Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Trauma Acute Care Surg ; 78(2): 231-7; discussion 237-9, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25757106

RESUMO

BACKGROUND: Dysfunctional inflammation following traumatic hemorrhage can lead to multiple-organ failure and death. In our polytrauma swine model, lyophilized plasma (LP) reconstituted with sterile water and ascorbic acid suppressed systemic inflammation and attenuated DNA damage. However, it remains unknown whether the inflammatory response is affected by the type of fluid used to reconstitute LP. We hypothesized that common resuscitation fluids such as normal saline (LP-NS), lactated Ringer's solution (LP-LR), Hextend (LP-HX), or sterile water (LP-SW) would yield similar inflammation profiles and DNA damage following LP reconstitution and transfusion. METHODS: This was a randomized, prospective, blinded animal study. LP was reconstituted to 50% of original volume with NS, LR, HX, or SW buffered with 15-mM ascorbic acid. Forty swine were subjected to a validated model of polytrauma, hemorrhagic shock, and Grade V liver injury and resuscitated with LP. Serum interleukin 6 (IL-6), IL-10, plasma C-reactive protein, and 8-hydroxy-2-deoxyguanosine concentrations were assessed for systemic inflammation and DNA damage at baseline, 2 hours, and 4 hours following liver injury. Lung inflammation was evaluated by Real Time Polymerize Chain Reaction (RT-PCR). RESULTS: Reconstituted LP pH was similar between groups before resuscitation. IL-6 and IL-10 increased at 2 hours and 4 hours compared with baseline in all groups (p < 0.017). DNA damage increased at 2 hours and 4 hours compared with baseline and from 2 hours to 4 hours in the LP-NS, LP-LR, and LP-SW groups (all p < 0.017). Animals resuscitated with LP-HX not only demonstrated increased DNA damage at 4 hours versus baseline but also had the lowest C-reactive protein level at 2 hours and 4-hours (p < 0.017). Overall, differences between groups were similar for DNA damage and lung inflammation. CONCLUSION: Reconstitution fluid type does not affect inflammatory cytokine profiles or DNA damage following LP transfusion in this swine polytrauma model. Based on universal availability, these data suggest that sterile water is the most logical choice for LP reconstitution in humans. LEVEL OF EVIDENCE: Prognostic, level II.


Assuntos
Antioxidantes/farmacologia , Ácido Ascórbico/farmacologia , Dano ao DNA , Hidratação/métodos , Hemorragia/terapia , Fígado/lesões , Plasma , Animais , Proteína C-Reativa/análise , Modelos Animais de Doenças , Feminino , Fraturas do Fêmur/complicações , Liofilização , Hemorragia/etiologia , Concentração de Íons de Hidrogênio , Inflamação/terapia , Pulmão/efeitos dos fármacos , Estresse Oxidativo/efeitos dos fármacos , Estudos Prospectivos , Distribuição Aleatória , Reação em Cadeia da Polimerase em Tempo Real , Suínos , Água
2.
J Trauma Acute Care Surg ; 76(2): 264-1; discussion 271-2, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24458032

RESUMO

BACKGROUND: Low-volume ascorbic acid-buffered reconstituted lyophilized plasma (LP) provides logistic advantages, reduces the risks for large-volume resuscitation, modulates inflammation, and is equally effective for hemostatic resuscitation as full-volume LP. We compared the physiologic effects of resuscitation using LP reconstituted with sterile water (LP-SW), lactated Ringer's solution (LP-LR), normal saline (LP-NS), and Hextend (LP-Hx). METHODS: Plasma was collected from swine, lyophilized, and then reconstituted into four test solutions: LP-SW, LP-LR, LP-NS, or LP-Hx. Forty swine were anesthetized and subjected to a validated model of polytrauma and hemorrhagic shock (including a Grade V liver injury), then randomized to receive one of the four test solutions. Physiologic parameters, blood loss, lactate, and hematocrit were followed up. Coagulation status was evaluated using thrombelastography. Inflammatory mediator expression was evaluated by multiplex serum assay. RESULTS: Forty animals were included in the study (10 animals per group). One animal died following LP-Hx resuscitation. There was less blood loss in the LP-SW and LP-LR groups compared with the LP-NS and LP-Hx groups (p < 0.05). The LP-SW group exhibited less early coagulopathic changes by thrombelastography, and the LP-Hx group had persistently elevated international normalized ratios at the end of the study period (p < 0.05). Serum interleukin 6 was lower after 4 hours in the LP-SW group compared with LP-NS (p < 0.05). CONCLUSION: Resuscitation using low-volume LP-SW and LP-LR buffered with ascorbic acid confers an anti-inflammatory benefit and results in less blood loss. Sterile water is a safe, cost-effective, and universally available fluid for creating a low-volume hemostatic LP resuscitation solution.


Assuntos
Hidratação/métodos , Hemostasia/fisiologia , Derivados de Hidroxietil Amido/administração & dosagem , Soluções Isotônicas/administração & dosagem , Choque Hemorrágico/terapia , Cloreto de Sódio/administração & dosagem , Animais , Coagulação Sanguínea/fisiologia , Transfusão de Componentes Sanguíneos/métodos , Modelos Animais de Doenças , Feminino , Liofilização , Técnicas Hemostáticas , Coeficiente Internacional Normatizado , Volume Plasmático/fisiologia , Distribuição Aleatória , Ressuscitação/métodos , Lactato de Ringer , Sensibilidade e Especificidade , Choque Hemorrágico/mortalidade , Suínos , Água/administração & dosagem
3.
J Trauma Acute Care Surg ; 75(3): 369-75, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23928743

RESUMO

BACKGROUND: We performed this study to optimize reconstituted lyophilized plasma (LP) into a minimal volume fluid that provides effective hemostatic resuscitation for trauma while minimizing logistical limitations. METHODS: We performed a prospective, blinded animal study. Plasma was lyophilized following whole blood collection from anesthetized swine. The minimal volume needed for reconstitution was determined, and this solution was evaluated for safe infusion into the swine. Reconstituted LP was analyzed for electrolyte content, osmolarity, and coagulation factor activity. Twenty swine were anesthetized and subjected to a validated model of polytrauma and hemorrhagic shock (including a Grade V liver injury), then randomized to resuscitation with LP reconstituted to either 100% of the original plasma volume (100%LP) or the minimal volume LP fluid. Physiologic data were monitored, and blood loss and hematocrit were measured. Coagulation status was evaluated using thrombelastography. RESULTS: The minimal volume of reconstituted LP safe for infusion in swine was 50% of the original plasma volume (50%LP). The 50%LP had higher electrolyte concentrations, osmolarity, and increased coagulation factor activity levels by volume compared with 100%LP (p < 0.05). Blood loss, hematocrit, mean arterial pressure, and heart rate did not differ between animals receiving 100%LP (n = 10) or 50%LP (n = 10) at any time point (p > 0.05). International normalized ratio and thrombelastography parameters were not different between groups (R time, α angle, or maximal amplitude, p > 0.05). CONCLUSION: Resuscitation with 50%LP fluid was well tolerated and equally effective compared with 100%LP, with respect to physiologic and hemostatic properties. The smaller volume of fluid necessary to reconstitute hypertonic LP makes it logistically superior to 100%LP for first responders and may reduce adverse effects of large-volume resuscitation.


Assuntos
Hidratação/métodos , Traumatismo Múltiplo/terapia , Troca Plasmática/métodos , Ressuscitação/métodos , Choque Hemorrágico/terapia , Animais , Fatores de Coagulação Sanguínea/análise , Modelos Animais de Doenças , Feminino , Fibrinogênio/análise , Coeficiente Internacional Normatizado , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA