Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 19(9)2019 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-31064098

RESUMO

The automatic traffic sign detection and recognition (TSDR) system is very important research in the development of advanced driver assistance systems (ADAS). Investigations on vision-based TSDR have received substantial interest in the research community, which is mainly motivated by three factors, which are detection, tracking and classification. During the last decade, a substantial number of techniques have been reported for TSDR. This paper provides a comprehensive survey on traffic sign detection, tracking and classification. The details of algorithms, methods and their specifications on detection, tracking and classification are investigated and summarized in the tables along with the corresponding key references. A comparative study on each section has been provided to evaluate the TSDR data, performance metrics and their availability. Current issues and challenges of the existing technologies are illustrated with brief suggestions and a discussion on the progress of driver assistance system research in the future. This review will hopefully lead to increasing efforts towards the development of future vision-based TSDR system.

2.
Sensors (Basel) ; 14(7): 11522-41, 2014 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-24984057

RESUMO

The use of wireless communication using inductive links to transfer data and power to implantable microsystems to stimulate and monitor nerves and muscles is increasing. This paper deals with the development of the theoretical analysis and optimization of an inductive link based on coupling and on spiral circular coil geometry. The coil dimensions offer 22 mm of mutual distance in air. However, at 6 mm of distance, the coils offer a power transmission efficiency of 80% in the optimum case and 73% in the worst case via low input impedance, whereas, transmission efficiency is 45% and 32%, respectively, via high input impedance. The simulations were performed in air and with two types of simulated human biological tissues such as dry and wet-skin using a depth of 6 mm. The performance results expound that the combined magnitude of the electric field components surrounding the external coil is approximately 98% of that in air, and for an internal coil, it is approximately 50%, respectively. It can be seen that the gain surrounding coils is almost constant and confirms the omnidirectional pattern associated with such loop antennas which reduces the effect of non-alignment between the two coils. The results also show that the specific absorption rate (SAR) and power loss within the tissue are lower than that of the standard level. Thus, the tissue will not be damaged anymore.


Assuntos
Desenho Assistido por Computador , Transferência de Energia , Modelos Biológicos , Próteses e Implantes , Fenômenos Fisiológicos da Pele , Telemetria/instrumentação , Tecnologia sem Fio/instrumentação , Ar , Desenho de Equipamento , Análise de Falha de Equipamento , Telemetria/métodos
3.
Biomed Eng Online ; 13: 79, 2014 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-24950601

RESUMO

The development of implanted devices is essential because of their direct effect on the lives and safety of humanity. This paper presents the current issues and challenges related to all methods used to harvest energy for implantable biomedical devices. The advantages, disadvantages, and future trends of each method are discussed. The concept of harvesting energy from environmental sources and human body motion for implantable devices has gained a new relevance. In this review, the harvesting kinetic, electromagnetic, thermal and infrared radiant energies are discussed. Current issues and challenges related to the typical applications of these methods for energy harvesting are illustrated. Suggestions and discussion of the progress of research on implantable devices are also provided. This review is expected to increase research efforts to develop the battery-less implantable devices with reduced over hole size, low power, high efficiency, high data rate, and improved reliability and feasibility. Based on current literature, we believe that the inductive coupling link is the suitable method to be used to power the battery-less devices. Therefore, in this study, the power efficiency of the inductive coupling method is validated by MATLAB based on suggested values. By further researching and improvements, in the future the implantable and portable medical devices are expected to be free of batteries.


Assuntos
Fontes de Energia Elétrica , Equipamentos e Provisões , Próteses e Implantes , Humanos
4.
Biomed Tech (Berl) ; 59(3): 257-68, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24445231

RESUMO

Use of transcutaneous inductive links is a widely known method for the wireless powering of bio-implanted devices such as implanted microsystems. The design of the coil for inductive links is generally not optimal. In this study, inductive links were used on the basis of the small loop antenna theory to reduce the effects of lateral coil misalignments on the biological human tissue model at 13.56 MHz. The tissue, which measures 60 mm×70 mm×5 mm, separates the reader and the implanted coils. The aligned coils and the lateral misalignment coils were investigated in different parametric x-distance misalignments. The optimal coil layout was developed on the basis of the layout rules presented in previous studies. Results show that the gain around the coils, which were separated by wet and dry skin, was constant and confirmed the omnidirectional radiation pattern even though the lateral misalignment between coils was smaller or greater than the implanted coil radius. This misalignment can be <4 mm or >6 mm up to 8 mm. Moreover, coil misalignments and skin condition do not affect the efficient performance of the coil.


Assuntos
Fontes de Energia Elétrica , Transferência de Energia , Magnetismo/instrumentação , Modelos Biológicos , Próteses e Implantes , Implantação de Prótese/métodos , Tecnologia sem Fio/instrumentação , Simulação por Computador , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos
5.
Sensors (Basel) ; 14(12): 23843-70, 2014 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-25615728

RESUMO

With the development of communication technologies, the use of wireless systems in biomedical implanted devices has become very useful. Bio-implantable devices are electronic devices which are used for treatment and monitoring brain implants, pacemakers, cochlear implants, retinal implants and so on. The inductive coupling link is used to transmit power and data between the primary and secondary sides of the biomedical implanted system, in which efficient power amplifier is very much needed to ensure the best data transmission rates and low power losses. However, the efficiency of the implanted devices depends on the circuit design, controller, load variation, changes of radio frequency coil's mutual displacement and coupling coefficients. This paper provides a comprehensive survey on various power amplifier classes and their characteristics, efficiency and controller techniques that have been used in bio-implants. The automatic frequency controller used in biomedical implants such as gate drive switching control, closed loop power control, voltage controlled oscillator, capacitor control and microcontroller frequency control have been explained. Most of these techniques keep the resonance frequency stable in transcutaneous power transfer between the external coil and the coil implanted inside the body. Detailed information including carrier frequency, power efficiency, coils displacement, power consumption, supplied voltage and CMOS chip for the controllers techniques are investigated and summarized in the provided tables. From the rigorous review, it is observed that the existing automatic frequency controller technologies are more or less can capable of performing well in the implant devices; however, the systems are still not up to the mark. Accordingly, current challenges and problems of the typical automatic frequency controller techniques for power amplifiers are illustrated, with a brief suggestions and discussion section concerning the progress of implanted device research in the future. This review will hopefully lead to increasing efforts towards the development of low powered, highly efficient, high data rate and reliable automatic frequency controllers for implanted devices.


Assuntos
Fontes de Energia Elétrica , Eletrônica Médica/métodos , Próteses e Implantes , Processamento de Sinais Assistido por Computador , Amplificadores Eletrônicos , Humanos , Ondas de Rádio , Software , Telemetria/métodos
6.
Sensors (Basel) ; 12(1): 297-319, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22368470

RESUMO

Implanted medical devices are very important electronic devices because of their usefulness in monitoring and diagnosis, safety and comfort for patients. Since 1950s, remarkable efforts have been undertaken for the development of bio-medical implanted and wireless telemetry bio-devices. Issues such as design of suitable modulation methods, use of power and monitoring devices, transfer energy from external to internal parts with high efficiency and high data rates and low power consumption all play an important role in the development of implantable devices. This paper provides a comprehensive survey on various modulation and demodulation techniques such as amplitude shift keying (ASK), frequency shift keying (FSK) and phase shift keying (PSK) of the existing wireless implanted devices. The details of specifications, including carrier frequency, CMOS size, data rate, power consumption and supply, chip area and application of the various modulation schemes of the implanted devices are investigated and summarized in the tables along with the corresponding key references. Current challenges and problems of the typical modulation applications of these technologies are illustrated with a brief suggestions and discussion for the progress of implanted device research in the future. It is observed that the prime requisites for the good quality of the implanted devices and their reliability are the energy transformation, data rate, CMOS size, power consumption and operation frequency. This review will hopefully lead to increasing efforts towards the development of low powered, high efficient, high data rate and reliable implanted devices.


Assuntos
Eletrônica Médica/instrumentação , Próteses e Implantes , Processamento de Sinais Assistido por Computador , Telemetria/métodos
7.
Sensors (Basel) ; 10(2): 1141-53, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-22205861

RESUMO

This paper deals with the interface-relevant activity of a vehicle integrated intelligent safety system (ISS) that includes an airbag deployment decision system (ADDS) and a tire pressure monitoring system (TPMS). A program is developed in LabWindows/CVI, using C for prototype implementation. The prototype is primarily concerned with the interconnection between hardware objects such as a load cell, web camera, accelerometer, TPM tire module and receiver module, DAQ card, CPU card and a touch screen. Several safety subsystems, including image processing, weight sensing and crash detection systems, are integrated, and their outputs are combined to yield intelligent decisions regarding airbag deployment. The integrated safety system also monitors tire pressure and temperature. Testing and experimentation with this ISS suggests that the system is unique, robust, intelligent, and appropriate for in-vehicle applications.


Assuntos
Automóveis , Segurança , Software , Algoritmos , Automóveis/normas , Sistemas Computacionais , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA