Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 10(1): 934, 2020 01 22.
Artigo em Inglês | MEDLINE | ID: mdl-31969626

RESUMO

Josephson junctions act as a natural spiking neuron-like device for neuromorphic computing. By leveraging the advances recently demonstrated in digital single flux quantum (SFQ) circuits and using recently demonstrated magnetic Josephson junction (MJJ) synaptic circuits, there is potential to make rapid progress in SFQ-based neuromorphic computing. Here we demonstrate the basic functionality of a synaptic circuit design that takes advantage of the adjustable critical current demonstrated in MJJs and implement a synaptic weighting element. The devices were fabricated with a restively shunted Nb/AlOx-Al/Nb process that did not include MJJs. Instead, the MJJ functionality was tested by making multiple circuits and varying the critical current, but not the external shunt resistance, of the oxide Josephson junction that represents the MJJ. Experimental measurements and simulations of the fabricated circuits are in good agreement.

2.
Artigo em Inglês | MEDLINE | ID: mdl-35573857

RESUMO

Imaging phantoms are used to calibrate and validate the performance of magnetic resonance imaging (MRI) systems. Many new materials have been developed for additive manufacturing (three-dimensional [3D] printing) processes that may be useful in the direct printing or casting of dimensionally accurate, anatomically accurate, patient-specific, and/or biomimetic MRI phantoms. The T1, T2, and T2* spin relaxation times of polymer samples were tested to discover materials for use as tissue mimics and structures in MRI phantoms. This study included a cohort of polymer compounds that was tested in cured form. The cohort consisted of 101 standardized polymer samples fabricated from: two-part silicones and polyurethanes used in commercial casting processes; one-part optically cured polyurethanes used in 3D printing; and fused deposition thermoplastics used in 3D printing. The testing was performed at 3 T using inversion recovery, spin echo, and gradient echo sequences for T1, T2, and T2*, respectively. T1, T2, and T2* values were plotted with error bars to allow the reader to assess how well a polymer matches a tissue for a specific application. A correlation was performed between T1, T2, T2* values and material density, elongation, tensile strength, and hardness. Two silicones, SI_XP-643 and SI_P-45, may be usable mimics for reported liver values; one silicone, SI_XP-643, may be a useful mimic for muscle; one silicone, SI_XP-738, may be a useful mimic for white matter; and four silicones, SI_P-15, SI_GI-1000, SI_GI-1040, and SI_GI-1110, may be usable mimics for spinal cord. Elongation correlated to T2 (p = 0.0007), tensile strength correlated to T1 (p = 0.002), T2 (p = 0.0003), and T2* (p = 0.003). The 80 samples not providing measurable signal with T1, T2, T2* relaxation values too short to measure with the standard sequences, may be useful for MRI-invisible fixturing and medical devices at 3 T.

3.
J Nanosci Nanotechnol ; 11(9): 7653-64, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22097470

RESUMO

Magnetization dynamics and field dependent magnetization of different devices based on 25-30 nm thick Permalloy (Py) films: such as single Py layers (Py/MgO; Py/CoFeB/Al2O3) and Py inserted as a magnetic layer in magnetic tunnel junctions (Py/CoFe/Al2O3/CoFe; Py/CoFeB/Al2O3/CoFe; Py/MgO/Fe) have been extensively studied within a temperature range between 300 K down to 5 K. The dynamic response was investigated in the linear regime measuring the ferromagnetic resonance response of the Py layers using broadband vector network analyzer technique. Both the static and the dynamic properties suggest the possible presence of a thermally induced spin reorientation transition in the Py interface at temperatures around 60 K in all the samples investigated. It seems, however, that the details of the interface between Py and the hardening ferromagnet/insulator structure, the atomic structure of Py layers (amorphous vs. textured) as well as the presence of dipolar coupling through the insulating barrier in the magnetic tunnel junction structures could strongly influence this low temperature reorientation transition. Our conclusions are indirectly supported by structural characterization of the samples by means of X-Ray diffraction and high resolution transmission electron microscopy techniques. Micromagnetic simulations indicate the possibility of strongly enhanced surface anisotropy in thin Py films over CoFe or CoFeB underlayers. Comparison of the simulations with experimental results also shows that the thermally-induced spin reorientation transition could be influenced by the presence of strong disorder at the surface.

4.
Phys Rev Lett ; 97(8): 087206, 2006 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-17026331

RESUMO

We have investigated the interaction mechanism between two nanocontact spin transfer oscillators made on the same magnetic spin valve multilayer. The oscillators phase lock when their precession frequencies are made similar, and a giant magnetoresistance signal is detectable at one contact due to precession at the other. Cutting the magnetic mesa between the contacts with a focused-ion beam modifies the contact outputs, eliminates the phase locking, and strongly attenuates the magnetoresistance coupling, which indicates that spin waves rather than magnetic fields are the primary interaction mechanism.

5.
Phys Rev Lett ; 95(6): 067203, 2005 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-16090984

RESUMO

We have directly measured phase locking of spin transfer oscillators to an injected ac current. The oscillators lock to signals up to several hundred megahertz away from their natural oscillation frequencies, depending on the relative strength of the input. As the dc current varies over the locking range, time-domain measurements show that the phase of the spin transfer oscillations varies over a range of approximately +/-90 degrees relative to the input. This is in good agreement with general theoretical analysis of injection locking of nonlinear oscillators.

6.
Phys Rev Lett ; 92(2): 027201, 2004 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-14753964

RESUMO

We have directly measured coherent high-frequency magnetization dynamics in ferromagnetic films induced by a spin-polarized dc current. The precession frequency can be tuned over a range of several gigahertz by varying the applied current. The frequencies of excitation also vary with applied field, resulting in a microwave oscillator that can be tuned from below 5 to above 40 GHz. This novel method of inducing high-frequency dynamics yields oscillations having quality factors from 200 to 800. We compare our results with those from single-domain simulations of current-induced dynamics.

7.
J Electron Microsc Tech ; 8(3): 263-72, 1988 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-3246617

RESUMO

Thin films of the superconductive oxide YBa2Cu3O7-x have been made by electron-beam coevaporation of the metals in an oxygen atmosphere onto single-crystal [001]-oriented SrTiO3 and yttria-stabilized zirconia (YSZ) substrates. The oxide films were superconducting in the as-deposited state (Tc = 81-83K, Jc = 10(6) A/cm2 at 4.2K). Bright-field imaging, selected-area diffraction (SAD), and high-resolution imaging in the transmission electron microscope were used to characterize the microstructure of these films. All of the films were polycrystalline. On SrTiO3 the films were oriented, for the most part, with [110] parallel to the substrate surface. On YSZ, two microstructures were observed: one with smaller rectangular grains oriented with (100) or (010) parallel to the substrate surface and the other with (001) parallel to the surface (i.e., c-axis up).


Assuntos
Condutividade Elétrica , Metais/análise , Microscopia Eletrônica/métodos , Óxidos , Zircônio , Simulação por Computador , Cristalografia , Estrôncio , Titânio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA