Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 52
Filtrar
1.
Minerva Urol Nephrol ; 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38727672

RESUMO

BACKGROUND: Stone nomogram by Micali et al., able topredict treatment failure of shock-wave lithotripsy (SWL), retrograde intrarenal surgery (RIRS) and percutaneous nephrolithotomy (PNL) in the management of single 1-2 cm renal stones, was developed on 2605 patients and showed a high predictive accuracy, with an area under ROC curve of 0.793 at internal validation. The aim of the present study is to externally validate the model to assess whether it displayed a satisfactory predictive performance if applied to different populations. METHODS: External validation was retrospectively performed on 3025 patients who underwent an active stone treatment from December 2010 to June 2021 in 26 centers from four countries (Italy, USA, Spain, Argentina). Collected variables included: age, gender, previous renal surgery, preoperative urine culture, hydronephrosis, stone side, site, density, skin-to-stone distance. Treatment failure was the defined outcome (residual fragments >4 mm at three months CT-scan). RESULTS: Model discrimination in external validation datasets showed an area under ROC curve of 0.66 (95% 0.59-0.68) with adequate calibration. The retrospective fashion of the study and the lack of generalizability of the tool towards populations from Asia, Africa or Oceania represent limitations of the current analysis. CONCLUSIONS: According to the current findings, Micali's nomogram can be used for treatment prediction after SWL, RIRS and PNL; however, a lower discrimination performance than the one at internal validation should be acknowledged, reflecting geographical, temporal and domain limitation of external validation studies. Further prospective evaluation is required to refine and improve the nomogram findings and to validate its clinical value.

5.
World J Urol ; 42(1): 31, 2024 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-38217724

RESUMO

INTRODUCTION: Versius CMR is a novel robotic system characterized by an open surgical console and independent bedside units. The system has potentials of flexibility and versatility, and has been used in urological, gynecological, and general surgical procedure. The aim is to depict a comprehensive analysis of the Versius system for pelvic surgery. METHODS: This is a study involving two Institutions, ASST Santi Paolo and Carlo, Milan, and Apuane Hospital, Massa, Italy. All interventions performed in the pelvic area with the Versius were included. Data about indications, intra-, and post-operative course were prospectively collected and analyzed. RESULTS: A total of 171 interventions were performed with the Versius. Forty-two of them involved pelvic procedures. Twenty-two had an oncological indication (localized prostate cancer), the remaining had a non-oncological or functional purpose. The mostly performed pelvic procedure was radical prostatectomy (22) followed by annexectomy (9). No intra-operative complication nor conversion to other approaches occurred. A Clavien II complication and one Clavien IIIb were reported. Malfunctioning/alarms requiring a power cycle of the system occurred in 2 different cases. An adjustment in trocar placement according to patients' height was required in 2 patients undergoing prostatectomy, in which the trocar was moved caudally. In two cases, a pelvic prolapse was repaired concomitant with other gynecological procedures. CONCLUSIONS: Pelvic surgery with the Versius is feasible without major complications; either dissection and reconstructive steps could be accomplished, provided a proper OR setup and trocar placement are pursued. Versius can be easily adopted by surgeons of different disciplines and backgrounds; a further multi-specialty implementation is presumed and long-term oncological and functional outcomes are awaited.


Assuntos
Procedimentos de Cirurgia Plástica , Neoplasias da Próstata , Procedimentos Cirúrgicos Robóticos , Masculino , Humanos , Prostatectomia/métodos , Neoplasias da Próstata/cirurgia , Cuidados Pré-Operatórios
6.
Eur Urol Focus ; 10(1): 107-114, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37634969

RESUMO

BACKGROUND: In the field of robotic surgery, there is a lack of comparative evidence on surgical and functional outcomes of different robotic platforms. OBJECTIVE: To assess the outcomes of patients receiving robot-assisted radical prostatectomy (RARP) at a high-volume robotic center with daVinci and HUGO robot-assisted surgery (RAS) surgical systems. DESIGN, SETTING, AND PARTICIPANTS: We analyzed the data of 542 patients undergoing RARP ± extended pelvic lymph node dissection at OLV hospital (Aalst, Belgium) between 2021 and 2023. All procedures were performed by six surgeons using daVinci or HUGO RAS robots; the use of one platform rather than the other did not follow any specific preference and/or indication. OUTCOME MEASUREMENTS AND STATISTICAL ANALYSIS: Multivariable analyses investigated the association between robotic system (daVinci vs HUGO RAS) and surgical outcomes after adjustment for patient- and tumor-related factors. Urinary continence recovery was defined as the use of no/one safety pad. RESULTS AND LIMITATIONS: A total of 378 (70%) and 164 (30%) patients underwent RARP with daVinci and HUGO RAS surgical systems, respectively. Despite a higher rate of palpable disease in the HUGO RAS group (34% vs 25%), baseline characteristics did not differ between the groups (all p > 0.05). After adjusting for confounders, we did not find evidence of a difference between the groups with respect to operative time (estimate: 16.71; 95% confidence interval [CI]: -6.35, 39.78; p = 0.12), estimated blood loss (estimate: 3.12; 95% CI: -67.03, 73.27; p = 0.9), and postoperative Clavien-Dindo ≥2 complications (odds ratio [OR]: 1.66; 95% CI: 0.34, 8.15; p = 0.5). On final pathology, 55 (15%) and 20 (12%) men in, respectively, the daVinci and the HUGO RAS group had positive surgical margins (PSMs; p = 0.5). On multivariable analyses, we did not find evidence of an association between a robotic system and PSMs (OR: 1.08; 95% CI: 0.56, 2.07; p = 0.8). Similarly, the odds of recovering continence did not differ between daVinci and HUGO RAS cases after both 1 mo (OR: 0.78; 95% CI: 0.45, 1.38; p = 0.4) and 3 mo (OR: 1.17; 95% CI: 0.49, 2.79; p = 0.7). CONCLUSIONS: Among patients receiving RARP with daVinci or HUGO RAS surgical platforms, we did not find differences in surgical and functional outcomes between the robots. This may be a result of a standardized surgical technique that allowed surgeons to transfer their skills between robotic systems. Awaiting future investigations with longer follow-up, these results have important implications for patients, surgeons, and health care policymakers. PATIENT SUMMARY: We compared surgical and functional outcomes of patients receiving robot-assisted radical prostatectomy with daVinci versus HUGO robot-assisted surgery (RAS) robots. The two platforms were able to achieve similar outcomes, suggesting that the introduction of HUGO RAS is safe and allows for optimal outcomes after radical prostatectomy.


Assuntos
Procedimentos Cirúrgicos Robóticos , Robótica , Masculino , Humanos , Feminino , Procedimentos Cirúrgicos Robóticos/métodos , Próstata , Prostatectomia/métodos , Excisão de Linfonodo
7.
World J Urol ; 41(12): 3737-3744, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37917223

RESUMO

PURPOSE: In the emerging field of robotics, only few studies investigated the transition between different robotic platforms in terms of surgical outcomes. We aimed at assessing surgical outcomes of patients receiving robot-assisted radical prostatectomy (RARP) and robot-assisted partial nephrectomy (RAPN) at a high-volume robotic center during the transition from Si to Xi Da Vinci surgical systems. METHODS: We analyzed data of 1884 patients undergoing RARP (n = 1437, 76%) and RAPN (n = 447, 24%) at OLV hospital (Aalst, Belgium) between 2011 and 2021. For both procedures, we assessed operative time, estimated blood loss, length of stay, and positive surgical margins. For RARP, we investigated length of catheterization and PSA persistence after surgery, whereas warm ischemia time, clampless surgery, and acute kidney injury (AKI) were assessed for RAPN. Multivariable analyses (MVA) investigated the association between robotic platform (Si vs. Xi) and surgical outcomes after adjustment for patient- and tumor-related factors. RESULTS: A total of 975 (68%) and 462 (32%) patients underwent RARP performed with the Si vs. Xi surgical system, respectively. Baseline characteristics did not differ between the groups. On MVA, we did not find evidence of a difference between the groups with respect to operative time (estimate: 1.07) or estimated blood loss (estimate: 32.39; both p > 0.05). Median (interquartile range [IQR]) length of stay was 6 (3, 6) and 4 (3, 5) days in the Si vs. Xi group, respectively (p < 0.0001). On MVA, men treated with the Xi vs. Si robot had lower odds of PSM (Odds ratio [OR]: 0.58; p = 0.014). A total of 184 (41%) and 263 (59%) patients received RAPN with the Si and Xi robotic system, respectively. Baseline characteristics, including demographics, functional data, and tumor-related features did not differ between the groups. On MVA, operative time was longer in the Xi vs. Si group (estimate: 30.54; p = 0.006). Patients treated with the Xi vs. Si system had higher probability of undergoing a clampless procedure (OR: 2.56; p = 0.001), whereas the risk of AKI did not differ between the groups (OR: 1.25; p = 0.4). On MVA, patients operated with the Xi robot had shorter length of stay as compared to the Si group (estimate: - 0.86; p = 0.003), whereas we did not find evidence of an association between robotic system and PSM (OR: 1.55; p = 0.3). CONCLUSION: We found that the Xi robot allowed for improvements in peri-operative outcomes as compared to the Si platform, with lower rate of positive margins for RARP and higher rate of off-clamp procedures for RAPN. Hospital stay was also shorter for patients operated with the Xi vs. Si robot, especially after robot-assisted partial nephrectomy. Awaiting future investigations-in particular, cost analyses-these results have important implications for patients, surgeons, and healthcare policymakers.


Assuntos
Injúria Renal Aguda , Neoplasias , Procedimentos Cirúrgicos Robóticos , Robótica , Masculino , Humanos , Resultado do Tratamento , Procedimentos Cirúrgicos Robóticos/métodos
8.
Asian J Urol ; 10(4): 475-481, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38024438

RESUMO

Objective: In the last years, robotic surgery was introduced in several different settings with good perioperative results. However, its role in the management of adrenal masses is still debated. In order to provide a contribution to this field, we described our step-by-step technique for robotic adrenalectomy (RA) and related modifications according to the type of adrenal mass treated. Methods: We retrospectively analyzed 27 consecutive patients who underwent RA at Onze-Lieve-Vrouw hospital (Aalst, Belgium) between January 2009 and October 2022. Demographic, intra- and post-operative, and pathological data were retrieved from our prospectively maintained institutional database. Continuous variables are summarized as median and interquartile range (IQR). Categorical variables are reported as frequencies (percentages). Results: Twenty-seven patients underwent RA were included in the study. Median age, body mass index, and Charlson's comorbidity index were 61 (IQR: 49-71) years, 26 (IQR: 24-29) kg/m2, and 2 (IQR: 0-3), respectively, and 16 (59.3%) patients were male. Median tumor size at computed tomography scan was 6.0 (IQR: 3.5-8.0) cm. Median operative time and blood loss were 105 (IQR: 82-120) min and 175 (IQR: 94-250) mL, respectively. No intraoperative complications were recorded. Overall postoperative complications rate was 11.1%, with a postoperative transfusion rate of 3.7%. A total of 10 (37.0%) patients harbored malignant adrenal masses. Among them, 3 (11.1%) had adrenocortical carcinoma, 6 (22.2%) secondary metastasis, and 1 (3.7%) malignant pheochromocytoma on final pathological exam. Only 1 (10.0%) patient had positive surgical margins. Conclusion: We described our step-by-step technique for RA, which can be safely performed even in case of high challenging settings as malignant tumors, pheochromocytoma, and large masses. The standardization of perioperative protocol should be encouraged to maximize the outcomes of this complex surgical procedure.

9.
J Pers Med ; 13(10)2023 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-37888045

RESUMO

Despite the arising interest in three-dimensional (3D) reconstruction models from 2D imaging, their diffusion and perception among urologists have been scarcely explored. The aim of the study is to report the results of an international survey investigating the use of such tools among urologists of different backgrounds and origins. Beyond demographics, the survey explored the degree to which 3D models are perceived to improve surgical outcomes, the procedures mostly making use of them, the settings in which those tools are mostly applied, the surgical steps benefiting from 3D reconstructions and future perspectives of improvement. One hundred responders fully completed the survey. All levels of expertise were allowed; more than half (53%) were first surgeons, and 59% had already completed their training. Their main application was partial nephrectomy (85%), followed by radical nephrectomy and radical prostatectomy. Three-dimensional models are mostly used for preoperative planning (75%), intraoperative consultation and tailoring. More than half recognized that 3D models may highly improve surgical outcomes. Despite their recognized usefulness, 77% of responders use 3D models in less than 25% of their major operations due to costs or the extra time taken to perform the reconstruction. Technical improvements and a higher availability of the 3D models will further increase their role in surgical and clinical daily practice.

10.
J Robot Surg ; 17(6): 3039-3043, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37775674

RESUMO

The Hugo RAS and Versius are new robotic systems with a multimodular configuration, requiring a dedicated positioning of units, arms and trocars. While promising flexibility and multiquadrant opportunities-with an enhanced range of motion-the presence of multiple units around the patient should be effectively managed by the assistant and requires a new background of tasks. The article represents a practical guide while providing an overview on assistants' perspectives.


Assuntos
Pelve , Procedimentos Cirúrgicos Robóticos , Humanos , Procedimentos Cirúrgicos Robóticos/métodos , Pelve/cirurgia
11.
Int. braz. j. urol ; 49(4): 521-522, July-Aug. 2023.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1506402

RESUMO

ABSTRACT Introduction: Bladder neck dissection is one of the most delicate surgical steps of robotic-assisted radical prostatectomy (RARP) [1, 2], and it may affect surgical margins rate and functional outcomes [3, 4]. Given the relationship between outcomes and surgical experience [5-7], it is crucial to implement a step-by-step approach for each surgical step of the procedure, especially in the most challenging part of the intervention. In this video compilation, we described the techniques for bladder neck dissection utilized at OLV Hospital (Aalst, Belgium). Surgical Technique: We illustrated five different techniques for bladder neck dissection during RARP. The anterior technique tackles the bladder neck from above until the urethral catheter is visualized, and then the dissection is completed posteriorly. The lateral and postero-lateral approaches involve the identification of a weakness point at the prostate-vesical junction and aim to develop the posterior plane - virtually until the seminal vesicles - prior to the opening of the urethra anteriorly. Finally, we described our techniques for bladder neck dissection in more challenging cases such as in patients with bulky middle lobes and prior surgery for benign prostatic hyperplasia. All approaches follow anatomic landmarks to minimize positive surgical margins and aim to preserve the bladder neck in order to promote optimal functional recovery. All procedures were performed with DaVinci robotic platforms using a 3-instruments configuration (scissors, fenestrated bipolar, and needle driver). As standard protocol at our Institution, urinary catheter was removed on postoperative day two [8]. Conclusions: Five different approaches for bladder neck dissection during RARP were described in this video compilation. We believe that the technical details provided here might be of help for clinicians who are starting their practice with this surgical intervention.

12.
Eur Urol Open Sci ; 53: 83-89, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37441345

RESUMO

Background: Robot-assisted surgery ensures minimal invasiveness; since the expiry of the Da Vinci patent, new robotic systems have entered the market. Recently, the Hugo RAS received CE approval for several surgical procedures. However, more is needed to know about skill acquisition at the new simulator. Objective: This study aims to analyse the factors impacting basic surgical skills at the Hugo RAS simulator. Design setting and participants: We present a cross-sectional study involving 71 participants of different backgrounds invited to a hands-on session with the Hugo RAS simulator voluntarily. All of them had no prior expertise with the system. Participants were recruited among medical/nurse students, residents, and laparoscopic and robotic surgeons. Intervention: All participants underwent a hands-on "pick and place" exercise at the Hugo RAS simulator; the metrics of a second-round pick and place exercise were recorded. Outcome measurements and statistical analysis: Metrics were analysed with regard to the following variables: demographics, videogame use, and prior surgical experience (no surgical expertise, experience with laparoscopy, and experience with robotic console). Results and limitations: All participants completed the test. Of them, 77.5% were naïve to surgery, 8.5% had prior laparoscopic expertise, and 14.1% had prior robotic console experience. The time to complete the pick and place exercise was significantly lower (p < 0.001) among prior robotic surgeons (38 s, interquartile range [IQR] 34-45) compared with both naïve participants (61 s, IQR 53-71) and laparoscopists (93 s, IQR 53-162). The overall score of the exercise decreased with age (p = 0.046); however, the overall scores were significantly and steadily higher among surgeons experienced in robotic consoles across all age groups (p = 0.006). Neither gender (p = 0.7) nor videogame use (p = 0.9) correlated significantly with the metrics. Conclusions: This is the first study analysing factors impacting basic skill acquisition at a new robotic simulator. Experience with robotic consoles may represent a major factor, raising the hypothesis of the transferability of basic robotic skills across different robotic systems. Further studies are required to explore this issue. Patient summary: In the present study, we analysed which characteristics may affect the basic surgical skills at a novel robotic platform.

14.
J Robot Surg ; 17(5): 2247-2251, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37294418

RESUMO

Robotic assisted radical cystectomy (RARC) is a standard option for the treatment of bladder cancer. Currently, novel platforms are entering the market and the Hugo RAS (Medtronic, Minneapolis, MN, USA) is a new system consisting of an open console with 3D-HD screen and a multi-modular fashion. Even if several series are already available for radical prostatectomy, to now a full description of RARC performed with Hugo RAS is still lacking. We report the first case of RARC with intracorporeal neobladder performed with the Hugo RAS-and another case of RARC with ureterostomy. Both patients were affected by MIBC. Case 1 was a 61-year-old patient without comorbidities (CCI 4), in which a Bordeaux ileal neobladder was scheduled after previous NAC. The second was the case of a 70-year-old one with CCI 7 and BMI 35; in this case, a ureterostomy was planned. Details of the robotic system: one 11 mm endoscope port was placed on the midline 2 cm above the umbilicus. Another two 8 mm robotic ports were symmetrically placed under vision on a transversal line-located 1 cm below the umbilicus. A third robotic port was positioned on the left side in a W configuration. All ports were located at least 9 cm between each other. Finally, two assistant ports were positioned in the right abdominal site. All arm-carts were parked 45-60 cm from the operative bed, before the docking process begins. Three arm-carts were parked on the left side, the assistant and the scrub nurse worked on the right side, while the energy tower stayed at the foot of the bed, according to the previous description of Hugo RAS robotic radical prostatectomy. The endoscope arm-cart is docked first, then the adjacent left carts are docked; finally, the surgeon's right-hand cart is docked from the right side of the bed. The docking angles and tilt we applied were: endoscope: 175°; minus 45°; surgeon left hand 140°; minus 30°; surgeon right hand 225°; minus 30°; fourth arm 125°; plus 15°. The instruments we used were those fitting our conventional four-instrument setup for RARC: monopolar shears, Maryland forceps, needle driver and Cadiere as the fourth arm. The procedures were completed without technical errors or technological failures-requiring a change in surgical strategy. Docking time was approximately 35 min; console time up to urethral dissection was 150 and 140 min in Case 1 and 2. The time for pelvic nodal dissection was approximately 37 min for both. The multi-modularity fashion of the Hugo RAS allowed an easy management of the bowel in Case 1; the absence of robotic staplers required the use of the laparoscopic ones, managed by an adjunctive assistant with room within the cart. In conclusion, RARC with the Hugo RAS is a feasible procedure able to reproduce all surgical steps without critical errors or complications requiring a change in surgical planning. Urinary diversion with intracorporeal reconstruction is feasible as well, with adequate preliminary outcomes.


Assuntos
Procedimentos Cirúrgicos Robóticos , Robótica , Neoplasias da Bexiga Urinária , Derivação Urinária , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Cistectomia/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Bexiga Urinária/cirurgia , Derivação Urinária/métodos , Neoplasias da Bexiga Urinária/cirurgia , Resultado do Tratamento
15.
Int Braz J Urol ; 49(4): 521-522, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37267619

RESUMO

INTRODUCTION: Bladder neck dissection is one of the most delicate surgical steps of robotic-assisted radical prostatectomy (RARP) [1, 2], and it may affect surgical margins rate and functional outcomes [3, 4]. Given the relationship between outcomes and surgical experience [5-7], it is crucial to implement a step-by-step approach for each surgical step of the procedure, especially in the most challenging part of the intervention. In this video compilation, we described the techniques for bladder neck dissection utilized at OLV Hospital (Aalst, Belgium). SURGICAL TECHNIQUE: We illustrated five different techniques for bladder neck dissection during RARP. The anterior technique tackles the bladder neck from above until the urethral catheter is visualized, and then the dissection is completed posteriorly. The lateral and postero-lateral approaches involve the identification of a weakness point at the prostate-vesical junction and aim to develop the posterior plane - virtually until the seminal vesicles - prior to the opening of the urethra anteriorly. Finally, we described our techniques for bladder neck dissection in more challenging cases such as in patients with bulky middle lobes and prior surgery for benign prostatic hyperplasia. All approaches follow anatomic landmarks to minimize positive surgical margins and aim to preserve the bladder neck in order to promote optimal functional recovery. All procedures were performed with DaVinci robotic platforms using a 3-instruments configuration (scissors, fenestrated bipolar, and needle driver). As standard protocol at our Institution, urinary catheter was removed on postoperative day two [8]. CONCLUSIONS: Five different approaches for bladder neck dissection during RARP were described in this video compilation. We believe that the technical details provided here might be of help for clinicians who are starting their practice with this surgical intervention.


Assuntos
Neoplasias da Próstata , Procedimentos Cirúrgicos Robóticos , Robótica , Masculino , Humanos , Bexiga Urinária/cirurgia , Procedimentos Cirúrgicos Robóticos/métodos , Robótica/métodos , Esvaziamento Cervical , Próstata , Glândulas Seminais , Prostatectomia/métodos , Neoplasias da Próstata/cirurgia
16.
Urologia ; 90(1): 146-150, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37014088

RESUMO

INTRODUCTION: Ex-vivo FCM is a novel digital optical technique that provides images of fresh tissues in a real-time fashion with magnification to subcellular details of a flattened unprocessed sample. Digital images are hematoxylin-eosin-like and can be shared and interpreted remotely. In urology, FCM has been successfully applied for prostate tissue interpretation, either during biopsy and radical prostatectomy. Possible applications of FCM may reflect those of frozen section analysis and can be extended to all fields in which the intra-operative microscopical control is advisable. MATERIALS AND METHODS: This is an investigative prospective case series that aims to explore FCM feasibility in novel surgical settings and provide a depiction of FCM digital images in those fields. The definite purpose is to check the accuracy of surgical specimen during the following interventions: (a) trans-urethral resection of bladder tumors, to confirm the presence of muscular layer; (b) biopsy of a retroperitoneal mass, to check for the location and quality of cores; (c) training in robotic radical prostatectomy, to control surgical margins after a nerve sparing performed by a trainee. To this aim, we collected FCM images during seven surgical procedures. FCM findings were compared to those from the final histopathological analysis and the agreement was assessed. RESULTS: In all cases, FCM digital images were obtained in the OR. FCM was able to confirm the presence of muscular layer in TURB specimen, the presence of lymphomatous tissue, surgical margins at prostate specimen. FCM intra-operative interpretation was consistent with final histopathology in all cases. CONCLUSIONS: Ex vivo FCM may represent a novel approach to control the quality of specimens, likely to tailor surgical strategy in a real-time fashion. Moreover, digitalization represents a step toward the implementation of telepathology in clinical practice.


Assuntos
Margens de Excisão , Neoplasias da Próstata , Masculino , Humanos , Microscopia , Próstata/cirurgia , Próstata/patologia , Biópsia , Prostatectomia/métodos , Neoplasias da Próstata/cirurgia , Neoplasias da Próstata/patologia
18.
Eur Urol ; 84(1): 86-91, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36941148

RESUMO

Several barriers prevent the integration and adoption of augmented reality (AR) in robotic renal surgery despite the increased availability of virtual three-dimensional (3D) models. Apart from correct model alignment and deformation, not all instruments are clearly visible in AR. Superimposition of a 3D model on top of the surgical stream, including the instruments, can result in a potentially hazardous surgical situation. We demonstrate real-time instrument detection during AR-guided robot-assisted partial nephrectomy and show the generalization of our algorithm to AR-guided robot-assisted kidney transplantation. We developed an algorithm using deep learning networks to detect all nonorganic items. This algorithm learned to extract this information for 65 927 manually labeled instruments on 15 100 frames. Our setup, which runs on a standalone laptop, was deployed in three different hospitals and used by four different surgeons. Instrument detection is a simple and feasible way to enhance the safety of AR-guided surgery. Future investigations should strive to optimize efficient video processing to minimize the 0.5-s delay currently experienced. General AR applications also need further optimization, including detection and tracking of organ deformation, for full clinical implementation.


Assuntos
Realidade Aumentada , Aprendizado Profundo , Procedimentos Cirúrgicos Robóticos , Robótica , Cirurgia Assistida por Computador , Humanos , Procedimentos Cirúrgicos Robóticos/métodos , Cirurgia Assistida por Computador/métodos , Imageamento Tridimensional/métodos
19.
Diagnostics (Basel) ; 13(4)2023 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-36832202

RESUMO

Radical cystectomy represents one of the most challenging surgical procedures, exhibiting a high morbidity rate. The transition to minimally invasive surgery in the field has been steep, due to either the technical complexity and prior concerns of atypical recurrences and/or peritoneal spread. More recently, a larger series of RCTs has proven the oncological safety of robot-assisted radical cystectomy (RARC). Beyond survival outcomes, the comparison between RARC and open surgery in terms of peri-operative morbidity is still ongoing. We present a single-center experience of RARC with intracorporeal urinary diversion. Overall, 50% of patients had an intracorporeal neobladder reconstruction. The series confirms a low rate of complications (Clavien Dindo ≥ IIIa 7.5%) and wound infections (2.5%) and the absence of thromboembolic events. No atypical recurrences were found. To discuss these outcomes, we reviewed the literature related to RARC including level-1 evidence. PubMed and Web of Science searches were performed using the medical subject terms "robotic radical cystectomy" and "randomized controlled trial (RCT)". Six unique RCTs comparing robot and open surgery were found. Two clinical trials dealt with RARC with an intracorporeal reconstruction of UD. Pertinent clinical outcomes are summarized and discussed. In conclusion, RARC is a complex but feasible procedure. The transition from extracorporeal urinary diversion (UD) to a complete intracorporeal reconstruction could be the key to improving peri-operative outcomes and reducing the whole morbidity of the procedure.

20.
Minerva Urol Nephrol ; 75(2): 223-230, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36847584

RESUMO

BACKGROUND: Patients with multiple ipsilateral renal masses have an augmented risk of metachronous contralateral lesions and are likely to undergo repeated surgeries. We report our experience with the technologies currently available and the surgical techniques to preserve healthy parenchyma while guaranteeing oncological radicality during robot-assisted partial nephrectomy (RAPN). METHODS: The data were collected at three tertiary-care centers, where 61 patients with multiple ipsilateral renal masses were treated with RAPN between 2012 and 2021. RAPN was performed with da Vinci Si or Xi surgical system using TilePro (Life360; San Francisco, CA, USA), indocyanine green fluorescence and intraoperative ultrasound. Three-dimensional reconstructions were built in some cases preoperatively. Different techniques were employed for hilum management. The primary endpoint is to report intra- and postoperative complications. Secondary endpoints were the estimated blood loss (EBL), warm ischemia time (WIT) and positive surgical margins (PSM) rate. RESULTS: Median preoperative size of the largest mass was 37.5 mm (24-51) with a median PADUA and R.E.N.A.L. score of 8 (7-9) and 7 (6-9). One hundred forty-two tumors were excised, with a mean number of 2.32. The median WIT was 17 (12-24) minutes, and the median EBL was 200 (100-400) mL. Intraoperative ultrasound was employed in 40 (67.8%) patients. The rate of early unclamping, selective clamping and zero-ischemia were respectively 13 (21.3%), 6 (9.8%) and 13 (21.3%). ICG fluorescence was employed in 21 (34.42%) patients and three-dimensional reconstructions were built in 7 (11.47%) patients. Three (4.8%) intraoperative complications occurred, all classified as grade-1 according to EAUiaiC. Postoperative complications were reported in 14 (22.9%) cases with 2 Clavien-Dindo grade >2 complications. Four (6.56%) patients had PSM. Mean period of follow-up was 21 months. CONCLUSIONS: In experienced hands, with the employment of the currently available technologies and surgical techniques, RAPN can guarantee optimal outcomes in patients with multiple ipsilateral renal masses.


Assuntos
Neoplasias Renais , Robótica , Humanos , Robótica/métodos , Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/cirurgia , Neoplasias Renais/patologia , Resultado do Tratamento , Nefrectomia/métodos , Complicações Pós-Operatórias/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA