Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Minerva Cardioangiol ; 68(5): 368-372, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32336080

RESUMO

BACKGROUND: Infection due to severe acute respiratory syndrome-coronavirus-2 (SARS-CoV-2), i.e. coronavirus-associated disease 2019 (COVID-2019), may occasionally lead to acute respiratory distress syndrome (ARDS), requiring in the most severe cases extracorporeal membrane oxygenation (ECMO). Yet, limited data, if any, are currently available on the role of ECMO in critically ill patients with COVID-19. We aimed at providing a snapshot analysis of ECMO for COVID-19 in Europe. METHODS: Freely available data on ECMO in COVID-19 patients reported by the European Extracorporeal Life Support Organization (EuroELSO) were extracted and analyzed after conversion into long format. The primary outcome was the incidence of death during ECMO. Bootstrapping and logistic regression were used for inferential estimates. RESULTS: Details from a total of 333 patients treated in 90 institutions spanning 17 countries were obtained, with 22% women and mean age of 52 years. Death rate was 17.1% (95% confidence interval: 13.1% to 21.1%), even if significant between-center differences were found, with some institutions reporting 100% case fatality. Exploratory inferential analysis showed no nominally statistically significant association between death and gender (P=0.788), but a significant association was found with age, mainly due to increased case fatality in subjects >60 years (odds ratio: 4.80 [95% confidence interval 1.64 to 14.04], P=0.004). CONCLUSIONS: ECMO may play an important role in critically ill patients with COVID-19 refractory to less invasive treatments. The increased risk of early death in older patients may be used to prioritize ECMO indication in resource-conscious settings, if confirmed externally.


Assuntos
Infecções por Coronavirus/terapia , Estado Terminal/terapia , Oxigenação por Membrana Extracorpórea/métodos , Pneumonia Viral/terapia , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , COVID-19 , Infecções por Coronavirus/complicações , Infecções por Coronavirus/mortalidade , Europa (Continente)/epidemiologia , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Pandemias , Pneumonia Viral/complicações , Pneumonia Viral/mortalidade , Síndrome do Desconforto Respiratório/complicações , Síndrome do Desconforto Respiratório/terapia , Fatores Sexuais
2.
Interact Cardiovasc Thorac Surg ; 29(5): 685-692, 2019 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-31302701

RESUMO

OBJECTIVES: Reports ranged from mixed to marginal tubing wear and spallation effects as a complication of roller pumps in cardiopulmonary bypass (CPB). Because the rollers constantly compress part of the tubing, we sought to determine whether circuit materials behave differently under a 3-h simulation of CPB. METHODS: Two different tubing materials (silicone and Tygon) were tested with a customized experimental circuit, designed to allow in vitro simulation of CPB with priming volumes, pressures, revolutions per minute and temperatures equivalent to the clinical scenario. Samples were analysed with optical and field-emission scanning electron microscopy. We collected 200-ml fluid samples at 4 different times: before starting the CPB (T0), when the predicted revolutions per minute corresponded to about 2 min of CPB (T1), at 90 min (T2) and at 180 min (T3). At the end of CPB, we harvested 2 samples of tubing. Lastly, optical investigations and field-emission scanning electron microscopy observations were used for qualitative and quantitative analysis of circulating fragments. RESULTS: T2 and T3 fluid samples showed more particles than T1 samples. Significant differences in terms of particle numbers were detected: silicone tubing released more fragments per millilitre than Tygon tubing, with both materials releasing particles from 5 to 500 µm. Silicone tubing was associated with a time-dependent increase in small particles released (P = 0.04), whereas this did not apply to large particles or to Tygon tubing. Yet, bootstrap estimates suggested that silicone tubing was associated with the release of more small particles whereas Tygon tubing released more large particles (both P < 0.01). Unlike silicone, Tygon samples taken from the portion of the circuit not subjected to the action of the roller pump did not show any erosion on their surfaces. Samples of both materials taken from the portion subjected to the compression of the roller pump showed signs of significant deterioration. CONCLUSIONS: Silicone showed a worse spallation performance than Tygon, thus appearing less safe for more complex surgery of prolonged duration or for patients with a prior cerebral ischaemic event. Additional risk and cost-effectiveness comparisons to determine the potential benefits of one type of tubing material over the other are warranted to further expand our findings.


Assuntos
Simulação por Computador , Circulação Extracorpórea/instrumentação , Teste de Materiais/métodos , Cloreto de Polivinila , Silicones , Desenho de Equipamento , Humanos , Microscopia Eletrônica de Varredura
3.
Oxid Med Cell Longev ; 2014: 242180, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24829620

RESUMO

Ex vivo lung perfusion (EVLP) allows perfusion and reconditioning of retrieved lungs for organ transplantation. The Steen solution is specifically designed for this procedure but the mechanism through which it elicits its activity is still to be fully clarified. We speculated that Steen solution may encompass antioxidant properties allowing a reestablishment of pulmonary tissue homeostasis. Blood samples from 10 healthy volunteers were recruited. Platelets and white cells were incubated with Steen solution or buffer solution as control and stimulated with suitable agonists. Reactive oxidant species (ROS), soluble NOX2 (sNOX2-derived peptide), a marker of NADPH oxidase activation, p47(phox) translocation to cell membrane and isoprostanes production, as marker of oxidative stress, and nitric oxide (NO), a powerful vasodilator and antioxidant molecule, were measured upon cell stimulation. The Steen solution significantly inhibited p47(phox) translocation and NOX2 activation in platelets and white cells. Consistent with this finding was the reduction of oxidative stress as documented by a significantly lowered formation of ROS and isoprostanes by both platelets and white cells. Finally, cell incubation with Steen solution resulted in enhanced generation of NO. Herewith, we provide the first evidence that Steen solution possesses antioxidant properties via downregulation of NADPH oxidase activity and enhanced production of NO.


Assuntos
Antioxidantes/farmacologia , Plaquetas/efeitos dos fármacos , Dextranos/farmacologia , Regulação para Baixo/efeitos dos fármacos , Soluções Isotônicas/farmacologia , Leucócitos/efeitos dos fármacos , Glicoproteínas de Membrana/metabolismo , NADPH Oxidases/metabolismo , Albumina Sérica/farmacologia , Acetofenonas/farmacologia , Adulto , Plaquetas/metabolismo , Dinoprosta/análogos & derivados , Dinoprosta/metabolismo , Feminino , Humanos , Isoprostanos/metabolismo , Leucócitos/metabolismo , Masculino , NADPH Oxidase 2 , Óxido Nítrico/metabolismo , Espécies Reativas de Oxigênio/metabolismo
4.
J Cardiothorac Surg ; 7: 20, 2012 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-22405024

RESUMO

Obese patients undergoing cardiac surgery have been shown to have a high risk of developing postoperative complications, specifically: increased length of hospital stay, readmission to intensive care unit, acute renal failure, deep sternal wound infections and new onset of atrial fibrillation.A custom-made circuit was created to allow the use of Mini Extra Corporeal Circulation (MECC) but permitting the switch to a closed siphon drainage system in the case of difficulties.To limit artificial surface contact a small oxygenating device (Admiral, Eurosets) was employed in spite of the patients size. This adapted circuit permits a feasible and safer approach to using MECC. This report suggests that smaller oxygenators could be integrated into clinical practice in an adult MECC configuration, even for more obese patients, limiting artificial surface contact.


Assuntos
Estenose da Valva Aórtica/cirurgia , Ponte Cardiopulmonar/métodos , Implante de Prótese de Valva Cardíaca/métodos , Obesidade/complicações , Idoso , Estenose da Valva Aórtica/complicações , Ponte Cardiopulmonar/instrumentação , Humanos , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA