2.
Artigo em Inglês | MEDLINE | ID: mdl-38880999

RESUMO

Nowadays, the long-life management of patients with aortic stenosis has emerged as one of the most debated issues. Transcatheter aortic valve replacement is more frequently performed in younger patients with lower surgical risk, and also the number of valve-in-valve (ViV) procedures has increased in the last few years. However, coronary obstruction is the most dreadful complication related to this procedure. To prevent coronary obstruction in the context of transcatheter aortic ViV implantation, the BASILICA (bioprosthetic or native aortic scallop intentional laceration to prevent iatrogenic coronary artery obstruction) technique was developed. Although effective, BASILICA is complex and time-consuming. Hence, simpler, reproducible, and faster strategies are desirable. Here we present a promising simplified BASILICA technique employing an Armada Balloon to perform the leaflet laceration.

3.
JACC Case Rep ; 29(4): 102200, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38379644

RESUMO

Valve-in-ring procedures represent a feasible solution for high-risk patients with surgical repair failure. The risk of left ventricular outflow tract obstruction increases the challenge, and transcatheter approaches to prevent it are technically demanding and often do not resolve it. We demonstrate the feasibility and safety of a transseptal balloon-assisted translocation of the anterior mitral leaflet for valve-in-ring implantation.

4.
Int J Cardiol ; 389: 131236, 2023 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-37532153

RESUMO

BACKGROUND: Horizontal aorta (HA), defined by an aortic angulation (AA) ≥48°, is associated with worse outcomes particularly after self-expanding (SE) trans-catheter heart valve (THV) implantation. Although the SE ACURATE Neo THV demonstrated favorable procedural success rates in patients with HA, it remains associated with a non-negligible rate of moderate or greater paravalvular leak (PVL). OBJECTIVES: Aim of the study was to assess the performance of ACURATE Neo2 in the setting of HA. METHODS: We performed a multicenter cohort analysis on patients with severe aortic valve stenosis and HA undergoing transcatheter aortic valve replacement (TAVR) with the Neo or Neo2 THV enrolled in the ITAL-neo registry. The primary endpoint was a composite of early safety and clinical efficacy at 30 days according to the Valve Academic Research Consortium-3 (VARC-3). Secondary endpoints included the occurrence of moderate or severe PVL and 90-day clinical outcomes. RESULTS: Among 900 patients included in the ITAL-neo registry, 407 exhibited HA; of these, 300 received a Neo THV and 107 a Neo2 THV. HA, irrespective of the THV implanted, emerged as an independent risk factor for developing ≥ moderate PVL. Technical and device success at 30-day follow-up was comparable between groups. However, Neo2 was associated with a significantly lower rate of ≥moderate PVL vs. Neo: (5% vs. 15%; p < 0.001), which was confirmed also at 90-day follow-up. Additionally, no correlation was found between ≥moderate PVL and AA in the Neo2 group, while PVL degree increased proportionally to the AA in the Neo cohort. CONCLUSION: In patients with HA, the new generation Acurate Neo2 THV was associated with a comparable device success rate and a significantly lower rate of ≥moderate PVL, when compared with its predecessor.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Desenho de Prótese , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Sistema de Registros
5.
JACC cardiovasc. interv ; (23): (23)00846-4, jul.2023. ilus
Artigo em Inglês | Sec. Est. Saúde SP, CONASS, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1444382

RESUMO

OBJECTIVES: The authors sought to evaluate the incidence, predictors, and outcomes of new permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement (TAVR) with contemporary self-expanding valves (SEV). BACKGROUND: Need for PPI is frequent post-TAVR, but conflicting data exist on new-generation SEV and on the prognostic impact of PPI. METHODS: This study included 3,211 patients enrolled in the multicenter NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) and NEOPRO-2 (A Multicenter Comparison of ACURATE NEO2 Versus Evolut PRO/PRO+ Transcatheter Heart Valves 2) registries (January 2012 to December 2021) who underwent transfemoral TAVR with SEV. Implanted transcatheter heart valves (THV) were Acurate neo (n = 1,090), Acurate neo2 (n = 665), Evolut PRO (n = 1,312), and Evolut PRO+ (n = 144). Incidence and predictors of new PPI and 1-year outcomes were evaluated. RESULTS: New PPI was needed in 362 patients (11.3%) within 30 days after TAVR (8.8%, 7.7%, 15.2%, and 10.4%, respectively, after Acurate neo, Acurate neo2, Evolut PRO, and Evolut PRO+). Independent predictors of new PPI were Society of Thoracic Surgeons Predicted Risk of Mortality score, baseline right bundle branch block and depth of THV implantation, both in patients treated with Acurate neo/neo2 and in those treated with Evolut PRO/PRO+. Predischarge reduction in ejection fraction (EF) was more frequent in patients requiring PPI (P = 0.014). New PPI was associated with higher 1-year mortality (16.9% vs 10.8%; adjusted HR: 1.66; 95% CI: 1.13-2.43; P = 0.010), particularly in patients with baseline EF <40% (P for interaction = 0.049). CONCLUSIONS: New PPI was frequently needed after TAVR with SEV (11.3%) and was associated with higher 1-year mortality, particularly in patients with EF <40%. Baseline right bundle branch block and depth of THV implantation independently predicted the need of PPI.


Assuntos
Marca-Passo Artificial
7.
Thorac Cardiovasc Surg ; 71(6): 462-468, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-36736367

RESUMO

OBJECTIVES: The aim of the present study was to evaluate the results of isolated coronary artery bypass grafting (CABG) with or without revascularization of the occluded right coronary artery (RCA). METHODS: Patients undergoing isolated CABG were included in a prospective European multicenter registry. Outcomes were adjusted for imbalance in preoperative variables with propensity score matching analysis. Late outcomes were evaluated with Kaplan-Meier's method and competing risk analysis. RESULTS: Out of 2,948 included in this registry, 724 patients had a total occlusion of the RCA and were the subjects of this analysis. Occluded RCA was not revascularized in 251 (34.7%) patients with significant variability between centers. Among 245 propensity score-matched pairs, patients with and without revascularization of occluded RCA had similar early outcomes. The nonrevascularized RCA group had increased rates of 5-year all-cause mortality (17.7 vs. 11.7%, p = 0.039) compared with patients who had their RCA revascularized. The rates of myocardial infarction and repeat revascularization were only numerically increased but contributed to a significantly higher rate of MACCE (24.7 vs. 15.7%, p = 0.020) at 5 year among patients with nonrevascularized RCA. CONCLUSION: In this multicenter study, one-third of totally occluded RCAs was not revascularized during isolated CABG for multivessel coronary artery disease. Failure to revascularize an occluded RCA in these patients increased the risk of all-cause mortality and MACCEs at 5 years.


Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Humanos , Estudos Prospectivos , Resultado do Tratamento , Ponte de Artéria Coronária , Doença da Artéria Coronariana/cirurgia
8.
Circ Cardiovasc Interv ; 16(1): e012538, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36649387

RESUMO

BACKGROUND: In recent years, transcatheter aortic valve replacement (TAVR) techniques and technology have continuously improved. Data regarding the impact of these advancements on outcomes in large real-world settings are still limited. The aim of this study was to investigate temporal trends and assess contemporary outcomes after TAVR with Evolut PRO/PRO+ supra-annular self-expanding valves. METHODS: This study included patients enrolled in the multicenter NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) and NEOPRO-2 (A Multicenter Comparison of ACURATE NEO2 Versus Evolut PRO/PRO+ Transcatheter Heart Valves 2) registries who underwent transfemoral TAVR with Evolut PRO/PRO+. Procedural dates (August 2017 through November 2021) were stratified in quartiles (Q) and used to investigate temporal trends in TAVR outcomes. Predischarge, 30-day Valve Academic Research Consortium-3 defined, and 1-year outcomes were evaluated. RESULTS: In total, 1616 patients from 28 centers were included. Over time, patients had lower Society of Thoracic Surgeon-Predicted Risk of Mortality score (Q1-4, 4.1% [2.8-6.3%], 3.7% [2.6-5.3%], 3.3% [2.4-4.9%], 2.9% [2.2-4.3%]; P<0.001) and more moderate or heavy valve calcification (Q1-4, 80%, 80%, 82%, 88%; P=0.038). Overall Valve Academic Research Consortium-3 technical success was 94.1%, with 30-day and 1-year all-cause mortality of 2.4% and 10%, respectively. Throughout the study period, procedures were associated with higher rates of 30-day device success (Q1-4, 81.2%, 82.2%, 82.0%, 88.0%; Cochran-Armitage P=0.023) and early safety (Q1-4, 66.8%, 67.5%, 74.0%, 77.6%; Cochran-Armitage P<0.001), with fewer permanent pacemaker implantations (Q1-4: 15.3%, 20.0%, 12.1%, 11.6%; Cochran-Armitage P=0.023) and residual mild or greater paravalvular leaks (Q1-4, 50.4%, 42.1%, 36.5%, 35.8%; Cochran-Armitage P<0.001). CONCLUSIONS: TAVR with Evolut PRO/PRO+ self-expanding valve is safe and effective. Despite the treatment of heavier calcified anatomies, procedural outcomes are improving over time with less need for pacemaker implantation and less significant paravalvular leaks.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Fatores de Tempo , Resultado do Tratamento , Sistema de Registros , Desenho de Prótese , Fatores de Risco
9.
EuroIntervention ; 18(12): 977-986, 2023 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-36093795

RESUMO

BACKGROUND: The ACURATE neo2 (NEO2) and Evolut PRO/PRO+ (PRO) bioprostheses are new-generation self-expanding valves developed for transcatheter aortic valve replacement (TAVR). AIMS: We sought to compare the performance of the ACURATE neo2 and Evolut PRO/PRO+ devices. METHODS: The NEOPRO-2 registry retrospectively included patients who underwent TAVR for severe aortic stenosis with either the NEO2 or PRO devices between August 2017 and December 2021 at 20 centres. In-hospital and 30-day Valve Academic Research Consortium (VARC)-3 defined outcomes were evaluated. Propensity score (PS) matching and binary logistic regression were performed to adjust the treatment effect for PS quintiles. A subgroup analysis assessed the impact of aortic valve calcification. RESULTS: A total of 2,175 patients (NEO2: n=763; PRO: n=1,412) were included. The mean age was 82±6.2 years and the mean Society of Thoracic Surgeons score was 4.2%. Periprocedural complications were low, and both groups achieved high rates of technical success (93.1% vs 94.1%; p=0.361) and predischarge intended valve performance (96.0% vs 94.1%; p=0.056), both in the unmatched and matched analysis (452 pairs). Device success at 30 days was comparable (84.3% vs 83.6%; p=0.688), regardless of aortic valve calcification severity (p>0.05 for interaction). A suggestion for higher VARC-3 early safety in the NEO2 group was mainly driven by reduced rates of new permanent pacemaker implantation (7.7% vs 15.6%; p<0.001). CONCLUSIONS: This retrospective analysis reports a similar short-term performance of the ACURATE neo2 platform compared with the new-generation Evolut PRO/PRO+ devices. Randomised studies are needed to confirm our exploratory findings.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Humanos , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Próteses Valvulares Cardíacas/efeitos adversos , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
10.
Int J Cardiol ; 371: 116-120, 2023 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-36108764

RESUMO

OBJECTIVES: The role of the underlying etiology in isolated tricuspid valve surgery has not been investigated extensively in current literature. Aim of this study was to analyse outcomes of patients undergoing surgery due to endocarditis compared to other pathologies. METHODS: The SURTRI study is a multicenter study enrolling adult patients who underwent isolated tricuspid valve surgery (n = 406, 55 ± 16 y.o.; 56% female) at 13 international sites. Propensity weighted analysis was performed to compare groups (IE group n = 107 vs Not-IE group n = 299). RESULTS: No difference was found regarding the 30-day mortality (Group IE: 2.8% vs Group Not-IE = 6.8%; OR = 0.45) and major adverse events. Weighted cumulative incidence of cardiac death was significantly higher for patients with endocarditis (p = 0.01). The composite endpoint of cardiac death and reoperation at 6 years was reduced in the Group IE (63.2 ± 6.8% vs 78.9 ± 3.1%; p = 0.022). Repair strategy resulted in an increased late survival even in IE cases. CONCLUSIONS: Data from SURTRI study report acceptable 30-day results but significantly reduced late survival in the setting of endocarditis of the tricuspid valve. Multi-disciplinary approach, repair strategy and earlier treatment may improve outcomes.


Assuntos
Endocardite , Implante de Prótese de Valva Cardíaca , Adulto , Humanos , Feminino , Masculino , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Prognóstico , Resultado do Tratamento , Endocardite/diagnóstico , Endocardite/cirurgia , Endocardite/etiologia , Reoperação , Morte , Implante de Prótese de Valva Cardíaca/métodos , Estudos Retrospectivos
11.
J Clin Med ; 11(19)2022 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-36233623

RESUMO

OBJECTIVES: The aim of the present study was to evaluate the risk of late mortality and major adverse cardiovascular and cerebral events after coronary artery bypass grafting (CABG) in patients with prior percutaneous coronary intervention (PCI). METHODS: A total of 2948 patients undergoing isolated CABGs were included in a prospective multicenter registry. Outcomes were adjusted for multiple covariates in logistic regression, Cox proportional hazards analysis and competing risk analysis. RESULTS: In all, 2619 patients fulfilled the inclusion criteria of this analysis. Of them, 2199 (79.1%) had no history of PCI and 420 (20.9%) had a prior PCI. An adjusted analysis showed that a single prior PCI and multiple prior PCIs did not increase the risk of 30-day and 5-year mortality. Patients with multiple prior PCIs had a significantly higher risk of 5-year myocardial infarction (SHR 2.566, 95%CI 1.379-4.312) and repeat revascularization (SHR 1.774, 95%CI 1.140-2.763). Similarly, 30-day and 5-year mortality were not significantly increased in patients with prior PCI treatment of single or multiple vessels. Patients with multiple vessels treated with PCI had a significantly higher risk of 5-year myocardial infarction (SHR 2.640, 95%CI 1.497-4.658), repeat revascularization (SHR 1.648, 95%CI 1.029-2.638) and stroke (SHR 2.215, 95%CI 1.056-4.646) at 5-year. The risk for repeat revascularization was also increased with a prior single vessel PCI, but not for other outcomes. CONCLUSIONS: Among patients undergoing CABGs, multiple prior PCIs seem to increase the risk of late myocardial infarction and the need for repeat revascularization, but not the risk of mortality.

12.
J Pers Med ; 12(7)2022 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-35887554

RESUMO

Background: Data to support the routine use of embolic protection devices for stroke prevention during transcatheter aortic valve replacement (TAVR) are controversial. Identifying patients at high risk for peri-procedural cerebrovascular events may facilitate effective patient selection for embolic protection devices during TAVR. Aim: To generate a risk score model for stratifying TAVR patients according to peri-procedural cerebrovascular events risk. Methods and results: A total of 8779 TAVR patients from 12 centers worldwide were included. Peri-procedural cerebrovascular events were defined as an ischemic stroke or a transient ischemic attack occurring ≤24 h from TAVR. The peri-procedural cerebrovascular events rate was 1.4% (n = 127), which was independently associated with 1-year mortality (hazards ratio (HR) 1.78, 95% confidence interval (CI) 1.06−2.98, p < 0.028). The TASK risk score parameters were history of stroke, use of a non-balloon expandable valve, chronic kidney disease, and peripheral vascular disease, and each parameter was assigned one point. Each one-point increment was associated with a significant increase in peri-procedural cerebrovascular events risk (OR 1.96, 95% CI 1.56−2.45, p < 0.001). The TASK score was dichotomized into very-low, low, intermediate, and high (0, 1, 2, 3−4 points, respectively). The high-risk TASK score group (OR 5.4, 95% CI 2.06−14.16, p = 0.001) was associated with a significantly higher risk of peri-procedural cerebrovascular events compared with the low TASK score group. Conclusions: The proposed novel TASK risk score may assist in the pre-procedural risk stratification of TAVR patients for peri-procedural cerebrovascular events.

13.
JACC Cardiovasc Interv ; 15(11): 1101-1110, 2022 06 13.
Artigo em Inglês | MEDLINE | ID: mdl-35595675

RESUMO

BACKGROUND: The first-generation ACURATE neo transcatheter heart valve (THV) (Boston Scientific) was associated with a non-negligible occurrence of moderate or greater paravalvular aortic regurgitation (AR) following transcatheter aortic valve replacement. To overcome this issue, the ACURATE neo2 iteration, which incorporates a taller outer skirt aimed at reducing the occurrence of paravalvular AR, has recently been developed. OBJECTIVES: The aim of this study was to assess the efficacy and safety of the ACURATE neo2 (Boston Scientific) THV in patients with severe aortic valve stenosis. METHODS: ITAL-neo was an observational, retrospective, multicenter registry enrolling consecutive patients with severe aortic valve stenosis, treated with first- and second-generation ACURATE neo THVs, via transfemoral and trans-subclavian access, in 13 Italian centers. One-to-one propensity score matching was applied to account for baseline characteristics unbalance. The primary endpoint was the occurrence of moderate or greater paravalvular AR on predischarge echocardiographic assessment. Secondary endpoints included postprocedural technical success and 90-day device success and safety. RESULTS: Among 900 patients included in the registry, 220 received the ACURATE neo2 THV, whereas 680 were treated with the first-generation device. A total of 410 patients were compared after 1:1 propensity score matching. The ACURATE neo2 THV was associated with a 3-fold lower frequency of postprocedural moderate or greater paravalvular AR (11.2% vs 3.5%; P < 0.001). No other hemodynamic differences were observed. Postprocedural technical success was similar between the 2 cohorts. Fewer adverse events were observed in patients treated with the ACURATE neo2 at 90 days. CONCLUSIONS: Transfemoral transcatheter aortic valve replacement using the ACURATE neo2 was associated with a significant lower frequency of moderate or greater paravalvular AR compared with the earlier generation ACURATE neo device, with encouraging short-term safety and efficacy.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Hemodinâmica , Humanos , Desenho de Prótese , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
14.
Eur J Cardiothorac Surg ; 62(3)2022 08 03.
Artigo em Inglês | MEDLINE | ID: mdl-35448903

RESUMO

OBJECTIVES: The interest in isolated tricuspid valve disease has rapidly increased recently. However, clinical trials and registry data are rare in the surgical literature. This study aimed to describe the early and long-term outcomes of a real-world experience in isolated tricuspid procedures comparing repair and replacement strategies. METHODS: The Surgical-Tricuspid study is a multicentre retrospective study that enrolled adult patients who had undergone isolated tricuspid valve surgery at 13 international sites. Propensity score-matched analysis was used to compare repair versus replacement. RESULTS: A cohort of 426 patients was enrolled [mean age: 55 (16) years; 56% female]. After matching, 175 comparable pairs were analysed. Preoperative left ventricular ejection fraction was 55(9) vs 56(9) (P = 0.8) while moderate-severe tricuspid regurgitation was present in 95% of cases. The 30-day mortality rate was 4.0% vs 8.0% in the repair and replacement groups, respectively (P = 0.115). The rates of re-exploration for bleeding (6.9% vs 13.1% P = 0.050), permanent pacemaker implantation (5.1% vs 12.0%; P = 0.022) and blood transfusion (46% vs 62%; P = 0.002) were higher in the replacement group. Cumulative survival rates at 3, 5 and 7 years in the repair group were 84 (3)%, 75 (4)% and 56 (9)% vs 71 (4)%, 66 (5)% and 58 (5)% in the replacement group (P = 0.001) while cumulative incidence for reoperation at 10 years did not differ between groups [repair 10 (1)% vs replacement 9 (1)%; P = 0.469]. CONCLUSIONS: The data from the Surgical-Tricuspid study reported a high risk for patients undergoing tricuspid surgery. Isolated valve repair offered reduced early and late mortality with no difference regarding reoperation rate when compared with replacement.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Adulto , Feminino , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Volume Sistólico , Resultado do Tratamento , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/etiologia , Função Ventricular Esquerda
15.
J Card Surg ; 37(7): 1959-1966, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35385588

RESUMO

BACKGROUND: Aim of this study is to analyse the performances of Clinical Risk Score (CRS) and European System for Cardiac Operative Risk Evaluation (EuroSCORE)-II in isolated tricuspid surgery. METHODS: Three hundred and eighty-three patients (54 ± 16 year; 54% female) were enrolled. Receiver operating characteristic analysis was performed to evaluate the relationship between the true positive fraction of test results and the false-positive fraction for a procedure. RESULTS: Considering the 30-day mortality the area under the curve was 0.6 (95% confidence interval [CI] 0.50-0.72) for EuroSCORE II and 0.7 (95% CI 0.56-0.84) for CRS-score. The ratio of expected/observed mortality showed underestimation when considering EuroSCORE-II (min. 0.46-max. 0.6). At multivariate analysis, the CRS score (p = .005) was predictor of late cardiac death. CONCLUSION: We suggest using both scores to obtain a range of expected mortality. CRS to speculate on late survival.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Valva Tricúspide , Feminino , Mortalidade Hospitalar , Humanos , Masculino , Curva ROC , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Valva Tricúspide/cirurgia
16.
J Card Surg ; 37(5): 1250-1253, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35182401

RESUMO

Mitral valve repair (MVR) is undisputedly associated with better clinical and functional outcomes than any other type of valve substitute. Conventional mitral valve surgery in dedicated high-volume centers can assure excellent results in terms of mortality and freedom from mitral regurgitation (MR) recurrence but requires cardiopulmonary bypass (CPB) and cardioplegic heart arrest. Trying to replicate the percentage of success of surgical MVR is the aim of all new transcatheter mitral dedicated devices. In particular, transapical beating-heart mitral valve repair by artificial chordae implantation with transesophageal echocardiography guidance is an expanding field. The safety and feasibility of the procedure have already been largely demonstrated with Neochord and more recently with Harpoon systems. Wang et al. present the outcomes of the first-in-human experience using a novel artificial chordae implantation device, the Mitralstitch system. Despite a quite small cohort of only 10 patients treated, 1-year results are satisfying and comparable with the early experience with former devices (4 patients with moderate or more MR recurrence). The comparison with surgical MVR is still unfavorable and requires further studies and significant procedure improvement. However, the device permits the treatment of anterior and posterior leaflets prolapse and performs quite easily edge-to-edge reparation. It will be interesting to evaluate longer follow-up in larger cohorts of patients as well as the possibility to shift to the transfemoral approach.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Cordas Tendinosas/cirurgia , Ecocardiografia Transesofagiana/métodos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Insuficiência da Valva Mitral/etiologia , Resultado do Tratamento
17.
Ann Thorac Surg ; 113(2): 585-592, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33831392

RESUMO

BACKGROUND: Isolated tricuspid valve (TV) surgery is a rare procedure generally considered at high risk for perioperative mortality and poor long-term outcomes. Surgical treatment can be performed with either an arrested heart (AH) or beating heart (BH) technique. The aim of this study was to compare the outcomes of isolated tricuspid surgery with 2 different approaches. METHODS: The Surgical-Tricuspid Study is a multicenter international retrospective study enrolling adult patients who underwent isolated TV procedures (n = 406; age 56 ± 16 years; 56% female) at 13 international sites. The AH and BH strategies were performed in 253 and 153 patients, respectively. Propensity score-matched analysis was used to compare groups. RESULTS: After matching, 129 pairs were obtained and analyzed. The 30-day mortality rate was 6.2% versus 5.0% in the AH and BH groups, respectively (P = .9). The rates of acute renal failure requiring replacement therapy (10% versus 3%; P = .02) and stroke (1.6% versus 0%; P = .08) were numerically higher in the AH group. The 6-year survival rate was 67% ± 6% versus 78% ± 5% in the AH and BH groups, respectively (P = .18), whereas freedom from cardiac death was 75% ± 5% versus 84% ± 4% (P = .21). The 6-year composite cardiac end point of cardiac death and reoperation rate was 60% ± 9% versus 86% ± 5% (P = .024) comparing AH-TV replacement and BH-TV repair groups. CONCLUSIONS: Isolated TV surgery performed with a BH strategy is a safe option and resulted in a trend of increased long-term survival and freedom from reoperation compared with the standard AH technique. Patients undergoing BH valve repair had the best long-term outcome.


Assuntos
Parada Cardíaca Induzida/métodos , Implante de Prótese de Valva Cardíaca/métodos , Complicações Pós-Operatórias/epidemiologia , Pontuação de Propensão , Insuficiência da Valva Tricúspide/cirurgia , Valva Tricúspide/cirurgia , Europa (Continente)/epidemiologia , Feminino , Seguimentos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Reoperação , Estudos Retrospectivos , Fatores de Risco , Taxa de Sobrevida/tendências , Fatores de Tempo
18.
Heart Lung Circ ; 31(2): 263-271, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34330630

RESUMO

BACKGROUND: Postoperative bleeding after cardiac surgery is associated with increased morbidity and mortality. We tested the hypothesis that patients with a preoperatively estimated high risk of severe perioperative bleeding may have impaired early outcome after on-pump versus off-pump coronary artery bypass grafting (CABG). METHOD: Data from 7,352 consecutive patients who underwent isolated CABG from January 2015 to May 2017 were included in the multicentre European Coronary Artery Bypass Grafting registry. The postoperative bleeding risk was estimated using the WILL-BLEED risk score. Of all included patients, 3,548 had an increased risk of severe perioperative bleeding (defined as a WILL-BLEED score ≥4) and were the subjects of this analysis. We compared the early outcomes between patients who underwent on-pump or off-pump CABG using a multivariate mixed model for risk-adjusted analysis. RESULTS: Off-pump surgery was performed in 721 patients (20.3%). On-pump patients received more packed red blood cell units (on-pump: 1.41 [95% confidence interval {CI} 0.99-1.86]; off-pump: 0.86 [95% CI 0.64-1.08]; p<0.001), had a longer stay in the intensive care unit (on-pump: 4.4 [95% CI 3.6-8.1] days; off-pump: 3.2 [95% CI 2.0-4.4] days; p=0.049), and a higher rate of postoperative atrial fibrillation (on-pump: 46.5% [95% CI 34.9-58.1]; off-pump: 31.3% [95% CI 21.7-40.9]; p=0.025). Furthermore, on-pump patients showed a trend towards a higher rate of postoperative stroke (on-pump: 2.4% [95% CI 0.9-4.1]; off-pump: 1.1 [95% CI 0.2-2.7]; p=0.094). CONCLUSION: Our data suggest that in patients with an increased risk of bleeding, the use of cardiopulmonary bypass is associated with higher morbidity. These patients may benefit from off-pump surgery if complete revascularisation can be ensured.


Assuntos
Fibrilação Atrial , Ponte de Artéria Coronária sem Circulação Extracorpórea , Ponte Cardiopulmonar , Ponte de Artéria Coronária/efeitos adversos , Ponte de Artéria Coronária sem Circulação Extracorpórea/efeitos adversos , Humanos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Resultado do Tratamento
19.
Cardiovasc Revasc Med ; 40S: 139-143, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-34362686

RESUMO

Preserving coronary artery access is a crucial goal during transcatheter aortic valve replacement (TAVR) procedures, especially in case of self-expandable transcatheter heart valve (SE-THV) implantation. In this light, a proper commissural alignment is needed to avoid the risk of coronary obstruction and to permit easy vessels re-cannulation for diagnostic and interventional purposes. New-generation SE-THVs have been furnished of different markers, able to guide operators to perform a correct commissural alignment. In this case series, we describe key procedural aspects of commissural alignment for the different available SE-THVs, providing a step-by-step tutorial for each device. Lastly, we illustrate a commissural alignment in a contrast-zero TAVR.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
20.
J Cardiovasc Surg (Torino) ; 63(2): 212-221, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34825795

RESUMO

BACKGROUND: The aims of this study were: to present the clinical and pathological characteristics of cardiac tumors in a single-center series of patients; to describe the association of imaging characteristics, clinical presentation and surgical treatment; to analyze if second level imaging tests, computed tomography (CT) and cardiac magnetic resonance (CMR); and to improve the diagnostic accuracy when compared to first-line imaging technique (transthoracic echocardiography [TTE]). METHODS: We reviewed the medical and surgical records, TTE, CT and CMR examinations of 86 patients with a histological diagnosis of cardiac tumors between 2004 and 2019. RESULTS: The majority were benign tumors (81%) with myxoma accounting for 66% of cases. Among malignancies, metastasis (8%) and primary tumors (10%) were equally recognized. Symptoms at presentation (45% of patients) were associated to larger diameters at TTE. Malignancies were larger (mean diameter 37±14 mm vs. 27±13 mm, P<0.01), more frequently exhibited irregular shape (67% vs. 17%, P<0.01), frayed or polylobulated surface (73% vs. 38%, P=0.035), heterogeneous aspect (67% vs. 32%, P=0.012). A maximum diameter >28 mm and a minimum diameter >19.5 mm emerged as possible cut-off values for the differentiation of benign and malignant tumors. The ability of TTE, CT and CMR features in identifying malignancies was moderate (diagnostic accuracy of 84%, 81%, 76% respectively). The mean survival time after surgery was 1.6±1.4 years in malignancies and 6.8±4.7 years in benign tumors. CONCLUSIONS: Cardiac tumors are rare and mostly benign; their nature and clinics related to TTE appearance. CT and CMR may be used synergically with TTE. Surgery is curative in benign tumors, survival remains scarce in malignancies.


Assuntos
Neoplasias Cardíacas , Ecocardiografia/métodos , Neoplasias Cardíacas/diagnóstico por imagem , Neoplasias Cardíacas/cirurgia , Humanos , Imageamento por Ressonância Magnética/métodos , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA