Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Magn Reson Med ; 91(6): 2546-2558, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38376096

RESUMO

PURPOSE: We aimed to develop a free-breathing (FB) cardiac DTI (cDTI) method based on short-axis PROPELLER (SAP) and M2 motion compensated spin-echo EPI (SAP-M2-EPI) to mitigate geometric distortion and eliminate aliasing in acquired diffusion-weighted (DW) images, particularly in patients with a higher body mass index (BMI). THEORY AND METHODS: The study involved 10 healthy volunteers whose BMI values fell into specific categories: BMI <25 (4 volunteers), 25< BMI <28 (5 volunteers), and BMI >30 (1 volunteer). We compared DTI parameters, including fractional anisotropy (FA), mean diffusivity (MD), and helix angle transmurality (HAT), between SAP-M2-EPI and M2-ssEPI. To evaluate the performance of SAP-M2-EPI in reducing geometric distortions in the left ventricle (LV) compared to CINE and M2-ssEPI, we utilized the DICE similarity coefficient (DSC) and assessed misregistration area. RESULTS: In all volunteers, SAP-M2-EPI yielded high-quality LV DWIs without aliasing, demonstrating significantly reduced geometric distortion (with an average DSC of 0.92 and average misregistration area of 90 mm2) and diminished signal loss due to bulk motion when compared to M2-ssEPI. DTI parameter maps exhibited consistent patterns across slices without motion related artifacts. CONCLUSION: SAP-M2-EPI facilitates free-breathing cDTI of the entire LV, effectively eliminating aliasing and minimizing geometric distortion compared to M2-ssEPI. Furthermore, it preserves accurate quantification of myocardial microstructure.


Assuntos
Imagem de Difusão por Ressonância Magnética , Imagem de Tensor de Difusão , Humanos , Estudos de Viabilidade , Imagem de Tensor de Difusão/métodos , Imagem de Difusão por Ressonância Magnética/métodos , Coração/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Imagem Ecoplanar/métodos
2.
Magn Reson Med ; 89(3): 990-1001, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36300861

RESUMO

PURPOSE: The noninvasive measurement of biological tissue elasticity is an evolving technology that enables the robust characterization of soft tissue mechanics for a wide array of biomedical engineering and clinical applications. We propose, design, and implement here a new MRI technique termed asynchronous magnetic resonance elastography (aMRE) that pushes the measurement technology toward a driverless implementation. This technique can be added to clinical MRI scanners without any additional specialized hardware. THEORY: Asynchronous MRE is founded on the theory of diffuse wavefields and noise correlation previously developed in ultrasound to reconstruct shear wave speeds using seemingly incoherent wavefields. Unlike conventional elastography methods that solve an inverse problem, aMRE directly reconstructs a pixel-wise mapping of wave speed using the spatial-temporal statistics of the measured wavefield. METHODS: Incoherent finger tapping served as the wave-generating source for all aMRE measurements. Asynchronous MRE was performed on a phantom using a Siemens Prismafit as an experimental validation of the theory. It was further performed on thigh muscles as a proof-of-concept implementation of in vivo imaging using a Siemens Skyra scanner. RESULTS: Numerical and phantom experiments show an accurate reconstruction of wave speeds from seemingly noisy wavefields. The proof-of-concept thigh experiments also show that the aMRE protocol can reconstruct a pixel-wise mapping of wave speeds. CONCLUSION: Asynchronous MRE is shown to accurately reconstruct shear wave speeds in phantom experiments and remains at the proof-of-concept stage for in vivo imaging. After further validation and improvements, it has the potential to lower both the technical and monetary barriers of entry to measuring tissue elasticity.


Assuntos
Técnicas de Imagem por Elasticidade , Técnicas de Imagem por Elasticidade/métodos , Ultrassonografia , Elasticidade , Imagens de Fantasmas , Imageamento por Ressonância Magnética/métodos
3.
J Magn Reson ; 333: 107098, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34794090

RESUMO

Magnetic Resonance Current Density Imaging (MRCDI) is an imaging modality providing cross-sectional current density (J¯) information inside the body. The clinical applicability of MRCDI is highly dependent on the sensitivity of the acquired noisy current-induced magnetic flux density (B∼z) distributions. Here, a novel analysis is developed to investigate the combined effect of relevant parameters of the RF spoiled gradient echo (FLASH) pulse sequence on the SNR level and the total acquisition time (TAT) of the acquired B∼z images. The proposed analysis then is expanded for a multi-echo FLASH (ME-FLASH) pulse sequence to take advantage of combining the multiple echoes to achieve B∼zcomb distribution with a higher SNR than the one achievable with a single echo acquisition. The optimized sequence parameters to acquire a B∼z distribution with the highest possible SNR for a given acquisition time or the desired SNR in the shortest scan time are estimated using the proposed analysis. The analysis also provides different sets of sequence parameters to acquire B∼z distributions with the same SNR at almost the same TAT. Furthermore, the effects of intensive utilization of the gradients and the magnetohydrodynamic (MHD) flow velocity on the acquired B∼z distribution in MRCDI experiments is investigated. The analytical results of the proposed analysis are validated experimentally using an imaging phantom having the conductivity and the relaxation parameters of the brain white matter tissue.

4.
Phys Med Biol ; 66(5): 055011, 2021 02 20.
Artigo em Inglês | MEDLINE | ID: mdl-33472190

RESUMO

Diffusion tensor-magnetic resonance electrical impedance tomography (DT-MREIT) is an imaging modality to obtain low-frequency anisotropic conductivity distribution employing diffusion tensor imaging and MREIT techniques. DT-MREIT is based on the linear relationship between the conductivity and water self-diffusion tensors in a porous medium, like the brain white matter. Several DT-MREIT studies in the literature provide cross-sectional anisotropic conductivity images of tissue phantoms, canine brain, and the human brain. In these studies, the conductivity tensor images are reconstructed using the diffusion tensor and current density data acquired by injecting two linearly independent current patterns. In this study, a novel reconstruction algorithm is devised for DT-MREIT to reconstruct the conductivity tensor images using a single current injection. Therefore, the clinical applicability of DT-MREIT can be improved by reducing the total acquisition time, the number of current injection cables, and contact electrodes to half by decreasing the number of current injection patterns to one. The proposed method is evaluated utilizing simulated measurements and physical experiments. The results obtained show the successful reconstruction of the anisotropic conductivity distribution using the proposed single current DT-MREIT.


Assuntos
Algoritmos , Encéfalo/diagnóstico por imagem , Imagem de Tensor de Difusão/métodos , Impedância Elétrica , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Animais , Anisotropia , Estudos Transversais , Cães , Humanos
5.
J Magn Reson ; 303: 128-137, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-31063921

RESUMO

In this study, a method is proposed to image magnetohydrodynamic (MHD) flow of ionic solutions, which is caused by externally injected electrical current to an imaging media, during MRI scans. A multi-physics (MP) model is created by using the electrical current, laminar flow, and MR equations. The conventional spoiled gradient echo MRI pulse sequence with bipolar flow encoding gradients is utilized to encode the MHD flow. Using the MP model and the MRI pulse sequence, relationship between the MHD flow related phase in the acquired MR signal, the injection current, and the MRI pulse sequence parameters is stated. Numerical simulations and physical experiments are performed to validate the proposed method. The simulation and experimental results are in agreement and show that the MHD flow related MR phase depends on the amplitude and duration of the flow encoding gradient and the injected current. This method may be used to evaluate the MHD flow of conductive liquid media during MRI scans with simultaneous electrical current injections. The MHD flow related MR phase is 1.5 radian for an injected current of 1 mA amplitude, 30 ms duration and a flow encoding gradient amplitude of 24 mT/m. This large MR phase range exhibits potential use of this method for clinical applications such as investigation of highly conductive cerebrospinal fluid (CSF) during clinical use of electrical current based neuromodulation in MRI. However, very high and time varying velocities of typical CSF flow compared to the MHD flow velocities should also be considered.

6.
IEEE Trans Med Imaging ; 37(7): 1606-1617, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29969411

RESUMO

In this paper, induced current magnetic resonance electrical impedance tomography (ICMREIT) by means of current induction due to time-varying gradient fields of magnetic resonance imaging (MRI) systems is proposed. Eddy current and secondary magnetic flux density distributions are calculated for a numerical model composed of a z-gradient coil and a cylindrical conductor. An MRI pulse sequence is developed for the experimental evaluation of ICMREIT on a 3T MRI scanner. A relationship between the secondary magnetic flux density and the low-frequency (LF) MR phase is formulated. Characteristics of the LF phase, the eddy current, and the reconstructed conductivity distributions based on the simulated and the physical measurements are in agreement. Geometric shifts, which may contaminate the LF phase measurements, are not observed in the MR magnitude images. Low sensitivity of the LF phase measurements is a major limitation of ICMREIT towards clinical applications. The reconstructed conductivity images are rough estimates of true conductivity distribution of the experimental phantoms. Although the experimental results show that ICMREIT is safe and potentially applicable, its measurement sensitivity and reconstruction accuracy need to be optimized in order to improve the technique towards clinical applications.


Assuntos
Condutividade Elétrica , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Tomografia/métodos , Algoritmos , Imagens de Fantasmas , Razão Sinal-Ruído
7.
Annu Int Conf IEEE Eng Med Biol Soc ; 2015: 614-7, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26736337

RESUMO

In this paper, recently proposed Induced Current Magnetic Resonance Current Density Imaging (ICMRCDI) is experimentally realized. The reconstructed current density images from the simulated measurements and from the physical measurements are in agreement. The proposed method is promising in reconstructing images of electrical conductivity as well as images of induced current density distribution within the body.


Assuntos
Imageamento por Ressonância Magnética , Algoritmos , Condutividade Elétrica , Impedância Elétrica , Espectroscopia de Ressonância Magnética , Imagens de Fantasmas , Tomografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA