1.
Adv Mater
; 25(1): 96-102, 2013 Jan 04.
Artigo
em Inglês
| MEDLINE
| ID: mdl-23109104
RESUMO
Microvascular multinozzle arrays are designed and fabricated for high-throughput printing of functional materials. Ink-flow uniformity within these multigeneration, bifurcating microchannel arrays is characterized by computer modeling and microscopic particle image velocimetry (micro-PIV) measurements. Both single and dual multinozzle printheads are produced to enable rapid printing of multilayered periodic structures over large areas (≈1 m(2)).