Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Nat Commun ; 15(1): 4224, 2024 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-38762522

RESUMO

Waning antibody responses after COVID-19 vaccination combined with the emergence of the SARS-CoV-2 Omicron lineage led to reduced vaccine effectiveness. As a countermeasure, bivalent mRNA-based booster vaccines encoding the ancestral spike protein in combination with that of Omicron BA.1 or BA.5 were introduced. Since then, different BA.2-descendent lineages have become dominant, such as XBB.1.5, JN.1, or EG.5.1. Here, we report post-hoc analyses of data from the SWITCH-ON study, assessing how different COVID-19 priming regimens affect the immunogenicity of bivalent booster vaccinations and breakthrough infections (NCT05471440). BA.1 and BA.5 bivalent vaccines boosted neutralizing antibodies and T-cells up to 3 months after boost; however, cross-neutralization of XBB.1.5 was poor. Interestingly, different combinations of prime-boost regimens induced divergent responses: participants primed with Ad26.COV2.S developed lower binding antibody levels after bivalent boost while neutralization and T-cell responses were similar to mRNA-based primed participants. In contrast, the breadth of neutralization was higher in mRNA-primed and bivalent BA.5 boosted participants. Combined, our data further support the current use of monovalent vaccines based on circulating strains when vaccinating risk groups, as recently recommended by the WHO. We emphasize the importance of the continuous assessment of immune responses targeting circulating variants to guide future COVID-19 vaccination policies.


Assuntos
Anticorpos Neutralizantes , Anticorpos Antivirais , Vacinas contra COVID-19 , COVID-19 , Imunização Secundária , Imunogenicidade da Vacina , SARS-CoV-2 , Humanos , COVID-19/imunologia , COVID-19/prevenção & controle , COVID-19/virologia , SARS-CoV-2/imunologia , SARS-CoV-2/genética , Vacinas contra COVID-19/imunologia , Vacinas contra COVID-19/administração & dosagem , Anticorpos Neutralizantes/imunologia , Anticorpos Neutralizantes/sangue , Anticorpos Antivirais/imunologia , Anticorpos Antivirais/sangue , Feminino , Masculino , Adulto , Pessoa de Meia-Idade , Glicoproteína da Espícula de Coronavírus/imunologia , Glicoproteína da Espícula de Coronavírus/genética , Linfócitos T/imunologia , Vacinação
2.
Front Immunol ; 14: 1254659, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38239369

RESUMO

Background: Data on cellular response and the decay of antibodies and T cells in time are scarce in lung transplant recipients (LTRs). Additionally, the development and durability of humoral and cellular immune responses have not been investigated in patients on the waitlist for lung transplantation (WLs). Here, we report our 6-month follow-up of humoral and cellular immune responses of LTRs and WLs, compared with controls. Methods: Humoral responses to two doses of the mRNA-1273 vaccination were assessed by determining spike (S)-specific IgG antibodies and neutralizing antibodies. Cellular responses were investigated by interferon gamma (IFN-γ) release assay (IGRA) and IFN-γ ELISpot assay at 28 days and 6 months after the second vaccination. Results: In LTRs, the level of antibodies and T-cell responses was significantly lower at 28 days after the second vaccination. Also, WLs had lower antibody titers and lower T-cell responses compared with controls. Six months after the second vaccination, all groups showed a decrease in antibody titers and T-cell responses. In WLs, the rate of decline of neutralizing antibodies and T-cell responses was significantly higher than in controls. Conclusion: Our results show that humoral and cellular responses in LTRs, if they develop, decrease at rates comparable with controls. In contrast, the inferior cellular responses and the rapid decay of both humoral and cellular responses in the WL groups imply that WLs may not be protected adequately by two vaccinations and repeat boostering may be necessary to induce protection that lasts beyond the months immediately post-transplantation.


Assuntos
COVID-19 , Transplantados , Humanos , Vacinas contra COVID-19 , Listas de Espera , Seguimentos , COVID-19/prevenção & controle , Vacinação , Anticorpos Neutralizantes , Imunidade Celular , Pulmão
3.
J Clin Virol ; 120: 78-83, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31590114

RESUMO

BACKGROUND: Tick-borne encephalitis (TBE) is an infectious disease endemic to large parts of Europe and Asia. Diagnosing TBE often relies on the detection of TBEV-specific antibodies in serum and cerebrospinal fluid (CSF) as viral genome is mostly not detectable once neurological symptoms occur. OBJECTIVES: We evaluated the performance of TBEV IgM and IgG ELISAs in both serum and CSF of confirmed TBEV patients and discuss the role of (CSF) serology in TBEV diagnostics. STUDY DESIGN: For the assay evaluation we collected specimen from confirmed TBEV patients. Assay specificity was assessed using sera from patients with a related flavivirus infection or other acute infection. A selected ELISA assay was used to analyze TBEV-specific antibodies in CSF and to evaluate the use in confirming TBE diagnosis. RESULTS: In this study the overall sensitivity of the IgM TBEV ELISAs was acceptable (94 -100 %). Four out of five IgM ELISA's demonstrated an excellent overall specificity from 94 -100% whereas a low overall specificity was observed for the IgG TBEV ELISAs (30-71%). Intrathecal antibody production against TBEV was demonstrated in a subset of TBE patients. CONCLUSIONS: In four out of five ELISAs, IgM testing in serum and CSF of TBE patients is specific and confirmative. The lack of IgG specificity in all ELISAs emphasizes the need of confirmatory testing by virus neutralisation, depending on the patient's background and the geographic location of exposure to TBEV. A CSF-serum IgG antibody index can support the diagnosis specifically in chronic disease or once IgM has disappeared.


Assuntos
Vírus da Encefalite Transmitidos por Carrapatos/imunologia , Encefalite Transmitida por Carrapatos/diagnóstico , Imunoglobulina M/sangue , Imunoglobulina M/líquido cefalorraquidiano , Anticorpos Antivirais/sangue , Anticorpos Antivirais/líquido cefalorraquidiano , Encefalite Transmitida por Carrapatos/imunologia , Ensaio de Imunoadsorção Enzimática , Feminino , Humanos , Imunoglobulina G/sangue , Imunoglobulina G/líquido cefalorraquidiano , Masculino , Sensibilidade e Especificidade
4.
Sex Transm Infect ; 94(5): 331-333, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28062734

RESUMO

INTRODUCTION: The Alere HIV-1/2 Antigen/Antibody Combo point-of-care test is a commercially available 4th-generation rapid test for the diagnosis of HIV infection, including acute infection. We evaluated the sensitivity of this test in samples from patients with acute, recent or chronic HIV-1 infection. METHODS: A validation of the test was performed using 89 HIV-positive serum samples collected in 2008-2016, that were stored at -20°C. Twenty-three samples were only p24-positive (acute infection); 49 samples were antibody-positive and p24-positive (recent infection); 17 samples were only antibody-positive (chronic infection). HIV infection was confirmed by standard-of-care assays and PCR. Samples came from patients attending an outpatient clinic for STDs at the Public Health Department and from patients within the Erasmus Medical Center, Rotterdam, the Netherlands. RESULTS: The overall sensitivity of the test for diagnosing HIV infection based on detection of p24 antigen and/or antibodies was 92% (95% CI 86% to 98%) (82/89). In acute sera with only p24 antigen positivity, the sensitivity of the test decreased to 65% (95% CI 46% to 85%) (15/23). When both antibody and antigen testing were positive, the p24 sensitivity was only 24% (95% CI 12% to 36%) (12/49), but in these sera the final test result was positive in all sera (49/49) due to the positive antibody component. CONCLUSIONS: In a laboratory setting, this test has an overall sensitivity of 92% to detect any stage of HIV-1 infection using sera specimens. It performs relatively well in detecting early HIV and may be beneficial as an initial screening in patients with a recent exposure to HIV. Additional testing in a laboratory setting remains mandatory as a proportion of acute HIV-1 infections are missed with this test.


Assuntos
Anticorpos Anti-HIV/sangue , Proteína do Núcleo p24 do HIV/sangue , Infecções por HIV/diagnóstico , HIV-1 , Testes Imediatos , Soro , Preservação de Sangue/normas , Infecções por HIV/sangue , Infecções por HIV/imunologia , HIV-1/imunologia , Humanos , Masculino , Programas de Rastreamento , Sistemas Automatizados de Assistência Junto ao Leito/normas , Sistemas Automatizados de Assistência Junto ao Leito/estatística & dados numéricos , Testes Imediatos/normas , Kit de Reagentes para Diagnóstico/normas , Kit de Reagentes para Diagnóstico/estatística & dados numéricos , Estudos Retrospectivos , Sensibilidade e Especificidade , Testes Sorológicos/instrumentação , Testes Sorológicos/métodos , Testes Sorológicos/estatística & dados numéricos , Soro/imunologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA