Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Oper Dent ; 47(5): 549-561, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-36026699

RESUMO

This study aimed to evaluate the effect of desensitizing and conventional mouth rinses on dentin tubule occlusion. Dentin hypersensitivity was simulated by EDTA application for five minutes. The specimens were randomly allocated into the following groups: desensitizing mouth rinses (Colgate Sensitive, Elmex Sensitive Professional, Listerine Advanced Defense Sensitive, Sensodyne Cool Mint); conventional mouth rinses (Colgate Plax, Elmex Caries Protection, Listerine Anticaries, Sensodyne Pronamel); a negative control (C-: distilled water); and Clinpro XT Varnish was the positive control (C+). Subsequently, the specimens were submitted to an erosive or abrasive challenge (performed separately) and to an erosive/abrasive cycling for five days (n=10 for each challenge). After treatment, challenges, and cycling, the specimens were analyzed in an environmental scanning electron microscope to verify the number of open dentin tubules (ODTs), counted by using Image J software (National Institutes of Health, Bethesda, MD, USA). Data were analyzed by the Kruskal-Wallis, Friedman and Dunn tests, with Bonferroni correction (α=0.05). Groups did not differ at baseline (p>0.05). At the post-treatment, erosion and abrasion stages, C+ was the only group that showed a reduction in ODTs compared to C-(p<0.05). In the other groups, numbers did not differ significantly from C- (p>0.05). After cycling, none of the groups exhibited significant reduction in ODTs other than C- (p>0.05); however, C+, Listerine Anticaries, and Colgate Plax had a lower number of ODTs than Listerine Sensitive and Sensodyne Pronamel. No mouth rinse was able to promote significant occlusion of the dentin tubules after treatment and the challenges. C+ was the only product that effectively promoted tubular occlusion, but this effect did not withstand several erosive and abrasive challenges.


Assuntos
Dessensibilizantes Dentinários , Benzoatos , Dentina , Dessensibilizantes Dentinários/farmacologia , Dessensibilizantes Dentinários/uso terapêutico , Diaminas , Ácido Edético , Fluoretos , Microscopia Eletrônica de Varredura , Antissépticos Bucais/farmacologia , Antissépticos Bucais/uso terapêutico , Dodecilsulfato de Sódio , Fluoreto de Sódio , Água
2.
Oper Dent ; 44(2): 168-177, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-29953338

RESUMO

PURPOSE:: The purpose of this study was to evaluate the effects of four in-office desensitizing products on dentin tubule occlusion and erosive wear. METHODS:: Dentin hypersensitivity was simulated by EDTA application for five minutes. The specimens were randomly allocated into five groups (n=11), according to treatment: No treatment - Control (C), Duraphat (DUR), Desensibilize Nano P (NP), ClinPro XT Varnish (XTV), and ClinPro White Varnish (CWV). They were then submitted to erosive/abrasive cycling for five days. After EDTA, treatment, and cycling, the specimens were analyzed with an environmental scanning electron microscope (ESEM) to verify the number of opened dentin tubules (ODT) which were counted by using ImageJ software, and with a profilometer to determine the surface curvature/loss. ESEM data were analyzed with two-way repeated measure analysis of variance and Tukey tests. For the profilometer, data were analyzed with Kruskal-Wallis, Tukey, and Mann-Whitney tests. RESULTS:: After treatment, all groups showed lower ODT than the control, without significant differences between them. After cycling, the only group that showed lower ODT than the control was group XTV; however, it did not significantly differ from the other groups. For the profilometric analysis, there were significant differences in SL between the experimental times after treatment and after cycling for all groups ( p<0.05). After cycling, no surface loss was detected in groups DUR and XTV, which presented a significantly different curvature than group NP and the control group, but not from group CWV. Surface loss was detected for the control and groups NP and CWV, without difference among them. CONCLUSION:: All desensitizing agents tested presented promising results concerning the obliteration of dentin tubules immediately after treatment. XTV was the only desensitizer capable of preventing the reopening of the tubules after the erosive/abrasive challenges. XTV and DUR presented a protective effect against dentin erosive wear.


Assuntos
Dessensibilizantes Dentinários , Sensibilidade da Dentina , Desgaste dos Dentes , Dentina , Humanos , Microscopia Eletrônica de Varredura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA