1.
Magn Reson Med ; 90(5): 2033-2051, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37332189

RESUMO

PURPOSE: The aim of this work is to introduce a single model-based deep network that can provide high-quality reconstructions from undersampled parallel MRI data acquired with multiple sequences, acquisition settings, and field strengths. METHODS: A single unrolled architecture, which offers good reconstructions for multiple acquisition settings, is introduced. The proposed scheme adapts the model to each setting by scaling the convolutional neural network (CNN) features and the regularization parameter with appropriate weights. The scaling weights and regularization parameter are derived using a multilayer perceptron model from conditional vectors, which represents the specific acquisition setting. The perceptron parameters and the CNN weights are jointly trained using data from multiple acquisition settings, including differences in field strengths, acceleration, and contrasts. The conditional network is validated using datasets acquired with different acquisition settings. RESULTS: The comparison of the adaptive framework, which trains a single model using the data from all the settings, shows that it can offer consistently improved performance for each acquisition condition. The comparison of the proposed scheme with networks that are trained independently for each acquisition setting shows that it requires less training data per acquisition setting to offer good performance. CONCLUSION: The Ada-MoDL framework enables the use of a single model-based unrolled network for multiple acquisition settings. In addition to eliminating the need to train and store multiple networks for different acquisition settings, this approach reduces the training data needed for each acquisition setting.


Assuntos
Aprendizado Profundo , Redes Neurais de Computação , Imageamento por Ressonância Magnética , Processamento de Imagem Assistida por Computador
2.
Adv Exp Med Biol ; 1380: 135-155, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36306097

RESUMO

Current density imaging (CDI) was developed with the aim of determining the three-dimensional distribution of externally applied electric current pathways inside a conductive medium, using measurements of magnetic flux density [Formula: see text] data. While the B field may be measurable using instruments such as a magnetometer, in magnetic resonance current density imaging (MR-CDI), an MRI scanner is used to measure the magnetic flux density data induced by current flow. In MR-CDI, the object must be rotated inside the MRI machine to find all three components of the B-field, as only the component of B parallel to the magnet main magnetic field can be measured. In principle, once the all three components of the B field have been obtained from an MR imaging experiment, the current density distribution [Formula: see text] can be reconstructed from Ampere's law [Formula: see text]. However, the need to rotate the object within the MRI scanner limits the usability of this technique. To overcome this problem, researchers have investigated the current density reconstruction problem using only one component of the magnetic flux density Bq, where q = x, y, z. In this chapter, we discuss numerical algorithms developed to reconstruct the distribution of J information from the measured B-field.


Assuntos
Algoritmos , Imageamento por Ressonância Magnética , Imageamento por Ressonância Magnética/métodos , Condutividade Elétrica , Espectroscopia de Ressonância Magnética , Imagens de Fantasmas , Impedância Elétrica
3.
Adv Exp Med Biol ; 1380: 157-183, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36306098

RESUMO

Magnetic Resonance Electrical Impedance Tomography (MREIT) is a high-resolution bioimpedance imaging technique that has developed over a period beginning in the early 1990s to measure low-frequency (<1 kHz) tissue electrical properties. Low-frequency electrical properties are particularly important because they provide valuable information on cell structures and ionic composition of tissues, which may be very useful for diagnostic purposes. MREIT uses one component of the magnetic flux density data induced due to an exogenous-current administration, measured using an MRI machine, to reconstruct isotropic or anisotropic electrical property distributions. The MREIT technique typically requires two linearly independent current administrations to reconstruct conductivity uniquely. Since its invention, researchers have explored its potential for measuring electrical conductivity in regions such as the brain and muscle tissue. It has also been investigated in disease models, for example, cerebral ischemia and early tumor detection. In this chapter, we aim to provide a solid foundation of the different MREIT image reconstruction algorithms, including both isotropic and anisotropic conductivity reconstruction approaches. We will also explore the newly developed diffusion tensor magnetic resonance electrical impedance tomography (DT-MREIT) method, a practical method for anisotropic tissue property imaging, at the end of the chapter.


Assuntos
Algoritmos , Imageamento por Ressonância Magnética , Impedância Elétrica , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética , Anisotropia , Condutividade Elétrica , Tomografia/métodos , Imagens de Fantasmas
4.
Annu Int Conf IEEE Eng Med Biol Soc ; 2021: 6725-6727, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34892651

RESUMO

Neuromodulation caused by transcranial electrical stimulation (TES) has been used successfully to treat various neuro-degenerative diseases. Simulation models provide an essential tool to study brain and nerve stimulation. Simulation models of TES provide an opportunity to research personalization of therapy without extensive animal and human testing. A computer model of a realistic sensory axon was built by finding actual geometry of the trigeminal nerve through tractography. A finite element model of the head was solved to obtain electric potential distribution caused by TES. Different waveforms were defined to test transcranial direct current stimulation (tDCS) and transcranial alternating current stimulation (tACS) with varying amplitude and frequency. Neural activity patterns were observed. The strength-duration curve was plotted to verify the model.


Assuntos
Transtornos Mentais , Estimulação Transcraniana por Corrente Contínua , Animais , Axônios , Encéfalo , Simulação por Computador , Humanos
5.
PLoS One ; 16(7): e0254690, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34293014

RESUMO

Diffusion tensor magnetic resonance electrical impedance tomography (DT-MREIT) is a newly developed technique that combines MR-based measurements of magnetic flux density with diffusion tensor MRI (DT-MRI) data to reconstruct electrical conductivity tensor distributions. DT-MREIT techniques normally require injection of two independent current patterns for unique reconstruction of conductivity characteristics. In this paper, we demonstrate an algorithm that can be used to reconstruct the position dependent scale factor relating conductivity and diffusion tensors, using flux density data measured from only one current injection. We demonstrate how these images can also be used to reconstruct electric field and current density distributions. Reconstructions were performed using a mimetic algorithm and simulations of magnetic flux density from complementary electrode montages, combined with a small-scale machine learning approach. In a biological tissue phantom, we found that the method reduced relative errors between single-current and two-current DT-MREIT results to around 10%. For in vivo human experimental data the error was about 15%. These results suggest that incorporation of machine learning may make it easier to recover electrical conductivity tensors and electric field images during neuromodulation therapy without the need for multiple current administrations.


Assuntos
Algoritmos , Imagem de Tensor de Difusão/instrumentação , Condutividade Elétrica , Campos Eletromagnéticos , Aprendizado de Máquina , Imagens de Fantasmas , Humanos
6.
Phys Med Biol ; 65(22): 225016, 2020 11 17.
Artigo em Inglês | MEDLINE | ID: mdl-32987377

RESUMO

Conventional magnetic resonance electrical impedance tomography (MREIT) reconstruction methods require administration of two linearly independent currents via at least two electrode pairs. This requires long scanning times and inhibits coordination of MREIT measurements with electrical neuromodulation strategies. We sought to develop an isotropic conductivity reconstruction algorithm in MREIT based on a single current injection, both to decrease scanning time by a factor of two and enable MREIT measurements to be conveniently adapted to general transcranial- or implanted-electrode neurostimulation protocols. In this work, we propose and demonstrate an iterative algorithm that extends previously published MREIT work using two-current administration approaches. The proposed algorithm is a single-current adaptation of the harmonic B z algorithm. Forward modeling of electric potentials is used to capture changes of conductivity along current directions that would normally be invisible using data from a single-current administration. Computational and experimental results show that the reconstruction algorithm is capable of reconstructing isotropic conductivity images that agree well in terms of L 2 error and structural similarity with exact conductivity distributions or two-current-based MREIT reconstructions. We conclude that it is possible to reconstruct high quality electrical conductivity images using MREIT techniques and one current injection only.


Assuntos
Condutividade Elétrica , Processamento de Imagem Assistida por Computador/métodos , Tomografia , Algoritmos , Impedância Elétrica , Imagens de Fantasmas
7.
IEEE Trans Med Imaging ; 38(7): 1569-1577, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30507528

RESUMO

Human brain mapping of low-frequency electrical conductivity tensors can realize patient-specific volume conductor models for neuroimaging and electrical stimulation. We report experimental validation and in vivo human experiments of a new electrodeless conductivity tensor imaging (CTI) method. From CTI imaging of a giant vesicle suspension using a 9.4-T MRI scanner, the relative error in the reconstructed conductivity tensor image was found to be less than 1.7% compared with the measured value using an impedance analyzer. In vivo human brain imaging experiments of five subjects were followed using a 3-T clinical MRI scanner. With the spatial resolution of 1.87 mm, the white matter conductivity showed considerably more position dependency compared with the gray matter and cerebrospinal fluid (CSF). The anisotropy ratio of the white matter was in the range of 1.96-3.25 with a mean value of 2.43, whereas that of the gray matter was in the range of 1.12-1.19 with a mean value of 1.16. The three diagonal components of the reconstructed conductivity tensors were from 0.08 to 0.27 S/m for the white matter, from 0.20 to 0.30 S/m for the gray matter, and from 1.55 to 1.82 S/m for the CSF. The reconstructed conductivity tensor images exhibited significant inter-subject variabilities in terms of frequency and position dependencies. The high-frequency and low-frequency conductivity values can quantify the total and extracellular water contents, respectively, at every pixel. Their difference can quantify the intracellular water content at every pixel. The CTI method can separately quantify the contributions of ion concentrations and mobility to the conductivity tensor.


Assuntos
Encéfalo/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Anisotropia , Condutividade Elétrica , Feminino , Humanos , Masculino , Imagens de Fantasmas , Suspensões/química , Adulto Jovem
8.
Sci Rep ; 8(1): 290, 2018 01 10.
Artigo em Inglês | MEDLINE | ID: mdl-29321483

RESUMO

Techniques for electrical brain stimulation (EBS), in which weak electrical stimulation is applied to the brain, have been extensively studied in various therapeutic brain functional applications. The extracellular fluid in the brain is a complex electrolyte that is composed of different types of ions, such as sodium (Na+), potassium (K+), and calcium (Ca+). Abnormal levels of electrolytes can cause a variety of pathological disorders. In this paper, we present a novel technique to visualize the total electrolyte concentration in the extracellular compartment of biological tissues. The electrical conductivity of biological tissues can be expressed as a product of the concentration and the mobility of the ions. Magnetic resonance electrical impedance tomography (MREIT) investigates the electrical properties in a region of interest (ROI) at low frequencies (below 1 kHz) by injecting currents into the brain region. Combining with diffusion tensor MRI (DT-MRI), we analyze the relation between the concentration of ions and the electrical properties extracted from the magnetic flux density measurements using the MREIT technique. By measuring the magnetic flux density induced by EBS, we propose a fast non-iterative technique to visualize the total extracellular electrolyte concentration (EEC), which is a fundamental component of the conductivity. The proposed technique directly recovers the total EEC distribution associated with the water transport mobility tensor.


Assuntos
Encéfalo/fisiologia , Estimulação Elétrica , Neuroimagem Funcional , Algoritmos , Animais , Impedância Elétrica , Eletrólitos , Neuroimagem Funcional/métodos , Humanos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética/métodos , Modelos Teóricos , Imagens de Fantasmas , Tomografia
9.
Biomed Eng Lett ; 8(3): 273-282, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30603211

RESUMO

The electrical conductivity is a passive material property primarily determined by concentrations of charge carriers and their mobility. The macroscopic conductivity of a biological tissue at low frequency may exhibit anisotropy related with its structural directionality. When expressed as a tensor and properly quantified, the conductivity tensor can provide diagnostic information of numerous diseases. Imaging conductivity distributions inside the human body requires probing it by externally injecting conduction currents or inducing eddy currents. At low frequency, the Faraday induction is negligible and it has been necessary in most practical cases to inject currents through surface electrodes. Here we report a novel method to reconstruct conductivity tensor images using an MRI scanner without current injection. This electrodeless method of conductivity tensor imaging (CTI) utilizes B1 mapping to recover a high-frequency isotropic conductivity image which is influenced by contents in both extracellular and intracellular spaces. Multi-b diffusion weighted imaging is then utilized to extract the effects of the extracellular space and incorporate its directional structural property. Implementing the novel CTI method in a clinical MRI scanner, we reconstructed in vivo conductivity tensor images of canine brains. Depending on the details of the implementation, it may produce conductivity contrast images for conductivity weighted imaging (CWI). Clinical applications of CTI and CWI may include imaging of tumor, ischemia, inflammation, cirrhosis, and other diseases. CTI can provide patient-specific models for source imaging, transcranial dc stimulation, deep brain stimulation, and electroporation.

10.
IEEE Trans Biomed Eng ; 64(11): 2505-2514, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28767360

RESUMO

OBJECTIVE: Low-frequency conductivity and current density imaging using MRI includes magnetic resonance electrical impedance tomography (MREIT), diffusion tensor MREIT (DT-MREIT), conductivity tensor imaging (CTI), and magnetic resonance current density imaging (MRCDI). MRCDI and MREIT provide current density and isotropic conductivity images, respectively, using current-injection phase MRI techniques. DT-MREIT produces anisotropic conductivity tensor images by incorporating diffusion weighted MRI into MREIT. These current-injection techniques are finding clinical applications in diagnostic imaging and also in transcranial direct current stimulation (tDCS), deep brain stimulation (DBS), and electroporation where treatment currents can function as imaging currents. To avoid adverse effects of nerve and muscle stimulations due to injected currents, conductivity tensor imaging (CTI) utilizes B1 mapping and multi-b diffusion weighted MRI to produce low-frequency anisotropic conductivity tensor images without injecting current. This paper describes numerical implementations of several key mathematical functions for conductivity and current density image reconstructions in MRCDI, MREIT, DT-MREIT, and CTI. METHODS: To facilitate experimental studies of clinical applications, we developed a software toolbox for these low-frequency conductivity and current density imaging methods. This MR-based conductivity imaging (MRCI) toolbox includes 11 toolbox functions which can be used in the MATLAB environment. RESULTS: The MRCI toolbox is available at http://iirc.khu.ac.kr/software.html . Its functions were tested by using several experimental datasets, which are provided together with the toolbox. CONCLUSION: Users of the toolbox can focus on experimental designs and interpretations of reconstructed images instead of developing their own image reconstruction softwares. We expect more toolbox functions to be added from future research outcomes. OBJECTIVE: Low-frequency conductivity and current density imaging using MRI includes magnetic resonance electrical impedance tomography (MREIT), diffusion tensor MREIT (DT-MREIT), conductivity tensor imaging (CTI), and magnetic resonance current density imaging (MRCDI). MRCDI and MREIT provide current density and isotropic conductivity images, respectively, using current-injection phase MRI techniques. DT-MREIT produces anisotropic conductivity tensor images by incorporating diffusion weighted MRI into MREIT. These current-injection techniques are finding clinical applications in diagnostic imaging and also in transcranial direct current stimulation (tDCS), deep brain stimulation (DBS), and electroporation where treatment currents can function as imaging currents. To avoid adverse effects of nerve and muscle stimulations due to injected currents, conductivity tensor imaging (CTI) utilizes B1 mapping and multi-b diffusion weighted MRI to produce low-frequency anisotropic conductivity tensor images without injecting current. This paper describes numerical implementations of several key mathematical functions for conductivity and current density image reconstructions in MRCDI, MREIT, DT-MREIT, and CTI. METHODS: To facilitate experimental studies of clinical applications, we developed a software toolbox for these low-frequency conductivity and current density imaging methods. This MR-based conductivity imaging (MRCI) toolbox includes 11 toolbox functions which can be used in the MATLAB environment. RESULTS: The MRCI toolbox is available at http://iirc.khu.ac.kr/software.html . Its functions were tested by using several experimental datasets, which are provided together with the toolbox. CONCLUSION: Users of the toolbox can focus on experimental designs and interpretations of reconstructed images instead of developing their own image reconstruction softwares. We expect more toolbox functions to be added from future research outcomes.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Software , Algoritmos , Animais , Encéfalo/diagnóstico por imagem , Cães , Impedância Elétrica , Cabeça/diagnóstico por imagem , Humanos , Perna (Membro)/diagnóstico por imagem , Imagens de Fantasmas , Ratos , Estimulação Transcraniana por Corrente Contínua
11.
Int Neurourol J ; 21(Suppl 1): S32-38, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28446015

RESUMO

PURPOSE: To realistically map the electric fields of biological tissues using a diffusion tensor magnetic resonance electrical impedance tomography (DT-MREIT) method to estimate tissue response during electrical stimulation. METHODS: Imaging experiments were performed using chunks of bovine muscle. Two silver wire electrodes were positioned inside the muscle tissue for electrical stimulation. Electric pulses were applied with a 100-V amplitude and 100-µs width using a voltage stimulator. During electrical stimulation, we collected DT-MREIT data from a 3T magnetic resonance imaging scanner. We adopted the projected current density method to calculate the electric field. Based on the relation between the water diffusion tensor and the conductivity tensor, we computed the position-dependent scale factor using the measured magnetic flux density data. Then, a final conductivity tensor map was reconstructed using the multiplication of the water diffusion tensor and the scale factor. RESULTS: The current density images from DT-MREIT data represent the internal current flows that exist not only in the electrodes but also in surrounding regions. The reconstructed electric filed map from our anisotropic conductivity tensor with the projected current density shows coverage that is more than 2 times as wide, and higher signals in both the electrodes and surrounding tissues, than the previous isotropic method owing to the consideration of tissue anisotropy. CONCLUSIONS: An electric field map obtained by an anisotropic reconstruction method showed different patterns from the results of the previous isotropic reconstruction method. Since accurate electric field mapping is important to correctly estimate the coverage of the electrical treatment, future studies should include more rigorous validations of the new method through in vivo and in situ experiments.

12.
IEEE Trans Med Imaging ; 36(1): 124-131, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-28055828

RESUMO

We present in vivo images of anisotropic electrical conductivity tensor distributions inside canine brains using diffusion tensor magnetic resonance electrical impedance tomography (DT-MREIT). The conductivity tensor is represented as a product of an ion mobility tensor and a scale factor of ion concentrations. Incorporating directional mobility information from water diffusion tensors, we developed a stable process to reconstruct anisotropic conductivity tensor images from measured magnetic flux density data using an MRI scanner. Devising a new image reconstruction algorithm, we reconstructed anisotropic conductivity tensor images of two canine brains with a pixel size of 1.25 mm. Though the reconstructed conductivity values matched well in general with those measured by using invasive probing methods, there were some discrepancies as well. The degree of white matter anisotropy was 2 to 4.5, which is smaller than previous findings of 5 to 10. The reconstructed conductivity value of the cerebrospinal fluid was about 1.3 S/m, which is smaller than previous measurements of about 1.8 S/m. Future studies of in vivo imaging experiments with disease models should follow this initial trial to validate clinical significance of DT-MREIT as a new diagnostic imaging modality. Applications in modeling and simulation studies of bioelectromagnetic phenomena including source imaging and electrical stimulation are also promising.


Assuntos
Encéfalo , Algoritmos , Animais , Anisotropia , Cães , Condutividade Elétrica , Impedância Elétrica , Imageamento por Ressonância Magnética , Imagens de Fantasmas
13.
IEEE Trans Biomed Eng ; 63(1): 168-75, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26111387

RESUMO

OBJECTIVE: Transcranial direct current stimulation (tDCS) is a neuromodulatory technique for neuropsychiatric diseases and neurological disorders. In the tDCS treatment, dc current is injected into the head through a pair of electrodes attached on the scalp over a target region. A current density imaging method is needed to quantitatively visualize the internal current density distribution during the tDCS treatment. METHODS: We developed a novel current density image reconstruction algorithm using 1) a subject specific segmented 3-D head model, 2) diffusion tensor data, and 3) magnetic flux density data induced by the tDCS current. We acquired T1 weighted and diffusion tensor images of the head using the MRI scanner before the treatment. During the treatment, we can measure the induced magnetic flux density data using a magnetic resonance electrical impedance tomography (MREIT) pulse sequence. In this paper, the magnetic flux density data were numerically generated. RESULTS: Numerical simulation results show that the proposed method successfully recovers the current density distribution including the effects of the anisotropic, as well as isotropic conductivity values of different tissues in the head. CONCLUSION: The proposed current density imaging method using DT-MRI and MREIT can reliably recover cross-sectional images of the current density distribution during the tDCS treatment. SIGNIFICANCE: Success of the tDCS treatment depends on a precise determination of the induced current density distribution within different anatomical structures of the brain. Quantitative visualization of the current density distribution in the brain will play an important role in understanding the effects of the electrical stimulation.


Assuntos
Algoritmos , Simulação por Computador , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Estimulação Transcraniana por Corrente Contínua/métodos , Adulto , Impedância Elétrica , Feminino , Cabeça/fisiologia , Humanos
14.
Phys Med Biol ; 59(16): 4723-38, 2014 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-25082797

RESUMO

Magnetic resonance electrical impedance tomography (MREIT) is a promising non-invasive method to visualize a static cross-sectional conductivity and/or current density image by injecting low frequency currents. MREIT measures one component of the magnetic flux density caused by the injected current using a magnetic resonance (MR) scanner. For practical in vivo implementations of MREIT, especially for soft biological tissues where the MR signal rapidly decays, it is crucial to develop a technique for optimizing the magnetic flux density signal by the injected current while maintaining spatial-resolution and contrast. We design an MREIT pulse sequence by applying a spoiled multi-gradient-echo pulse sequence (SPMGE) to the injected current nonlinear encoding (ICNE), which fully injects the current at the end of the read-out gradient. The applied ICNE-SPMGE pulse sequence maximizes the duration of injected current almost up to a repetition time by measuring multiple magnetic flux density data. We analyze the noise level of measured magnetic flux density with respect to the pulse width of injection current and T*(2) relaxation time. In due consideration of the ICNE-SPMGE pulse sequence, using a reference information of T*(2) values in a local region of interest by a short pre-scan data, we predict the noise level of magnetic flux density to be measured for arbitrary repetition time TR. Results from phantom experiment demonstrate that the proposed method can predict the noise level of magnetic flux density for an appropriate TR = 40 ms using a reference scan for TR = 75 ms. The predicted noise level was compared with the noise level of directly measured magnetic flux density data.


Assuntos
Fenômenos Magnéticos , Razão Sinal-Ruído , Tomografia/métodos , Impedância Elétrica , Estudos de Viabilidade , Imagens de Fantasmas , Tomografia/instrumentação
15.
Phys Med Biol ; 59(17): 4827-44, 2014 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-25097180

RESUMO

Magnetic Resonance Electrical Impedance Tomography (MREIT) is an MRI method that enables mapping of internal conductivity and/or current density via measurements of magnetic flux density signals. The MREIT measures only the z-component of the induced magnetic flux density B = (Bx, By, Bz) by external current injection. The measured noise of Bz complicates recovery of magnetic flux density maps, resulting in lower quality conductivity and current-density maps. We present a new method for more accurate measurement of the spatial gradient of the magnetic flux density gradient (∇ Bz). The method relies on the use of multiple radio-frequency receiver coils and an interleaved multi-echo pulse sequence that acquires multiple sampling points within each repetition time. The noise level of the measured magnetic flux density Bz depends on the decay rate of the signal magnitude, the injection current duration, and the coil sensitivity map. The proposed method uses three key steps. The first step is to determine a representative magnetic flux density gradient from multiple receiver coils by using a weighted combination and by denoising the measured noisy data. The second step is to optimize the magnetic flux density gradient by using multi-echo magnetic flux densities at each pixel in order to reduce the noise level of ∇ Bz and the third step is to remove a random noise component from the recovered ∇ Bz by solving an elliptic partial differential equation in a region of interest. Numerical simulation experiments using a cylindrical phantom model with included regions of low MRI signal to noise ('defects') verified the proposed method. Experimental results using a real phantom experiment, that included three different kinds of anomalies, demonstrated that the proposed method reduced the noise level of the measured magnetic flux density. The quality of the recovered conductivity maps using denoised ∇ Bz data showed that the proposed method reduced the conductivity noise level up to 3-4 times at each anomaly region in comparison to the conventional method.


Assuntos
Algoritmos , Imageamento por Ressonância Magnética/métodos , Impedância Elétrica , Imagens de Fantasmas , Ondas de Rádio
16.
IEEE Trans Biomed Eng ; 61(7): 1938-46, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24956612

RESUMO

Magnetic resonance electrical impedance tomography (MREIT) is an imaging modality capable of visualizing cross-sectional current density and/or conductivity distributions inside an electrically conducting object. It uses an MRI scanner to measure one component of the magnetic flux density induced by an externally injected current through a pair of surface electrodes. For the cases of deep brain stimulation (DBS), electroporation, and radio frequency (RF) ablation, internal electrodes can be used to improve the quality of the MREIT images. In this paper, we propose a new MREIT imaging method using internal electrodes to visualize a current density distribution within a local region around them. To evaluate its performance, we conducted and analyzed a series of numerical simulations and phantom imaging experiments. We compared the reconstructed current density images using the internal electrodes with the obtained using only the external electrodes. We found that the proposed method using the internal electrodes stably determines the current density in the focused region with better accuracy.


Assuntos
Impedância Elétrica , Imageamento por Ressonância Magnética/instrumentação , Tomografia/instrumentação , Tomografia/métodos , Simulação por Computador , Eletrodos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Razão Sinal-Ruído
17.
Phys Med Biol ; 59(12): 2955-74, 2014 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-24841854

RESUMO

Magnetic resonance electrical impedance tomography (MREIT) is an emerging method to visualize electrical conductivity and/or current density images at low frequencies (below 1 KHz). Injecting currents into an imaging object, one component of the induced magnetic flux density is acquired using an MRI scanner for isotropic conductivity image reconstructions. Diffusion tensor MRI (DT-MRI) measures the intrinsic three-dimensional diffusion property of water molecules within a tissue. It characterizes the anisotropic water transport by the effective diffusion tensor. Combining the DT-MRI and MREIT techniques, we propose a novel direct method for absolute conductivity tensor image reconstructions based on a linear relationship between the water diffusion tensor and the electrical conductivity tensor. We first recover the projected current density, which is the best approximation of the internal current density one can obtain from the measured single component of the induced magnetic flux density. This enables us to estimate a scale factor between the diffusion tensor and the conductivity tensor. Combining these values at all pixels with the acquired diffusion tensor map, we can quantitatively recover the anisotropic conductivity tensor map. From numerical simulations and experimental verifications using a biological tissue phantom, we found that the new method overcomes the limitations of each method and successfully reconstructs both the direction and magnitude of the conductivity tensor for both the anisotropic and isotropic regions.


Assuntos
Tomografia/métodos , Água/metabolismo , Anisotropia , Difusão , Impedância Elétrica , Espectroscopia de Ressonância Magnética , Modelos Teóricos , Razão Sinal-Ruído
18.
Biomed Eng Online ; 13(1): 24, 2014 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-24607262

RESUMO

BACKGROUND: The spectroscopic conductivity distribution of tissue can help to explain physiological and pathological status. Dual frequency conductivity imaging by combining Magnetic Resonance Electrical Property Tomography (MREPT) and Magnetic Resonance Electrical Impedance Tomography (MREIT) has been recently proposed. MREIT can provide internal conductivity distributions at low frequency (below 1 kHz) induced by an external injecting current. While MREPT can provide conductivity at the Larmor frequency related to the strength of the magnetic field. Despite this potential to describe the membrane properties using spectral information, MREPT and MREIT techniques currently suffer from weak signals and noise amplification as they both reply on differentiation of measured phase data. METHODS: We proposed a method to optimize the measured phase signal by finding weighting factors according to the echo signal for MREPT and MREIT using the ICNE (Injected current nonlinear encoding) multi-echo pulse sequence. Our target weights are chosen to minimize the measured noise. The noise standard deviations were precisely analyzed for the optimally weighted magnetic flux density and the phase term of the positive-rotating magnetic field. To enhance the quality of dual-frequency conductivity images, we applied the denoising method based on the reaction-diffusion equation with the estimated noise standard deviations. A real experiment was performed with a hollow cylindrical object made of thin insulating film with holes to control the apparent conductivity using ion mobility and an agarose gel cylinder wrapped in an insulating film without holes to show different spectroscopic conductivities. RESULTS: The ability to image different conductivity characteristics in MREPT and MREIT from a single MR scan was shown by including the two objects with different spectroscopic conductivities. Using the six echo signals, we computed the optimized weighting factors for each echo. The qualities of conductivity images for MREPT and MREIT were improved by optimization of the phase map. The proposed method effectively reduced the random noise artifacts for both MREIT and MREPT. CONCLUSION: We enhanced the dual conductivity images using the optimally weighted magnetic flux density and the phase term of positive-rotating magnetic field based on the analysis of the noise standard deviations and applying the optimization and denoising methods.


Assuntos
Imageamento por Ressonância Magnética/métodos , Espectrofotometria/métodos , Algoritmos , Impedância Elétrica , Géis/química , Humanos , Processamento de Imagem Assistida por Computador/métodos , Sefarose/química , Processamento de Sinais Assistido por Computador , Tomografia/métodos
19.
Magn Reson Med ; 71(1): 200-8, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23400804

RESUMO

PURPOSE: To propose a single magnetic resonance scan conductivity imaging technique providing dual-frequency characteristics of tissue conductivity. METHODS: Using a modified spin-echo pulse sequence, the magnetic flux density induced by externally injected currents and the B1+ phase map with injected current effects removed were acquired simultaneously. The low-frequency conductivity was reconstructed from the measured magnetic flux density by the projected current density method, while the high-frequency conductivity was reconstructed using the B1+ maps. Three different conductivity phantoms were used to demonstrate low- and high-frequency conductivity characteristics. RESULTS: A conductivity spectrum at two frequencies was successfully acquired with the proposed scheme. Magnetic resonance electrical impedance tomography is advantageous for seeing an anomaly itself wrapped with a thin insulating membrane. In addition, if the membrane is porous, the membrane property can be quantitatively visualized with magnetic resonance electrical impedance tomography. Magnetic resonance electrical properties tomography does not detect such membranes, which enable it to probe things inside an insulating membrane. CONCLUSION: Considering these pros and cons and also the fact that the conductivity of biological tissue changes with frequency, a dual-frequency conductivity imaging incorporating both magnetic resonance electrical impedance tomography and magnetic resonance electrical properties tomography in future animal and human experiments is suggested.


Assuntos
Espectroscopia Dielétrica/métodos , Condutividade Elétrica , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Imagem Multimodal/métodos , Espectroscopia Dielétrica/instrumentação , Humanos , Imageamento por Ressonância Magnética/instrumentação , Imagem Multimodal/instrumentação , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
20.
Comput Math Methods Med ; 2013: 704829, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23737862

RESUMO

Magnetic resonance electrical impedance tomography (MREIT) is a new modality capable of imaging the electrical properties of human body using MRI phase information in conjunction with external current injection. Recent in vivo animal and human MREIT studies have revealed unique conductivity contrasts related to different physiological and pathological conditions of tissues or organs. When performing in vivo brain imaging, small imaging currents must be injected so as not to stimulate peripheral nerves in the skin, while delivery of imaging currents to the brain is relatively small due to the skull's low conductivity. As a result, injected imaging currents may induce small phase signals and the overall low phase SNR in brain tissues. In this study, we present numerical simulation results of the use of head MREIT for brain tumor detection. We used a realistic three-dimensional head model to compute signal levels produced as a consequence of a predicted doubling of conductivity occurring within simulated tumorous brain tissues. We determined the feasibility of measuring these changes in a time acceptable to human subjects by adding realistic noise levels measured from a candidate 3 T system. We also reconstructed conductivity contrast images, showing that such conductivity differences can be both detected and imaged.


Assuntos
Neoplasias Encefálicas/diagnóstico , Impedância Elétrica , Imageamento por Ressonância Magnética/métodos , Animais , Biologia Computacional , Simulação por Computador , Diagnóstico por Computador/estatística & dados numéricos , Análise de Elementos Finitos , Humanos , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional/estatística & dados numéricos , Imageamento por Ressonância Magnética/estatística & dados numéricos , Modelos Neurológicos , Razão Sinal-Ruído