate and enzyme solutions in the sandwich mode, within a capillary; (ii) mixing the reagents by diffusion across the interfaces between the injected solutions; (iii) collection of the capillary content at the end of the in-capillary assay; and (iv) off-line analysis of the incubation mixture by ultrahigh pressure liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). After optimizing the injection sequence of the reagents, the in-capillary approach was applied to the quantitative determination of the kinetics of drug metabolism reactions catalyzed by three CYP450 isozymes involved in human drug metabolism: CYP1A2, CYP2D6, and CYP3A4. It was demonstrated that this in-capillary method was able to provide similar kinetic parameters for CYP450 activity (e.g., Michaelis constants and turnover values) as the classical in vitro method, with a drastic reduction of reagent consumption.


Assuntos
Bioensaio/métodos , Sistema Enzimático do Citocromo P-450/análise , Cromatografia Líquida/métodos , Sistema Enzimático do Citocromo P-450/metabolismo , Humanos , Cinética , Espectrometria de Massas
10.
J Pharm Biomed Anal ; 53(5): 1278-87, 2010 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-20719445

RESUMO

The proportion of counterfeit medicines is dramatically increasing these last few years. According to numerous official sources, in some pharmaceutical wholesalers in African countries, the proportion has reached 80%. Unfortunately, this situation is far to be improved due to lack of suitable analytical equipment allowing rapid actions of the Regulatory Agencies based on scientific consideration, at affordable cost and all over the drug supply chain. For that purpose, a network group considered that mater by building a low-cost original capillary electrophoresis (CE) equipment equipped with a new deep UV detector based on LED technology. The generic conditions for analysis were investigated: capillary zone electrophoresis (CZE) performed at acidic pH for basic drug molecules (i.e., quinine, highly used as the last antimalarial rampart), basic pH for compounds such as furosemide (a common diuretic drug) and at neutral pH for a well known antibiotic combination, trimethoprim/sulfamethoxazol. To evaluate the ability of the CE equipment for quantification, a full validation and a method comparison study were carried out for the CZE method dedicated to quinine determination. The validation involved the use of accuracy profile and total error concept to monitor the adequacy of the results obtained by the new prototype. The method comparison was based on the Bland and Altman approach by comparing results obtained by the low-cost CE and a conventional set-up. Subsequent validation studies were realized with neutral and acidic drug molecules, each focusing on a single concentration level calibration curve in order to maintain as low as possible the expenses due to reagents and thus the cost of analysis, as important advantages of CE for drug quality control.


Assuntos
Química Farmacêutica/economia , Química Farmacêutica/normas , Medicamentos Falsificados/análise , Medicamentos Falsificados/economia , Custos e Análise de Custo/economia , Controle de Medicamentos e Entorpecentes , Eletroforese Capilar/economia , Eletroforese Capilar/normas , Controle de Qualidade , Reprodutibilidade dos Testes
11.
J Chromatogr A ; 1217(25): 4109-19, 2010 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-19939397

RESUMO

For doping control, analyses of samples are generally achieved in two steps: a rapid screening and, in the case of a positive result, a confirmatory analysis. A two-step methodology based on ultra-high-pressure liquid chromatography coupled to a quadrupole time-of-flight mass spectrometry (UHPLC-QTOF-MS) was developed to screen and confirm 103 doping agents from various classes (e.g., beta-blockers, stimulants, diuretics, and narcotics). The screening method was presented in a previous article as part I (i.e., Fast analysis of doping agents in urine by ultra-high-pressure liquid chromatography-quadrupole time-of-flight mass spectrometry. Part I: screening analysis). For the confirmatory method, basic, neutral and acidic compounds were extracted by a dedicated solid-phase extraction (SPE) in a 96-well plate format and detected by MS in the tandem mode to obtain precursor and characteristic product ions. The mass accuracy and the elemental composition of precursor and product ions were used for compound identification. After validation including matrix effect determination, the method was considered reliable to confirm suspect results without ambiguity according to the positivity criteria established by the World Anti-Doping Agency (WADA). Moreover, an isocratic method was developed to separate ephedrine from its isomer pseudoephedrine and cathine from phenylpropanolamine in a single run, what allowed their direct quantification in urine.


Assuntos
Anabolizantes/urina , Cromatografia Líquida de Alta Pressão/métodos , Dopagem Esportivo/prevenção & controle , Espectrometria de Massas/métodos , Detecção do Abuso de Substâncias/métodos , Humanos
12.
J Chromatogr A ; 1216(20): 4423-33, 2009 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-19342059

RESUMO

The general strategy to perform anti-doping analyses of urine samples starts with the screening for a wide range of compounds. This step should be fast, generic and able to detect any sample that may contain a prohibited substance while avoiding false negatives and reducing false positive results. The experiments presented in this work were based on ultra-high-pressure liquid chromatography coupled to hybrid quadrupole time-of-flight mass spectrometry. Thanks to the high sensitivity of the method, urine samples could be diluted 2-fold prior to injection. One hundred and three forbidden substances from various classes (such as stimulants, diuretics, narcotics, anti-estrogens) were analysed on a C(18) reversed-phase column in two gradients of 9min (including two 3min equilibration periods) for positive and negative electrospray ionisation and detected in the MS full scan mode. The automatic identification of analytes was based on retention time and mass accuracy, with an automated tool for peak picking. The method was validated according to the International Standard for Laboratories described in the World Anti-Doping Code and was selective enough to comply with the World Anti-Doping Agency recommendations. In addition, the matrix effect on MS response was measured on all investigated analytes spiked in urine samples. The limits of detection ranged from 1 to 500ng/mL, allowing the identification of all tested compounds in urine. When a sample was reported positive during the screening, a fast additional pre-confirmatory step was performed to reduce the number of confirmatory analyses.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Dopagem Esportivo , Espectrometria de Massas/métodos , Detecção do Abuso de Substâncias/métodos , Urina/química , Diuréticos/urina , Entorpecentes/urina
13.
J Chromatogr A ; 1216(13): 2695-9, 2009 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-18962647

RESUMO

The aim of this work was to develop a trypsin-based micro-immobilized enzyme reactor prepared on a monolithic ethylenediamine BIA Separations CIM (convective interaction media) minidisk. The micro-immobilized enzyme reactor (IMER) was integrated in a liquid chromatography system hyphenated to electrospray ionization tandem mass spectrometry to carry out on-line protein digestion and identification. The performance of this IMER was compared with that obtained using a previously developed bioreactor prepared on a conventional CIM ethylenediamine disk and with that of the commercially available Poroszyme immobilized trypsin cartridge. In this work, we showed how different proteins were identified with good recoveries using a digestion time of 10 min only.


Assuntos
Cromatografia Líquida , Enzimas Imobilizadas/química , Etilenodiaminas/química , Mapeamento de Peptídeos , Tripsina/química , Proteínas/química , Espectrometria de Massas por Ionização por Electrospray , Espectrometria de Massas em Tandem
14.
J Chromatogr A ; 1206(1): 2-10, 2008 Oct 03.
Artigo em Inglês | MEDLINE | ID: mdl-18556005

RESUMO

Two cytochrome P450 (CYP)-based immobilized enzyme reactors (IMERs) were developed to perform automated on-line phase I drug metabolism studies. For this purpose, biotinylated recombinant CYP2D6 or CYP3A4 reconstituted systems were anchored to the surface of two monolithic mini-columns (2 mm x 6 mm I.D.), which had been covalently grafted with NeutrAvidin. After optimization of immobilization conditions, the obtained IMERs were integrated on-line into a LC hyphenated to an electrospray ionization MS/MS system. Studies with probe substrates and a known competitive inhibitor were performed, showing the potential of CYP-based IMERs in drug metabolism. In the optimized conditions, ca. 15 experiments were carried out with each bioreactor.


Assuntos
Reatores Biológicos , Cromatografia Líquida/métodos , Citocromo P-450 CYP2D6/metabolismo , Citocromo P-450 CYP3A/metabolismo , Avaliação Pré-Clínica de Medicamentos/métodos , Enzimas Imobilizadas/metabolismo , Espectrometria de Massas por Ionização por Electrospray/métodos , Avidina , Biotinilação , Cromatografia Líquida/instrumentação , Inibidores do Citocromo P-450 CYP2D6 , Inibidores do Citocromo P-450 CYP3A , Inibidores Enzimáticos/farmacologia , Estabilidade Enzimática , Humanos , Cinética , Microssomos Hepáticos/química , Proteínas Recombinantes/metabolismo , Espectrometria de Massas por Ionização por Electrospray/instrumentação
15.
J Chromatogr A ; 1192(1): 103-12, 2008 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-18395734

RESUMO

The recent developments in liquid chromatography (LC) are mainly dedicated to both system miniaturization (micro-, capillary-, and nano-LC) and analysis time decrease (fast-, and ultra-fast-LC). For the latter, several strategies can be used, and high temperature liquid chromatography (HTLC) seems very promising and easy to implement, especially in miniaturized system. In LC, the evaporative light scattering detector (ELSD) is considered an attractive alternative to conventional detector such as UV-vis due to its versatility and quasi-universality. Therefore, the compatibility of ELSD with micro-LC and micro-HTLC was investigated for several pharmaceutical compounds of interest. The nebulization process appeared to be the most critical parameter for performing the coupling and maintaining an efficient separation. Therefore, appropriate modifications in the nebulization cell geometry were brought to make ELSD fully compatible with micro-LC. The impact of optimized nebulization cell on chromatographic performance was evaluated in terms of efficiency and sensitivity. Finally, highly efficient, sensitive and fast separations of pharmaceutical drugs were performed with both techniques and the customized nebulization cell design.


Assuntos
Cromatografia Líquida/métodos , Artemisininas/isolamento & purificação , Luz , Miniaturização , Análise Multivariada , Nebulizadores e Vaporizadores , Preparações Farmacêuticas/isolamento & purificação , Espalhamento de Radiação , Temperatura
16.
J Pharm Biomed Anal ; 48(2): 398-407, 2008 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-18242915

RESUMO

The preparation and characterization of three trypsin-based monolithic immobilized enzyme reactors (IMERs) developed to perform rapid on-line protein digestion and peptide mass fingerprinting (PMF) are described. Trypsin (EC 3.4.21.4) was covalently immobilized on epoxy, carbonyldiimidazole (CDI) and ethylenediamine (EDA) Convective Interaction Media (CIM) monolithic disks. The amount of immobilized enzyme, determined by spectrophotometric measurements at 280nm, was comprised between 0.9 and 1.5mg per disk. Apparent kinetic parameters Km* and Vmax*, as well as apparent immobilized trypsin BAEE-units, were estimated in flow-through conditions using N-alpha-benzoyl-L-arginine ethyl ester (BAEE) as a low molecular mass substrate. The on-line digestion of five proteins (cytochrome c, myoglobin, alpha1-acid glycoprotein, ovalbumin and albumin) was evaluated by inserting the IMERs into a liquid chromatography system coupled to an electrospray ionization ion-trap mass spectrometer (LC-ESI-MS/MS) through a switching valve. Results were compared to the in-solution digestion in terms of obtained scores, number of matched queries and sequence coverages. The most efficient IMER was obtained by immobilizing trypsin on a CIM EDA disk previously derivatized with glutaraldehyde, as a spacer moiety. The proteins were recognized by the database with satisfactory sequence coverage using a digestion time of only 5min. The repeatability of the digestion (R.S.D. of 5.4% on consecutive injections of myoglobin 12microM) and the long-term stability of this IMER were satisfactory since no loss of activity was observed after 250 injections.


Assuntos
Enzimas Imobilizadas/química , Proteínas/análise , Tripsina/química , Sequência de Aminoácidos , Dados de Sequência Molecular , Espectrometria de Massas por Ionização por Electrospray
17.
Acta Clin Belg ; 61 Suppl 1: 60-2, 2006.
Artigo em Francês | MEDLINE | ID: mdl-16700155

RESUMO

Three different approaches for the estimation of uncertainty measurements using the same analytical method were compared, namely validation, robustness and inter-laboratory studies. The uncertainty obtained with the robustness study! predicted well the uncertainty of the inter-laboratory study. On the other hand, the uncertainty estimation obtained with the validation study is lower than those obtained with the two other approaches but is still acceptable as long as the analytical method will be used in a single laboratory.


Assuntos
Cromatografia Líquida/estatística & dados numéricos , Incerteza , Estatística como Assunto/métodos
18.
Talanta ; 68(4): 1166-75, 2006 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-18970447

RESUMO

This article presents the validation results of a chiral liquid chromatographic (LC) method previously developed for the quantitative determination of R-timolol in S-timolol maleate samples. A novel validation strategy based on the accuracy profiles was used to select the most appropriate regression model, to assess the method accuracy within well defined acceptance limits and to determine the limits of quantitation as well as the concentration range. The validation phase was completed by the investigation of the risk profiles of various acceptable regression models in order to ensure the risk of obtaining the future measurements outside the acceptance limits fixed a priori. On the other hand, the present paper also shows how data used in this validation approach can be used to estimate the measurement uncertainty. The uncertainty derived from beta-expectation tolerance interval (sigma(Tol)(2)), which is equal to the uncertainty of measurements as well as the expanded uncertainty (U(x)) using a coverage factor k=2 was estimated. The uncertainty estimates obtained from validation data were finally compared with those obtained from interlaboratory and robustness studies.

19.
Artigo em Inglês | MEDLINE | ID: mdl-16140045

RESUMO

A simple, sensitive and reliable HPLC ion-pairing method with fluorescence detection, was developed for penciclovir determination in plasma and aqueous humor, with a Zorbax SB-aq C18 (100 mmx2.1 mm) column. Plasma samples were treated by solid-phase extraction with Oasis MCX (30 mg) cartridges. Ganciclovir, an antiviral drug structurally related to penciclovir, was used as internal standard (I.S.). Aqueous humor samples were directly injected into the chromatographic system. Separation was performed by a gradient elution with a mobile phase consisting of a mixture of acetonitrile and phosphate buffer 50mM containing 5mM of sodium octanesulfonate, pH 2.0, at a flow rate of 0.3 ml/min. The method was validated and showed good performances in terms of linearity, sensitivity, precision and trueness. Quantification limit was obtained at 0.05 microg/ml for aqueous humor and at 0.1 microg/ml for plasma. Finally, the proposed analytical method was used to measure penciclovir in clinical samples for a pharmacokinetic study, after oral administration of famciclovir.


Assuntos
Aciclovir/análogos & derivados , Humor Aquoso/química , Cromatografia Líquida de Alta Pressão/métodos , Aciclovir/análise , Aciclovir/sangue , Estabilidade de Medicamentos , Ganciclovir/análise , Guanina , Humanos , Concentração de Íons de Hidrogênio , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espectrometria de Fluorescência , Temperatura
20.
Eur J Pharm Biopharm ; 59(1): 51-6, 2005 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-15567301

RESUMO

The aim of this study was to evaluate the rate and mechanism of conversion of two water-soluble prodrugs of cyclosporine A (CsA) intended for topical delivery to the eye. The new molecules were designed according to the double prodrug concept: a solubilizing moiety was grafted onto CsA via an ester function, which could be hydrolysed via a two-step process (enzymatic and chemical). Prodrug solutions were prepared extemporaneously in an isotonic and neutral aqueous medium compatible with ophthalmic use. The rates of conversion into the parent molecule were determined by incubating the prodrugs in fresh rabbit or human tears or in a phosphate buffer solution (PBS) at pH 7.4. Both prodrugs were converted into CsA within the first minute in the presence of rabbit tears with rate constants of k=5.9x10(-3)min(-1) and k=3.8x10(-3)min(-1), respectively, for UNIL088 and UNIL089, whereas chemical conversion in PBS was negligible (k=0.5x10(-3)min(-1) for both molecules). Incubation of UNIL088 in human tears showed a significantly high conversion rate. It is concluded that the developed double prodrugs underwent a bioconversion in physiological media and thus represent promising candidates for topical delivery of CsA to the eye.


Assuntos
Ciclosporina/farmacocinética , Pró-Fármacos/farmacocinética , Lágrimas/metabolismo , Animais , Ciclosporina/química , Humanos , Pró-Fármacos/química , Coelhos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA