Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Eur J Clin Invest ; 49(7): e13120, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31002171

RESUMO

BACKGROUND: Disturbances in adipose tissue glucose uptake may play a role in the pathogenesis of type 2 diabetes, yet its examination by 2-deoxy-2-[18 F]fluorodeoxyglucose ([18 F]FDG) PET/CT is challenged by relatively low uptake kinetics. We tested the hypothesis that performing [18 F]FDG PET/CT during a hypoglycaemic clamp would improve adipose tissue tracer uptake to allow specific comparison of adipose tissue glucose handling between people with or without type 2 diabetes. DESIGN: We enrolled participants with or without diabetes who were at least overweight, to undergo a hyperinsulinaemic hypoglycaemic clamp or a hyperinsulinaemic euglycaemic clamp (n = 5 per group). Tracer uptake was quantified using [18 F]FDG PET/CT. RESULTS: Hypoglycaemic clamping increased [18 F]FDG uptake in visceral adipose tissue of healthy participants (P = 0.002). During hypoglycaemia, glucose uptake in visceral adipose tissue of type 2 diabetic participants was lower as compared to healthy participants (P < 0.0005). No significant differences were observed in skeletal muscle, liver or pancreas. CONCLUSIONS: The present findings indicate that [18 F]FDG PET/CT during a hypoglycaemic clamp provides a promising new research tool to evaluate adipose tissue glucose metabolism. Using this method, we observed a specific impairment in visceral adipose tissue [18 F]FDG uptake in type 2 diabetes, suggesting a previously underestimated role for adipose tissue glucose handling in type 2 diabetes.


Assuntos
Tecido Adiposo/metabolismo , Hipoglicemia/diagnóstico por imagem , Tecido Adiposo/diagnóstico por imagem , Adulto , Glicemia/metabolismo , Estudos de Casos e Controles , Diabetes Mellitus Tipo 2/diagnóstico por imagem , Diabetes Mellitus Tipo 2/tratamento farmacológico , Diabetes Mellitus Tipo 2/metabolismo , Feminino , Fluordesoxiglucose F18/farmacocinética , Glucose/administração & dosagem , Glucose/farmacocinética , Humanos , Hipoglicemia/metabolismo , Hipoglicemiantes/administração & dosagem , Masculino , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Compostos Radiofarmacêuticos/farmacocinética , Edulcorantes/administração & dosagem , Edulcorantes/farmacocinética
2.
Clin Nucl Med ; 38(6): e261-2, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22996248

RESUMO

Neurolymphomatosis is defined as infiltration of the nervous system by hematological malignancy and is difficult to diagnose. We report a case of a 57-year-old man, treated for small B-cell non-Hodgkin lymphoma, presenting with sensorimotor impairment of the lower limbs, which started 6 years after diagnosis. He was treated with chemotherapy, after which, the symptoms disappeared. After 7 months, he developed sensorimotor impairment of both upper limbs. MRI of the brachial plexus showed no abnormalities. F-FDG PET-CT showed increased uptake at the brachial plexus and nerves, suggesting neurolymphomatosis. Confirmatory biopsy revealed conversion of the malignancy to diffuse large B-cell lymphoma.


Assuntos
Fluordesoxiglucose F18 , Linfoma de Células B/diagnóstico , Linfoma de Células B/patologia , Imagem Multimodal , Neoplasias do Sistema Nervoso/diagnóstico , Neoplasias do Sistema Nervoso/patologia , Biópsia por Agulha Fina , Humanos , Masculino , Pessoa de Meia-Idade , Cintilografia
3.
Nucl Med Commun ; 33(9): 907-16, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22714006

RESUMO

Neurolymphomatosis (NL) is a rare clinical entity that is defined as infiltration of the nervous system by a known or unknown haematological malignancy and is difficult to diagnose. Fluorine-18 fluorodeoxyglucose (18F-FDG) PET imaging is increasingly being used in haematological malignancies. This article focus on the role of 18F-FDG PET in the diagnosis and management of NL by presenting a review of cases described in the literature. Reports on NL that used PET with or without computed tomography (CT) as a diagnostic modality were extracted from Medline and evaluated. A total of 58 patients described in 49 case reports on NL were found. In 36 distinctive patients 18F-FDG PET with or without CT was used as a diagnostic modality. In 91% of patients PET showed uptake in various structures in the central or peripheral nervous system, suggesting involvement of lymphoma. Predilection localizations were the brachial and lumbar plexuses, along the course of peripheral nerves of the extremities, and the trigeminal nerve root. MRI, cerebrospinal fluid or bone marrow analysis were frequently negative. In the cases described in the literature 18F-FDG PET assisted in diagnosing NL by providing a whole-body evaluation, showing frequent uptake in affected nervous structures and supported disease management by defining a target for biopsy, monitoring progression and evaluating response to treatment. As other diagnostic methods may be negative, the importance of PET-CT is increasing in the diagnosis and management of this rare clinical entity.


Assuntos
Neoplasias Hematológicas/patologia , Neoplasias do Sistema Nervoso/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Fluordesoxiglucose F18 , Humanos , Neoplasias do Sistema Nervoso/patologia
4.
J Cardiovasc Magn Reson ; 9(3): 557-63, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17365235

RESUMO

The aim was to validate a magnetic resonance high-resolution, phase-contrast sequence for quantifying flow in small and large vessels and to demonstrate its feasibility to measure flow in coronary artery bypass grafts. A breathhold, echo planar imaging (EPI) sequence was developed and validated in a flow phantom using a fast field echo (FFE) sequence as reference. In 17 volunteers aortic flow was measured using both sequences. In 5 patients flow in the left internal mammary artery (LIMA) and aorta was measured at rest and during adenosine stress, and coronary flow reserve (CFR) was calculated; in 7 patients, vein graft flow velocity was measured. In the flow phantom measurements, the EPI sequence yielded an excellent correlation with the FFE sequence (r = 0.99; p < 0.001 for all parameters). In healthy volunteers, aortic volume flow correlated well (r = 0.88; p < 0.01), with a minor overestimation. It was feasible to measure flow velocity in the LIMA and vein grafts of the 12 patients. The high-resolution, breathhold cardiovascular magnetic resonance velocity-encoded sequence correlated well with a free-breathing, FFE sequence in a flow phantom and in the aortae of healthy volunteers. Using the EPI sequence, it is feasible to measure flow velocity in both LIMA and vein grafts, and in the aorta.


Assuntos
Aorta Torácica/fisiologia , Ponte de Artéria Coronária , Imagem Ecoplanar/métodos , Artéria Torácica Interna/fisiologia , Adulto , Idoso , Velocidade do Fluxo Sanguíneo , Angiografia Coronária , Estudos de Viabilidade , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas
5.
Eur J Echocardiogr ; 7(4): 308-14, 2006 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16098814

RESUMO

AIMS: To compare multidetector row computed tomography (MDCT) global and regional left ventricular (LV) function assessment with echocardiography and cardiovascular magnetic resonance (CMR). METHODS AND RESULTS: In 25 patients, who were referred for noninvasive angiography with 16-detector row CT, LV function assessment was also performed. A subsequent echocardiogram was performed, and in a subgroup of patients, CMR examination was completed to evaluate LV function. For global function assessment, the LV ejection fraction (LVEF) was calculated. Regional LV function was scored using a 17-segment model and a 4-point scoring system. MDCT agreed well with echocardiography for the assessment of LVEF (r=0.96; bias 0.54%; p<0.0001) and regional LV function (kappa=0.78). Eight patients had no contra-indications and gave informed consent for CMR examination. A fair correlation between MDCT and CMR was demonstrated in the assessment of LVEF (r=0.86; bias -1.5%; p<0.01). Regional LV function agreement between MDCT and CMR was good (kappa=0.86). CONCLUSION: MDCT agreed well with both echocardiography and CMR in the assessment of global and regional LV function. Global and regional LV function may accurately be evaluated by 16-detector row CT, and can be added to a routine CT image analysis protocol without need for additional contrast or imaging time.


Assuntos
Ecocardiografia , Imagem Cinética por Ressonância Magnética , Volume Sistólico/fisiologia , Tomografia Computadorizada por Raios X/métodos , Função Ventricular Esquerda/fisiologia , Idoso , Doença das Coronárias/fisiopatologia , Feminino , Humanos , Masculino
6.
Am Heart J ; 150(4): 775-81, 2005 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16209981

RESUMO

BACKGROUND: Multidetector-row computed tomography (MDCT) is a versatile modality to evaluate stenoses in native coronary arteries and bypass grafts. Acquired MDCT data can additionally be used to assess left ventricular ejection fraction (LVEF). The purpose was to use MDCT for the assessment of bypass graft and coronary artery disease combined with evaluation of LVEF. METHODS: Twenty-five patients underwent 16-detector-row CT examination and coronary angiography. Bypass grafts and nongrafted coronary artery segments at MDCT were evaluated on eligibility, patency, and > or = 50% stenosis. The MDCT data set was used to calculate LVEF and was divided into patients with no/subendocardial/transmural myocardial infarctions (MIs). RESULTS: Ninety vessels were evaluated: 14 arterial grafts/53 vein grafts/23 nongrafted vessels. Of 225 segments, 17 were ineligible for evaluation because of metal clips. With MDCT, patency in segments of arterial grafts/vein grafts/nongrafted vessels could be evaluated with high accuracy in 100%/100%/97% of segments. In arterial grafts, stenoses > or = 50% did not occur at angiography, which was for all eligible segments correctly diagnosed at MDCT. Stenosis > or = 50% could be correctly detected by MDCT with a sensitivity/specificity of 100%/94% for vein grafts and 100%/89% for nongrafted vessels. Negative predictive value was 100% for vein grafts and nongrafted vessels. In patients with transmural MI, MDCT revealed a significant lower LVEF as compared with patients without or with subendocardial MI (P < .05). CONCLUSION: Comprehensive assessment of bypass grafts, nongrafted vessels, and LVEF is feasible with MDCT. Owing to the high negative predictive value this noninvasive approach may be used as gatekeeper before coronary angiography.


Assuntos
Ponte de Artéria Coronária , Estenose Coronária/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Idoso , Angiografia Coronária , Estenose Coronária/fisiopatologia , Feminino , Humanos , Masculino , Volume Sistólico , Tomografia Computadorizada por Raios X/métodos
7.
J Cardiovasc Magn Reson ; 7(4): 631-7, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16136852

RESUMO

Cardiovascular magnetic resonance (CMR) with flow velocity mapping has emerged as a noninvasive method to measure flow in saphenous vein coronary artery bypass grafts. The aim of the current study was to retrospectively test two previously described analysis methods on a large CMR data set and to compare their diagnostic accuracy in detecting diseased vein grafts. In 125 vein grafts of 68 patients, volume flow parameters (volume flow, systolic and diastolic peak flow, diastolic-to-systolic flow ratio at rest and during adenosine stress, and flow reserve) were derived from the velocity maps. Method 1 implemented basal flow < 20 ml/min or flow reserve < 2, yielding a sensitivity and specificity of 70% and 38% in the detection of a diseased graft or recipient vessel. Method 2 used receiver operating characteristic (ROC) curve analysis and implemented all significant volume flow parameters in a logistic regression model, yielding a sensitivity of 74% with a specificity of 68% in the detection of a diseased graft or recipient vessel. Evaluating single and sequential grafts separately, this method yielded a sensitivity and specificity of 79% and 87% for single grafts, and 62% and 94% for sequential grafts in the detection of > or = 50% stenosis in grafts or recipient vessels. Cut-off values were formulated for the respective volume flow parameters, which maximally separate grafts with and without > or = 50% stenosis. Using ROC curve analysis with logistic regression the specificity of the analysis method improved considerably. For the current data set the best results were acquired when single and sequential grafts were separately analyzed.


Assuntos
Ponte de Artéria Coronária , Circulação Coronária , Imageamento por Ressonância Magnética , Veia Safena/fisiopatologia , Veia Safena/transplante , Idoso , Algoritmos , Análise de Variância , Velocidade do Fluxo Sanguíneo , Estenose Coronária/fisiopatologia , Estenose Coronária/cirurgia , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Contração Miocárdica , Infarto do Miocárdio/fisiopatologia , Infarto do Miocárdio/cirurgia , Valor Preditivo dos Testes , Curva ROC , Estudos Retrospectivos , Veia Safena/patologia , Resultado do Tratamento
8.
J Nucl Cardiol ; 12(5): 545-52, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16171714

RESUMO

BACKGROUND: Coronary angiography is considered the gold standard in evaluating vein graft disease; however, angiography does not allow assessment of hemodynamic consequences of lesions. In this study hemodynamic consequences of significant stenoses in vein grafts were evaluated by Doppler velocity assessment, and results were compared with single photon emission computed tomography (SPECT) perfusion imaging. METHODS AND RESULTS: Angiography was performed in 58 patients after coronary artery bypass grafting because of recurrent chest pain. During the procedure, Doppler velocity measurements were acquired before and after administration of adenosine. Of 58 patients (with 78 vein grafts), 20 patients (with 24 vein grafts) underwent SPECT perfusion imaging. Grafts were divided into those with nonsignificant percent diameter stenosis (< 50%) (n = 49) and those with significant percent diameter stenosis (> or =50%) (n = 29). When a cutoff value for coronary flow velocity reserve (CFVR) of 1.8 was applied, modest agreement (69%, kappa = 0.25, P < .05) between CFVR and angiography was shown. Agreement between SPECT and angiography was also modest (63%, kappa = 0.28, P = not significant). SPECT and CFVR provided comparable information in 20 of 24 grafts with available SPECT, illustrating good agreement (83%, kappa = 0.61, P = .001). CONCLUSIONS: Significant stenoses in vein grafts require further exploration to assess their hemodynamic significance. The Doppler velocity results agreed better with SPECT perfusion imaging than with percent diameter stenosis in the evaluation of vein graft function.


Assuntos
Angiografia Coronária/estatística & dados numéricos , Ponte de Artéria Coronária/estatística & dados numéricos , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/epidemiologia , Fluxometria por Laser-Doppler/estatística & dados numéricos , Medição de Risco/métodos , Tomografia Computadorizada de Emissão de Fóton Único/estatística & dados numéricos , Idoso , Velocidade do Fluxo Sanguíneo , Doença da Artéria Coronariana/cirurgia , Feminino , Humanos , Incidência , Masculino , Reprodutibilidade dos Testes , Fatores de Risco , Veia Safena/diagnóstico por imagem , Veia Safena/transplante , Sensibilidade e Especificidade , Ultrassonografia
9.
Am J Cardiol ; 95(5): 571-4, 2005 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-15721093

RESUMO

In recent years, multislice computed tomography (MSCT) has been demonstrated to be a feasible imaging modality for noninvasive coronary angiography and left ventricular function analysis. The present study evaluated overall performance of 16-slice MSCT in the detection of significant coronary artery disease, stent, or bypass graft stenosis in combination with global left ventricular function analysis. Forty-five patients underwent 16-slice MSCT. Multislice computed tomograms were used to evaluate the presence of significant coronary artery stenoses (>/=50% decrease in luminal diameter) in native coronary segments, bypass grafts, and coronary stents and were compared with conventional coronary angiograms. In addition, left ventricular ejection fraction was calculated and compared with 2-dimensional echocardiography. MSCT was performed successfully in all patients. A close correlation between MSCT and 2-dimensional echocardiography was demonstrated for the assessment of left ventricular ejection fraction (y = 0.93x +3.33, r = 0.96, p <0.001). A total of 298 of native coronary artery segments (94%) were evaluated with MSCT, whereas 81 of 94 grafts (85%) and 41 of 52 coronary stents (79%) were also evaluated. For all segments, overall sensitivity, specificity, and positive and negative predictive values were 85%, 89%, 71%, and 95%, respectively. In conclusion, 16-slice MSCT is a feasible modality for noninvasive evaluation and exclusion of coronary artery disease in patients who present with chest pain.


Assuntos
Doença das Coronárias/diagnóstico por imagem , Iohexol/análogos & derivados , Tomografia Computadorizada por Raios X/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Meios de Contraste , Angiografia Coronária , Ponte de Artéria Coronária , Estenose Coronária/diagnóstico por imagem , Ecocardiografia , Feminino , Oclusão de Enxerto Vascular/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Sensibilidade e Especificidade , Stents
10.
Diabetes Care ; 27(12): 2905-10, 2004 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-15562205

RESUMO

OBJECTIVE: Early identification of coronary artery disease (CAD) in patients with diabetes is important because these patients are at increased risk for CAD and have worse outcome than nondiabetic patients after CAD is diagnosed. Recently, noninvasive coronary angiography and assessment of left ventricular function has been demonstrated with multislice computed tomography (MSCT). The purpose of the present study was to validate this approach in patients with type 2 diabetes. RESEARCH DESIGN AND METHODS: MSCT was performed in 30 patients with confirmed type 2 diabetes. From the MSCT images, coronary artery stenoses (> or =50% luminal narrowing) and left ventricular function (left ventricular ejection fraction, regional wall motion) were evaluated and compared with results of conventional angiography and two-dimensional echocardiography. RESULTS: Two hundred twenty of 256 coronary artery segments (86%) were interpretable with MSCT. In these segments, sensitivity and specificity for detection of coronary artery stenoses were 95%. Including the uninterpretable segments, sensitivity and specificity were 81 and 82%, respectively. Bland-Altman analysis in the comparison of left ventricular ejection fractions demonstrated a mean difference of -0.48 +/- 3.8% for MSCT and echocardiography, which was not significantly different from 0. Agreement between the two modalities for assessment of regional contractile function was excellent (91%, kappa statistic 0.81). CONCLUSIONS: Accurate noninvasive evaluation of both the coronary arteries and left ventricular function with MSCT is feasible in patients with type 2 diabetes. This noninvasive approach may allow optimal identification of high-risk patients.


Assuntos
Doença das Coronárias/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Diabetes Mellitus Tipo 2/diagnóstico por imagem , Angiopatias Diabéticas/diagnóstico por imagem , Tomografia Computadorizada Espiral/métodos , Função Ventricular Esquerda/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
11.
J Am Coll Cardiol ; 44(9): 1877-82, 2004 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-15519022

RESUMO

OBJECTIVES: This study was designed to perform a head-to-head comparison between single-photon emission computed tomography (SPECT) and cardiovascular magnetic resonance (CMR) to evaluate hemodynamic significance of angiographic findings in bypass grafts. BACKGROUND: The hemodynamic significance of a bypass graft stenosis may not always accurately be determined from the coronary angiogram. A variety of diagnostic tests (invasive or noninvasive) can further characterize the hemodynamic consequence of a lesion. METHODS: Fifty-seven arterial and vein grafts in 25 patients were evaluated by angiography, SPECT perfusion imaging, and coronary flow velocity reserve determination by CMR. Based on angiography and SPECT, four different groups could be identified: 1) no significant stenosis (<50%), normal perfusion; 2) significant stenosis (>/=50%), abnormal perfusion; 3) significant stenosis, normal perfusion (no hemodynamic significance); and 4) no significant stenosis, abnormal perfusion (suggesting microvascular disease). RESULTS: A complete evaluation was obtained in 46 grafts. Single-photon emission computed tomography and CMR provided similar information in 37 of 46 grafts (80%), illustrating good agreement (kappa = 0.61, p < 0.001). Eight grafts perfused a territory with scar tissue. When agreement between SPECT and CMR was restricted to grafts without scar tissue, it improved to 84% (kappa = 0.68). Integration of angiography with SPECT categorized 14 lesions in group 1, 23 in group 2, 6 in group 3, and 3 in group 4. Single-photon emission computed tomography and CMR agreement per group was 86%, 78%, 100%, and 33%, respectively. CONCLUSIONS: Head-to-head comparison showed good agreement between SPECT and CMR for functional evaluation of bypass grafts. Cardiovascular magnetic resonance may offer an alternative method to SPECT for functional characterization of angiographic lesions.


Assuntos
Angiografia Coronária , Ponte de Artéria Coronária , Estenose Coronária/diagnóstico , Estenose Coronária/cirurgia , Imageamento por Ressonância Magnética , Tomografia Computadorizada de Emissão de Fóton Único , Idoso , Artérias/diagnóstico por imagem , Artérias/fisiopatologia , Artérias/cirurgia , Velocidade do Fluxo Sanguíneo/fisiologia , Estenose Coronária/fisiopatologia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/fisiopatologia , Vasos Coronários/cirurgia , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Intensificação de Imagem Radiográfica , Volume Sistólico/fisiologia , Resultado do Tratamento
12.
Radiology ; 232(3): 915-20, 2004 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-15273340

RESUMO

Forty-nine patients with previous bypass surgery underwent coronary angiography and cardiovascular magnetic resonance (MR) imaging of single-vein bypass grafts. Volume flow and velocity analyses were performed and compared on MR velocity maps. Bland-Altman analysis showed close agreement between the two types of analysis. Comparison of areas under the receiver operating characteristic curve revealed no significant differences between the analyses for detection of stenoses of 70% or greater. Diagnostic accuracy for volume flow and velocity parameters was 92% and 93%, respectively. Velocity analysis appears to be the preferred method, because it is less time-consuming and has a similar diagnostic accuracy to volume flow analysis.


Assuntos
Ponte de Artéria Coronária , Circulação Coronária , Imageamento por Ressonância Magnética , Adulto , Idoso , Reestenose Coronária/diagnóstico , Feminino , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Fluxo Sanguíneo Regional , Reprodutibilidade dos Testes , Veias/fisiopatologia , Veias/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA