Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Biomedicines ; 11(12)2023 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-38137347

RESUMO

Multiple sclerosis (MS) and Alzheimer's disease (AD) cause retinal thinning that is detectable in vivo using optical coherence tomography (OCT). To date, no papers have compared the two diseases in terms of the structural differences they produce in the retina. The purpose of this study is to analyse and compare the neuroretinal structure in MS patients, AD patients and healthy subjects using OCT. Spectral domain OCT was performed on 21 AD patients, 33 MS patients and 19 control subjects using the Posterior Pole protocol. The area under the receiver operating characteristic (AUROC) curve was used to analyse the differences between the cohorts in nine regions of the retinal nerve fibre layer (RNFL), ganglion cell layer (GCL), inner plexiform layer (IPL) and outer nuclear layer (ONL). The main differences between MS and AD are found in the ONL, in practically all the regions analysed (AUROCFOVEAL = 0.80, AUROCPARAFOVEAL = 0.85, AUROCPERIFOVEAL = 0.80, AUROC_PMB = 0.77, AUROCPARAMACULAR = 0.85, AUROCINFERO_NASAL = 0.75, AUROCINFERO_TEMPORAL = 0.83), and in the paramacular zone (AUROCPARAMACULAR = 0.75) and infero-temporal quadrant (AUROCINFERO_TEMPORAL = 0.80) of the GCL. In conclusion, our findings suggest that OCT data analysis could facilitate the differential diagnosis of MS and AD.

2.
Mult Scler Relat Disord ; 74: 104725, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37086637

RESUMO

BACKGROUND: Current procedures for diagnosing multiple sclerosis (MS) present a series of limitations, making it critically important to identify new biomarkers. The aim of the study was to identify new biomarkers for the early diagnosis of MS using spectral-domain optical coherence tomography (OCT) and artificial intelligence. METHODS: Spectral domain OCT was performed on 79 patients with relapsing-remitting multiple sclerosis (RRMS) (disease duration ≤ 2 years, no history of optic neuritis) and on 69 age-matched healthy controls using the posterior pole protocol that incorporates the anatomic Positioning System. Median retinal thickness values in both eyes and inter-eye difference in healthy controls and patients were evaluated by area under the receiver operating characteristic (AUROC) curve analysis in the foveal, parafoveal and perifoveal areas and in the overall area spanned by the three rings. The structures with the greatest discriminant capacity - retinal thickness and inter-eye difference - were used as inputs to a convolutional neural network to assess the diagnostic capability. RESULTS: Analysis of retinal thickness and inter-eye difference in RRMS patients revealed that greatest alteration occurred in the ganglion cell (GCL), inner plexiform (IPL), and inner retinal (IRL) layers. By using the average thickness of the GCL (AUROC = 0.82) and the inter-eye difference in the IPL (AUROC = 0.71) as inputs to a two-layer convolutional neural network, automatic diagnosis attained accuracy = 0.87, sensitivity = 0.82, and specificity = 0.92. CONCLUSION: This study adds weight to the argument that neuroretinal structure analysis could be incorporated into the diagnostic criteria for MS.


Assuntos
Esclerose Múltipla Recidivante-Remitente , Esclerose Múltipla , Humanos , Esclerose Múltipla/diagnóstico por imagem , Células Ganglionares da Retina , Inteligência Artificial , Tomografia de Coerência Óptica , Retina/diagnóstico por imagem , Esclerose Múltipla Recidivante-Remitente/diagnóstico por imagem
3.
Front Psychol ; 13: 827037, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36405220

RESUMO

Delusions are one of the most classical symptoms described in schizophrenia. However, despite delusions are often emotionally charged, they have been investigated using tasks involving non-affective material, such as the Beads task. In this study we compared 30 patients with schizophrenia experiencing delusions with 32 matched controls in their pattern of responses to two versions of the Beads task within a Bayesian framework. The two versions of the Beads task consisted of one emotional and one neutral, both with ratios of beads of 60:40 and 80:20, considered, respectively, as the "difficult" and "easy" variants of the task. Results indicate that patients showed a greater deviation from the normative model, especially in the 60:40 ratio, suggesting that more inaccurate probability estimations are more likely to occur under uncertainty conditions. Additionally, both patients and controls showed a greater deviation in the emotional version of the task, providing evidence of a reasoning bias modulated by the content of the stimuli. Finally, a positive correlation between patients' deviation and delusional symptomatology was found. Impairments in the 60:40 ratio with emotional content was related to the amount of disruption in life caused by delusions. These results contribute to the understanding of how cognitive mechanisms interact with characteristics of the task (i.e., ambiguity and content) in the context of delusional thinking. These findings might be used to inform improved intervention programs in the domain of inferential reasoning.

4.
J Pers Med ; 11(8)2021 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-34442447

RESUMO

BACKGROUND: The aim of this study is to explore an objective approach that aids the diagnosis of bipolar disorder (BD), based on optical coherence tomography (OCT) data which are analyzed using artificial intelligence. METHODS: Structural analyses of nine layers of the retina were analyzed in 17 type I BD patients and 42 controls, according to the areas defined by the Early Treatment Diabetic Retinopathy Study (ETDRS) chart. The most discriminating variables made up the feature vector of several automatic classifiers: Gaussian Naive Bayes, K-nearest neighbors and support vector machines. RESULTS: BD patients presented retinal thinning affecting most layers, compared to controls. The retinal thickness of the parafoveolar area showed a high capacity to discriminate BD subjects from healthy individuals, specifically for the ganglion cell (area under the curve (AUC) = 0.82) and internal plexiform (AUC = 0.83) layers. The best classifier showed an accuracy of 0.95 for classifying BD versus controls, using as variables of the feature vector the IPL (inner nasal region) and the INL (outer nasal and inner inferior regions) thickness. CONCLUSIONS: Our patients with BD present structural alterations in the retina, and artificial intelligence seem to be a useful tool in BD diagnosis, but larger studies are needed to confirm our findings.

5.
Sensors (Basel) ; 22(1)2021 Dec 27.
Artigo em Inglês | MEDLINE | ID: mdl-35009710

RESUMO

BACKGROUND: The aim of this paper is to implement a system to facilitate the diagnosis of multiple sclerosis (MS) in its initial stages. It does so using a convolutional neural network (CNN) to classify images captured with swept-source optical coherence tomography (SS-OCT). METHODS: SS-OCT images from 48 control subjects and 48 recently diagnosed MS patients have been used. These images show the thicknesses (45 × 60 points) of the following structures: complete retina, retinal nerve fiber layer, two ganglion cell layers (GCL+, GCL++) and choroid. The Cohen distance is used to identify the structures and the regions within them with greatest discriminant capacity. The original database of OCT images is augmented by a deep convolutional generative adversarial network to expand the CNN's training set. RESULTS: The retinal structures with greatest discriminant capacity are the GCL++ (44.99% of image points), complete retina (26.71%) and GCL+ (22.93%). Thresholding these images and using them as inputs to a CNN comprising two convolution modules and one classification module obtains sensitivity = specificity = 1.0. CONCLUSIONS: Feature pre-selection and the use of a convolutional neural network may be a promising, nonharmful, low-cost, easy-to-perform and effective means of assisting the early diagnosis of MS based on SS-OCT thickness data.


Assuntos
Esclerose Múltipla , Tomografia de Coerência Óptica , Diagnóstico Precoce , Humanos , Redes Neurais de Computação , Retina
7.
Sensors (Basel) ; 20(1)2019 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-31861282

RESUMO

As multiple sclerosis (MS) usually affects the visual pathway, visual electrophysiological tests can be used to diagnose it. The objective of this paper is to research methods for processing multifocal electroretinogram (mfERG) recordings to improve the capacity to diagnose MS. MfERG recordings from 15 early-stage MS patients without a history of optic neuritis and from 6 control subjects were examined. A normative database was built from the control subject signals. The mfERG recordings were filtered using empirical mode decomposition (EMD). The correlation with the signals in a normative database was used as the classification feature. Using EMD-based filtering and performance correlation, the mean area under the curve (AUC) value was 0.90. The greatest discriminant capacity was obtained in ring 4 and in the inferior nasal quadrant (AUC values of 0.96 and 0.94, respectively). Our results suggest that the combination of filtering mfERG recordings using EMD and calculating the correlation with a normative database would make mfERG waveform analysis applicable to assessment of multiple sclerosis in early-stage patients.


Assuntos
Eletrorretinografia/métodos , Esclerose Múltipla/diagnóstico , Área Sob a Curva , Biomarcadores , Análise Discriminante , Humanos , Curva ROC , Retina/fisiologia
8.
Psychiatry Res ; 270: 554-559, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30343241

RESUMO

Recent emotion recognition studies in schizophrenia have reported misattribution of emotional content to emotionally neutral faces. While in these studies faces are presented in the absence of any contextual reference, in daily life facial expressions are typically perceived within a specific situational context. However, there is no evidence on the possible modulatory role of contextual aids on emotion attribution to neutral faces. We address this issue in the present study. Thirty schizophrenia patients and thirty paired controls performed an emotion categorization task (by choosing one among six labels of emotions) with neutral target faces that were superimposed on affectively positive, negative or neutral scenes. In presence of positive contexts, patients categorized neutral faces as happy and fearful more frequently than controls. When negative contexts were present, patients also categorized neutral faces as fearful more frequently than controls. However, in the presence of neutral contexts patients and controls did not differ in their categorization pattern. These results suggest that explicit presence of a neutral context seems to compensate for the bias showed by patients. With the purpose of correcting emotion misattribution in schizophrenia, emotionally neutral contexts might be incorporated to treatments aimed at improving social cognition performance in this patient population.


Assuntos
Emoções , Reconhecimento Facial , Psicologia do Esquizofrênico , Percepção Social , Adulto , Medo , Feminino , Felicidade , Humanos , Masculino , Comportamento Social
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA