RESUMO
A new rapid method which allows simultaneous one step detection of two analytes of different nature (2,4,6,-trichlorophenol (TCP) and ochratoxin A (OTA)) in red wine was developed. It was based on a column test with three separate immunolayers: two test layers and one control layer. Each layer consisted of sepharose gel with immobilized anti-OTA (OTA test layer), anti-TCP (TCP test layer) or anti-HRP (control layer) antibodies. Analytes bind to the antibodies in the corresponding test layer while sample flows through the column. Then a mixture of OTA-HRP and TCP-HRP in appropriate dilutions was used, followed by the application of chromogenic substrate. Colour development of the test layer occurred when the corresponding analyte was absent in the sample. HRP-conjugates bound to anti-HRP antibody in the control layer independently of presence or absence of analytes and a blue colour developed in the control layer. Cut-off values for both analytes were 2 microg L(-1). The described method was applied to the simultaneous detection of TCP and OTA in wine samples. To screen the analytes in red wine samples, clean-up columns were used for sample pre-treatment in combination with the test column. Results were confirmed by chromatographic methods.
Assuntos
Clorofenóis/análise , Ocratoxinas/análise , Vinho/análise , Anticorpos/imunologia , Clorofenóis/imunologia , Géis/química , Imunoensaio , Ocratoxinas/imunologiaRESUMO
Gel-based and membrane-based flow-through immunoassay formats were investigated for rapid ochratoxin A (OTA) detection in red wine. The flow-through set-up consisted of an antibody containing gel or membrane placed at the bottom of a standard solid-phase extraction column (i.e. the flow-through column), combined with a clean-up column. Different clean-up methods were studied for red wine clarification and purification. The optimal method consisted of passing wine, diluted with an aqueous solution containing 1% polyethylene glycol (PEG 6000) and 5% sodium hydrogencarbonate, through strong anion exchange (SAX) silica. An immunoassay for OTA detection in red wine was optimized and a cut-off level at 2 microg L(-1) according to EU legislation was achieved with both formats. A more significant colour difference between blank and spiked samples was observed for the gel-based assay making this superior to the membrane-based assay. The proposed rapid gel-based test was compared with a standard immunoaffinity column-high-performance liquid chromatography-fluorescent detection (IAC-HPLC-FLD) method and a good correlation of the results was obtained for naturally contaminated wine samples.