Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Rev Esp Cardiol (Engl Ed) ; 74(7): 602-607, 2021 Jul.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-32792313

RESUMO

INTRODUCTION AND OBJECTIVES: Early detection of atrial fibrillation (AF) is a priority to reduce embolic events by initiating oral anticoagulation therapy. The aim of this study was to evaluate the diagnostic ability of a wrist device designed for automatic AF detection. METHODS: RITHMI is a prospective, comparative, observational study that included 167 patients referred to a cardiology outpatient clinic for a general consultation or for electrical cardioversion. The study evaluated the ability of a wrist monitor that uses a photoplethysmography (PPG) signal and an electrocardiographic lead to automatically detect AF compared with diagnosis established by 2 cardiologists using the 12-lead electrocardiogram. RESULTS: The AF detection algorithm based on the PPG signal had a sensitivity of 91% and a specificity of 96% (diagnostic accuracy: 93%). The automatic algorithm based on the electrocardiographic signal had a sensitivity of 94% and a specificity of 96% (diagnostic accuracy: 95%). The 2 algorithms concurred in the diagnosis in 96% of the cases. Overall, the monitor had a sensitivity and specificity of 95% (diagnostic accuracy: 95% and Kappa index: 0.98). CONCLUSIONS: This study shows that automatic AF detection through the use of a heart rhythm monitor incorporating sensors and algorithms that analyze the PPG signal and the electrocardiographic signal corresponding to lead I is feasible and has high diagnostic accuracy.


Assuntos
Fibrilação Atrial , Algoritmos , Fibrilação Atrial/diagnóstico , Eletrocardiografia , Humanos , Fotopletismografia , Estudos Prospectivos , Sensibilidade e Especificidade
4.
Rev Esp Cardiol (Engl Ed) ; 65(12): 1117-32, 2012 Dec.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-23084088

RESUMO

INTRODUCTION AND OBJECTIVES: To describe the results of the analysis of pacemaker implantations reported to the Spanish Pacemaker Registry in 2011, with particular reference to the population distribution and the selection of pacing modes. METHODS: Information provided by the European Pacemaker Patient Identification Card was processed using a purpose-built computer application. RESULTS: Data from 115 hospitals were analyzed, totaling 13,373 cards, representing an estimated 38% of implantations. The number of pacemaker generators and resynchronization devices implanted was 738 and 56.2 units per million population, respectively. The mean age of the patients who received a device was 76.7 years. Overall, 57.2% of first implantations and 56.5% of replacements were performed in men. Most implantations (38.7%) and generator replacements (41.9%) were performed in patients aged between 80 and 89 years. Of the pacemaker leads used, 99.7% were bipolar and 63% used an active fixation system. Overall, 20% of the patients with atrioventricular block or sick sinus syndrome were paced in VVI/R mode despite being in sinus rhythm. CONCLUSIONS: With respect to previous years, the use of conventional pacemakers remained stable and the implantation of resynchronization devices has increased. The number of implantation procedures continues to be higher in men and in younger patients. Age and the degree of blockage remain as factors influencing the appropriate choice of pacing mode.


Assuntos
Marca-Passo Artificial/estatística & dados numéricos , Sistema de Registros , Adolescente , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Remoção de Dispositivo , Falha de Equipamento/estatística & dados numéricos , Feminino , Setor de Assistência à Saúde , Cardiopatias/terapia , Humanos , Lactente , Recém-Nascido , Masculino , Pessoa de Meia-Idade , Sistemas de Identificação de Pacientes , Fatores Sexuais , Sociedades Médicas , Espanha/epidemiologia , Adulto Jovem
5.
Rev Esp Cardiol (Engl Ed) ; 65(9): 826-34, 2012 Sep.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-22795364

RESUMO

INTRODUCTION AND OBJECTIVES: A cross-sectional study of cardiac resynchronization therapy use in Spain was performed to analyze problems with indications, implantation, and patient follow-up. METHODS: Spanish cardiac resynchronization therapy implanter centers were identified, then the department members were surveyed and the data were recorded by each implantation team. RESULTS: Eighty-eight implanter centers were identified; of these, 85 (96.6%) answered the survey. A total of 2147 device implantations were reported, comprising 85.6% of the overall number of 2518 implantations estimated by the European Confederation of Medical Suppliers Associations for the same period. The reported implantation rate was 46 per million inhabitants versus an estimated implantation rate of 51 per million (European average, 131). Cardiac resynchronization therapy devices accounted for 84% of implantations, and upgrades to previously implanted devices, 16%. The majority of cardiac resynchronization therapy devices were implanted in men (70.7%). The mean age was 68 (12) years, and the mean left ventricular ejection fraction was 26.4% (5%). Most patients (67%) were in New York Heart Association functional class III. The group of patients for whom cardiac resynchronization therapy was indicated according to the latest update of the guidelines was significant: 17.3% among New York Heart Association class II patients and more than 21.6% among patients with atrial fibrillation. In all, electrophysiologists accounted for 73.8% of implanters, followed by surgeons, accounting for 21.4%. CONCLUSIONS: The latest update of the guidelines is being progressively implemented in Spain, according to data obtained in patients in New York Heart Association class II or with atrial fibrillation. Nevertheless, the number of cardiac resynchronization therapy device implants is still well below the European average.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca/estatística & dados numéricos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/terapia , Terapia de Ressincronização Cardíaca/efeitos adversos , Contraindicações , Estudos Transversais , Feminino , Seguimentos , Pesquisas sobre Atenção à Saúde , Hospitais , Humanos , Masculino , Pessoa de Meia-Idade , Seleção de Pessoal , Consulta Remota , Espanha , Adulto Jovem
6.
ISRN Cardiol ; 2012: 907102, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22778997

RESUMO

Functional results after heart transplantation range from modest to spectacular improvement. Little is known about factors to predict functional result. This study aimed to identify these factors. We present a prospective study including all consecutive transplant recipients (n = 55) in a two-year period whose survival was greater than two months. Perioperative, donor, and recipient issues were systematically analyzed. Exercise capacity was assessed by symptom-limited treadmill exercise testing two months after transplantation. Exercise capacity was classified as satisfactory or poor depending on achieving or not 4.5 METs (metabolic equivalents), respectively. Thirty-three patients (60%) showed a good exercise capacity (>4.5 METs), whereas the remaining twenty-two patients (40%) were unable to exceed this threshold. The variables which correlated with exercise capacity in univariate analysis were recipient age, inotropic treatment, ischemic time, ventricular assist device, etiology, urgent transplant, and INTERMACS score. Among them only recipient age and ischemic time were proved to be correlated with exercise capacity in the multiple regression analysis. Thus, younger patients and those who had received an organ with shorter ischemic time showed greater exercise capacity after transplant. These findings strengthen the trend toward reducing ischemic time as much as possible to improve both survival and clinical recovery.

7.
Rev Esp Cardiol ; 64(12): 1154-67, 2011 Dec.
Artigo em Espanhol | MEDLINE | ID: mdl-22030341

RESUMO

INTRODUCTION AND OBJECTIVES: Our aim is to describe the analysis of the pacemaker implants and replacements reported to the Spanish Pacemaker Registry in 2010, with special reference to the selection of pacing modes. METHODS: Data collection was based on the information provided by the European Pacemaker Patient Identification Card, which was processed using a specially designed computer application. RESULTS: Information was received from 101 hospitals, covering a total of 11 648 cards. An estimated 738 pacemaker generators per million population were placed in 2010. The number of pacemaker implantations is higher and the mean age of the recipients lower among men. Overall, 95.5% of the pacemaker leads used were bipolar, 56% employed an active fixation system, and 60% were placed in atrium. The most common electrocardiographic indication was atrioventricular block, followed by sick sinus syndrome. Twenty-four percent of the patients with atrioventricular block and 25.6% of those with sick sinus syndrome are being paced in VVI/R mode (12% of the patients in each group are aged 80 years or under). Cardiac resynchronization device implantation has reached the level of 47 units per million population, 25.7% of which are not associated with implantable cardioverter defibrillators. CONCLUSIONS: The upward trend in the use of pacemaker generators continues. The pacemaker leads used are predominantly bipolar, and the majority are active fixation leads. Age remains a factor in the choice of the appropriate pacing mode for the different types of heart disease. This choice could be improved in more than 20% of the cases of pacemaker implantation.


Assuntos
Estimulação Cardíaca Artificial/métodos , Marca-Passo Artificial/estatística & dados numéricos , Fatores Etários , Interpretação Estatística de Dados , Setor de Assistência à Saúde , Humanos , Sistemas de Identificação de Pacientes , Sistema de Registros , Reoperação , Fatores Sexuais , Espanha
8.
Rev Esp Cardiol ; 64 Suppl 1: 91-9, 2011.
Artigo em Espanhol | MEDLINE | ID: mdl-21276495

RESUMO

This article contains a discussion of the most recent developments in cardiac resynchronization therapy, of the feasibility of performing magnetic resonance imaging in patients with cardiac pacemakers, and of the current and future status of leadless pacing. Finally, the most significant scientific articles published in the last year are reviewed.


Assuntos
Estimulação Cardíaca Artificial/tendências , Cardiologia/tendências , Marca-Passo Artificial/tendências , Terapia de Ressincronização Cardíaca , Eletrocardiografia , Cardiopatias/terapia , Humanos , Imageamento por Ressonância Magnética , Seleção de Pacientes
9.
Rev Esp Cardiol ; 63(12): 1452-67, 2010 Dec.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-21144406

RESUMO

INTRODUCTION AND OBJECTIVES: This article describes the finding of an analysis of all pacemaker implants reported to the Spanish Pacemaker Registry in 2009. Particular attention is paid to patients' demographic characteristics and to the pacing modes selected for various electrocardiographic indications. METHODS: The information provided by the European Pacemaker Identification Card was analyzed using a specially developed computer program. RESULTS: Data were received from 106 centers, covering a total of 11,939 cards and corresponding to 35% of all pacemakers implanted. The average age of patients receiving pacemakers was 76.6 years. Overall, 58.4% of pacemakers were implanted in men. The largest number of electrocardiographic indications for a pacemaker was for third-degree atrioventricular block, which comprised 56% of all atrioventricular blocks. The VVIR pacing mode was used for 24.0% of patients with sick sinus syndrome and 23.5% with atrioventricular block. Over 50% of leads employed an active fixation system, and 65% were placed in the atrium. CONCLUSIONS: The trend of increasing pacemaker use continued in 2009, reaching 729 units per million population. Pacemaker implantation was more frequent in males, who received them at a slightly younger age than women. Age was a more significant determinant of inappropriate pacing mode selection than electrocardiographic abnormalities. Active fixation of pacemaker leads was used in more than 50% of cases.


Assuntos
Marca-Passo Artificial/estatística & dados numéricos , Fatores Etários , Idoso , Bloqueio Atrioventricular/terapia , Estimulação Cardíaca Artificial , Eletrodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Fatores Sexuais , Síndrome do Nó Sinusal/terapia , Espanha/epidemiologia
10.
Rev Esp Cardiol ; 63 Suppl 1: 73-85, 2010 Jan.
Artigo em Espanhol | MEDLINE | ID: mdl-20223181

RESUMO

This review discusses the utility and current status of remote monitoring in patients with cardiac devices in Spain, the different anticoagulation strategies used during device implantation, the surgical replacement and maintenance of pacemakers and defibrillators, and the present and future importance of impedance sensors in cardiac pacing and heart failure management. Finally, there is a summary of the most relevant scientific articles published in the last year.


Assuntos
Estimulação Cardíaca Artificial , Anticoagulantes/uso terapêutico , Técnicas Biossensoriais/tendências , Impedância Elétrica , Previsões , Humanos , Monitorização Ambulatorial , Implantação de Prótese
11.
Europace ; 10(2): 161-3, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18208939

RESUMO

Pacemaker manufacturers have developed new algorithms to preserve intrinsic conduction in order to reduce unnecessary stimulation and looking for physiological pacing. This case report highlights some of the new challenges related to these algorithms which include possible ECG misinterpretations and inaccurate programming leading to potential negative consequences.


Assuntos
Bloqueio Atrioventricular/diagnóstico , Bloqueio Atrioventricular/terapia , Estimulação Cardíaca Artificial , Marca-Passo Artificial/efeitos adversos , Idoso , Algoritmos , Bloqueio Atrioventricular/fisiopatologia , Estimulação Cardíaca Artificial/efeitos adversos , Eletrocardiografia , Falha de Equipamento , Reações Falso-Positivas , Feminino , Sistema de Condução Cardíaco/fisiopatologia , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA