Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Assunto principal
Intervalo de ano de publicação
1.
Int J Nephrol Renovasc Dis ; 16: 197-206, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37720492

RESUMO

Purpose: The study aimed to create a machine learning model (MLM) to predict the stone-free status (SFS) of patients undergoing percutaneous nephrolithotomy (PCNL) and compare its performance to the S.T.O.N.E. and Guy's stone scores. Patients and Methods: This is a retrospective study that included 320 PCNL patients. Pre-operative and post-operative variables were extracted and entered into three MLMs: RFC, SVM, and XGBoost. The methods used to assess the performance of each were mean bootstrap estimate, 10-fold cross-validation, classification report, and AUC. Each model was externally validated and evaluated by mean bootstrap estimate with CI, classification report, and AUC. Results: Out of the 320 patients who underwent PCNL, the SFS was found to be 69.4%. The RFC mean bootstrap estimate was 0.75 and 95% CI: [0.65-0.85], 10-fold cross-validation of 0.744, an accuracy of 0.74, and AUC of 0.761. The XGBoost results were 0.74 [0.63-0.85], 0.759, 0.72, and 0.769, respectively. The SVM results were 0.70 [0.60-0.79], 0.725, 0.74, and 0.751, respectively. The AUC of Guy's stone score and the S.T.O.N.E. score were 0.666 and 0.71, respectively. The RFC external validation set had a mean bootstrap estimate of 0.87 and 95% CI: [0.81-0.92], an accuracy of 0.70, and an AUC of 0.795, While the XGBoost results were 0.84 [0.78-0.91], 0.74, and 0.84, respectively. The SVM results were 0.86 [0.80-0.91], 0.79, and 0.858, respectively. Conclusion: MLMs can be used with high accuracy in predicting SFS for patients undergoing PCNL. MLMs we utilized predicted the SFS with AUCs superior to those of GSS and S.T.O.N.E scores.

2.
Acta Neurochir (Wien) ; 165(6): 1523-1531, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37071182

RESUMO

BACKGROUND: The M.scio telesensor (Aesculap-Miethke, Germany) is a device integrated within a ventriculoperitoneal (VP) shunt for non-invasive measurement of the intracranial pressure (ICP). The purpose of this study was to analyze the telemetric recordings with the M.scio system in shunted patients with idiopathic intracranial hypertension (IIH), in order to determine reference values and assist the interpretation of telemetric data. METHODS: This was a cohort study of consecutive patients with fulminant IIH who underwent primary VP shunt insertion between July 2019 and June 2022. The first telemetric measurements after surgery in the sitting and supine positions were analyzed. Telemetric ICP values, wave morphology, and pulse amplitude were determined for functioning and malfunctioning shunts. RESULTS: Fifty-seven out of 64 patients had available telemetric recordings. The mean ICP was - 3.8 mmHg (standard deviation (SD) = 5.9) in the sitting and 16.4 mmHg (SD = 6.3) in the supine position. The ICP curve demonstrated pulsatility in 49 (86%) patients. A pulsatile curve with mean ICP in the above ranges indicated a functioning shunt, whereas the lack of pulsatility was challenging to interpret. There was a significant positive correlation between ICP versus amplitude, ICP versus body mass index (BMI), and amplitude versus BMI. CONCLUSIONS: This clinical study defined ICP values and curves in IIH patients with a shunt. The results will assist the interpretation of telemetric ICP recordings in clinical decision making. More research is required to model longitudinal recordings and explore the link between telemetric measurements with clinical outcomes.


Assuntos
Pseudotumor Cerebral , Humanos , Pseudotumor Cerebral/diagnóstico , Pseudotumor Cerebral/cirurgia , Pressão Intracraniana , Estudos de Coortes , Derivação Ventriculoperitoneal/métodos , Telemetria/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA