Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J AOAC Int ; 100(2): 537-547, 2017 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-28118134

RESUMO

The AccuPoint Advanced ATP Hygeine Monitoring System was validated by an AOAC International Performance Tested MethodSM on the detection of ATP from stainless steel surfaces. Neogen Corp.'s system is a lightweight, hand-held diagnostic tool used to validate and verify a hygiene program's effectiveness by detecting organic residues remaining on surfaces and in liquids after cleaning. The system is composed of three primary components: an electronic luminometer, fully self-contained single-use samplers, and software. The system is designed to detect adenosine triphosphate (ATP) at set thresholds and to report the measurement in relative light units (RLU). These thresholds are established by a facility to reflect effective cleaning practices. The instrument compares the measured level of ATP with the established threshold and reports the results as pass, marginal, or fail. A linear dose-response in RLU was observed with pure analyte. In the matrix and microbial studies, detection levels varied depending on the matrix and microorganism tested. Independent laboratory trials confirmed pure analyte and matrix observations. Specificity testing of similar, yet different, compounds resulted in 0 RLU for all except 2'-deoxyadenosine 5'-triphosphate sodium salt, which showed markedly reduced reactivity when compared with ATP. Also, interference by these compounds was negligible. When disinfectant residues were evaluated for their effect on the test, cleaners increased RLU output to varying degrees. Stability testing showed consistent results between three independently manufactured lots and stable results through the 9 month shelf-life. Additionally, when three readers were compared using electronic light-emitting diodes as the light source, instrument variability was low (<3%). Robustness testing results provided evidence that temperature affects test performance more than shaking time, and sampler performance improves as the temperature increases to room temperature. These results provided evidence that the AccuPoint Advanced ATP Hygiene Monitoring System produces consistent and reliable data for the evaluation of sanitation program effectiveness on stainless steel surfaces in food processing and food service facilities.


Assuntos
Trifosfato de Adenosina/análise , Aço Inoxidável/análise , Compostos de Benzalcônio/química , Ácidos Decanoicos/química , Ácidos Graxos/química , Higiene , Limite de Detecção , Luciferases/química , Medições Luminescentes , Pseudomonas aeruginosa/isolamento & purificação , Saccharomyces cerevisiae/isolamento & purificação , Saneamento , Hipoclorito de Sódio/química , Staphylococcus aureus/isolamento & purificação
2.
J AOAC Int ; 97(4): 1084-91, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25145142

RESUMO

A study was carried out to determine the efficacy of the Soleris Direct Yeast and Mold (DYM) automated growth-based method for semiquantitative detection of yeast and mold in a variety of food products. A probability of detection (POD) statistical model was used to compare Soleris results at multiple test thresholds (dilutions) with plate counts determined using the U.S. Food and Drug Administration Bacteriological Analytical Manual, Chapter 18, dilution plating procedure. Fourteen naturally contaminated food products were tested, with Soleris testing performed at three or more threshold levels for each food. Using the POD model, the majority of Soleris test results were in statistical agreement with the reference plating procedures. The exceptions included a single threshold level in yogurt, black pepper, dried fruit, and dry pet food, and two levels in nonfat dry milk and saw palmetto powder. In all but one of these instances, the exception being pet food, the statistical disagreement was due to Soleris estimating a higher level of contamination than the reference method. Results of ruggedness testing showed that the Soleris method produced accurate results even when significant variances in a critical operating parameter, incubation temperature, were introduced. Results of the internal and independent laboratory validation studies showed that the Soleris DYM method can be used as an accurate alternative to conventional dilution plating procedures for evaluation of yeast and mold counts at threshold levels, while saving as much as 72 h in analysis time.


Assuntos
Análise de Alimentos , Contaminação de Alimentos/análise , Fungos/isolamento & purificação , Saccharomyces cerevisiae/isolamento & purificação
3.
J AOAC Int ; 96(2): 399-403, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23767366

RESUMO

A study was conducted to determine the efficacy of the Soleris Non-fermenting-Total Viable Count (NF-TVC) automated growth-based method for semiquantitative detection of mesophilic, aerobic microorganisms in a variety of food products. A probability of detection (POD) statistical model was used to compare Soleris results at multiple test thresholds (dilutions) with aerobic plate counts determined using reference dilution plating procedures. Nine naturally contaminated food products were tested, with Soleris testing performed at three or four threshold levels for each food. Using the POD model, all Soleris test results were in statistical agreement with the reference plating procedures with the exception of a single threshold level in two trials with black pepper, and a single threshold level in the independent laboratory trial with cheesecake. Results of ruggedness testing showed that the Soleris method produced accurate results even when minor variances in operating parameters, including sample volume and incubation temperature, were introduced. Results of the internal and independent laboratory validation studies showed that the Soleris NF-TVC method can be used as an accurate alternative to conventional dilution plating procedures for evaluation of microbial counts at threshold levels, while saving 24 h or more in analysis time.


Assuntos
Bactérias/isolamento & purificação , Técnicas Bacteriológicas/métodos , Microbiologia de Alimentos/métodos , Microbiologia de Alimentos/normas , Animais , Automação , Bactérias/classificação , Técnicas Bacteriológicas/normas , Contagem de Colônia Microbiana , Análise de Alimentos/métodos , Reprodutibilidade dos Testes
4.
Bioorg Med Chem Lett ; 23(11): 3438-42, 2013 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-23582272

RESUMO

We identified potent, selective PDE2 inhibitors by optimizing residual PDE2 activity in a series of PDE4 inhibitors, while simultaneously minimizing PDE4 activity. These newly designed PDE2 inhibitors bind to the PDE2 enzyme in a cGMP-like mode in contrast to the cAMP-like binding mode found in PDE4. Structure activity relationship studies coupled with an inhibitor bound crystal structure in the active site of the catalytic domain of PDE2 identified structural features required to minimize PDE4 inhibition while simultaneously maximizing PDE2 inhibition.


Assuntos
Azirinas/química , Nucleotídeo Cíclico Fosfodiesterase do Tipo 2/antagonistas & inibidores , Nucleotídeo Cíclico Fosfodiesterase do Tipo 4/química , Di-Hidropiridinas/química , Inibidores da Fosfodiesterase 4/química , Inibidores de Fosfodiesterase/química , Animais , Azirinas/metabolismo , Azirinas/uso terapêutico , Sítios de Ligação , Domínio Catalítico , Cristalografia por Raios X , Nucleotídeo Cíclico Fosfodiesterase do Tipo 2/metabolismo , Nucleotídeo Cíclico Fosfodiesterase do Tipo 4/metabolismo , Di-Hidropiridinas/metabolismo , Di-Hidropiridinas/uso terapêutico , Modelos Animais de Doenças , Avaliação Pré-Clínica de Medicamentos , Osteoartrite/tratamento farmacológico , Inibidores de Fosfodiesterase/metabolismo , Inibidores de Fosfodiesterase/uso terapêutico , Ligação Proteica , Relação Estrutura-Atividade
5.
Bioorg Med Chem Lett ; 23(11): 3443-7, 2013 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-23597790

RESUMO

Selective phosphodiesterase 2 (PDE2) inhibitors are shown to have efficacy in a rat model of osteoarthritis (OA) pain. We identified potent, selective PDE2 inhibitors by optimizing residual PDE2 activity in a series of phosphodiesterase 4 (PDE4) inhibitors, while minimizing PDE4 inhibitory activity. These newly designed PDE2 inhibitors bind to the PDE2 enzyme in a cGMP-like binding mode orthogonal to the cAMP-like binding mode found in PDE4. Extensive structure activity relationship studies ultimately led to identification of pyrazolodiazepinone, 22, which was >1000-fold selective for PDE2 over recombinant, full length PDEs 1B, 3A, 3B, 4A, 4B, 4C, 7A, 7B, 8A, 8B, 9, 10 and 11. Compound 22 also retained excellent PDE2 selectivity (241-fold to 419-fold) over the remaining recombinant, full length PDEs, 1A, 4D, 5, and 6. Compound 22 exhibited good pharmacokinetic properties and excellent oral bioavailability (F=78%, rat). In an in vivo rat model of OA pain, compound 22 had significant analgesic activity 1 and 3h after a single, 10 mg/kg, subcutaneous dose.


Assuntos
Azepinas/química , Azirinas/química , Nucleotídeo Cíclico Fosfodiesterase do Tipo 2/antagonistas & inibidores , Di-Hidropiridinas/química , Inibidores de Fosfodiesterase/química , Pirazóis/química , Analgésicos/química , Analgésicos/farmacocinética , Analgésicos/uso terapêutico , Animais , Azepinas/farmacocinética , Azepinas/uso terapêutico , Azirinas/farmacocinética , Azirinas/uso terapêutico , Sítios de Ligação , Domínio Catalítico , Cristalografia por Raios X , Nucleotídeo Cíclico Fosfodiesterase do Tipo 2/metabolismo , Di-Hidropiridinas/farmacocinética , Di-Hidropiridinas/uso terapêutico , Modelos Animais de Doenças , Avaliação Pré-Clínica de Medicamentos , Meia-Vida , Osteoartrite/tratamento farmacológico , Inibidores da Fosfodiesterase 4/química , Inibidores de Fosfodiesterase/farmacocinética , Inibidores de Fosfodiesterase/uso terapêutico , Ligação Proteica , Pirazóis/farmacocinética , Pirazóis/uso terapêutico , Ratos , Relação Estrutura-Atividade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA