Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Heart ; 109(20): 1558-1563, 2023 09 28.
Artigo em Inglês | MEDLINE | ID: mdl-37230740

RESUMO

OBJECTIVE: To identify differences in left ventricular (LV) remodelling between patients with bicuspid aortic valve (BAV) and trileaflet aortic valve (TAV) with chronic aortic regurgitation (AR). METHODS: Retrospective cohort study of 210 consecutive patients undergoing cardiac magnetic resonance for AR evaluation. We divided the study population according to valvular morphology. Independent predictors of LV enlargement AR were evaluated. RESULTS: There were 110 patients with BAV and 100 patients with TAV. Patients with BAV were younger (mean age BAV vs TAV: 41±16 years vs 67±11 years; p<0.01), mostly male (% male BAV vs TAV: 84.5% vs 65%, p=0.01) and presented milder degrees of AR (median regurgitant fraction BAV vs TAV: 14 (6-28)% vs 22 (12-35)%, p=0.002). Both groups presented similar indexed LV volumes and ejection fraction. According to the degree of AR, at mild AR, patients with BAV presented larger LV volumes (BAV vs TAV: indexed end diastolic left ventricular volumes (iEDV): 96.5±19.7 vs 82.1±19.3 mL, p<0.01; indexed end systolic left ventricular volumes (iESV): 39.4±10.3 mL vs 33.2±10.5 mL, p=0.01). These differences disappeared at higher degrees of AR. Independent predictors of LV enlargement were regurgitant fraction (EDV: OR 1.118 (1.081-1.156), p<0.001; ESV: OR 1.067 (1.042-1.092), p<0.001), age (EDV: OR 0.940 (0.917-0.964), p<0.001, ESV: OR 0.962 (0.945-0.979), p<0.001) and weight (EDV: OR 1.054 (1.025-1.083), p<0.001). CONCLUSIONS: In chronic AR, LV enlargement is an early finding. LV volumes display a direct correlation with regurgitant fraction and an inverse association with age. Patients with BAV present larger ventricular volumes, especially at mild AR. However, these differences are attributable to demographic disparities; valve type is not independently associated with LV size.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Doenças das Valvas Cardíacas , Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Feminino , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/complicações , Estudos Retrospectivos , Valva Aórtica/diagnóstico por imagem , Espectroscopia de Ressonância Magnética
2.
Perfusion ; 38(4): 868-871, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-35225086

RESUMO

INTRODUCTION: Propofol infusion syndrome (PRIS) is a rare entity that could lead to profound cardiogenic shock (CS). Mitochondrial toxicity and sympathetic blockade are the mechanisms leading to CS in PRIS. CASE REPORT: We present a 22-year-old woman who developed refractory CS due to PRIS after aortic valve replacement surgery secondary to Coxiella infective endocarditis. She was rescued with VA-ECMO (veno-arterial extracorporeal membrane oxygenation) and was discharged 2 months later with no cardiac dysfunction. DISCUSSION: PRIS diagnosis is difficult even though propofol is frequently used in critical care units. Abrupt refractory CS in patients with recent use of high doses of propofol (> 4 mg/Kg/h) together with rhabdomyolysis should raise the suspicion. Diagnostic confirmation is based on muscle biopsy and fat enzyme analysis. CONCLUSION: Propofol withdrawal and support therapies-including VA-ECMO-are the treatment of choice in severe PRIS. VA-ECMO could increase survival as a bridge to recovery due to reversibility of PRIS.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Oxigenação por Membrana Extracorpórea , Síndrome da Infusão de Propofol , Propofol , Feminino , Humanos , Adulto Jovem , Adulto , Propofol/efeitos adversos , Choque Cardiogênico/terapia
3.
Heart ; 108(9): 725-732, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34285104

RESUMO

OBJECTIVES: The balloon-expandable Sapien-3 valve demonstrated superior results in terms of residual aortic regurgitation when compared with self-expandable devices. We aimed to compare for the first-time early outcomes of Sapien-3 transcatheter heart valve (THV) with the balloon-expandable Myval device. METHODS: Consecutive real-world patients from nine European institutions with symptomatic severe aortic stenosis treated either with Sapien-3 or Myval THV devices after June 2018 were compared. Early clinical outcomes were prospectively gathered and blinded analysis of 30-day echocardiography was conducted. Matching for the following variables was performed: age, body surface area, Society of Thoracic Surgeons risk score, left ventricular function, mean gradient, transfemoral approach, aortic valvular calcium, aortic annulus mean diameter, area and eccentricity index. RESULTS: A total of 416 patients treated either with the Sapien-3 (n=286, 68.7%) or with Myval THV (n=130, 31.3%) were included and 103 pairs compared after matching. Baseline characteristics were similar. Procedural success rate (Sapien-3: 94.2%; Myval: 93.2%, p=0.219), 30-day mortality (Sapien-3: 2.9%; Myval: 0.97%, p=0.625), clinical efficacy (12.6 vs 4.9%, p=0.057) and early safety (12.6 vs 4.9%, p=0.096) were comparable. There was a lower need for new permanent pacemaker (15.5 vs 5.8% p=0.020) with Myval. No significant differences were found in terms of ≥moderate aortic regurgitation (1% for Sapien-3, 0% for Myval, p=0.314), but mean gradients were higher following Sapien-3 than after Myval (p<0.001). CONCLUSIONS: The new Myval balloon-expandable THV was favourable in terms of safety, with low rate of permanent pacemaker and with favourable residual gradients and paravalvular leak rate according to blinded echocardiographic analysis.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Hemodinâmica , Humanos , Desenho de Prótese , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
4.
Eur Heart J Case Rep ; 5(8): ytab269, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34409247

RESUMO

BACKGROUND: Due to improvement in the management of patients with congenital heart disease (CHD), the likelihood of their survival to adulthood is increasing. A relevant population suffers end-stage right ventricular failure (RVF) in their 3rd-4th decade of life. Hence, heart transplantation is still gold standard of treatment of end-stage heart failure, mechanical circulatory assistance has become a valuable tool in the bridging to heart transplant or definitive therapy. Use of implantable short-term or long-term devices is reported by others. However, within this clinical context, presence of significant tricuspid regurgitation (TR) or CHD is used as exclusion criteria for insertion of a percutaneous right ventricular circulatory support. CASE SUMMARY: We described a 36-year-old patient diagnosed with Ebstein's anomaly and severe TR who is admitted to hospital due to RVF refractory to standard medical treatment. After case presentation to the heart team, an Impella RP device insertion was scheduled, in spite of the presence of TR or CHD after evaluation of pulmonary valve competency and 3D reconstruction with virtual device implantation. During support, the patient improved clinically and haemodynamically. Due to device displacement to the right ventricle, it was bedside explanted after 30 days of support. After mechanical unloading during 30 days patients' right ventricle recovered partially, permitting patient to improve his functional class. DISCUSSION: Although TR and CHD are exclusion criteria for the implantation of the Impella RP device, we report clinical experience in patient with Ebstein's anomaly and severe TR supported with percutaneous device as bridge to heart transplantation during 30 days.

5.
Radiologia ; 59(4): 321-328, 2017.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-28457532

RESUMO

OBJECTIVE: To analyze the usefulness of multidetector computed tomography (MDCT) in the preprocedural evaluation and follow-up of patients undergoing radiofrequency ablation of pulmonary veins and the impact of the MDCT findings on the approach to treatment. METHOD: We retrospectively analyzed 92 consecutive MDCT studies done in 80 patients between January 2011 and June 2013; 70 (76%) studies were done before a first ablation procedure and 22 (24%) were done in patients who had undergone an ablation procedure. RESULTS: Findings were useful in 34% of the patients who underwent MDCT before the first ablation procedure and in 68% of the studies done after a procedure. The incidence of stroke associated with the ablation procedure was 3%, similar to the incidence recorded in our center before we started to use MDCT to evaluate the anatomy of the left atrium. All symptomatic patients had some pulmonary vein stenosis, and 80% had significant stenosis. Furthermore, the stenoses progressed very rapidly; treatment with balloon angioplasty was associated with early restenosis. Stenting was an alternative in cases of failed angioplasty. CONCLUSION: In the preprocedural evaluation and postprocedural follow-up of patients undergoing pulmonary vein isolation, MDCT is useful for guiding treatment and detecting complications.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Tomografia Computadorizada Multidetectores , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Cuidados Pós-Operatórios , Cuidados Pré-Operatórios , Estudos Retrospectivos , Procedimentos Cirúrgicos Vasculares/métodos
6.
Rev Esp Cardiol (Engl Ed) ; 69(12): 1119-1125, 2016 Dec.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-27894486
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA