Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 137
Filtrar
3.
J Invasive Cardiol ; 34(10): E730-E738, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36166361

RESUMO

PURPOSE: The study aim was to evaluate the impact of extravascular ultrasound-guided (EVUSG) wiring on achieving optimal vessel preparation and patency in endovascular therapy (EVT) for superficial femoral artery (SFA) chronic total occlusion (CTO). METHODS: Between April 2007 and January 2019, a total of 239 SFA-CTO limbs were successfully treated with EVT and bailout implantation of self-expandable nitinol stents at our hospital. The study subjects were divided into 2 groups according to the type of guidance strategy used during CTO wiring, ie, the EVUSG group and the conventional angiography guidance (AG) group. Immediately after the initial balloon angioplasty and successful passage of the wire through the SFA-CTO lesions, the EVUSG (65 limbs) and AG groups (174 limbs) were retrospectively evaluated for angiographic dissection patterns. The primary patency rate was also compared between the 2 groups. RESULTS: No significant difference was observed in the balloon diameter at the initial dilation immediately after successful wire passing (3.7 ± 0.5 mm in the EVUSG group vs 3.8 ± 0.5 mm in the AG group; P=.17). The incidence of severe dissection was significantly lower (P<.001) in the EVUSG group (28/65; 43%) than in the AG group (137/174; 79%). The 3-year primary patency rates in the EVUSG and AG groups were 84.5% and 68.4%, respectively (P<.001). CONCLUSIONS: EVUSG for SFA-CTO may achieve optimal vessel preparation, defined as an initial balloon angioplasty without severe dissection, and subsequent implantation of self-expandable stents may lead to a better patency rate.


Assuntos
Angioplastia com Balão , Doença Arterial Periférica , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/cirurgia , Humanos , Doença Arterial Periférica/diagnóstico , Doença Arterial Periférica/cirurgia , Estudos Retrospectivos , Stents , Resultado do Tratamento , Ultrassonografia de Intervenção , Grau de Desobstrução Vascular
4.
Eur J Cancer ; 174: 40-47, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35970035

RESUMO

BACKGROUND: This phase 1b trial evaluated the toxicity and efficacy of S-1, irinotecan, and oxaliplatin combination therapy (S-IROX) as first-line chemotherapy in patients with advanced pancreatic cancer (APC). METHODS: Patients aged 20-75 years with APC and an Eastern Cooperative Oncology Group performance status of 0 or 1 were eligible to receive escalating doses of S-1 (60 or 80 mg m2·day) on days 1-7, fixed doses of oxaliplatin (85 mg/m2) biweekly, and escalating doses of irinotecan (150, 165, or 180 mg/m2) once every 2 weeks. In the dose-escalation cohort, a 3 + 3 design was used to determine the maximum-tolerated dose (MTD) and explore the recommended dose (RD). A dose-expansion cohort was added to further evaluate the safety and efficacy of the combination. This trial was registered at UMIN-CTR (UMIN000012054). RESULTS: Approximately 47 patients were enrolled, of whom 45 were eligible for the analysis. The MTD was not determined, but the RD was determined to be dose level 1 based on a review of data from each level. Among the 45 patients, the ORR was 51.1% [95% confidence interval (CI), 35.8-66.3%]. The median progression-free survival and median overall survival was 6.9 months (95% CI, 5.1-8.8 months) and 15.8 months (95% CI, 9.8-20.8 months), respectively. Common adverse events included neutropenia, elevated liver enzyme levels, diarrhoea, and nausea. CONCLUSIONS: The S-IROX regimen showed promising efficacy with manageable toxicities in Japanese patients with APC. A randomised phase 2/3 trial comparing S-IROX, mFOLFIRINOX, and gemcitabine plus nab-paclitaxel is currently ongoing (jRCTs031190009).


Assuntos
Camptotecina , Neoplasias Pancreáticas , Protocolos de Quimioterapia Combinada Antineoplásica/efeitos adversos , Camptotecina/efeitos adversos , Ensaios Clínicos Fase I como Assunto , Ensaios Clínicos Fase II como Assunto , Fluoruracila/efeitos adversos , Humanos , Irinotecano/efeitos adversos , Estudos Multicêntricos como Assunto , Compostos Organoplatínicos/efeitos adversos , Oxaliplatina/efeitos adversos , Neoplasias Pancreáticas/tratamento farmacológico , Neoplasias Pancreáticas/etiologia , Neoplasias Pancreáticas
5.
Int J Clin Oncol ; 26(11): 2065-2072, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34368921

RESUMO

BACKGROUND: Although FOLFIRINOX is currently one of the standard therapies for chemotherapy-naïve patients with metastatic pancreatic cancer (MPC), the high rate of febrile neutropenia (FN) presents a clinical problem. This study aimed to evaluate the safety and efficacy of primary prophylactic pegfilgrastim with FOLFIRINOX in Japanese MPC patients. METHODS: FOLFIRINOX (intravenous oxaliplatin 85 mg/m2, irinotecan 180 mg/m2, levofolinate 200 mg/m2, 5-fluorouracil (5-FU) bolus 400 mg/m2 and 5-FU 46 h infusion 2400 mg/m2) and pegfilgrastim 3.6 mg on day 4 or 5, every 2 weeks was administered to previously untreated MPC patients. The primary endpoint was the incidence of FN during the first 3 cycles. The planned sample size was 35 patients, but the trial was predefined to discontinue enrollment for safety if 4 patients developed FN. RESULTS: At the enrollment of 22 patients, 4 patients developed FN in the first cycle, resulting in an incidence of FN of 18% {95% confidence interval [CI], 0.5-40.3%}, and enrollment was discontinued early. The incidence of grade 3 or higher neutropenia was 36.4%. Median relative dose intensities during the initial 3 cycles of oxaliplatin, irinotecan, bolus 5-FU, infusional 5-FU, and levofolinate maintained high (100%, 89.0%, 100%, 66.0%, and 100%, respectively). Response rate and median overall survival were 54.5% (95% CI 32.7-74.9) and 15.7 months (95% CI 7.9-18.8), respectively. CONCLUSIONS: This phase II study could not demonstrate any reduction in the incidence of FN, nevertheless some patients experience benefits for efficacy by maintaining dose intensity using prophylactic pegfilgrastim. TRIAL REGISTRATION: http://www.umin.ac.jp/ctr/index-j.htm , UMIN000017538. Date of registration: May/13/2015.


Assuntos
Protocolos de Quimioterapia Combinada Antineoplásica , Neoplasias Pancreáticas , Protocolos de Quimioterapia Combinada Antineoplásica/efeitos adversos , Filgrastim , Fluoruracila/efeitos adversos , Humanos , Irinotecano/uso terapêutico , Japão , Leucovorina , Oxaliplatina/uso terapêutico , Neoplasias Pancreáticas/tratamento farmacológico , Polietilenoglicóis
6.
Liver Cancer ; 10(3): 249-259, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34239811

RESUMO

INTRODUCTION: Combining an immune checkpoint inhibitor with a targeted antiangiogenic agent may leverage complementary mechanisms of action for the treatment of advanced/metastatic hepatocellular carcinoma (aHCC). Avelumab is a human anti-PD-L1 IgG1 antibody with clinical activity in various tumor types; axitinib is a selective tyrosine kinase inhibitor of vascular endothelial growth factor receptors 1, 2, and 3. We report the final analysis from VEGF Liver 100 (NCT03289533), a phase 1b study evaluating safety and efficacy of avelumab plus axitinib in treatment-naive patients with aHCC. METHODS: Eligible patients had confirmed aHCC, no prior systemic therapy, ≥1 measurable lesion, Eastern Cooperative Oncology Group performance status ≤1, and Child-Pugh class A disease. Patients received avelumab 10 mg/kg intravenously every 2 weeks plus axitinib 5 mg orally twice daily until progression, unacceptable toxicity, or withdrawal. Endpoints included safety and investigator-assessed objective response per Response Evaluation Criteria in Solid Tumors (RECIST) 1.1 and modified RECIST (mRECIST) for HCC. RESULTS: Twenty-two Japanese patients were enrolled and treated with avelumab plus axitinib. The minimum follow-up was 18 months as of October 25, 2019 (data cutoff). Grade 3 treatment-related adverse events (TRAEs) occurred in 16 patients (72.7%); the most common (≥3 patients) were hypertension (n = 11 [50.0%]), palmar-plantar erythrodysesthesia syndrome (n = 5 [22.7%]), and decreased appetite (n = 3 [13.6%]). No grade 4 TRAEs or treatment-related deaths occurred. Ten patients (45.5%) had an immune-related AE (irAE) of any grade; 3 patients (13.6%) had an infusion-related reaction (IRR) of any grade, and no grade ≥3 irAE and IRR were observed. The objective response rate was 13.6% (95% CI: 2.9-34.9%) per RECIST 1.1 and 31.8% (95% CI: 13.9-54.9%) per mRECIST for HCC. CONCLUSION: Treatment with avelumab plus axitinib was associated with a manageable toxicity profile and showed antitumor activity in patients with aHCC.

7.
Heart Vessels ; 36(12): 1818-1824, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34050788

RESUMO

Drug-coated balloon (DCB) angioplasty for femoropopliteal (FP) lesions has been available in Japan since 2018. In daily practice, we encountered cases of the slow-flow phenomenon after DCB angioplasty. However, no data regarding the slow-flow phenomenon after DCB angioplasty for FP lesions are available. This study aimed to investigate the frequency, predictors, and effect of the slow-flow phenomenon following DCB angioplasty for FP lesions. This single-center, retrospective, observational study analyzed 88 FP lesions treated by DCB angioplasty between April 2018 and July 2019. Patients were divided into the slow-flow group (n = 7) and non-slow-flow group (n = 81) and were analyzed. The primary endpoint was primary patency at 6 months. The slow-flow phenomenon was observed in seven cases (8.0%). The slow-flow group had higher incidence rates of critical limb ischemia (CLI) (71% vs. 25%, p < 0.01), chronic total occlusion (CTO) lesions (86% vs. 26%, p < 0.01), and poor tibial vessel runoff (86% vs. 33%, p < 0.01) and had a longer DCB length (237 ± 56 mm vs. 159 ± 97 mm, p = 0.03) than the non-slow-flow group. The primary patency rate at 6 months was 71% in the slow-flow group and 91% in the non-slow-flow group (p = 0.09). The rate of freedom from target lesion revascularization at 6 months was 71% in the slow-flow group and 97% in the non-slow-flow group (p < 0.01). The amputation-free survival rate at 6 months was 71% and 95% (p = 0.02), whereas the survival rate at 6 months was 71% and 95% (p = 0.02). The incidence rate of the slow-flow phenomenon after DCB angioplasty for FP lesions was 8.0%. CLI, a CTO lesion, poor tibial vessel runoff, and total DCB length were associated with the slow-flow phenomenon. Our results indicate that the slow-flow phenomenon is associated with poor short-term clinical outcomes.


Assuntos
Angioplastia com Balão , Fenômeno de não Refluxo , Doença Arterial Periférica , Angioplastia com Balão/efeitos adversos , Isquemia Crônica Crítica de Membro , Materiais Revestidos Biocompatíveis , Artéria Femoral/diagnóstico por imagem , Humanos , Doença Arterial Periférica/terapia , Preparações Farmacêuticas , Artéria Poplítea/diagnóstico por imagem , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
8.
J Interv Cardiol ; 2021: 8852466, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33623483

RESUMO

INTRODUCTION: The proportion of patients with comorbid atrial fibrillation (AF) and peripheral artery disease (PAD) has increased in this era. This study aimed to assess the relationship between AF and totally occlusive in-stent restenosis (ISR) in femoropopliteal (FP) lesions. METHODS: In this study, 363 patients (461 stents) who underwent endovascular therapy with de novo stent implantation in our hospital between April 2007 and December 2016 were retrospectively evaluated. The patients were divided into two groups according to the AF status (AF group, 61 patients; sinus group, 302 patients). The primary endpoint was the incidence of totally occlusive ISR within 3 years. The secondary endpoint was the incidence of acute limb ischemia (ALI) due to FP stent occlusion. RESULTS: Baseline characteristics were similar, except for higher age and a lower prevalence of dyslipidemia in the AF group. The incidence of a totally occlusive ISR was higher in the AF group than in the sinus group (29.5% vs. 14.6%, p=0.004). A multiple Cox regression model suggested that presence of AF (hazard ratio, 2.10) and CTO lesion (hazard ratio, 1.97) which were the independent predictors of a totally occlusive ISR within 3 years. The incidence of ALI was significantly higher in the AF group than in the sinus group (3.9% vs. 0%, p=0.0001). In the AF group, the introduction of an anticoagulant did not prevent the occurrence of totally occlusive ISR (p=0.71) for ALI (p=0.79). CONCLUSIONS: AF is independently associated with totally occlusive ISR of FP stents; however, anticoagulant use does not prevent stent occlusion.


Assuntos
Arteriopatias Oclusivas , Fibrilação Atrial , Artéria Femoral , Oclusão de Enxerto Vascular/complicações , Artéria Poplítea , Enxerto Vascular , Anticoagulantes/uso terapêutico , Arteriopatias Oclusivas/fisiopatologia , Arteriopatias Oclusivas/terapia , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Correlação de Dados , Feminino , Artéria Femoral/patologia , Artéria Femoral/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Artéria Poplítea/patologia , Artéria Poplítea/cirurgia , Estudos Retrospectivos , Fatores de Risco , Stents/efeitos adversos , Resultado do Tratamento , Enxerto Vascular/efeitos adversos , Enxerto Vascular/instrumentação , Enxerto Vascular/métodos
9.
Gen Thorac Cardiovasc Surg ; 69(5): 882-884, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33400204

RESUMO

The Impella device can effectively unload the left ventricle in patients undergoing high-risk percutaneous coronary intervention (PCI) and in cases of cardiogenic shock. Herein, we report a rare case of a 59-year-old man who was treated using PCI and the Impella CP for acute coronary syndrome. The patient suffered from severe acute aortic regurgitation and complete atrioventricular block (CAVB) with hemodynamic instability soon after the Impella removal. The non-coronary cusp (NCC) tear occurred from the NCC and right coronary cusp commissure to the middle of the NCC. The patient successfully underwent aortic valve replacement with no CAVB postoperatively.


Assuntos
Bloqueio Atrioventricular , Coração Auxiliar , Intervenção Coronária Percutânea , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Bloqueio Atrioventricular/diagnóstico , Bloqueio Atrioventricular/etiologia , Bloqueio Atrioventricular/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Choque Cardiogênico/etiologia , Choque Cardiogênico/terapia
10.
Heart Vessels ; 36(3): 376-382, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32889645

RESUMO

To investigate the usefulness of ultrasound-guided (USG) intraluminal approach for femoropopliteal (FP) lesion. 64 patients (73 limbs) with de novo long occlusive (> 15 cm) FP lesions underwent USG intralumial approach from April 2012 to October 2016. Periprocedural intravascular ultrasound findings were collected. Clinical outcome and predictors of restenosis after USG intraluminal approach for de novo long occlusive FP lesion were investigated. Among the study participants, 34% were female, 50% had diabetes mellitus, and 10% received hemodialysis. Lesion and chronic total occlusion (CTO) lengths were 222 ± 55 mm and 201 ± 55 mm, respectively. Procedural success was achieved in 72 lesions (99%). Distal puncture was performed in 7 limbs (10%). The proportion of within-CTO intraplaque, subintimal, and medial routes were 87 ± 21%, 9 ± 15%, and 4 ± 11%, respectively. Primary patency was 71% and 69% at 1 and 2 years. Multivariate analysis revealed that within-CTO intraplaque route proportion [hazard ratio (HR) 0.81; 95% confidence interval (CI) 0.67-0.98, p = 0.0339] and lesion length (HR 1.11; CI 1.00-1.22; p = 0.0447) were independent predictors of restenosis.USG intraluminal approach facilitated acquisition of within-CTO intraplaque route in long occlusive FP lesions and could improve clinical outcome.


Assuntos
Arteriopatias Oclusivas/cirurgia , Procedimentos Endovasculares/métodos , Artéria Femoral , Artéria Poplítea , Cirurgia Assistida por Computador/métodos , Ultrassonografia de Intervenção/métodos , Arteriopatias Oclusivas/diagnóstico , Arteriopatias Oclusivas/fisiopatologia , Feminino , Seguimentos , Humanos , Masculino , Estudos Retrospectivos , Resultado do Tratamento , Grau de Desobstrução Vascular
11.
Diagnostics (Basel) ; 10(11)2020 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-33171865

RESUMO

Non-alcoholic fatty liver disease (NAFLD) is now recognized as the most common chronic liver disease worldwide, along with the concurrent epidemics of metabolic syndrome and obesity. Patients with NAFLD have increased risks of end-stage liver disease, hepatocellular carcinoma, and liver-related mortality. However, the largest cause of death among patients with NAFLD is cardiovascular disease followed by extrahepatic malignancies, whereas liver-related mortality is only the third cause of death. Extrahepatic complications of NAFLD include chronic kidney disease, extrahepatic malignancies (such as colorectal cancer), psychological dysfunction, gastroesophageal reflux disease, obstructive sleep apnea syndrome, periodontitis, hypothyroidism, growth hormone deficiency, and polycystic ovarian syndrome. The objective of this narrative review was to summarize recent evidences about extrahepatic complications of NAFLD, with focus on the prevalent/incident risk of such diseases in patients with NAFLD. To date, an appropriate screening method for extrahepatic complications has not yet been determined. Collaborative care with respective experts seems to be necessary for patient management because extrahepatic complications can occur across multiple organs. Further studies are needed to reveal risk profiles at baseline and to determine an appropriate screening method for extrahepatic diseases.

12.
J Interv Cardiol ; 2020: 7342732, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32982609

RESUMO

OBJECTIVES: To compare feasibility and safety between ultrasound-guided and conventional distal transradial access (dTRA). BACKGROUND: Distal transradial access, a new technique for coronary angiography (CAG) and percutaneous coronary interventions (PCI), is safe and feasible and will become popular worldwide. Ultrasound-guided dTRA has been advocated to reduce failure rate and access-site complications. However, to date, the comparison of feasibility and safety between ultrasound-guided and conventional dTRA has not been reported. METHOD: Overall, 137 patients (144 procedures) who underwent CAG or PCI using dTRA between September 2018 and February 2019 were investigated. These patients were classified into two groups: C (dTRA with conventional punctures; 76 patients, 79 procedures) and U (dTRA with ultrasound-guided punctures; 61 patients, 65 procedures) groups. Successful procedural rate, procedural outcomes, and complication rate during hospital stays were compared between the two groups. RESULTS: The procedural success rate was significantly higher in the U group than in the C group (97% vs. 87%, P=0.0384). However, the rate of PCI, puncture time, total fluoroscopy time, the volume of contrast medium, the rate of access-site ecchymosis, and incidence of nerve disorder were similar between the two groups. Additionally, radial artery occlusion after the procedure did not occur in this study. CONCLUSION: The ultrasound-guided dTRA for CAG or PCI was associated with a lower failure rate than conventional dTRA. However, there were no significant differences in puncture time and complication rate between the two procedures.


Assuntos
Cateterismo Periférico/métodos , Angiografia Coronária , Intervenção Coronária Percutânea , Artéria Radial , Cirurgia Assistida por Computador/métodos , Ultrassonografia de Intervenção/métodos , Idoso , Angiografia Coronária/efeitos adversos , Angiografia Coronária/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Artéria Radial/diagnóstico por imagem , Artéria Radial/cirurgia , Resultado do Tratamento
14.
SAGE Open Med Case Rep ; 8: 2050313X20921081, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32577280

RESUMO

A 68-year-old man was scheduled to undergo percutaneous coronary intervention for in-stent total occlusion of the severely tortuous right coronary artery. Intravascular ultrasound revealed heavy in-stent calcification. Lesion atherectomy was required; however, severe proximal vessel tortuosity was detected. We introduced a 7-Fr guide-extension catheter beyond the severely tortuous part and performed rotational atherectomy with a 1.5 mm burr. However, the balloon could not expand; therefore, we changed to an orbital atherectomy system. Subsequently, the balloon successfully expanded, and intravascular ultrasound revealed an enlarged lumen. Severe proximal vessel tortuosity limits the use of atherectomy devices; however, a guide-extension catheter delivers the atherectomy device beyond the tortuosity. The delivery of the orbital atherectomy system inside the guide-extension catheter is easy due to its low profile; the debulking effect increases with the number of passes and rotational speed. This strategy is a useful option for treating severe calcified lesions with proximal vessel tortuosity.

15.
Int J Cardiovasc Imaging ; 36(10): 1811-1819, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32524242

RESUMO

We aimed to evaluate the additional debulking efficacy of low-speed rotational atherectomy (RA) after high-speed RA by using intravascular imaging. A total of 22 severe calcified coronary lesions in 19 patients (age, 74 ± 10 years; 74% male) were retrospectively analyzed. All of these lesions underwent RA under optical coherence tomography (OCT) or optical frequency domain imaging (OFDI) guidance. At first, we performed high-speed RA with 220,000 rpm until the reduction of rotational speed disappeared; then, low-speed RA with 120,000 rpm using the same burr size was performed. OCT or OFDI was performed after both high-speed and low-speed RAs, and the minimum lumen area were compared. The initial and final burr sizes of high-speed RA were 1.5 (1.5-1.75) and 1.75 (1.5-2.0) mm, respectively. The number of sessions, total duration time, and maximum decreased rotational speed during high-speed RA were 11 ± 5 times, 113 ± 47 s, and 4000 (3000-5000) rpm, respectively. During low-speed RA, the number of sessions, total duration time, and maximum reduction of rotational speed were 3 ± 1 times, 32 ± 11 s, and 1000 (0-2000) rpm, respectively. The minimum lumen area was similar between after high-speed and after low-speed RA [2.61 ± 1.03 mm2 (after high-speed RA) vs. 2.65 ± 1.00 mm2 (after low-speed RA); P = 0.91]. Additional low-speed RA immediately after sufficient debulking by high-speed RA was not associated with increased lumen enlargement. There was no clinical efficacy of low-speed RA after high-speed RA.


Assuntos
Angioplastia Coronária com Balão , Aterectomia Coronária , Doença da Artéria Coronariana/terapia , Calcificação Vascular/terapia , Idoso , Idoso de 80 Anos ou mais , Angioplastia Coronária com Balão/efeitos adversos , Aterectomia Coronária/efeitos adversos , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Tempo , Tomografia de Coerência Óptica , Resultado do Tratamento , Calcificação Vascular/diagnóstico por imagem
16.
Radiographics ; 40(3): 667-683, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32216704

RESUMO

Endoscopic US-guided biliary drainage (BD) is performed for various types of biliary obstruction and is mainly indicated for unsuccessful conventional transpapillary endoscopic retrograde cholangiodrainage. In endoscopic US BD, an extra-anatomic drainage route between the gastrointestinal (GI) tract and the biliary system is created with a covered metallic stent or plastic stent. Procedural types of endoscopic US BD include hepaticogastrostomy, hepaticojejunostomy (after gastrectomy), choledochoduodenostomy, hepaticoduodenostomy, and endoscopic US-guided gallbladder drainage. The technical and clinical success rates of endoscopic US BD are reported to be 94%-97% and 88%-100%, respectively. CT is crucial both in preprocedural assessment and postprocedural monitoring. CT is used to determine the indications for endoscopic US BD, which include the type of biliary obstruction, collateral vessels in the puncture route, ascites, the volume of the liver segment, the distribution of an intrahepatic tumor, and GI tract patency. After endoscopic US BD, common subclinical findings are a small amount of intraperitoneal gas, localized edematous change in the GI tract, a notch in the placed stent, and localized biliary dilatation caused by stent placement. Stent malfunction after endoscopic US BD is caused by impaction of debris and/or food, stent migration into the GI tract, or tumor overgrowth and/or hyperplasia. Complications that can occur include internal stent migration, intraperitoneal biloma, arterial bleeding or pseudoaneurysm, perforation of the GI tract, and portobiliary fistula. The incidence of clinical endoscopic US BD-related complications is 11%-23%. ©RSNA, 2020.


Assuntos
Colestase/diagnóstico por imagem , Colestase/cirurgia , Drenagem/métodos , Endoscopia Gastrointestinal/métodos , Tomografia Computadorizada por Raios X , Ultrassonografia de Intervenção , Colangiopancreatografia Retrógrada Endoscópica , Colestase/etiologia , Humanos , Complicações Pós-Operatórias/diagnóstico por imagem , Stents
17.
SAGE Open Med Case Rep ; 8: 2050313X20907825, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32110413

RESUMO

A 63 year-old woman with claudication underwent endovascular therapy for diffuse stenosis of the right superficial femoral artery in our hospital. We performed paclitaxel-coated balloon angioplasty using the IN.PACT™ Admiral™ and achieved acceptable results. After 42 days, we performed follow-up optical frequency domain imaging for the right superficial femoral artery lesion treated with paclitaxel-coated balloon and observed several high-intensity regions with attenuation on the lumen surface. Sustained drug availability is a notable characteristic of paclitaxel-coated balloon. To the best of our knowledge, this is the first report on the visualization of sustained drug retention on the lumen surface using follow-up optical frequency domain imaging after paclitaxel-coated balloon angioplasty in a human patient with superficial femoral artery disease.

18.
Ann Vasc Surg ; 66: 670.e9-670.e14, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32018022

RESUMO

Guide extension catheters have been available since 2015 for peripheral endovascular intervention. These devices are commonly used for active backup support. We successfully managed 2 cases of infrapopliteal arterial disease with the assistance of a guide extension catheter. In a patient with a posterior tibial artery occlusion, early elastic recoil occurred after balloon dilatation. We then deployed the guide extension catheter to maintain blood flow while ballooning for 15 min, resulting in good blood flow to the toes after device removal. Another patient had a severely calcified stenotic anterior tibial artery lesion. Although a guidewire could be advanced to the lesion, no device could be passed through the calcification. Using the guide extension catheter, we then safely delivered a 0.035-inch guidewire's tail to drill through the calcification. Thereafter, a balloon could be passed, and successful angioplasty was achieved. These cases illustrate the usefulness of a guide extension catheter in endovascular therapy of complex infrapopliteal lesions.


Assuntos
Procedimentos Endovasculares/instrumentação , Doença Arterial Periférica/terapia , Artéria Poplítea , Dispositivos de Acesso Vascular , Calcificação Vascular/terapia , Idoso de 80 Anos ou mais , Desenho de Equipamento , Feminino , Humanos , Masculino , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/fisiopatologia , Artéria Poplítea/diagnóstico por imagem , Artéria Poplítea/fisiopatologia , Resultado do Tratamento , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/fisiopatologia , Grau de Desobstrução Vascular
19.
J Vasc Interv Radiol ; 31(1): 141-149, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31542277

RESUMO

PURPOSE: To determine the clinical impact and predictors of slow flow after endovascular treatment (EVT) using the Crosser catheter for debulking infrapopliteal lesions associated with critical limb ischemia. MATERIALS AND METHODS: This retrospective study included 65 patients with critical limb ischemia (70 limbs, 90 infrapopliteal lesions), who underwent EVT using the Crosser catheter between November 2011 and February 2017. The Crosser catheter was used when the balloon catheter could not be passed through the lesion or could not be dilated sufficiently. Slow flow was evaluated after atherectomy using Crosser and was defined as delayed antegrade flow to the foot (total number of cine frames >35). RESULTS: Following atherectomy, slow flow developed in 37 infrapopliteal lesions (41.1%). Despite secondary treatment, slow flow persisted in 29 of 37 lesions (78%). After atherectomy using the Crosser catheter, the balloon could be passed through the lesion in all cases. The wound healing rate at 1 year after EVT (overall, 67.8%) was significantly poorer in the presence of slow flow (rate with vs. without slow flow, 45.3% vs. 84.4%, respectively; P = .006), especially among patients with stage ≥3 baseline wound, ischemia, and foot infection. The active length of the Crosser catheter was a predictor of slow flow (odds ratio, 1.05; 95% confidence interval, 1.03-1.08; P < .001), with an optimal cutoff of 100 mm. CONCLUSIONS: Slow flow is associated with a poorer wound healing rate at 1 year, especially for patients with severe baseline ischemia. To reduce the risk of slow flow, the active length of the Crosser catheter should be kept at <100 mm.


Assuntos
Angioplastia com Balão , Aterectomia/instrumentação , Isquemia/terapia , Doença Arterial Periférica/terapia , Artéria Poplítea/fisiopatologia , Dispositivos de Acesso Vascular , Calcificação Vascular/terapia , Idoso , Angioplastia com Balão/efeitos adversos , Aterectomia/efeitos adversos , Velocidade do Fluxo Sanguíneo , Estado Terminal , Bases de Dados Factuais , Desenho de Equipamento , Feminino , Humanos , Isquemia/diagnóstico por imagem , Isquemia/fisiopatologia , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/fisiopatologia , Artéria Poplítea/diagnóstico por imagem , Fluxo Sanguíneo Regional , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/fisiopatologia , Grau de Desobstrução Vascular , Cicatrização
20.
Catheter Cardiovasc Interv ; 96(3): E355-E359, 2020 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-31815366

RESUMO

OBJECTIVE: This retrospective study assessed the safety and efficacy of the ARAHKEY (ARterial sealing with Additional Hemostatic device Kissing with Extravascular and suture-based device deeplY) technique during transcatheter aortic valve replacement (TAVR). BACKGROUND: Access site complications are still a major issue to be solved during TAVR using a large caliber sheath. METHODS: From February 2014 to June 2019, a total of 302 patients underwent TAVR in our hospital. Twenty-five patients (10.2% of patients who underwent percutaneous transfemoral TAVR [n = 246]) were treated using the ARAHKEY technique, which is the additional use of Exoseal for the common femoral artery puncture site when hemostasis was not achieved with ProGlide alone. RESULTS: Complete hemostasis was achieved in all patients (100%). The mean procedural time for hemostasis was 9.8 ± 4.5 min. No complications, including recurrent bleeding, infection, and late acquired hematoma, were observed in this study cohort. CONCLUSION: The ARAHKEY technique is a safe method and should be considered as a secondary option when hemostasis is not achieved with ProGlide during TAVR.


Assuntos
Valva Aórtica/cirurgia , Perda Sanguínea Cirúrgica/prevenção & controle , Cateterismo Periférico/efeitos adversos , Artéria Femoral , Técnicas Hemostáticas/instrumentação , Técnicas de Sutura/instrumentação , Substituição da Valva Aórtica Transcateter/efeitos adversos , Dispositivos de Oclusão Vascular , Idoso de 80 Anos ou mais , Desenho de Equipamento , Feminino , Técnicas Hemostáticas/efeitos adversos , Humanos , Masculino , Punções , Estudos Retrospectivos , Técnicas de Sutura/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA