Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
1.
Biomedicines ; 12(6)2024 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-38927500

RESUMO

Arrhythmic risk stratification in patients with Lamin A/C gene (LMNA)-related cardiomyopathy influences clinical decisions. An implantable cardioverter defibrillator (ICD) should be considered in patients with an estimated 5-year risk of malignant ventricular arrhythmia (MVA) of ≥10%. The risk prediction score for MVA includes non-missense LMNA mutations, despite their role as an established risk factor for sudden cardiac death (SCD) has been questioned in several studies. The purpose of this study is to investigate cardiac features and find gene-phenotype correlations that would contribute to the evidence on the prognostic implications of non-missense vs. missense mutations in a cohort of LMNA mutant patients. An observational, prospective study was conducted in which 54 patients positive for a Lamin A/C mutation were enrolled, and 20 probands (37%) were included. The median age at first clinical manifestation was 41 (IQR 19) years. The median follow-up was 8 years (IQR 8). The type of LMNA gene mutation was distributed as follows: missense in 26 patients (48%), non-frameshift insertions in 16 (30%), frameshift deletions in 5 (9%), and nonsense in 7 (13%). Among the missense mutation carriers, two (8%) died and four (15%) were admitted onto the heart transplant list or underwent transplantation, with a major adverse cardiovascular event (MACE) rate of 35%. No statistically significant differences in MACE prevalence were identified according to the missense and non-missense mutation groups (p value = 0.847). Our data shift the spotlight on this considerable topic and could suggest that some missense mutations may deserve attention regarding SCD risk stratification in real-world clinical settings.

2.
J Clin Med ; 13(9)2024 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-38731153

RESUMO

Cardiomyopathies (CMPs) are a group of myocardial disorders that are characterized by structural and functional abnormalities of the heart muscle. These abnormalities occur in the absence of coronary artery disease (CAD), hypertension, valvular disease, and congenital heart disease. CMPs are an increasingly important topic in the field of cardiovascular diseases due to the complexity of their diagnosis and management. In 2023, the ESC guidelines on cardiomyopathies were first published, marking significant progress in the field. The growth of techniques such as cardiac magnetic resonance imaging (CMR) and genetics has been fueled by the development of multimodal imaging approaches. For the diagnosis of CMPs, a multimodal imaging approach, including CMR, is recommended. CMR has become the standard for non-invasive analysis of cardiac morphology and myocardial function. This document provides an overview of the role of CMR in CMPs, with a focus on tissue mapping. CMR enables the characterization of myocardial tissues and the assessment of cardiac functions. CMR sequences and techniques, such as late gadolinium enhancement (LGE) and parametric mapping, provide detailed information on tissue composition, fibrosis, edema, and myocardial perfusion. These techniques offer valuable insights for early diagnosis, prognostic evaluation, and therapeutic guidance of CMPs. The use of quantitative CMR markers enables personalized treatment plans, improving overall patient outcomes. This review aims to serve as a guide for the use of these new tools in clinical practice.

3.
Heart Rhythm ; 2024 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-38493989

RESUMO

BACKGROUND: Atrial high-rate episodes (AHREs) are frequent in patients with cardiac implantable electronic devices. A decrease in device-detected P-wave amplitude may be an indicator of periods of increased risk of AHRE. OBJECTIVE: The objective of this study was to assess the association between P-wave amplitude and AHRE incidence. METHODS: Remote monitoring data from 2579 patients with no history of atrial fibrillation (23% pacemakers and 77% implantable cardioverter-defibrillators, of which 40% provided cardiac resynchronization therapy) were used to calculate the mean P-wave amplitude during 1 month after implantation. The association with AHRE incidence according to 4 strata of daily burden duration (≥15 minutes, ≥6 hours, ≥24 hours, ≥7 days) was investigated by adjusting the hazard ratio with the CHA2DS2-VASc score. RESULTS: The adjusted hazard ratio for 1-mV lower mean P-wave amplitude during the first month increased from 1.10 (95% confidence interval [CI], 1.05-1.15; P < .001) to 1.18 (CI, 1.09-1.28; P < .001) with AHRE duration strata from ≥15 minutes to ≥7 days independent of the CHA2DS2-VASc score. Of 871 patients with AHREs, those with 1-month P-wave amplitude <2.45 mV had an adjusted hazard ratio of 1.51 (CI, 1.19-1.91; P = .001) for progression of AHREs from ≥15 minutes to ≥7 days compared with those with 1-month P-wave amplitude ≥2.45 mV. Device-detected P-wave amplitudes decreased linearly during the 1 year before the first AHRE by 7.3% (CI, 5.1%-9.5%; P < .001 vs patients without AHRE). CONCLUSION: Device-detected P-wave amplitudes <2.45 mV were associated with an increased risk of AHRE onset and progression to persistent forms of AHRE independent of the patient's risk profile.

4.
Telemed J E Health ; 30(5): 1499-1503, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38294864

RESUMO

Telemedicine and remote monitoring devices, including implantable loop recorders (ILR), are increasingly adopted in the cardiologic setting. These are valuable tools in the arrhythmic stratification of patients at risk of sudden cardiac death, providing a tailored therapeutic management to prevent lethal arrhythmias. We report a case of an asymptomatic 18-year-old boy with a family history of syncope and cardiac arrest, who had a diagnosis of Brugada syndrome with an inducible type 1 pattern and carrier of a missense mutation of the SCN5A gene. In light of the risk factors, although not recommended by current guidelines, we decided to proceed with the implantation of an ILR with remote monitoring service. A few months later, an episode of asymptomatic sustained polymorphic ventricular tachycardia was promptly observed by the remote monitoring, leading to a timely implantation of a subcutaneous cardiac implantable defibrillator.


Assuntos
Síndrome de Brugada , Desfibriladores Implantáveis , Telemedicina , Humanos , Masculino , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/genética , Síndrome de Brugada/terapia , Adolescente , Telemedicina/métodos , Medição de Risco/métodos , Canal de Sódio Disparado por Voltagem NAV1.5/genética , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Eletrocardiografia , Eletrocardiografia Ambulatorial/instrumentação , Eletrocardiografia Ambulatorial/métodos , Mutação de Sentido Incorreto , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/etiologia
5.
Future Cardiol ; 20(1): 21-25, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38223918

RESUMO

Aim: Micra AV represents a leadless endocardial pacing system able to detect atrial contractions providing atrioventricular synchrony. A reduction of myocardial contractility may be detected in case of first-degree atrioventricular block (AVB). Materials & methods: In six patients with first-degree AVB (PQ interval ≥220 msec) was evaluated the left ventricle global longitudinal strain (LV GLS) by speckle tracking (ST) echocardiography during single-lead atrial sensing ventricular pacing (VDD) stimulation as compared with spontaneous rhythm (SR), 24-48 h after Micra AV implantation. Results: A statistically significant difference between the two modalities was observed (LV GLS during SR: -14.7% [interquartile range (IQR) 5.5], LV GLS during VDD pacing: -16.1% [IQR 5.2]; p value = 0.041). Conclusion: Our preliminary results suggest an improvement of myocardial contractility with VDD pacing as compared with SR.


What is this article about? The Micra AV is an electronic device placed in the heart chambers capable to supply the electrical activity of the heart. A reduction of cardiac contractility may be observed in patients with electrical disorders of the heart. What were the results? In six patients affected by electrical cardiac disorders, we observed an improvement of cardiac contractility using Micra AV as compared with the spontaneous electrical activity of the heart. What do the results of the study mean? The results of this study suggest that in patients carrying this electronic device should be preferred a specific modality of activation of the device as compared with the spontaneous electrical activity of the heart in order to improve the contractility of the cardiac walls.


Assuntos
Bloqueio Atrioventricular , Defeitos dos Septos Cardíacos , Marca-Passo Artificial , Humanos , Ventrículos do Coração/diagnóstico por imagem , Estimulação Cardíaca Artificial/métodos , Bloqueio Atrioventricular/terapia , Átrios do Coração/diagnóstico por imagem
6.
Heart Rhythm ; 21(5): 555-561, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38242222

RESUMO

BACKGROUND: There are limited real-world data on the extended prognosis of patients with drug-induced type 1 Brugada electrocardiogram (ECG). OBJECTIVE: We assessed the clinical outcomes and predictors of life-threatening arrhythmias in patients with drug-induced type 1 Brugada ECG. METHODS: This multicenter retrospective study, conducted at 21 Italian and Swiss hospitals from July 1997 to May 2021, included consecutive patients with drug-induced type 1 ECG. The primary outcome, a composite of appropriate ICD therapies and sudden cardiac death, was assessed along with the clinical predictors of these events. RESULTS: A total of 606 patients (mean age 49.7 ± 14.7 years; 423 [69.8%] men) were followed for a median of 60.3 months (interquartile range 23.0-122.4 months). Nineteen patients (3.1%) experienced life-threatening arrhythmias, with a median annual event rate of 0.5% over 5 years and 0.25% over 10 years. The SCN5A mutation was the only predictor of the primary outcome (hazard ratio 4.54; P = .002), whereas a trend was observed for unexplained syncope (hazard ratio 3.85; P = .05). In patients who were asymptomatic at presentation, the median annual rate of life-threatening arrhythmias is 0.24% over 5 years and increases to 1.2% if they have inducible ventricular fibrillation during programmed ventricular stimulation. CONCLUSION: In patients with drug-induced type 1 Brugada ECG, the annual risk of life-threatening arrhythmias is low, with the SCN5A mutation as the only independent predictor. Unexplained syncope correlated with worse clinical outcomes. Ventricular fibrillation inducibility at programmed ventricular stimulation significantly increases the median annual rate of life-threatening arrhythmias from 0.24% to 1.2% over 5 years.


Assuntos
Síndrome de Brugada , Eletrocardiografia , Sistema de Registros , Humanos , Masculino , Síndrome de Brugada/fisiopatologia , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/epidemiologia , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Prognóstico , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Itália/epidemiologia , Seguimentos , Desfibriladores Implantáveis , Suíça/epidemiologia , Fatores de Tempo , Taxa de Sobrevida/tendências , Adulto
7.
J Cardiovasc Electrophysiol ; 35(1): 155-161, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38010993

RESUMO

INTRODUCTION: The importance of atrio-ventricular synchrony pacing in sinus rhythm patients is known. To identify patients in whom leadless pacemakers are able to guarantee this atrio-ventricular synchrony, we explored correlations among echocardiographic measures of left atrial (LA) size and function (doppler parameter and strain) with A4 amplitude in patients implanted with new generation Micra-AV device. METHODS: After implantation with Micra-AV system, patients underwent device interrogation to evaluate AV synchrony based on the sensing of atrial mechanics and echocardiographic exam to assess LA morphology and LA function. RESULTS: In the 21 studied patients (14 males, 72 ± 13 years), the A4 wave amplitude values inversely correlated with LA antero-posterior diameter, LA volume, LA contraction strain and LA conduit strain, while they were positively related with LA reservoir strain. DISCUSSION: Our results indicate a statistically significant relationship between morphological echocardiographic LA parameters and atrial contraction signal (A4), detected by leadless pacemakers and used to synchronize ventricular pacing with the atrium. Instantaneous LA function assessment obtained with LA strain provides incremental information over morphological parameters. LA strain evaluates atrial myocardial deformation during the whole cardiac cycle. We found higher value of A4 in patients that have grater absolute value of LAsr, LAscd and LAsct, that are simple and measurable parameters of LA functional capacity. CONCLUSION: Preimplant echocardiographic evaluation of the atrial contractility may be useful in predicting adequate A4 sensing and consequently a good atrio-ventricular synchrony pacing. Echocardiography LA strain study seems promising in Micra-AV patient selection.


Assuntos
Átrios do Coração , Marca-Passo Artificial , Masculino , Humanos , Átrios do Coração/diagnóstico por imagem , Ventrículos do Coração , Ecocardiografia , Arritmias Cardíacas
8.
Pacing Clin Electrophysiol ; 47(2): 256-259, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-37208974

RESUMO

INTRODUCTION: Micra AV Transcatheter Pacing System (TPS) represents an innovative second-generation leadless pacemaker which represents an effective alternative to conventional devices in selected cases. Intrinsic malfunctions of these devices are rare, requiring sometimes their retrieval. When performed in experienced centers, this procedure is safe. CASE PRESENTATION: We describe a case of sudden battery malfunction of a Micra AV TPS, which required the extraction and the placement of a new pacing system in the right ventricle. DISCUSSION: This case, which has never been reported, highlights the need to a careful fluoroscopic evaluation and the usefulness of remote monitoring.


Assuntos
Arritmias Cardíacas , Marca-Passo Artificial , Humanos , Resultado do Tratamento , Desenho de Equipamento , Marca-Passo Artificial/efeitos adversos , Estimulação Cardíaca Artificial
9.
J Clin Med ; 12(24)2023 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-38137821

RESUMO

Non-ischemic dilated cardiomyopathy (DCM) is a disease characterized by left ventricular dilation and systolic dysfunction. Patients with DCM are at higher risk for ventricular arrhythmias and sudden cardiac death (SCD). According to current international guidelines, left ventricular ejection fraction (LVEF) ≤ 35% represents the main indication for prophylactic implantable cardioverter defibrillator (ICD) implantation in patients with DCM. However, LVEF lacks sensitivity and specificity as a risk marker for SCD. It has been seen that the majority of patients with DCM do not actually benefit from the ICD implantation and, on the contrary, that many patients at risk of SCD are not identified as they have preserved or mildly depressed LVEF. Therefore, the use of LVEF as unique decision parameter does not maximize the benefit of ICD therapy. Multiple risk factors used in combination could likely predict SCD risk better than any single risk parameter. Several predictors have been proposed including genetic variants, electric indexes, and volumetric parameters of LV. Cardiac magnetic resonance (CMR) can improve risk stratification thanks to tissue characterization sequences such as LGE sequence, parametric mapping, and feature tracking. This review evaluates the role of CMR as a risk stratification tool in DCM patients referred for ICD.

10.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37656991

RESUMO

AIMS: The HeartLogic Index combines data from multiple implantable cardioverter defibrillators (ICDs) sensors and has been shown to accurately stratify patients at risk of heart failure (HF) events. We evaluated and compared the performance of this algorithm during sinus rhythm and during long-lasting atrial fibrillation (AF). METHODS AND RESULTS: HeartLogic was activated in 568 ICD patients from 26 centres. We found periods of ≥30 consecutive days with an atrial high-rate episode (AHRE) burden <1 h/day and periods with an AHRE burden ≥20 h/day. We then identified patients who met both criteria during the follow-up (AHRE group, n = 53), to allow pairwise comparison of periods. For control purposes, we identified patients with an AHRE burden <1 h throughout their follow-up and implemented 2:1 propensity score matching vs. the AHRE group (matched non-AHRE group, n = 106). In the AHRE group, the rate of alerts was 1.2 [95% confidence interval (CI): 1.0-1.5]/patient-year during periods with an AHRE burden <1 h/day and 2.0 (95% CI: 1.5-2.6)/patient-year during periods with an AHRE-burden ≥20 h/day (P = 0.004). The rate of HF hospitalizations was 0.34 (95% CI: 0.15-0.69)/patient-year during IN-alert periods and 0.06 (95% CI: 0.02-0.14)/patient-year during OUT-of-alert periods (P < 0.001). The IN/OUT-of-alert state incidence rate ratio of HF hospitalizations was 8.59 (95% CI: 1.67-55.31) during periods with an AHRE burden <1 h/day and 2.70 (95% CI: 1.01-28.33) during periods with an AHRE burden ≥20 h/day. In the matched non-AHRE group, the rate of HF hospitalizations was 0.29 (95% CI: 0.12-0.60)/patient-year during IN-alert periods and 0.04 (95% CI: 0.02-0.08)/patient-year during OUT-of-alert periods (P < 0.001). The incidence rate ratio was 7.11 (95% CI: 2.19-22.44). CONCLUSION: Patients received more alerts during periods of AF. The ability of the algorithm to identify increased risk of HF events was confirmed during AF, despite a lower IN/OUT-of-alert incidence rate ratio in comparison with non-AF periods and non-AF patients. CLINICAL TRIAL REGISTRATION: http://clinicaltrials.gov/Identifier: NCT02275637.


Assuntos
Fibrilação Atrial , Desfibriladores Implantáveis , Insuficiência Cardíaca , Humanos , Algoritmos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/terapia , Átrios do Coração , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/terapia
11.
Heart Rhythm ; 20(2): 233-240, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-37283031

RESUMO

BACKGROUND: Elevated resting heart rate is a risk factor for cardiovascular events. OBJECTIVE: The purpose of this study was to investigate the clinical significance of nocturnal heart rate (nHR) and 24-hour mean heart rate (24h-HR) obtained by continuous remote monitoring (RM) of implantable devices. METHODS: We analyzed daily-sampled trends of nHR, 24h-HR, and physical activity in patients on ß-blocker therapy for chronic heart failure and with implantable cardioverter-defibrillators or cardiac resynchronization therapy defibrillators (CRT-Ds). Patients were grouped by average nHR and 24h-HR quartile during follow-up to estimate the respective incidence of nonarrhythmic death and device-treated ventricular tachycardia/fibrillation (VT/VF). RESULTS: The study cohort included 1330 patients (median age 69 years [interquartile range 61-77 years]; 41% [n = 550] with CRT-D; median follow-up 25 months [interquartile range 13-42 months]). Compared with patients in the lowest nHR quartile (≤57 beats/min) group, patients in the highest quartile group (>65 beats/min) had an increased risk of nonarrhythmic death (adjusted hazard ratio [AHR] 2.25; 95% confidence interval [CI] 1.13-4.50; P = .021) and VT/VF (AHR 1.98; 95% CI 1.40-2.79; P < .001) and were characterized by the lowest level of physical activity (P ≤ .0004 vs every other nHR quartiles). The highest 24h-HR quartile group (>75 beats/min) showed an increased risk of VT/VF (AHR 2.13; 95% CI 1.52-2.99; P < .001) and a weaker though significant association with nonarrhythmic mortality (AHR 1.80; 95% CI 1.00-3.22; P = .05) as compared with the lowest 24h-HR quartile group (≤65 beats/min). CONCLUSION: In remotely monitored patients with implantable cardioverter-defibrillator/CRT-D on ß-blocker therapy for heart failure, elevated heart rates (nHR >65 beats/min and 24h-HR >75 beats/min) were associated with increased mortality and VT/VF risk. nHR showed a stronger association than 24h-HR with worst prognosis and lowest physical activity.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Insuficiência Cardíaca , Taquicardia Ventricular , Disfunção Ventricular Esquerda , Humanos , Pessoa de Meia-Idade , Idoso , Frequência Cardíaca , Prognóstico , Volume Sistólico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/terapia , Fibrilação Ventricular/terapia , Arritmias Cardíacas/terapia , Fatores de Risco , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Terapia de Ressincronização Cardíaca/efeitos adversos , Desfibriladores Implantáveis/efeitos adversos , Disfunção Ventricular Esquerda/complicações
12.
ESC Heart Fail ; 10(4): 2469-2478, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37278122

RESUMO

AIMS: The HeartLogic algorithm combines multiple implantable defibrillator (ICD) sensor data and has proved to be a sensitive and timely predictor of impending heart failure (HF) decompensation in cardiac resynchronization therapy (CRT-D) patients. We evaluated the performance of this algorithm in non-CRT ICD patients and in the presence of co-morbidities. METHODS AND RESULTS: The HeartLogic feature was activated in 568 ICD patients (410 with CRT-D) from 26 centres. The median follow-up was 26 months [25th-75th percentile: 16-37]. During follow-up, 97 hospitalizations were reported (53 cardiovascular) and 55 patients died. We recorded 1200 HeartLogic alerts in 370 patients. Overall, the time IN the alert state was 13% of the total observation period. The rate of cardiovascular hospitalizations or death was 0.48/patient-year (95% CI: 0.37-0.60) with the HeartLogic IN the alert state and 0.04/patient-year (95% CI: 0.03-0.05) OUT of the alert state, with an incidence rate ratio of 13.35 (95% CI: 8.83-20.51, P < 0.001). Among patient characteristics, atrial fibrillation (AF) on implantation (HR: 1.62, 95% CI: 1.27-2.07, P < 0.001) and chronic kidney disease (CKD) (HR: 1.53, 95% CI: 1.21-1.93, P < 0.001) independently predicted alerts. HeartLogic alerts were not associated with CRT-D versus ICD implantation (HR: 1.03, 95% CI: 0.82-1.30, P = 0.775). Comparisons of the clinical event rates in the IN alert state with those in the OUT of alert state yielded incidence rate ratios ranging from 9.72 to 14.54 (all P < 0.001) in all groups of patients stratified by: CRT-D/ICD, AF/non-AF, and CKD/non-CKD. After multivariate correction, the occurrence of alerts was associated with cardiovascular hospitalization or death (HR: 1.92, 95% CI: 1.05-3.51, P = 0.036). CONCLUSIONS: The burden of HeartLogic alerts was similar between CRT-D and ICD patients, while patients with AF and CKD seemed more exposed to alerts. Nonetheless, the ability of the HeartLogic algorithm to identify periods of significantly increased risk of clinical events was confirmed, regardless of the type of device and the presence of AF or CKD.


Assuntos
Fibrilação Atrial , Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Insuficiência Cardíaca , Humanos , Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/terapia , Fibrilação Atrial/etiologia , Algoritmos , Morbidade
13.
Europace ; 25(4): 1467-1474, 2023 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-36881780

RESUMO

AIMS: Patients with atrial fibrillation frequently experience sleep disorder breathing, and both conditions are highly prevalent in presence of heart failure (HF). We explored the association between the combination of an HF and a sleep apnoea (SA) index and the incidence of atrial high-rate events (AHRE) in patients with implantable defibrillators (ICDs). METHODS AND RESULTS: Data were prospectively collected from 411 consecutive HF patients with ICD. The IN-alert HF state was measured by the multi-sensor HeartLogic Index (>16), and the ICD-measured Respiratory Disturbance Index (RDI) was computed to identify severe SA. The endpoints were as follows: daily AHRE burden of ≥5 min, ≥6 h, and ≥23 h. During a median follow-up of 26 months, the time IN-alert HF state was 13% of the total observation period. The RDI value was ≥30 episodes/h (severe SA) during 58% of the observation period. An AHRE burden of ≥5 min/day was documented in 139 (34%) patients, ≥6 h/day in 89 (22%) patients, and ≥23 h/day in 68 (17%) patients. The IN-alert HF state was independently associated with AHRE regardless of the daily burden threshold: hazard ratios from 2.17 for ≥5 min/day to 3.43 for ≥23 h/day (P < 0.01). An RDI ≥ 30 episodes/h was associated only with AHRE burden ≥5 min/day [hazard ratio 1.55 (95% confidence interval: 1.11-2.16), P = 0.001]. The combination of IN-alert HF state and RDI ≥ 30 episodes/h accounted for only 6% of the follow-up period and was associated with high rates of AHRE occurrence (from 28 events/100 patient-years for AHRE burden ≥5 min/day to 22 events/100 patient-years for AHRE burden ≥23 h/day). CONCLUSIONS: In HF patients, the occurrence of AHRE is independently associated with the ICD-measured IN-alert HF state and RDI ≥ 30 episodes/h. The coexistence of these two conditions occurs rarely but is associated with a very high rate of AHRE occurrence. CLINICAL TRIAL REGISTRATION: URL: http://clinicaltrials.gov/Identifier: NCT02275637.


Assuntos
Fibrilação Atrial , Desfibriladores Implantáveis , Insuficiência Cardíaca , Síndromes da Apneia do Sono , Humanos , Desfibriladores Implantáveis/efeitos adversos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/terapia , Medição de Risco , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/terapia
14.
J Cardiovasc Electrophysiol ; 34(5): 1257-1267, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36994907

RESUMO

INTRODUCTION: The prediction of ventricular tachyarrhythmias among patients with implantable cardioverter defibrillators is difficult with available clinical tools. We sought to assess whether in patients with heart failure (HF) and reduced ejection fraction with defibrillators, physiological sensor-based HF status, as summarized by the HeartLogic index, could predict appropriate device therapies. METHODS: Five hundred and sixty-eight consecutive HF patients with defibrillators (n = 158, 28%) or cardiac resynchronization therapy-defibrillators (n = 410, 72%) were included in this prospective observational multicenter analysis. The association of both HeartLogic index and its physiological components with defibrillator shocks and overall appropriate therapies was assessed in regression and time-dependent Cox models. RESULTS: Over a follow-up of 25 (15-35) months, 122 (21%) patients received an appropriate device therapy (shock, n = 74, 13%), while the HeartLogic index crossed the threshold value (alert, HeartLogic ≥ 16) 1200 times (0.71 alerts/patient-year) in 370 (65%) subjects. The occurrence of ≥1 HeartLogic alert was significantly associated with both appropriate shocks (Hazard ratios [HR]: 2.44, 95% confidence interval [CI]: 1.49-3.97, p = .003), and any appropriate defibrillator therapies. In multivariable time-dependent Cox models, weekly IN-alert state was the strongest predictor of appropriate defibrillator shocks (HR: 2.94, 95% CI: 1.73-5.01, p < .001) and overall therapies. Compared with stable patients, patients with appropriate shocks had significantly higher values of HeartLogic index, third heart sound amplitude, and resting heart rate 30-60 days before device therapy. CONCLUSION: The HeartLogic index is an independent dynamic predictor of appropriate defibrillator therapies. The combined index and its individual physiological components change before the arrhythmic event occurs.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Insuficiência Cardíaca , Taquicardia Ventricular , Disfunção Ventricular Esquerda , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Taquicardia Ventricular/complicações , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/complicações , Terapia de Ressincronização Cardíaca/efeitos adversos , Disfunção Ventricular Esquerda/terapia
15.
Heart Rhythm ; 20(7): 992-997, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36966948

RESUMO

BACKGROUND: The HeartLogic algorithm (Boston Scientific) has proved to be a sensitive and timely predictor of impending heart failure (HF) decompensation. OBJECTIVE: The purpose of this study was to determine whether remotely monitored data from this algorithm could be used to identify patients at high risk for mortality. METHODS: The algorithm combines implantable cardioverter-defibrillator (ICD)-measured accelerometer-based heart sounds, intrathoracic impedance, respiration rate, ratio of respiration rate to tidal volume, night heart rate, and patient activity into a single index. An alert is issued when the index crosses a programmable threshold. The feature was activated in 568 ICD patients from 26 centers. RESULTS: During median follow-up of 26 months [25th-75th percentile 16-37], 1200 alerts were recorded in 370 patients (65%). Overall, the time IN-alert state was 13% of the total observation period (151/1159 years) and 20% of the follow-up period of the 370 patients with alerts. During follow-up, 55 patients died (46 in the group with alerts). The rate of death was 0.25 per patient-year (95% confidence interval [CI] 0.17-0.34) IN-alert state and 0.02 per patient-year (95% CI 0.01-0.03) OUT of the alert state, with an incidence rate ratio of 13.72 (95% CI 7.62-25.60; P <.001). After multivariate correction for baseline confounders (age, ischemic cardiomyopathy, kidney disease, atrial fibrillation), the IN-alert state remained significantly associated with the occurrence of death (hazard ratio 9.18; 95% CI 5.27-15.99; P <.001). CONCLUSION: The HeartLogic algorithm provides an index that can be used to identify patients at higher risk for all-cause mortality. The index state identifies periods of significantly increased risk of death.


Assuntos
Fibrilação Atrial , Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Insuficiência Cardíaca , Humanos , Terapia de Ressincronização Cardíaca/efeitos adversos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/etiologia , Fibrilação Atrial/terapia , Algoritmos
16.
Expert Rev Cardiovasc Ther ; 21(3): 151-164, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36847583

RESUMO

INTRODUCTION: The subcutaneous implantable cardioverter-defibrillator (S-ICD) is an established therapy for the prevention of sudden cardiac death (SCD) and an alternative to a transvenous implantable cardioverter-defibrillator system in selected patients. Beyond randomized clinical trials, many observational studies have described the clinical performance of S-ICD across different subgroups of patients. AREAS COVERED: Our review aimed to describe the opportunities and drawbacks of the S-ICD, focusing on their use in special populations and across different clinical settings. EXPERT OPINION: The choice to implant S-ICD should be based on the patient's tailored approach, which takes into account the adequate S-ICD screening at rest or during stress, the infective risk, the ventricular arrhythmia susceptibility, the progressive nature of the underlying disease, the work or sports activity, and the risk of lead-related complications.


Assuntos
Arritmias Cardíacas , Desfibriladores Implantáveis , Humanos , Resultado do Tratamento , Arritmias Cardíacas/diagnóstico , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/efeitos adversos , Cardioversão Elétrica/efeitos adversos
18.
Heart Vessels ; 38(5): 680-688, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36418560

RESUMO

No real-world data are available about the complications rate in drug-induced type 1 Brugada Syndrome (BrS) patients with an implantable cardioverter-defibrillator (ICD). Aim of our study is to compare the device-related complications, infections, and inappropriate therapies among drug-induced type 1 BrS patients with transvenous- ICD (TV-ICD) versus subcutaneous-ICD (S-ICD). Data for this study were sourced from the IBRYD (Italian BRugada sYnDrome) registry which includes 619 drug-induced type-1 BrS patients followed at 20 Italian tertiary referral hospitals. For the present analysis, we selected 258 consecutive BrS patients implanted with ICD. 198 patients (76.7%) received a TV-ICD, while 60 a S-ICD (23.4%). And were followed-up for a median time of 84.3 [46.5-147] months. ICD inappropriate therapies were experienced by 16 patients (6.2%). 14 patients (7.1%) in the TVICD group and 2 patients (3.3%) in S-ICD group (log-rank P = 0.64). ICD-related complications occurred in 31 patients (12%); 29 (14.6%) in TV-ICD group and 2 (3.3%) in S-ICD group (log-rank P = 0.41). ICD-related infections occurred in 10 patients (3.88%); 9 (4.5%) in TV-ICD group and 1 (1.8%) in S-ICD group (log-rank P = 0.80). After balancing for potential confounders using the propensity score matching technique, no differences were found in terms of clinical outcomes between the two groups. In a real-world setting of drug-induced type-1 BrS patients with ICD, no significant differences in inappropriate ICD therapies, device-related complications, and infections were shown among S-ICD vs TV-ICD. However, a reduction in lead-related complications was observed in the S-ICD group. In conclusion, our evidence suggests that S-ICD is at least non-inferior to TV-ICD in this population and may also reduce the risk of lead-related complications which can expose the patients to the necessity of lead extractions.


Assuntos
Síndrome de Brugada , Desfibriladores Implantáveis , Humanos , Desfibriladores Implantáveis/efeitos adversos , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/terapia , Síndrome de Brugada/etiologia , Pontuação de Propensão , Cardioversão Elétrica/efeitos adversos , Eletrocardiografia/métodos , Morte Súbita Cardíaca/epidemiologia , Resultado do Tratamento
19.
JACC Clin Electrophysiol ; 8(12): 1553-1562, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36543505

RESUMO

BACKGROUND: Causes of sex differences in incidence of sustained ventricular arrhythmias (SVAs) are poorly understood. OBJECTIVES: This study aims to investigate sex-specific risk of SVAs and device therapies by balancing sex groups in relation to several baseline characteristics with the propensity score (PS). METHODS: We used a large remote monitoring dataset from implantable cardioverter-defibrillators (ICDs) and cardiac resynchronization therapy defibrillators (CRT-Ds). Study endpoints were time to the first appropriate SVA, time to the first device therapy for SVA, and time to the first ICD shock. Results were compared between females and a PS-matched male subgroup. RESULTS: In a cohort of 2,532 patients with an ICD or CRT-D (median age, 70 years), 488 patients (19.3%) were women. After selecting 488 men PS-matched for 19 variables relative to baseline demographics, implant indications, principal comorbidities, and concomitant therapy, yet the SVA rate at the 2.1-year median follow-up was significantly lower in women than in man (adjusted HR: 0.65; 95% CI: 0.51-0.81; P < 0.001). Women also showed a reduced risk of any device therapy (HR: 0.59; 95% CI: 0.45-0.76; P < 0.001) and shocks (HR: 0.66; 95% CI: 0.47-0.94; P = 0.021). Differences in sex-specific SVA risk profile were not confirmed in CRT-D patients (HR: 0.78; 95% CI: 0.55-1.09; P = 0.14) nor in those with an ejection fraction <30% (HR: 0.80; 95% CI: 0.52-1.23; P = 0.31). CONCLUSIONS: After matching demographics, indications, principal comorbidities, and concomitant therapy, women still exhibited a lower SVA risk profile than men, except in the subgroups of CRT-D or/and ejection fraction <30%.


Assuntos
Desfibriladores Implantáveis , Humanos , Masculino , Feminino , Idoso , Desfibriladores Implantáveis/efeitos adversos , Pontuação de Propensão , Resultado do Tratamento , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/terapia , Cardioversão Elétrica
20.
JACC Clin Electrophysiol ; 8(10): 1249-1256, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36266001

RESUMO

BACKGROUND: Sleep-disordered breathing is highly prevalent in heart failure (HF) and has been suggested as a risk factor for malignant ventricular arrhythmias. The Respiratory Disturbance Index (RDI) computed by an implantable cardioverter-defibrillator (ICD) algorithm accurately identifies severe sleep apnea. OBJECTIVES: In the present analysis, the authors evaluated the association between ICD-detected sleep apnea and the incidence of appropriate ICD therapies in patients with HF. METHODS: We enrolled 411 HF patients who had received an ICD endowed with an algorithm that calculates the RDI each night. In this analysis, the weekly mean RDI value was considered. The endpoint was the first appropriate ICD shock. RESULTS: The median follow-up was 26 months (25th to 75th percentile: 16-35 months). During follow-up, 1 or more ICD shocks were documented in 58 (14%) patients. Patients with shocks were younger (age 66 ± 13 years vs 70 ± 10 years; P = 0.038), and had more frequently undergone implantation for secondary prevention (21% vs 10%; P = 0.026). The maximum RDI value calculated during the entire follow-up period did not differ between patients with and without shocks (55 ± 15 episodes/h vs 54 ± 14 episodes/h; P = 0.539). However, the ICD-detected RDI showed considerable variability during follow-up. The overall median of the weekly RDI was 33 episodes/h (25th to 75th percentile: 24-45 episodes/h). A time-dependent Cox regression model revealed that a continuously measured weekly mean RDI of ≥45 episodes/h was independently associated with shock occurrence (HR: 4.63; 95% CI: 2.54-8.43; P < 0.001), after correction for baseline confounders (age, secondary prevention). CONCLUSIONS: In HF patients, appropriate ICD shocks were more likely to be delivered during periods when patients exhibited more sleep-disordered breathing. (Arrhythmias Detection in a Real World Population [RHYTHM DETECT]; NCT02275637).


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca , Síndromes da Apneia do Sono , Idoso , Humanos , Pessoa de Meia-Idade , Arritmias Cardíacas/epidemiologia , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/terapia , Síndromes da Apneia do Sono/diagnóstico , Síndromes da Apneia do Sono/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA