Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Br J Radiol ; 97(1156): 868-873, 2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38400772

RESUMO

PURPOSE: To evaluate intra-patient and interobserver agreement in patients who underwent liver MRI with gadoxetic acid using two different multi-arterial phase (AP) techniques. METHODS: A total of 154 prospectively enrolled patients underwent clinical gadoxetic acid-enhanced liver MRI twice within 12 months, using two different multi-arterial algorithms: CAIPIRINHA-VIBE and TWIST-VIBE. For every patient, breath-holding time, body mass index, sex, age were recorded. The phase without contrast media and the APs were independently evaluated by two radiologists who quantified Gibbs artefacts, noise, respiratory motion artefacts, and general image quality. Presence or absence of Gibbs artefacts and noise was compared by the McNemar's test. Respiratory motion artefacts and image quality scores were compared using Wilcoxon signed rank test. Interobserver agreement was assessed by Cohen kappa statistics. RESULTS: Compared with TWIST-VIBE, CAIPIRINHA-VIBE images had better scores for every parameter except higher noise score. Triple APs were always acquired with TWIST-VIBE but failed in 37% using CAIPIRINHA-VIBE: 11% have only one AP, 26% have two. Breath-holding time was the only parameter that influenced the success of multi-arterial techniques. TWIST-VIBE images had worst score for Gibbs and respiratory motion artefacts but lower noise score. CONCLUSION: CAIPIRINHA-VIBE images were always diagnostic, but with a failure of triple-AP in 37%. TWIST-VIBE was successful in obtaining three APs in all patients. Breath-holding time is the only parameter which can influence the preliminary choice between CAIPIRINHA-VIBE and TWIST-VIBE algorithm. ADVANCES IN KNOWLEDGE: If the patient is expected to perform good breath-holds, TWIST-VIBE is preferable; otherwise, CAIPIRINHA-VIBE is more appropriate.


Assuntos
Gadolínio DTPA , Aumento da Imagem , Interpretação de Imagem Assistida por Computador , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Aumento da Imagem/métodos , Reprodutibilidade dos Testes , Imageamento por Ressonância Magnética/métodos , Meios de Contraste , Suspensão da Respiração , Artefatos , Fígado/diagnóstico por imagem
2.
World J Hepatol ; 14(9): 1790-1803, 2022 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-36185716

RESUMO

BACKGROUND: Although stereotactic body radiation therapy (SBRT) is increasingly used, its application has not yet been regulated by the main international guidelines, leaving the decision to multidisciplinary teams. AIM: To assess magnetic resonance imaging (MRI) features of hepatocellular carcinoma (HCC) treated with SBRT, highlighting the efficacy of the treatment and the main aspects of the lesion before and after the procedure. METHODS: As part of a retrospective study, 49 patients who underwent SBRT for HCC between January 2013 and November 2019 were recruited. Each patient underwent a pre-treatment MRI examination with a hepatospecific contrast agent and a similar follow-up examination within 6 mo of therapy. In addition, 22 patients underwent a second follow-up examination after the first 6 mo. The following characteristics were analysed: Features analysed compared to pre-treatment MRI examination, presence or absence of infield and outfield progression, ring-like enhancement, signal hyperintensity in T2-weighted sequences in the perilesional parenchyma, capsular retraction, and "band" signal hypointensity in T1-weighted gradient echo fat saturated sequences obtained during hepatobiliary excretion. RESULTS: Signal hyperintensity in the T2-weighted sequences showed a statistically significant reduction in the number of lesions at the post-SBRT first control (P = 0.0006). Signal hyperintensity in diffusion-weighted imaging-weighted sequences was decreased at MRI first control (P < 0.0001). A statistically significant increase of apparent diffusion coefficient values from a median of 1.01 to 1.38 at the first post-control was found (P < 0.0001). Capsular retraction was increased at the late evaluation (P = 0.006). Band-like signal hypointensity in the hepatobiliary phase was present in 94% at the late control (P = 0.006). The study of the risk of outfield progression vs infield progression revealed a hazard ratio of 9. CONCLUSION: The efficacy of SBRT should be evaluated not in the first 6 mo, but at least 9 mo post-SBRT, when infield progression persists at very low rates while the risk of outfield progression increases significantly.

3.
Radiol Med ; 126(1): 55-62, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32495272

RESUMO

PURPOSE: The purpose of this study was to verify the maintenance of low-contrast detectability at different CT dose reduction levels, in patients of different sizes, as a consequence of the application of iterative reconstruction at different strengths combined with tube current modulation. METHODS: Anthropomorphic abdominal phantoms of two sizes (small and large) were imaged at a fixed noise with iterative algorithm ASIR-V percentages in the range between 0 and 70% and corresponding dose reductions in the range of 0-83%. A total of 1400 images with and without liver low-contrast simulated lesions were evaluated by five radiologists, using the receiver operating characteristics (ROC) paradigm and evaluating the area under the ROC curve (AUC). The human observer results were then compared with AUC obtained with a channelized Hotelling observer (CHO). CNR values were also calculated. RESULTS: For the small phantom, the AUC values lie between 0.90 and 0.93 for human evaluations of images acquired without iterative reconstruction, with 30% ASIR-V and with 50% ASIR-V. The AUC decreased significantly to 0.81 (p = 0.0001) at 70% ASIR-V. The CHO results were in coherence with human observer scores. Also, similar results were observed for the large size phantom. CNR values were stable for the different ASIR-V percentages. CONCLUSIONS: The iterative algorithm maintained the low-contrast detectability up to a dose reduction of about 70%, following application of a 50% ASIR-V combined with automatic tube current modulation, regardless of the phantom size. At further dose reductions using greater iterative percentages, a significant decrease in detectability was observed.


Assuntos
Abdome/diagnóstico por imagem , Tamanho Corporal , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X , Algoritmos , Antropometria , Humanos , Imagens de Fantasmas , Doses de Radiação
4.
Radiol Med ; 124(10): 1043-1048, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31270723

RESUMO

AIM: Evaluating clinical and technical factors affecting thermal ablation of B-Mode/CEUS inconspicuous HCC nodules, relying only on fusion imaging (FI) performed under conscious sedation and using previously acquired CT or MR. MATERIALS AND METHODS: Among 367 HCC nodules treated in the study period, data of 37 B-mode/CEUS undetectable HCC nodules treated with FI-guided ablation were extracted from our prospectively collected institutional database. Analyzed variables included patients' sex, age, cirrhosis etiology, Child-Pugh status, size of the lesion, liver segment, subcapsular or central liver site, type of imaging used for fusion (MR/CT), and the presence of surrounding anatomical landmarks (SAL) < 3 cm from the index lesion. RESULTS: The primary efficacy was 59.4% (22/37 nodules); nine lesions (24.3%) were partially ablated (PA), six lesions (16.7%) were mistargeted (MA). Eight nodules were retreated with a CA obtained in all cases (100% CA, secondary efficacy in 30/37-81.1%). LTP was observed in 2/30 cases (6.7%). Two minor complications were registered (Clavien-Dindo, Grade1, CIRSE Classification Grade 2). SAL were related to a better ablation outcome (37.5% vs 84.6% p = 0.01). No differences were observed between CA group and PA-MA group in terms of lesion size (15.4 mm vs 14.9 mm p = 0.63), liver segment (p = 0.58), subcapsular or central liver site (8/22 36% vs 4/15 26.7% p = 0.84), and imaging (MR vs CT, p = 0.72). CONCLUSION: Even in the presence of potentially critical conditions (completely B-Mode/CEUS inconspicuous nodules, spontaneous breathing, and previously acquired CT or MRI), FI-only guidance is safe and allows having good primary, secondary efficacy and LTP rates. The outcome of the procedure is heavily affected by the presence of SAL.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/cirurgia , Ablação por Cateter/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Imagem Multimodal , Ultrassonografia/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Pontos de Referência Anatômicos , Carcinoma Hepatocelular/patologia , Sedação Consciente , Meios de Contraste , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Neoplasias Hepáticas/patologia , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Fosfolipídeos , Estudos Prospectivos , Hexafluoreto de Enxofre , Tomografia Computadorizada por Raios X , Resultado do Tratamento
5.
Hum Genet ; 111(6): 521-37, 2002 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-12436243

RESUMO

Catechol-O-methyl transferase (COMT) catalyzes the first step in one of the major pathways in the degradation of catecholamines. The COMT gene on chromosome 22 has been considered a candidate gene for many neuropsychiatric disorders, in part because an exon 4 single nucleotide polymorphism (SNP) in COMT causes an amino acid substitution associated with significantly altered enzyme activity. This functional variant, detected as an NlaIII restriction site polymorphism (RSP), is polymorphic in populations from around the world. A four-site haplotype spanning 28 kb effectively encompasses COMT. This haplotype is comprised of two novel polymorphisms [a tetranucleotide short tandem repeat polymorphism (STRP) in intron 1 and a HindIII RSP at the 5' end of COMT], the NlaIII site, and another previously published site - a BglI RSP at the 3' end of the gene. Overall linkage disequilibrium (LD) for this haplotype is strong and significant in 32 population samples from around the world. Conditional probabilities indicate that, in spite of moderate to strong disequilibrium in most non-African populations, the NlaIII site, although often used for prediction, would not always be a reliable predictor of allelic variation at the other sites. Because other functional variation might exist, especially regulatory variation, these findings indicate that haplotypes would be more effective indicators of possible involvement of COMT in disease etiology.


Assuntos
Catecol O-Metiltransferase/genética , Variação Genética , Desequilíbrio de Ligação , Regiões Promotoras Genéticas , Sequência de Bases , Primers do DNA , Haplótipos , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA