Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
1.
Pathogens ; 13(3)2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38535560

RESUMO

It is controversial how useful bioassays are for identifying the in vivo toxicity of hazardous environmental exposures. In this study, fruiting bodies of forest mushrooms (n = 46), indoor mold colonies (n = 412), fungal secondary metabolites (n = 18), xenobiotic chemicals such as biocides and detergents (n = 6), and methanol extracts of indoor dusts from urban buildings (n = 26) were screened with two different bioactivity assays: boar sperm motility inhibition (BSMI) and inhibition of cell proliferation (ICP) tests. For the forest mushrooms, the toxicity testing result was positive for 100% of poisonous-classified species, 69% of non-edible-classified species, and 18% of edible-classified species. Colonies of 21 isolates of Ascomycota mold fungal species previously isolated from water-damaged buildings proved to be toxic in the tests. Out of the fungal metabolites and xenobiotic chemicals, 94% and 100% were toxic, respectively. Out of the indoor dusts from moldy-classified houses (n = 12) and from dry, mold-free houses (n = 14), 50% and 57% were toxic, respectively. The bioassay tests, however, could not differentiate the samples from indoor dusts of moldy-classified buildings from those from the mold-free buildings. Xenobiotic chemicals and indoor dusts were more toxic in the BSMI assay than in the ICP assay, whereas the opposite results were obtained with the Ascomycota mold colonies and fungal secondary metabolites. The tests recognized unknown methanol-soluble thermoresistant substances in indoor settled dusts. Toxic indoor dusts may indicate a harmful exposure, regardless of whether the toxicity is due to xenobiotic chemicals or microbial metabolites.

2.
Pathogens ; 12(2)2023 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-36839611

RESUMO

Sport facilities represent extreme indoor environments due to intense cleaning and disinfection. The aim of this study was to describe the composition of the cultivated microbiota in dust samples collected in sport facilities during the COVID-19 pandemic. A dust sample is defined as the airborne dust sedimented on 0.02 m2 within 28 d. The results show that the microbial viable counts in samples of airborne dust (n = 9) collected from seven Finnish sport facilities during the pandemic contained a high proportion of pathogenic filamentous fungi and a low proportion of bacteria. The microbial viable counts were between 14 CFU and 189 CFU per dust sample. In seven samples from sport facilities, 20-85% of the microbial viable counts were fungi. Out of 123 fungal colonies, 47 colonies belonged to the potentially pathogenic sections of Aspergillus (Sections Fumigati, Nigri, and Flavi). Representatives of each section were identified as Aspergillus fumigatus, A. flavus, A. niger and A. tubingensis. Six colonies belonged to the genus Paecilomyces. In six samples of dust, a high proportion (50-100%) of the total fungal viable counts consisted of these potentially pathogenic fungi. A total of 70 isolates were considered less likely to be pathogenic, and were identified as Aspergillus section Nidulantes, Chaetomium cochliodes and Penicillium sp. In the rural (n = 2) and urban (n = 7) control dust samples, the microbial viable counts were >2000 CFU and between 44 CFU and 215 CFU, respectively, and consisted mainly of bacteria. The low proportion of bacteria and the high proportion of stress tolerant, potentially pathogenic fungi in the dust samples from sport facilities may reflect the influence of disinfection on microbial communities.

3.
Pathogens ; 11(10)2022 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-36297230

RESUMO

Viable airborne pathogenic fungi represent a potential health hazard when exposing vulnerable persons in quantities exceeding their resilience. In this study, 284 indoor fungal isolates from a strain collection of indoor fungi were screened for pathogenic potential through the ability to grow in neutral pH at 37 °C and 30 °C. The isolates were collected from 20 locations including 14 problematic and 6 non-problematic ordinary buildings. Out of the screened isolates, 170 isolates were unable to grow at 37 °C, whereas 67 isolates growing at pH 7.2 at 37 °C were considered as potential opportunistic pathogens. Forty-seven isolates growing at 30 °C but not at 37 °C were considered as less likely pathogens. Out of these categories, 33 and 33 strains, respectively, were identified to the species level. The problematic buildings included known opportunistic pathogens: Aspergillus calidoustus, Trichoderma longibrachiatum, Rhizopus arrhizus and Paecilomyces variotii, as well as less likely pathogens: Aspergillus versicolor, Chaetomium cochliodes, Chaetomium globosum and Chaetomium rectangulare. Opportunistic pathogens such as Aspergillus flavus, Aspergillus fumigatus, Aspergillus niger and Aspergillus tubingensis and less likely pathogens such as Aspergillus westerdijkiae, Chaetomium globosum and Dichotomopilus finlandicus were isolated both from ordinary and from problematic buildings. Aspergillus was the dominant, most diverse genus found during screening for potentially pathogenic isolates in the indoor strain collection. Studies on Aspergillus niger and Aspergillus calidodoustus revealed that tolerance to cleaning chemicals may contribute to the adaptation of Aspergillus species to indoor environments.

4.
Pathogens ; 10(9)2021 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-34578165

RESUMO

The genus Chaetomium is a frequently occurring fungal taxon world-wide. Chaetomium and Chaetomium-like species occur in indoor environments, where they can degrade cellulose-based building materials, thereby causing structural damage. Furthermore, several species of this genus may also cause adverse effects on human health. The aims of this research were to identify Chaetomium and Chaetomium-like strains isolated from indoor environments in Hungary and Finland, two geographically distant regions of Europe with drier and wetter continental climates, respectively, and to study their morphological and physiological properties, as well as their extracellular enzyme activities, thereby comparing the Chaetomium and Chaetomium-like species isolated from these two different regions of Europe and their properties. Chaetomium and Chaetomium-like strains were isolated from flats and offices in Hungary, as well as from schools, flats, and offices in Finland. Fragments of the translation elongation factor 1α (tef1α), the second largest subunit of RNA polymerase II (rpb2) and ß-tubulin (tub2) genes, as well as the internal transcribed spacer (ITS) region of the ribosomal RNA gene cluster were sequenced, and phylogenetic analysis of the sequences performed. Morphological examinations were performed by stereomicroscopy and scanning electron microscopy. Thirty-one Chaetomium sp. strains (15 from Hungary and 16 from Finland) were examined during the study. The most abundant species was Ch. globosum in both countries. In Hungary, 13 strains were identified as Ch. globosum, 1 as Ch. cochliodes, and 1 as Ch. interruptum. In Finland, 10 strains were Ch. globosum, 2 strains were Ch. cochliodes, 2 were Ch. rectangulare, and 2 isolates (SZMC 26527, SZMC 26529) proved to be representatives of a yet undescribed phylogenetic species from the closely related genus Dichotomopilus, which we formally describe here as the new species Dichotomopilus finlandicus. Growth of the isolates was examined at different temperatures (4, 15, 20, 25, 30, 37, 35, 40, and 45 °C), while their extracellular enzyme production was determined spectrophotometrically.

5.
Pathogens ; 10(7)2021 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-34357993

RESUMO

Occupants may complain about indoor air quality in closed spaces where the officially approved standard methods for indoor air quality risk assessment fail to reveal the cause of the problem. This study describes a rare genus not previously detected in Finnish buildings, Acrostalagmus, and its species A. luteoalbus as the major constituents of the mixed microbiota in the wet cork liner from an outdoor wall. Representatives of the genus were also present in the settled dust in offices where occupants suffered from symptoms related to the indoor air. One strain, POB8, was identified as A. luteoalbus by ITS sequencing. The strain produced the immunosuppressive and cytotoxic melinacidins II, III, and IV, as evidenced by mass spectrometry analysis. In addition, the classical toxigenic species indicating water damage, mycoparasitic Trichoderma, Aspergillus section Versicolores, Aspergillus section Circumdati, Aspergillus section Nigri, and Chaetomium spp., were detected in the wet outdoor wall and settled dust from the problematic rooms. The offices exhibited no visible signs of microbial growth, and the airborne load of microbial conidia was too low to explain the reported symptoms. In conclusion, we suggest the possible migration of microbial bioactive metabolites from the wet outdoor wall into indoor spaces as a plausible explanation for the reported complaints.

6.
Indoor Air ; 31(5): 1563-1576, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33939214

RESUMO

The emissions of volatile organic compounds (VOCs) from building materials may significantly contribute to indoor air pollution, and VOCs have been associated with odor annoyance and adverse health effects. Wood materials together with coatings are commonly used indoors for furniture and large surfaces such as walls, floors, and ceilings. This leads to high surface-to-volume ratios, and therefore, these materials may participate remarkably to the VOC levels of indoor environment. We studied emissions of VOCs and carbonyl compounds from pinewood (Pinus sylvestris) boards of 10% and 16% moisture contents (MC) with three paints using small-scale test chambers (27 L). The emissions from uncoated pinewood and paints (on a glass substrate) were tested as references. The 28-day experiment showed that the VOC emissions from uncoated pinewood were lower from sample with 16% MC. Painted pinewood samples showed lower emissions compared to paints on glass substrate. Additionally, paints on 16% MC pinewood exhibited lower emissions than on drier 10% MC wood. The emissions from painted pinewood samples were dominated by paint-based compounds, but the share of wood-based compounds increased over time. However, we noticed differences between the paints, and wood-based emissions were clearly higher with the most permeable paint.


Assuntos
Poluição do Ar em Ambientes Fechados , Pintura , Compostos Orgânicos Voláteis/análise , Madeira , Materiais de Construção , Monitoramento Ambiental , Decoração de Interiores e Mobiliário , Pinus sylvestris
7.
Microorganisms ; 8(12)2020 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-33297485

RESUMO

The secretion of metabolites in guttation droplets by indoor moulds is not well documented. This study demonstrates the guttation of metabolites by actively growing common indoor moulds. Old and fresh biomasses of indoor isolates of Aspergillus versicolor, Chaetomium globosum, Penicillium expansum, Trichoderma atroviride, T. trixiae, Rhizopus sp. and Stachybotrys sp. were compared. Metabolic activity indicated by viability staining and guttation of liquid droplets detected in young (<3 weeks old) biomass were absent in old (>6 months old) cultures consisting of dehydrated hyphae and dormant conidia. Fresh (<3 weeks old) biomasses were toxic more than 10 times towards mammalian cell lines (PK-15 and MNA) compared to the old dormant, dry biomasses, when calculated per biomass wet weight and per conidial particle. Surfactant activity was emitted in exudates from fresh biomass of T. atroviride, Rhizopus sp. and Stachybotrys sp. Surfactant activity was also provoked by fresh conidia from T. atroviride and Stachybotrys sp. strains. Water repealing substances were emitted by cultures of P. expansum, T. atroviride and C. globosum strains. The metabolic state of the indoor fungal growth may influence emission of liquid soluble bioreactive metabolites into the indoor air.

9.
Indoor Air ; 30(6): 1109-1129, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32657456

RESUMO

The aim of this review was to investigate human exposure to relevant indoor air contaminants, predictors affecting the levels, and the means to reduce the harmful exposure in indoor sports facilities. Our study revealed that the contaminants of primary concern are the following: particulate matter in indoor climbing, golf, and horse riding facilities; carbon dioxide and particulate matter in fitness centers, gymnasiums, and sports halls; Staphylococci on gymnasium surfaces; nitrogen dioxide and carbon monoxide in ice hockey arenas; carbon monoxide, nitrogen oxide(s), and particulate matter in motor sports arenas; and disinfection by-products in indoor chlorinated swimming pools. Means to reduce human exposure to indoor contaminants include the following: adequate mechanical ventilation with filters, suitable cleaning practices, a limited number of occupants in fitness centers and gymnasiums, the use of electric resurfacers instead of the engine powered resurfacers in ice hockey arenas, carefully regulated chlorine and temperature levels in indoor swimming pools, properly ventilated pools, and good personal hygiene. Because of the large number of susceptible people in these facilities, as well as all active people having an increased respiratory rate and airflow velocity, strict air quality requirements in indoor sports facilities should be maintained.


Assuntos
Poluição do Ar em Ambientes Fechados/estatística & dados numéricos , Exposição Ambiental/estatística & dados numéricos , Esportes , Humanos , Material Particulado
10.
Toxins (Basel) ; 12(7)2020 07 08.
Artigo em Inglês | MEDLINE | ID: mdl-32650391

RESUMO

The diversity of Chaetomium-like isolates in buildings in Finland is poorly documented. This paper describes a set of methods for rapid diversity tracking of 42 indoor Chaetomium-like isolates. These isolates were categorized based on their fluorescence emission, ascomatal hair morphology, responses in three bioassays and resistance/sensitivity to the wetting agent Genapol X-080. Thirty-nine toxigenic isolates were identified [Ch. globosum (n = 35), Ch. cochliodes (n = 2) and Ch. rectangulare (n = 2)]. These isolates were identified down to the species level by tef1α gene sequencing. The major toxic substances in the ethanol extracts of the Ch. globosum and Ch. cochliodes strains were chaetoglobosin, chaetoviridin A and C, chaetomugilin D and chaetomin, identified based on HPLC-UV and mass spectrometry data (MS and MS/MS). Ethanol extracts from pure Ch. globosum cultures exhibited a toxicological profile in the boar sperm motility inhibition assay (BSMI), sperm membrane integrity damage assay (SMID) and inhibition of cell proliferation (ICP) assay, similar to that exhibited by pure chaetoglobosin A. Overall, differences in fluorescence, morphology, toxicity profile, mycotoxin production and sensitivity to chemicals were consistent with those in tef1α sequencing results for species identification. The results indicate the presence of Ch. cochliodes and Ch. rectangulare in Finnish buildings, representing a new finding.


Assuntos
Microbiologia do Ar , Chaetomium/metabolismo , Poeira , Micotoxinas/análise , Animais , Linhagem Celular Tumoral , Proliferação de Células/efeitos dos fármacos , Chaetomium/genética , Finlândia , Masculino , Mitocôndrias/efeitos dos fármacos , Mitocôndrias/metabolismo , Micotoxinas/genética , Micotoxinas/toxicidade , Motilidade dos Espermatozoides/efeitos dos fármacos , Espermatozoides/efeitos dos fármacos , Espermatozoides/patologia , Sus scrofa
11.
Environ Int ; 141: 105781, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32417615

RESUMO

Reported indoor air quality (IAQ) complaints are common even in relatively new or renovated school buildings in Finland. However, detecting the causes for complaints with commonly used indoor air measurements is difficult. This study presents data on perceived and measured IAQ in six comprehensive school buildings in Finland. The aim of this study was to discover the possible differences of perceived and measured IAQ between schools with reported IAQ complaints and schools without reported IAQ complaints. The initial categorisation of schools with ('problematic schools') and without ('comparison schools') complaints was ensured via a validated indoor climate survey and a recently developed online questionnaire, which were completed by 186 teachers and 1268 students from the six schools. IAQ measurements of physical parameters, gaseous pollutants, particulate matter and bioaerosols were conducted in four problematic school buildings (26 classrooms) and two comparison school buildings (12 classrooms). Using air sampling as well as exhaust air filters and classroom settled dust to detect the presence of elevated concentrations of airborne cultivable microbes and pathogenic, toxigenic and mycoparasitic Trichoderma strains were the most indicative methods in distinguishing problematic schools from comparison schools. Other IAQ-related measurements did not detect clear differences between problematic and comparison schools, as the concentration levels were very low. The results indicate that the complaints reported by occupants could have been related to excess moisture or mould problems that had not been found or repaired. Ventilation pressure condition investigations and simultaneous exhaust and supply air filter dust culture should be addressed precisely in future studies.


Assuntos
Poluição do Ar em Ambientes Fechados , Finlândia , Humanos , Material Particulado/análise , Instituições Acadêmicas , Ventilação
12.
Toxins (Basel) ; 11(12)2019 11 21.
Artigo em Inglês | MEDLINE | ID: mdl-31766362

RESUMO

The occurrence and toxin production of the opportunistic pathogen Aspergillus calidoustus in Finnish buildings is not well documented in the literature. We tracked and identified four A. calidoustus colonies cultivated from indoor settled dusts and revealed the biological activities of crude biomass extracts. The toxic substances were identified as 6-epi-ophiobolin K, ophiobolin K, and ophiobolin G by high-performance liquid chromatography-mass spectrometry (HPLC-MS) based on chromatographic and mass spectrometry data (MS and MS/MS) on the crude extract of A. calidoustus strain MH34. A total of 29 fungal colonies collected from settled dust in an office room reported for indoor-air-related illnesses were screened for toxins that inhibited boar sperm motility in the BSMI (boar sperm motility inhibiting) assay and cell proliferation in the ICP (inhibition of cell proliferation) assays with PK-15 cells. Out of the 27 colonies tested as toxic, 12 colonies exhibiting conidiophores representative of the genera Chaetomium, Penicillium, and Paecilomyces were excluded from the study, while 13 colonies exhibited Aspergillus-like conidiophores. Biomass suspensions of these colonies were divided into two categories: Category 1 colonies (n = 4), toxic in the BSMI assay and the ICP assays, emitted blue fluorescence and grew at 37 °C; Category 2 colonies (n = 9), only toxic in the ICP assay, emitted orange fluorescence and exhibited limited or no growth at 37 °C. Colonies in Category 1 were pure-cultured, and the strains were named as MH4, MH21, MH34, MH36. Strain MH34 was identified as A. calidoustus by the internal transcribed spacer (ITS) sequences. Ethanol-soluble dry substances extracted from the biomass of the pure cultures exhibited a toxicological profile in the BSMI assay, SMID (sperm membrane integrity damage) assay, and ICP assay similar to that exhibited by pure ophiobolin A. Overall, the viable conidia of A. calidoustus in indoor settled dusts deserve attention when potentially hazardous mold species are monitored.


Assuntos
Aspergillus/metabolismo , Fungos/química , Micotoxinas/farmacologia , Sesterterpenos/farmacologia , Animais , Aspergillus/química , Bioensaio , Biomassa , Cromatografia Líquida de Alta Pressão , Poeira/análise , Finlândia , Masculino , Espectrometria de Massas , Micotoxinas/isolamento & purificação , Sesterterpenos/isolamento & purificação , Motilidade dos Espermatozoides/efeitos dos fármacos , Espermatozoides/efeitos dos fármacos , Suínos , Espectrometria de Massas em Tandem
13.
Front Microbiol ; 10: 1434, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31293557

RESUMO

This study examined the structural diversity and bioactivity of peptaibol compounds produced by species from the phylogenetically separated Longibrachiatum Clade of the filamentous fungal genus Trichoderma, which contains several biotechnologically, agriculturally and clinically important species. HPLC-ESI-MS investigations of crude extracts from 17 species of the Longibrachiatum Clade (T. aethiopicum, T. andinense, T. capillare, T. citrinoviride, T. effusum, T. flagellatum, T. ghanense, T. konilangbra, T. longibrachiatum, T. novae-zelandiae, T. pinnatum, T. parareesei, T. pseudokoningii, T. reesei, T. saturnisporum, T. sinensis, and T. orientale) revealed several new and recurrent 20-residue peptaibols related to trichobrachins, paracelsins, suzukacillins, saturnisporins, trichoaureocins, trichocellins, longibrachins, hyporientalins, trichokonins, trilongins, metanicins, trichosporins, gliodeliquescins, alamethicins and hypophellins, as well as eight 19-residue sequences from a new subfamily of peptaibols named brevicelsins. Non-ribosomal peptide synthetase genes were mined from the available genome sequences of the Longibrachiatum Clade. Their annotation and product prediction were performed in silico and revealed full agreement in 11 out of 20 positions regarding the amino acids predicted based on the signature sequences and the detected amino acids incorporated. Molecular dynamics simulations were performed for structural characterization of four selected peptaibol sequences: paracelsins B, H and their 19-residue counterparts brevicelsins I and IV. Loss of position R6 in brevicelsins resulted in smaller helical structures with higher atomic fluctuation for every residue than the structures formed by paracelsins. We observed the formation of highly bent, almost hairpin-like, helical structures throughout the trajectory, along with linear conformation. Bioactivity tests were performed on the purified peptaibol extract of T. reesei on clinically and phytopathologically important filamentous fungi, mammalian cells, and Arabidopsis thaliana seedlings. Porcine kidney cells and boar spermatozoa proved to be sensitive to the purified peptaibol extract. Peptaibol concentrations ≥0.3 mg ml-1 deterred the growth of A. thaliana. However, negative effects to plants were not detected at concentrations below 0.1 mg ml-1, which could still inhibit plant pathogenic filamentous fungi, suggesting that those peptaibols reported here may have applications for plant protection.

14.
Indoor Air ; 29(6): 903-912, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31348556

RESUMO

Degrading 2-ethylhexyl-containing PVC floorings (eg DEHP-PVC floorings) and adhesives emit 2-ethylhexanol (2-EH) in the indoor air. The danger of flooring degradation comes from exposing occupants to harmful phthalates plasticisers (eg DEHP), but not from 2-EH as such. Since the EU banned the use of phthalates in sensitive applications, the market is shifting to use DEHP-free and alternative types of plasticisers in PVC products. However, data on emissions from DEHP-free PVC floorings are scarce. This study aimed at assessing the surface and bulk emissions of two DEHP-free PVC floorings over three years. The floorings were glued on the screed layer of concrete casts at 75%, 85%, and 95% RH. The volatile organic compounds (VOCs) were actively sampled using FLEC (surface emissions) and micro-chamber/thermal extractor (µ-CTE, bulk emissions) onto Tenax TA adsorbents and analyzed with TD-GC-MS. 2-EH, C9-alcohols, and total volatile organic compound (TVOC) emissions are reported. Emissions at 75% and 85% RH were similar. As expected, the highest emissions occurred at 95% RH. 2-EH emissions originated from the adhesive. Because the two DEHP-free floorings tested emitted C9-alcohols at all tested RH, it makes the detection of flooring degradation harder, particularly if the adhesive used does not emit 2-EH.


Assuntos
Poluição do Ar em Ambientes Fechados/análise , Exposição Ambiental/análise , Pisos e Cobertura de Pisos , Adesivos/análise , Álcoois/análise , Monitoramento Ambiental , Hexanóis/análise , Humanos , Plastificantes/análise , Compostos Orgânicos Voláteis/análise
15.
Reprod Domest Anim ; 54(9): 1279-1283, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31348839

RESUMO

Bacillus anthracis infecting cattle is usually identified based on the typical symptom: sudden death. Bacillus anthracis causing atypical symptoms may remain undiagnosed and represent a potential occupational health hazard for, that is veterinarians and producers, butchers and tanners. In the year 2004, one case of sudden death in a dairy farm in southern Finland was diagnosed as bovine anthrax. Four years later 2008, an atypical case of anthrax was diagnosed in the same holding. The bull was taken to the Production Animal Hospital of the Faculty of Veterinary Medicine, University of Helsinki because of fever, loss of appetite and a symmetrically swollen scrotal sac. Penicillin treatment cured the fever but not the swollen scrotum. Before the intended therapeutic castration, a punctuate consisting of 10 ml fluid collected into a syringe from the scrotal sac was cultivated on blood agar at 37°C. After 24 hr, an almost pure culture of a completely non-hemolytic Bacillus cereus-like bacteria was obtained. The strain was identified as B. anthracis using Ba-specific primers by the Finnish Food Safety Authority (RUOKAVIRASTO). After the diagnosis, the bull was euthanized and destroyed, the personnel were treated with prophylactic antibiotics and the clinic was disinfected. In this particular case, treatment with water, Virkon S and lime seemed to be effective to eliminate endospores and vegetative cells since no relapses of anthrax have occurred in 10 years. This case is the last reported anthrax case in Finland.


Assuntos
Antraz/veterinária , Bacillus anthracis , Doenças dos Bovinos/microbiologia , Exposição Ocupacional/prevenção & controle , Animais , Antraz/diagnóstico , Antraz/tratamento farmacológico , Antibacterianos/uso terapêutico , Compostos de Cálcio/química , Bovinos , Desinfetantes , Finlândia , Hospitais Veterinários , Humanos , Masculino , Orquite/microbiologia , Orquite/veterinária , Óxidos/química , Penicilina G Procaína/uso terapêutico , Peróxidos , Ácidos Sulfúricos
16.
Environ Int ; 130: 104887, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31195224

RESUMO

BACKGROUND: Although nitrogen dioxide (NO2) is one of the most common air pollutants encountered indoors, and extensive literature has examined the link between NO2 exposure and duration causing adverse respiratory effects in susceptible populations, information about global and local exposure to NO2 in different indoor environments is limited. To synthesize the existing knowledge, this review analyzes the magnitude of and the trends in global and local exposure to NO2 in schools and offices, and the factors that control exposure. METHODS: For the literature review, Web of Science, SCOPUS, Google Scholar, and PubMed were searched using 42 search terms and their combinations to identify manuscripts, reports, and directives published between 1971 and 2019. The search was then extended to the reference lists of relevant articles. RESULTS: The calculated median, as well as the mean, concentration of NO2 in school (median 21.1 µg/m3; mean 29.4 µg/m3) and office settings (median 22.7 µg/m3; mean 25.1 µg/m3) was well below the World Health Organization (WHO) guideline of 40 µg/m3 for the annual mean NO2 concentration. However, a large range of average concentrations of NO2 were reported, from 6.00 to 68.5 µg/m3 and from 3.40 to 56.5 µg/m3 for school and office environments, respectively, indicating situations where the WHO guidelines are exceeded. Outdoor levels of NO2 are a reliable predictor of indoor NO2 levels across seasons, with mean and median Indoor/Outdoor (I/O) ratios of 0.9 and 0.7 in school and 0.9 and 0.8 in office environments, respectively. The absence of major indoor NO2 emission sources and NO2 sinks, including chemical reactions and deposition, are the reasons for lower indoor NO2 concentrations. During the winter, outdoor NO2 concentrations are generally higher than during the summer. In addition, various building and indoor environment characteristics, such as type of ventilation, air exchange rates, airtightness of the envelope, furnishing and surface characteristics of the building, location of the building (urban versus suburban and proximity to traffic routes), as well as occupants' behavior (such as opening windows), have been statistically significantly associated with indoor NO2 levels in school and office environments. CONCLUSIONS: Indoor exposure to NO2 from the infiltration of ambient air can be significant in urban areas, and in the case of high traffic volume. Although reducing transportation emissions is challenging, there are several easier means to reduce indoor NO2 concentrations, including a ventilation strategy with suitable filters; location planning of new schools, classrooms, and ventilating windows or intakes; traffic planning (location and density); and reducing the use of NO2-releasing indoor sources.


Assuntos
Poluentes Atmosféricos/análise , Poluição do Ar em Ambientes Fechados/análise , Exposição por Inalação/análise , Dióxido de Nitrogênio/análise , Humanos , Instituições Acadêmicas , Local de Trabalho
17.
Toxins (Basel) ; 10(11)2018 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-30413106

RESUMO

A novel, objective, and rapid computed motility inhibition (CMI) assay was developed to identify and assess sublethal injury in toxin-exposed boar spermatozoa and compared with a subjective visual motility inhibition (VMI) assay. The CMI values were calculated from digital micrographic videos using a custom MATLAB® script by contrasting the motility index values of each experiment with those of the background and control experiments. Following a comparison of the CMI and VMI assays results, it was determined that their agreement depended on the shape of the dose-response curve. Toxins that exhibited a steep slope were indicative of good agreement between the assays. Those depicted by a gentle decline in the slope of the dose-response curve, the CMI assay were shown to be two times more sensitive than the VMI assay. The CMI assay was highly sensitive to the inhibition of mitochondrial function and glucose transport activity by sublethal doses of toxins and to disruption of cellular cation homeostasis by carrier ionophoric toxins, when compared to the cytotoxicity and lethal toxicity assays (i.e., that evaluated the inhibition of cell proliferation in somatic cell lines (FL, PK-15, and MNA cells)) and disruption to spermatozoa membrane integrity. The CMI assay recognized subtle sublethal toxicity changes in metabolism, manifested as a decrease in boar spermatozoa motility. Thus, it was feasible to effectively compare the objectively-measured numerical values for motility inhibition using the CMI assay against those reflecting lethal damage in the spermatozoa cells and somatic cell lines using a cytotoxicity assay.


Assuntos
Motilidade dos Espermatozoides/efeitos dos fármacos , Espermatozoides/efeitos dos fármacos , Testes de Toxicidade/métodos , Poluição do Ar em Ambientes Fechados/efeitos adversos , Animais , Bactérias , Técnicas Biossensoriais , Carbonil Cianeto p-Trifluormetoxifenil Hidrazona/toxicidade , Gatos , Linhagem Celular , Fungos , Masculino , Camundongos , Dicromato de Potássio/toxicidade , Espermatozoides/fisiologia , Suínos , Toxinas Biológicas/toxicidade , Triclosan/toxicidade
18.
Environ Int ; 119: 503-514, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30053738

RESUMO

BACKGROUND: Although it is recognized that ozone causes acute and chronic health effects and that even trace amounts of ozone are potentially deleterious to human health, information about global and local exposures to ozone in different indoor environments is limited. To synthesize the existing knowledge, this review analyzes the magnitude of and the trends in global and local exposure to ozone in schools and offices and the factors controlling the exposures. METHODS: In conducting the literature review, Web of Science, SCOPUS, Google Scholar, and PubMed were searched using 38 search terms and their combinations to identify manuscripts, reports, and directives published between 1973 and 2018. The search was then extended to the reference lists of relevant articles. RESULTS: The calculated median concentration of ozone both in school (8.50 µg/m3) and office (9.04 µg/m3) settings was well below the WHO guideline value of 100 µg/m3 as a maximum 8 h mean concentration. However, a large range of average concentrations of ozone was reported, from 0.8-114 µg/m3 and from 0 to 96.8 µg/m3 for school and office environments, respectively, indicating situations where the WHO values are exceeded. Outdoor ozone penetrating into the indoor environment is the main source of indoor ozone, with median I/O ratios of 0.21 and 0.29 in school and office environments, respectively. The absence of major indoor ozone sources and ozone sinks, including gas-phase reactions and deposition, are the reasons for lower indoor than outdoor ozone concentrations. However, there are indoor sources of ozone that are of significance in certain indoor environments, including printers, photocopiers, and many other devices and appliances designed for indoor use (e.g., air cleaners), that release ozone either intentionally or unintentionally. Due to significantly elevated outdoor ozone concentrations during summer, summer indoor concentrations are typically elevated. In addition, the age of a building and various housing aspects (carpeting, air conditioning, window fans, and window openings) have been significantly associated with indoor ozone levels. CONCLUSIONS: The existing means for reducing ozone and ozone reaction products in school and office settings are as follows: 1) reduce penetration of outdoor ozone indoors by filtering ozone from the supply air; 2) limit the use of printers, photocopiers, and other devices and appliances that emit ozone indoors; 3) limit gas-phase reactions by limiting the use of materials and products (e.g. cleaning chemicals) the emissions of which react with ozone.


Assuntos
Poluentes Atmosféricos/análise , Poluição do Ar em Ambientes Fechados/análise , Ozônio/análise , Instituições Acadêmicas , Local de Trabalho , Monitoramento Ambiental , Humanos
19.
Artigo em Inglês | MEDLINE | ID: mdl-29976864

RESUMO

Ventilation system design and operation may significantly affect indoor air quality (IAQ). The aims of this case study were to investigate the functionality of a supply air fan-assisted hybrid ventilation system in a newly built school building with reported IAQ problems and to determine the effects of ventilation improvement on measured and perceived IAQ. The ventilation system function was researched simultaneously with IAQ measurements, with an analysis of total volatile organic compounds (TVOC), single volatile organic compounds (VOCs), and indoor mycobiota, and with questionnaires about perceived IAQ. At the baseline, an operational error of the ventilation system was found, which prevented the air from coming into the classrooms, except for short periods of high carbon dioxide (CO2) concentrations. After the ventilation operation was improved, a significant change in indoor mycobiota was found; the dominant, opportunistic human pathogenic species Trichoderma citrinoviride found in settled dust in the classroom before the improvement was no longer detected. In addition, the concentrations of CO2, TVOC, and some single VOCs, especially toluene and decamethylcyclopentasiloxane, decreased. The analysis of the questionnaire results indicated that the perceptions of unpleasant odors and stuffy air decreased, although a statistically significant improvement in perceived IAQ was not observed. The results provided evidence that the properly controlled hybrid ventilation system operating in mechanical supply mode provided adequate ventilation and was effective in decreasing the concentrations of some indoor-generated pollutants. With simple ventilation adjustments, microbiological exposure from building structures might be prevented.


Assuntos
Poluentes Atmosféricos/análise , Poluição do Ar em Ambientes Fechados/análise , Exposição Ambiental/análise , Instituições Acadêmicas , Ventilação/normas , Microbiologia do Ar/normas , Criança , Monitoramento Ambiental , Humanos , Trichoderma/isolamento & purificação , Ventilação/instrumentação
20.
Artigo em Inglês | MEDLINE | ID: mdl-29617335

RESUMO

The aim of this study was to develop and test a tool for assessing urgency of indoor air quality (IAQ) measures. The condition of the 27 buildings were investigated and results were categorized. Statistical test studied the differences between the categories and the employees’ complaints about their work environment. To study the employees’ experiences of the work premises, a validated indoor air (IA) questionnaire was used. This study reveals a multifaceted problem: many factors affecting IAQ may also affect perceived IAQ, making it difficult to separate the impurity sources and ventilation system deficiencies affecting to employee experiences. An examination of the relationship between the categories and perceived IAQ revealed an association between the mould odour perceived by employees and mould detected by the researcher. A weak link was also found between the assessed categories and environmental complaints. However, we cannot make far-reaching conclusions regarding the assessed probability of abnormal IA exposure in the building on the basis of employee experiences. According to the results, categorising tool can partly support the assessment of the urgency for repairs when several factors that affect IAQ are taken into account.


Assuntos
Ar Condicionado/normas , Poluição do Ar em Ambientes Fechados/estatística & dados numéricos , Exposição Ambiental/normas , Monitoramento Ambiental/métodos , Hospitais/normas , Medição de Risco/métodos , Local de Trabalho/normas , Adulto , Feminino , Finlândia , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA