1.
J Arrhythm ; 40(3): 647-650, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38939798

RESUMO

We report the behavior of OptiVol2 fluid index (OVFI2) and intrathoracic impedance on remote monitoring before the appearance of signs of infection. A sustained rise in OVFI2 early after implantation reflects peri-device fluid retention.

2.
Circ J ; 88(7): 1147-1154, 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38311419

RESUMO

BACKGROUND: High shock impedance is associated with conversion failure among patients with subcutaneous implantable cardioverter defibrillators (S-ICD). Currently, there is no preoperative assessment method for predicting high shock impedance. This study examined the efficacy of chest computed tomography (CT) as a preoperative evaluation tool to assess the shock impedance of S-ICDs.Methods and Results: The amount of adipose tissue adjacent to the device and anteroposterior diameter at the basal heart region were measured preoperatively using chest CT. We examined the correlation between these measurements and shock impedance at the conversion test. We enrolled 43 patients with S-ICDs (mean [±SD] age 54±15 years; body mass index 23±4 kg/m2; PRAETORIAN score 30-270 points; amount of adipose tissue 1,250±716 cm3), who underwent intraoperative conversion tests by inducing ventricular fibrillation, which was terminated with a 65-J shock. A sufficient concordance correlation coefficient was observed between the shock impedance and the amount of adipose tissue (r=0.616, P<0.01) and anteroposterior diameter (r=0.645, P<0.01). In multiple regression analysis, the amount of adipose tissue (ß=0.439, P=0.009) and anteroposterior diameter (ß=0.344, P=0.038) were identified as independent predictive factors of shock impedance. CONCLUSIONS: The preoperative CT-measured amount of adipose tissue and basal heart anteroposterior diameter are independent predictors of shock impedance. These parameters may be more accurate in identifying higher shock impedance in patients with S-ICDs.


Assuntos
Desfibriladores Implantáveis , Impedância Elétrica , Tomografia Computadorizada por Raios X , Humanos , Pessoa de Meia-Idade , Masculino , Feminino , Idoso , Adulto , Tecido Adiposo/diagnóstico por imagem , Fibrilação Ventricular/terapia , Fibrilação Ventricular/diagnóstico por imagem , Fibrilação Ventricular/fisiopatologia , Valor Preditivo dos Testes
3.
Environ Res ; 244: 115691, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37211177

RESUMO

Environmental changes such as seasonality, decadal oscillation, and anthropogenic forcing may shape the dynamics of lower trophic-level organisms. In this study, 9-years (2010-2018) of monitoring data on microscopic protists such as diatoms and dinoflagellates, and environmental variables were analyzed to clarify the relationships between plankton and local/synoptic environmental changes. We found that time-series temperature increased in May, whereas it decreased in August and November. Nutrients (e.g., phosphate) decreased in May, remained unchanged in August, and increased in November from 2010 to 2018. The partial pressure of CO2 increased in May, August, and November over time. It is notable that the change in seawater temperature (-0.54 to 0.32 °C per year) and CO2 levels (3.6-5.7 µatm CO2 per year) in the latest decade in the eastern Tsugaru Strait were highly dynamic than the projected anthropogenic climate change. Protist abundance generally increased or stayed unchanged during the examined period. In August and November, when cooling and decreases in pH occurred, diatoms such as Chaetoceros subgenus Hyalochaete spp. and Rhizosoleniaceae temporally increased from 2010 to 2018. During the study period, we found that locally aquacultured scallops elevated soft tissue mass relative to the total weight as diatom abundance increased, and the relative scallop soft tissue mass was positively related to the Pacific Decadal Oscillation index. These results indicate that decadal climatic forcing in the ocean modifies the local physical and chemical environment, which strongly affects phytoplankton dynamics rather than the effect of anthropogenic climate change in the eastern Tsugaru Strait.


Assuntos
Dióxido de Carbono , Diatomáceas , Japão , Meteorologia , Água do Mar/química , Aquicultura
4.
Int Heart J ; 64(6): 1157-1161, 2023 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-37967987

RESUMO

A 59-year-old man who had been diagnosed with human immunodeficiency virus-associated cardiomyopathy was referred for catheter ablation of ventricular tachycardia (VT). An electrocardiogram (ECG) waveform revealed that the clinical VT originated from the epicardium. A deceleration zone (DZ) was identified on an isochronal late activation map. Moreover, 2 forms of monomorphic VT were induced by different cycle length burst pacings from near the DZ. The morphologies of the 2 VTs with an identical cycle length were very likely to use a shared common pathway with bi-directional conduction around the slow conduction area in the left ventricle posterolateral small epicardial surface area. After ablation of the DZ, the VT was uninducible.


Assuntos
Cardiomiopatias , Ablação por Cateter , Taquicardia Ventricular , Masculino , Humanos , Pessoa de Meia-Idade , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia , Arritmias Cardíacas/cirurgia , Frequência Cardíaca/fisiologia , Cardiomiopatias/complicações , Cardiomiopatias/diagnóstico , Resultado do Tratamento
5.
Pacing Clin Electrophysiol ; 46(12): 1643-1651, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37904603

RESUMO

BACKGROUND: Predictors of worsening atrioventricular valve regurgitation and left ventricular (LV) systolic function after implantation of a leadless pacemaker (LPM) remain unclear compared with those of a transvenous pacemaker (TPM). METHODS: We retrospectively analyzed 205 patients who were newly implanted with a permanent pacemaker (119 LPMs and 86 TPMs) and underwent transthoracic echocardiography before and 8 ± 5 months after implantation. We evaluated the worsening of tricuspid and mitral regurgitation (TR and MR), defined as at least one-grade aggravation in severity, and changes in LV ejection fraction (LVEF). RESULTS: Worsening TR occurred more frequently in the LPM group compared to the TPM group (33% vs. 20%, p = .04); however, there was no significant difference between the two groups regarding worsening MR (26% vs. 18%, p = .18) and LVEF change (-2 ± 10% vs. -3 ± 8%, p = .40). In multivariable analysis, independent predictors for worsening TR, MR, and LVEF after implantation were found to be (1) the change from sinus rhythm at baseline to atrioventricular asynchronous right ventricular (RV) pacing (odds ratio [OR]: 5.68, 95% confidence interval [CI]: 1.94-16.70, p < .01); (2) the change from non-pacing ventricular contraction at baseline to RV pacing (OR: 2.42, 95% CI: 1.12-5.24, p = .02); and (3) a higher RV pacing burden (ß: -0.05, 95% CI: -0.08--0.02, p < .01), respectively. CONCLUSION: Worsening TR, MR, and LVEF after pacemaker implantation were not associated with the type of pacing device but loss of atrioventricular synchrony or dependency on RV pacing.


Assuntos
Insuficiência da Valva Mitral , Marca-Passo Artificial , Insuficiência da Valva Tricúspide , Humanos , Estimulação Cardíaca Artificial , Estudos Retrospectivos , Função Ventricular Esquerda , Insuficiência da Valva Mitral/terapia
8.
J Innov Card Rhythm Manag ; 14(6): 5491-5498, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37388425

RESUMO

Ventricular-demand leadless pacemakers (VVI-LPMs) have often been used as an alternative to atrioventricular (AV) synchronous transvenous pacemakers (DDD-TPMs) in patients with high-grade AV block following transcatheter aortic valve replacement (TAVR). However, the clinical outcomes of this unusual usage are not elucidated. Patients who received permanent pacemakers (PPMs) owing to new-onset high-grade AV block after TAVR from September 2017 to August 2020 at a high-volume center in Japan were included in the analysis, and the clinical courses of VVI-LPM and DDD-TPM implants through 2 years of follow-up were compared retrospectively. Out of 413 consecutive patients who underwent TAVR, 51 (12%) patients received a PPM. After excluding 8 patients with chronic atrial fibrillation (AF), 3 with sick sinus syndrome, and 1 with incomplete data, 17 VVI-LPMs and 22 DDD-TPMs were included in our final cohort. The VVI-LPM group had lower serum albumin levels (3.2 ± 0.5 vs. 3.9 ± 0.4 g/dL, P < .01) than the DDD-TPM group. Follow-up revealed no significant differences between the 2 groups in terms of the incidence of late device-related adverse events (0% vs. 5%, log-rank P = .38) and new-onset AF (6% vs. 9%, log-rank P = .75); however, there were increases in the rates of all-cause death (41% vs. 5%, log-rank P < .01) and heart failure rehospitalization (24% vs. 0%, log-rank P = .01) in the VVI-LPM group. This small retrospective study reveals favorable post-procedural complication rates but higher all-cause mortality with VVI-LPM compared to DDD-TPM therapy for high-grade AV block after TAVR at 2 years of follow-up.

9.
ASAIO J ; 69(5): 483-489, 2023 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-37126228

RESUMO

There is controversy regarding appropriate surgical ablation procedures concomitant with nonmitral valve surgery. We retrospectively investigated the impact of surgical ablation for atrial fibrillation during aortic valve replacement between 2010 and 2015 in 16 institutions registered through the Japanese Society for Arrhythmia Surgery. Clinical data of 171 patients with paroxysmal and nonparoxysmal atrial fibrillation undergoing aortic valve replacement were collected and classified into full maze operation (n = 79), pulmonary vein isolation (PVI) (n = 56), and no surgical ablation (n = 36) groups. All patients were followed up and electrocardiograms were recorded in 68% at 2 years. The myocardial ischemia time was significantly longer in the maze group than the others during isolated aortic valve replacement (p ≤ 0.01), but there were no significant differences in 30-day or 2-year mortality rates between groups. The ratios of sinus rhythm at 2 years in paroxysmal and nonparoxysmal atrial fibrillation in the maze group versus PVI group were 87% versus 97%, respectively (p = 0.24) and 53% versus 42%, respectively (p = 0.47). No patients with nonparoxysmal atrial fibrillation in the no surgical ablation group maintained sinus rhythm at 2 years. In conclusion, both maze and PVI during aortic valve replacement are valuable strategies to restore sinus rhythm at 2 years and result in favorable early and midterm survival rates.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/cirurgia , Implante de Prótese de Valva Cardíaca , Valva Aórtica/cirurgia , Resultado do Tratamento , Estudos Retrospectivos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais
10.
Intern Med ; 62(17): 2559-2564, 2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-36642517

RESUMO

Paralytic ileus as tuberculosis-immune reconstitution inflammatory syndrome (TB-IRIS) is extremely rare. We herein report a 44-year-old man with pulmonary and renal tuberculosis who developed paralytic ileus 14 days after starting antituberculosis therapy (ATT) despite an initial favorable response to ATT. Paralytic ileus was successfully managed with conservative care. He initially required hemodialysis because of obstructive uropathy due to renal tuberculosis, but he was able to withdraw from dialysis after placement of ureteral stents. TB-IRIS can affect organs other than the original sites of tuberculosis, and the combined use of steroids may be effective for its prevention and treatment.


Assuntos
Antituberculosos , Síndrome Inflamatória da Reconstituição Imune , Pseudo-Obstrução Intestinal , Tuberculose Pulmonar , Tuberculose Renal , Tuberculose Pulmonar/complicações , Tuberculose Pulmonar/diagnóstico por imagem , Tuberculose Pulmonar/tratamento farmacológico , Tuberculose Renal/complicações , Tuberculose Renal/diagnóstico por imagem , Tuberculose Renal/tratamento farmacológico , Humanos , Pseudo-Obstrução Intestinal/diagnóstico , Pseudo-Obstrução Intestinal/etnologia , Síndrome Inflamatória da Reconstituição Imune/complicações , Síndrome Inflamatória da Reconstituição Imune/tratamento farmacológico , Masculino , Adulto , Antituberculosos/uso terapêutico , Tomografia Computadorizada por Raios X
11.
Surg Today ; 53(7): 845-854, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36436023

RESUMO

PURPOSE: To compare the characteristics of reimplantation (RI) using grafts with sinuses and remodeling (RM) with/without external suture annuloplasty using a pulsatile flow simulator. METHODS: Porcine aortic roots were obtained from an abattoir, and six models of RM and RI with sinuses were prepared. External suture annuloplasty (ESA) was performed in the RM models to decrease the root diameter to 22 mm (RM-AP22) and 18 mm (RM-AP18). Valve models were tested at mean pulsatile flow and aortic pressure of 5.0 L/min and 120/80 (100) mmHg, respectively, at 70 beats/min. The forward flow, regurgitation, leakage, backflow rates, valve-closing time, and mean and peak pressure gradient (p-PG) were evaluated. Root configurations were examined using micro-computed tomography (micro-CT). RESULTS: The backflow rate was larger in the RM models than in the RI models (RI: 8.56% ± 0.38% vs. RM: 12.64% ± 0.79%; p < 0.01). The RM-AP and RI models were comparable in terms of the forward flow, regurgitation, backflow rates, p-PG, and valve-closing time. The analysis using a micro-CT showed a larger dilatation of the sinus of the Valsalva in the RM groups than in the RI group (Valsalva: RI, 26.55 ± 0.40 mm vs. RM-AP22, 31.22 ± 0.55 mm [p < 0.05]; RM-AP18, 31.05 ± 0.85 mm [p < 0.05]). CONCLUSIONS: RM with ESA and RI with neo-sinuses showed comparable hemodynamics. ESA to RM reduced regurgitation.


Assuntos
Insuficiência da Valva Aórtica , Valva Aórtica , Hemodinâmica , Reimplante , Animais , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/cirurgia , Fluxo Pulsátil , Suínos , Microtomografia por Raio-X
12.
JACC Case Rep ; 4(23): 101674, 2022 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-36438430

RESUMO

We herein report a case in which we encountered complications when placing an Impella CP ventricular assist device (catheter-based ventricular assist device) in a patient with a Perceval bioprosthetic valve (sutureless valve). Specifically, the catheter-based ventricular assist device became anchored to the sutureless valve and needed to be removed under cardiopulmonary bypass. (Level of Difficulty: Advanced.).

13.
Sci Rep ; 12(1): 8462, 2022 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-35589760

RESUMO

Chlorofluorocarbon (CFC) and sulfur hexafluoride (SF6) were used to investigate the timescale of Antarctic Bottom Water (AABW) that spreads off Cape Darnley (CD) in East Antarctica. The age of the AABW was estimated based on the observed SF6/CFC-12 ratio while taking into account tracer dilution by Lower Circumpolar Deep Water. Along the western canyons off CD and the ~ 3000 to 3500 m isobaths, the bottom water age was < 5 years, reflecting the spread of newly formed CD Bottom Water. Higher ages of ~ 8 years obtained for areas east of CD and > 20 years in the northwestern offshore region indicate inflows of AABW through the Princess Elizabeth Trough and Weddell Sea Deep Water, respectively. This study determined the age distribution in the region off CD, where three different types of AABW spread.


Assuntos
Hexafluoreto de Enxofre , Água , Distribuição por Idade , Regiões Antárticas , Clorofluorcarbonetos
14.
World J Surg ; 46(4): 925-932, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35119510

RESUMO

PURPOSE: The low anterior resection syndrome (LARS) score (LS) has been widely validated and has become an international tool for evaluating postoperative bowel dysfunction. However, many physicians still use the conventional incontinence scores in LARS treatment. Moreover, interpretation of LS and its relationship with conventional incontinence scores are not yet well understood. Here we compared the LS with the Cleveland Clinic Incontinence Score (CCIS) to clarify the clinical utility and characteristics of the LARS score. METHODS: We performed a multicentre observational study, recruiting 246 rectal cancer patients following sphincter-preserving surgery. Patients completed the LS, CCIS, and SF36 questionnaires. RESULTS: The response rate was 76.4%, and a total of 180 patients were analysed. The LS was strongly correlated with the CCIS (P < 0.001, rs = 0.727). However, among 116 patients determined to not have incontinence (CCIS 0-5), 51 (44%) were diagnosed with LARS (29 with minor LARS and 22 with major LARS). Among 68 patients without LARS, only 3 were diagnosed as having incontinence (CCIS > 6). In comparison with background factors, aging and elapsed time were associated with only LS. High LS and CCIS both showed significant quality-of-life impairment as assessed by the SF-36. CONCLUSION: This is the first study to determine the difference in the numeric values between the CCIS and LS. The LS can be a convenient tool for LARS screening, identifying a wide range of patients with LARS, including those with incontinence evaluated by CCIS. Assessment using the CCIS may often underestimate LARS.


Assuntos
Complicações Pós-Operatórias , Neoplasias Retais , Humanos , Complicações Pós-Operatórias/diagnóstico , Qualidade de Vida , Neoplasias Retais/diagnóstico , Neoplasias Retais/cirurgia , Inquéritos e Questionários , Síndrome
15.
Circ J ; 86(8): 1283-1291, 2022 07 25.
Artigo em Inglês | MEDLINE | ID: mdl-35095057

RESUMO

BACKGROUND: Implanting a ventricular demand leadless pacemaker (VVI-LPM) for patients with non-atrial fibrillation (AF) bradyarrhythmias such as sick sinus syndrome (SSS) or high-grade (i.e., second- or third-degree) atrioventricular (AV) block is not recommended unless they have limited vascular access or a high infection risk; nevertheless, an unexpectedly high number of VVI-LPM implantations have been performed. This study investigated the clinical outcomes of these unusual uses.Methods and Results:This study retrospectively analyzed 193 patients who were newly implanted with a VVI-LPM or an atrioventricular synchronous transvenous pacemaker (DDD-TPM) for non-AF bradyarrhythmias at a high-volume center in Japan from September 2017 to September 2020. Propensity score-matching produced 2 comparable cohorts treated with a VVI-LPM or DDD-TPM (n=58 each). Each group had 20 (34%) patients with SSS and 38 (66%) patients with high-grade AV block. During a median follow up of 733 (interquartile range 395-997) days, there were no significant differences between the VVI-LPM and DDD-TPM groups regarding late device-related adverse events (0% vs. 4%, log-rank P=0.155), but the VVI-LPM group had a significantly increased readmission rate for heart failure (HF) (29% vs. 2%, log-rank P=0.001) and a tendency to have higher all-cause mortality (28% vs. 4%, log-rank P=0.059). CONCLUSIONS: The implantation of a VVI-LPM for non-AF bradyarrhythmias increased the incidence of HF-related rehospitalization at the mid-term follow up compared to the use of a DDD-TPM.


Assuntos
Bloqueio Atrioventricular , Insuficiência Cardíaca , Marca-Passo Artificial , Bloqueio Atrioventricular/etiologia , Bloqueio Atrioventricular/terapia , Bradicardia/terapia , Estimulação Cardíaca Artificial/métodos , Seguimentos , Insuficiência Cardíaca/etiologia , Humanos , Marca-Passo Artificial/efeitos adversos , Pontuação de Propensão , Estudos Retrospectivos
16.
Jpn J Clin Oncol ; 52(1): 73-80, 2022 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-34542155

RESUMO

PURPOSE: Osteoporosis is a well-known adverse effect of androgen deprivation therapy for prostate cancer. This study aimed to reveal the factors associated with the diagnosis of osteoporosis in prostate cancer patients undergoing androgen deprivation therapy. METHODS: This retrospective cross-sectional study included 106 prostate cancer patients treated with androgen deprivation therapy. Patients with bone metastasis at the initiation of androgen deprivation therapy and those with castration-resistant prostate cancer were excluded. Bone mineral density was measured at the lumbar spine and femoral neck using dual-energy X-ray absorptiometry. Osteoporosis was defined as bone mineral density equal to or below either -2.5 SD or 70% of the mean in young adults. The association between clinicopathological variables and bone mineral density or diagnosis of osteoporosis was investigated. RESULTS: Thirty-six (34%) patients were found to have osteoporosis. The incidence of osteoporosis increased in a stepwise manner depending on the duration of androgen deprivation therapy. Multivariate logistic regression analysis identified a longer duration of androgen deprivation therapy (months, odd's ratio = 1.017, P = 0.006), lower body mass index (kg/m2, odd's ratio = 0.801, P = 0.005) and higher serum alkaline phosphatase value (U/l, odd's ratio 1.007, P = 0.014) as the factors independently associated with the diagnosis of osteoporosis. Eleven out of 50 (22%), 14 out of 35 (40%) and 11 out of 20 patients (55%) were osteoporotic in the patients with serum alkaline phosphatase values <238 U/l, 238-322 U/l and >322 U/l, respectively (P = 0.022). CONCLUSIONS: Osteoporosis is common in prostate cancer patients undergoing androgen deprivation therapy; furthermore, its incidence increases depending on the duration of androgen deprivation therapy. Bone mineral density testing should be considered for all patients on androgen deprivation therapy, especially for those with a lower body mass index and higher serum alkaline phosphatase value.


Assuntos
Antagonistas de Androgênios , Neoplasias da Próstata , Fosfatase Alcalina , Antagonistas de Androgênios/efeitos adversos , Androgênios , Densidade Óssea , Estudos Transversais , Humanos , Masculino , Neoplasias da Próstata/tratamento farmacológico , Estudos Retrospectivos
17.
Gen Thorac Cardiovasc Surg ; 69(11): 1511-1514, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34510334

RESUMO

A 34-year-old woman was hospitalized with shortness of breath and chest tightness and pain. She had undergone aortic valve replacement for aortic stenosis at the age of 18 years. Transthoracic echocardiography showed left ventricular asynergy and a high aortic valve pressure gradient. Thus, structural valve deterioration was diagnosed. Coronary computed tomography and coronary angiography revealed left main trunk ostial stenosis that had caused acute anteroseptal myocardial infarction. Urgent surgery revealed pannus formation around the prosthetic valve and covering the ostium of the left main trunk. A Bentall procedure and coronary artery bypass grafting were performed. The postoperative course was uneventful.


Assuntos
Valva Aórtica , Pannus , Adulto , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Constrição Patológica , Feminino , Humanos
18.
Circ J ; 85(8): 1265-1272, 2021 07 21.
Artigo em Inglês | MEDLINE | ID: mdl-33790146

RESUMO

BACKGROUND: The optimum cut-off value of premature atrial contraction (PAC) burden (CV-PACb) in 24-h Holter electrocardiography (24-h ECG) for predicting atrial fibrillation (AF) is debatable, with few validation data.Methods and Results:We retrospectively analyzed 61 patients already diagnosed with AF (AD-AF) and 147 patients never diagnosed with AF (ND-AF), aged ≥50 years, free of heart disease, and who had undergone 24-h ECG and transthoracic echocardiography (TTE). Receiver operating characteristic analysis demonstrated that 0.4% was the optimal CV-PACb differentiating AD-AF from ND-AF, with 69% sensitivity and 72% specificity (area under the curve [AUC] 0.72; 95% confidence interval [CI] 0.65-0.79); however, the left atrial volume index was not significant (AUC 0.60; 95% CI 0.51-0.68). To verify the CV-PACb, new propensity-matched cohorts (i.e., subjects with a PAC burden ≥0.4% and <0.4%; n=69 in each group) were compared based on new detection of AF at a median follow-up of 50 months (interquartile range 12-60 months) Multivariable Cox regression analysis revealed that among 24-h ECG and TTE findings, only PAC burden ≥0.4% was independently associated with incident AF (hazard ratio 5.28; 95% CI 1.28-26.11; P=0.023). CONCLUSIONS: A high PAC burden (≥0.4%) in 24-h ECG was a reliable indicator to identify undiagnosed AF, whereas TTE parameters did not show any predictive value.


Assuntos
Fibrilação Atrial , Fibrilação Atrial/diagnóstico , Complexos Atriais Prematuros/diagnóstico , Eletrocardiografia , Eletrocardiografia Ambulatorial , Humanos , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Pontuação de Propensão , Estudos Retrospectivos , Fatores de Risco
19.
J Artif Organs ; 24(2): 245-253, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33484362

RESUMO

The differences in aortic root geometry associated with various valve-sparing root replacement (VSRR) techniques have not fully been understood. We evaluated the root configuration of current VSRR techniques by developing in vitro test apparatus. Six fresh porcine hearts were used for each model. The aortic root remodeling control group involved replacement of the ascending aorta with diameter reduction of sino-tubular junction (STJ) (C1). The aortic valve reimplantation control group involved replacement of the ascending aorta alone (C2). VSRR included remodeling without (RM) or with annuloplasty (RM + A) and reimplantation with a tube (RI) or a handmade neo-Valsalva graft (RI + V). The root geometry of each model in response to closing hydraulic pressures of 80 and 120 mmHg was investigated using echocardiography. Among the VSRR models, RM yielded the largest aorto-ventricular junction (AVJ), which was similar to those in non-VSRR models [mean AVJ diameter (mm) at 80 mmHg; RM = 25.1 ± 1.5, RM + A = 20.9 ± 0.7, RI = 20.7 ± 0.9, RI + V = 20.8 ± 0.4]. RI + V yielded the largest Valsalva size and largest ratio of Valsalva/AVJ, which was similar to the control group [mean Valsalva diameter (mm) at 80 mmHg; RM = 28.4 ± 1.4, RM + A = 25.8 ± 1.3, RI = 23.6 ± 1.0, RI + V = 30.5 ± 0.8, ratio of Valsalva/AVJ at 80 mmHg; RM = 1.14 ± 0.06, RM + A = 1.24 ± 0.06, RI = 1.15 ± 0.06, RI + V = 1.47 ± 0.05]. The STJ diameter at 80 mmHg was numerically smaller with RM + A (22.4 ± 1.2 mm) than with RM (24.8 ± 2.3 mm, p = 0.11). There were no significant differences in AVJ, Valsalva, or STJ distensibility or ellipticity between procedures. Current modifications, including annuloplasty for remodeling or reimplantation in the setting of neo-Valsalva graft, yield near-physiological root geometries.


Assuntos
Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca , Reimplante , Remodelação Ventricular/fisiologia , Animais , Aorta/patologia , Aorta/cirurgia , Valva Aórtica/patologia , Insuficiência da Valva Aórtica/patologia , Insuficiência da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/métodos , Modelos Biológicos , Pressão , Reoperação/métodos , Suínos , Resultado do Tratamento , Valva Tricúspide/cirurgia
20.
J Invasive Cardiol ; 32(10): 400-404, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32999094

RESUMO

OBJECTIVES: Atrioventricular block is a common complication of transcatheter aortic valve implantation (TAVI). Although conventional transvenous dual-chamber (DDD) pacemaker (PM) is ideal for atrioventricular block, leadless PM, which is less invasive, may be suitable for frail TAVI patients. Little is known about clinical outcomes of this newer device following TAVI. METHODS: A total of 330 consecutive patients undergoing TAVI were reviewed. Of these, PM cases without atrial fibrillation were studied. Indication for leadless PM was based on heart team discussion. RESULTS: PM implantations were performed in 30 patients (9.1%), and 24 patients (7.3%) had no atrial fibrillation. These 24 patients had 14 DDD-PMs and 10 leadless PMs, and formed the two study groups. Baseline characteristics were similar except for ejection fraction: median ages were 83.0 years (IQR, 81.0-87.0 years) vs 86.5 years (IQR, 83.5-90.3) (P=.18); 11 (78.6%) vs 8 (80%) were women (P=.67); Society of Thoracic Surgeons scores were 5.1% (IQR, 3.8%-5.9%) vs 5.3% (IQR, 3.4%-8.5%) (P=.82); and ejection fractions were 68.0% (IQR, 66.0%-70.5%) vs 59.0% (IQR, 52.8%-69.3%) (P=.049), for the DDD-PM and leadless PM groups, respectively. There was 1 case of atrial lead dislodgment in the DDD-PM group; otherwise, no complications related to the implantation procedure were found. The leadless PM group showed numerically shorter hospital stay: 12.5 days (range, 9.0-17.8 day) in the DDD-PM group vs 10.5 days (range, 7.8-15.3 days) in the leadless PM group (P=.44). Six-month follow-up revealed no significant differences in incidence of heart failure rehospitalizations or deaths: 2 (14.3%) in the DDD-PM group vs 2 (25%) in the leadless PM group (P=.47); and 2 (14.3%) in the DDD-PM group vs 0 (0%) in the leadless PM group (P=.39), respectively. CONCLUSIONS: Patients with leadless PM following TAVI may have shorter hospital stays, and clinical outcomes can be comparable with DDD-PMs. Leadless PMs may therefore be a reasonable option for frail TAVI patients.


Assuntos
Estenose da Valva Aórtica , Fibrilação Atrial , Bloqueio Atrioventricular , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Feminino , Humanos , Masculino , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA