Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
1.
Catheter Cardiovasc Interv ; 103(5): 803-807, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38415818

RESUMO

In this paper, a case of an 82-year-old man who was admitted to our department with sever symptomatic degenerative aortic valve stenosis is presented and discussed. After all screening procedures, a successful transfemoral transcatheter aortic valve replacement was performed, but the closure of the femoral access was unsuccessful due to suture-based device failure. We decided to perform a prolonged balloon dilatation and external compression at the bleeding site, but the bleeding did not stop; therefore, an iCover stent graft was implanted from distal radial artery access using slender technique. Following that, the bleeding was stopped, and the patient had an uneventful outcome.


Assuntos
Estenose da Valva Aórtica , Cateterismo Periférico , Substituição da Valva Aórtica Transcateter , Masculino , Humanos , Idoso de 80 Anos ou mais , Resultado do Tratamento , Hemorragia/etiologia , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/métodos , Stents/efeitos adversos , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
2.
Interv Cardiol ; 18: e23, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37538386

RESUMO

Patients with calcified, fibrotic native coronary vessels with prior suboptimal stenting outcomes are at major risk of stent thrombosis and could face serious consequences if untreated. In cases of multiple layers of under-expanded stents, the risk is multiplied. If conventional balloon post-dilatation is unsuccessful after stent implantation without proper lesion preparation, few interventional options remain. The authors report on a patient with prior numerous right coronary unsuccessful coronary interventions resulting in partially crushed multiple layers of stent material with critical lumen narrowing caused by stent under-expansion. Balloon angioplasty and stent rotational atherectomy (ROTA) had been attempted to overcome stent under-expansion but were unsuccessful. The authors investigated a new combination therapy of laser atherectomy (ELCA) and super high-pressure balloon (OPN non-compliant balloon) to treat single or multiple layers of stent with severe under-expansion due to fibrotic, calcified tissue surrounding the under-expanded stent structure.

3.
Cardiol J ; 30(1): 6-11, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36510793

RESUMO

Percutaneous coronary intervention (PCI) of chronic total occlusions (CTO) in coronary bifurcation lesions (CBL) is undergoing substantial technical progress and standardization, paralleling the evolution of dedicated devices, tools, and techniques. A standard consensus to classify CTO-CBL might be instrumental to homogenize data collection and description of procedures for scientific and educational purposes. The Medina-CTO classification replicates the classical three digits in Medina classification for bifurcations, representing the proximal main vessel, distal main vessel, and side branch, respectively. Each digit can take a value of 1 if it concerns atherosclerosis and is anatomically stenosed, or 0 if it is not. In addition, the occluded segment(s) of the bifurcation are noted by a subscript, which describes key interventional features of the cap: t (tapered), b (blunt), or a (ambiguous). This approach results in 56 basic categories that can be grouped by means of different elements, depending on the specific needs of each study. Medina-CTO classification, consisting of adding a subscript describing the basic cap characteristics to the totally occluded segment(s) of the standard Medina triplet, might be a useful methodological tool to standardize percutaneous intervention of bifurcational CTO lesions, with interesting scientific and educational applications.


Assuntos
Oclusão Coronária , Intervenção Coronária Percutânea , Humanos , Intervenção Coronária Percutânea/métodos , Angiografia Coronária/métodos , Doença Crônica , Resultado do Tratamento
4.
Methodist Debakey Cardiovasc J ; 18(1): 85-89, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36246498

RESUMO

Dual distal mini-balloon aortic valvuloplasty stabilized an 85-year-old patient with severe aortic stenosis. Puncturing both radial arteries solves the issue of large diameters at the aortic ring, introducing a feasible strategy in selected cases of fragile octogenarian patients with a high hemorrhagic risk. Moving at the anatomical snuffbox offers better postprocedural occlusion rates and better workspace ergonomics during the procedure.


Assuntos
Estenose da Valva Aórtica , Valvuloplastia com Balão , Procedimentos Cirúrgicos Cardíacos , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Valvuloplastia com Balão/efeitos adversos , Valvuloplastia com Balão/métodos , Humanos , Artéria Radial/diagnóstico por imagem
6.
Cardiovasc Revasc Med ; 40: 152-157, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-34848177

RESUMO

BACKGROUND: Although not yet recommended by the guidelines, distal radial access, a new site for cardiovascular interventions, has been rapidly acknowledged and adopted by many centers due to its high rate of success, safety and fewer complications. We present our experience using secondary distal radial access during transcatheter aortic valve implantation (TAVI), proposing a new, even more minimal approach. METHODS: As of November 2020, a systematic distal radial approach as secondary access site for TAVI was adopted in our center. Primary endpoints were technical success and major adverse events (MAEs). Secondary endpoints: the access site complication rate, hemodynamic and clinical results of the intervention, procedural related factors, crossover rate to the femoral access site, and hospitalization duration (in days). RESULTS: From November 2020, 41 patients underwent TAVI using this strategy. Patients had a mean age of 76 ± 11.2 years, 41% were male. Six (14.63%) patients received a balloon-expandable valve and 35 (85.37%) received a self-expandable valve. TAVI was successful in all cases. No complications occurred due to transradial access. Puncture success, defined as completed sheath placement was maximum (N = 41/41,100%) and emergent transfemoral secondary access was not required in any case. Primary transfemoral vascular access site complications occurred in 7 cases (17%) of which 4 (13.63%) were resolved through distal radial access: one occlusion, two flow-limiting stenoses and four perforations of the common femoral artery. There were no additional major vascular complications at 30 days. Overall MACE rate was 2.4%. CONCLUSION: The use of the distal radial approach for secondary access in TAVI is safe, feasible and has several advantages over old access sites.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Feminino , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Artéria Radial/diagnóstico por imagem , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
7.
Life (Basel) ; 13(1)2022 Dec 22.
Artigo em Inglês | MEDLINE | ID: mdl-36675974

RESUMO

In an effort to refine transcatheter vascular interventions, radial artery access has moved more distally at the anatomical snuffbox. Here, more challenges appear as the artery is smaller, more angulated, and more difficult to palpate. Including ultrasound guidance as a mandatory step during puncture may encourage more operators to switch to this approach. In the femoral approach, ultrasound guidance is strongly recommended because of bleeding complications, whereas in the proximal (conventional) radial approach, the role of ultrasound remains optional, and in current practice, almost all cases are performed by palpation of the pulse only. However, in distal radial access, the situation is different because the artery differs in caliber and position, and imaging can help the operator for a clean puncture, especially since repeated punctures are not only painful but also any hematoma formation leads to the complete compression of the artery and failure of access. The aim of this review is to investigate the rationale of vascular ultrasound during distal radial access and to establish some techniques and anatomical landmarks for the ultrasonographic exploration of the dorsal area of the hand.

8.
J Clin Med ; 10(24)2021 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-34945269

RESUMO

INTRODUCTION: Distal radial access (dRA) has recently gained global popularity as an alternative access route for vascular procedures. Among the benefits of dRA are the low risk of entry site bleeding complications, the low rate of radial artery occlusion, and improved patient and operator comfort. The aim of this large multicenter registry was to demonstrate the feasibility and safety of dRA in a wide variety of routine procedures in the catheterization laboratory, ranging from coronary angiography and percutaneous coronary intervention to peripheral procedures. METHODS: The study comprised 1240 patients who underwent coronary angiography, PCI or noncoronary procedures through dRA in two Hungarian centers from January 2019 to April 2021. Baseline patient characteristics, number and duration of arterial punctures, procedural success rate, crossover rate, postoperative compression time, complications, hospitalization duration, and different learning curves were analyzed. RESULTS: The average patient age was 66.4 years, with 66.8% of patients being male. The majority of patients (74.04%) underwent a coronary procedure, whereas 25.96% were involved in noncoronary interventions. dRA was successfully punctured in 97% of all patients, in all cases with ultrasound guidance. Access site crossover was performed in 2.58% of the patients, mainly via the contralateral dRA. After experiencing 150 cases, the dRA success rate plateaued at >96%. Our dedicated dRA step-by step protocol resulted in high open radial artery (RA) rates: distal and proximal RA pulses were palpable in 99.68% of all patients at hospital discharge. The rate of minor vascular complications was low (1.5%). A threshold of 50 cases was sufficient for already skilled radial operators to establish a reliable procedural method of dRA access. CONCLUSION: The implementation of distal radial artery access in the everyday routine of a catheterization laboratory for coronary and noncoronary interventions is feasible and safe with an acceptable learning curve.

9.
EuroIntervention ; 16(9): e724-e733, 2020 Oct 09.
Artigo em Inglês | MEDLINE | ID: mdl-32338608

RESUMO

AIMS: The aim of this study was to assess whether the culotte technique could be improved by an additional kissing dilation prior to main branch (MB) stenting. METHODS AND RESULTS: Double-kissing (DK) culotte was compared to the culotte and DK-crush techniques in a bench model (n=24). Results were evaluated for stent apposition, luminal opening and flow dynamics. The total procedure duration of DK-culotte was 18.3±3.4 minutes, significantly lower than for DK-crush (24.3±5.7 min; p=0.015), but similar to culotte (21.6±5.9 min, p=0.104). In DK-culotte the overall rate of moderate (200-500 µm) and significant (>500 µm) malapposition was 2.1±1.9% and 0.4±0.2%, similar as compared to culotte (3.7±3.8%, p=0.459 and 1.0±1.0%, p=0.517, respectively), and lower as compared to DK-crush (8.1±2.5%, p<0.001 and 3.7±5.3%, p=0.002, respectively). The lower malapposition rate of DK-culotte as compared to DK-crush was due to less moderate and significant malapposition in the proximal MB (0.0±0.0% vs 14.0±7.6%, p<0.001 and 0.0±0.0% vs 4.2±9.1%, p=0.026, respectively). Micro-computed tomography did not show a difference in luminal opening at the proximal MB, distal MB or SB. There was no difference either in the maximum shear rate or in areas of high shear or recirculation. CONCLUSIONS: Bench test data suggest that the DK approach facilitates the culotte technique. The clinical validity and relevance remain to be confirmed in a larger in vivo population.


Assuntos
Doença da Artéria Coronariana , Stents , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Resultado do Tratamento , Microtomografia por Raio-X
11.
Eur J Clin Invest ; 45(7): 692-701, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25944577

RESUMO

AIMS: Peroxynitrite-matrix metalloproteinase (MMP) signalling has been shown to contribute to myocardial ischaemia/reperfusion injury and heart failure and to be influenced by hyperlipidaemia in preclinical models. Therefore, here we investigated the correlation between the markers of peroxynitrite-MMP signalling and hyperlipidaemia in patients with significant coronary stenosis. METHODS: Five minutes before percutaneous coronary intervention (PCI), arterial blood samples were collected from 36 consecutive patients with coronary artery disease (CAD) selected for elective PCI. RESULTS: Serum nitrotyrosine positively correlated with MMP-9 activity (r = 0·54, P = 0·01), but not with MMP-2 activity. Nitrotyrosine positively correlated with total (r = 0·58; P < 0·01) and LDL cholesterol (r = 0·55; P < 0·01), serum triglyceride (r = 0·47; P < 0·05), and creatinine (r = 0·42; P < 0·05) and negatively correlated with HDL cholesterol (r = -0·46; P < 0·05) and with left ventricular ejection fraction (LVEF; r = -0·55; P < 0·05), respectively. MMP-2 activity correlated positively with total (r = 0·55; P < 0·05) and LDL cholesterol (r = 0·45; P < 0·05). In statin-treated patients, a significantly reduced serum nitrotyrosine was found as compared to statin naives; however, MMP activities and serum cholesterol levels were not different. MMP-9 activity correlated with urea nitrogen (r = 0·42; P < 0·05) and LVEF (r = -0·73; P < 0·01). Serum creatinine correlated negatively with LVEF (r = -0·50, P < 0·01). CONCLUSIONS: This is the first demonstration that (i) serum nitrotyrosine correlates with MMP-9 activity, (ii) lipid parameters correlate with nitrotyrosine and MMP-2 activity, (iii) myocardial function correlates with creatinine, nitrotyrosine and MMP-9 activity, and (iv) creatinine correlates with nitrotyrosine and urea nitrogen with MMP-9 activity in patients with CAD. Studying the biomarkers of peroxynitrite-MMP pathway in large prospective trials may reveal their diagnostic avails.


Assuntos
Doença da Artéria Coronariana/sangue , Coração/fisiologia , Metaloproteinase 2 da Matriz/metabolismo , Metaloproteinase 9 da Matriz/metabolismo , Tirosina/análogos & derivados , Idoso , Biomarcadores/metabolismo , Doença da Artéria Coronariana/fisiopatologia , Feminino , Humanos , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Metabolismo dos Lipídeos/fisiologia , Masculino , Nitrogênio/metabolismo , Projetos Piloto , Tirosina/metabolismo , Ureia/química
12.
Postepy Kardiol Interwencyjnej ; 10(2): 141-3, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25061466

RESUMO

We report a 71-year-old man who presented with atypical chest pain. Coronary angiography did not reveal left main or proximal left anterior descending coronary artery stenosis, but a fistulous communication with a stronger tube-like fistula was present originating from the proximal left anterior descending coronary artery and emptying into the main pulmonary artery. Fractional flow reserve and coronary flow reserve measurements were performed to gain more data on the potential functional aspects of this fistula. With the present case, the importance of functional evaluation of these fistulas is demonstrated.

13.
Orv Hetil ; 155(5): 187-93, 2014 Feb 01.
Artigo em Húngaro | MEDLINE | ID: mdl-24463165

RESUMO

INTRODUCTION: It is known that there is a relationship between myocardial perfusion and left ventricular function. AIM: The aim of the current study was to examine the relationship between myocardial reperfusion as assessed by videodensitometry on coronary angiograms following invasive treatment of ST elevation myocardial infarction and magnetic resonance imaging-derived late left ventricular function. METHOD: The study included 25 patients with ST elevation myocardial infarction. A quantitative parameter of myocardial (re)perfusion was calculated by the ratio of maximal density (Gmax) and the time to reach maximum density (Tmax) following invasive treatment. Magnetic resonance imaging was performed 387±262 days after ST elevation myocardial infarction for the evaluation of left ventricular function in all cases. RESULTS: Significant correlations were demonstrated between left ventricular ejection fraction and Gmax (r = 0.40, p = 0.05) and Gmax/Tmax (r = 0.41, p = 0.04) following vessel masking. CONCLUSIONS: The results demonstrate significant relationship between densitometric Gmax/Tmax and late left ventricular function following ST elevation myocardial infarction. Orv. Hetil., 2014. 155(5), 187-193.

14.
Orv Hetil ; 153(32): 1256-62, 2012 Aug 12.
Artigo em Húngaro | MEDLINE | ID: mdl-22878035

RESUMO

UNLABELLED: Aortic valve stenosis may be accompanied by angina despite coronary arteries free of significant stenosis due to microvascular abnormalities. AIMS: The aim of the current study was to test whether densitometry-derived myocardial perfusion on coronary angiogram is reduced in patients with aortic valve stenosis. METHODS: The study comprised 20 patients with aortic valve stenosis (mean transvalvular gradient: 47.4±15.2 mm Hg) and 30 control subjects without significant epicardial coronary artery stenosis. A quantitative parameter of myocardial perfusion was calculated by the ratio of maximal density (Gmax) and time to reach maximum density (Tmax) on time-density curves in regions of interest of each coronary artery on coronary angiograms. RESULTS: Mean three-vessel Gmax/Tmax proved to be significantly lower in patients with aortic valve stenosis compared to control subjects (2.55±1.02 1/sec vs. 3.39±1.09 1/sec, p<0.01). CONCLUSIONS: Reduced Gmax/Tmax values indicative of myocardial perfusion abnormalities as measured by densitometry on coronary angiograms could be demonstrated in patients with aortic valve stenosis compared to controls.


Assuntos
Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico , Angiografia Coronária , Circulação Coronária , Estenose Coronária/complicações , Estenose Coronária/diagnóstico , Adulto , Idoso , Angina Pectoris/etiologia , Estenose da Valva Aórtica/diagnóstico por imagem , Fatores de Confusão Epidemiológicos , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Feminino , Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Projetos de Pesquisa , Tomografia Computadorizada por Raios X
17.
Acta Cardiol ; 65(3): 357-60, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20666279

RESUMO

Coronary fistulas to one of the cardiac chambers are infrequent anomalies and usually are found unexpectedly. Fistulas communicating between coronary artery and left heart chambers are extremely rare, especially those emptying into the left ventricle. We report a case in which all three major coronary arteries emptied into the left ventricle through multiple microfistulas.


Assuntos
Vasos Coronários/patologia , Ventrículos do Coração/patologia , Fístula Vascular/patologia , Antagonistas Adrenérgicos beta/uso terapêutico , Cateterismo Cardíaco , Diagnóstico Diferencial , Ecocardiografia , Eletrocardiografia , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada de Emissão de Fóton Único , Fístula Vascular/diagnóstico , Fístula Vascular/tratamento farmacológico
18.
Ups J Med Sci ; 114(3): 149-53, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19736604

RESUMO

INTRODUCTION: Prognosis after opening the obstructed coronary artery in acute myocardial infarction (AMI) is influenced by several factors. In routine clinical practice, revascularization is considered to be successful when the restoration of epicardial blood-flow is complete. However, the patent epicardial artery does not always provide functional recovery in the myocardium. There are two visual angiographic grades to assess myocardial perfusion: myocardial blush grade (MBG) and TIMI myocardial perfusion grade (TMP). The aim of our study was to compare these two parameters, how they correlate with short-term indicators of myocardial damage. PATIENTS AND METHODS: The two visual grades were assessed along with enzymatic infarct size as creatine kinase release (CK), echocardiographic left ventricular ejection fraction (LVEF), and ST-segment resolution (STR) in 62 patients with acute myocardial infarction and successful revascularization. RESULTS: Better correlation was found with TMP in case of all clinical parameters (CK: R= - 0.687, P<0.001; LVEF: R=0.586, P<0.001; STR: R=0.574, P<0.001). MBG also showed significant correlations with clinical measurements, except for enzymatic infarct size (CK: R=- 0.062, P=0.626; LVEF: R=0.389, P=0.002; STR: R=0.348, P=0.006). CONCLUSION: Our findings suggest that the clearance of the dye (described by TMP) is more characteristic to myocardial recovery after AMI, than maximal contrast density (described by MBG) in the clinical practice.


Assuntos
Angiografia , Infarto do Miocárdio/diagnóstico , Idoso , Creatina Quinase/metabolismo , Ecocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/patologia , Perfusão , Volume Sistólico
19.
Cardiovasc Revasc Med ; 10(2): 73-9, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19327668

RESUMO

BACKGROUND AND PURPOSE: Percutaneous coronary intervention (PCI) via radial approach has been shown to be an alternative to femoral approach in emergency cases; however, its feasibility has been questioned. This single-center study was performed to compare the outcomes and complication rates between transradial (TR) and transfemoral (TF) PCI in ST-segment-elevation myocardial infarction (STEMI). METHODS AND MATERIALS: The clinical and angiographic data of 582 consecutive STEMI patients treated with PCI between 2001 and 2006 were evaluated in a retrospective study. Forty-three patients were excluded from the present study due to cardiogenic shock or rescue PCI. Patients (n=539) were categorized into the TR group (n=167) or the TF group (n=372), and several parameters were evaluated to assess the advantages and drawbacks of TR access: access-site crossover, rate of access-site complications, procedure time, fluoroscopy time, X-ray area dose, major adverse cardiac events (MACE) at 1 month, and consumption of angioplasty equipment. RESULTS: In the TR group, the crossover rate to femoral access was 5%, while in the TF group, it was 0.8% (P<.05). There was a significant difference, in both major and minor access-site complications, between the TR group and the TF group (0% vs. 5%, P<.05, and 4% vs. 9%, P<.05, respectively). Consumption of angioplasty equipment proved to be the same for the two groups. The MACE rate was 4% in the TR group and 11% in the TF group (P<.05). CONCLUSIONS: Our results suggest that the TR approach is a safe and effective way to treat STEMI; furthermore, site-related complications are less common with this approach.


Assuntos
Angioplastia Coronária com Balão/métodos , Artéria Femoral , Infarto do Miocárdio/terapia , Artéria Radial , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/instrumentação , Doenças Cardiovasculares/etiologia , Angiografia Coronária , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico por imagem , Inibidores da Agregação Plaquetária/uso terapêutico , Complexo Glicoproteico GPIIb-IIIa de Plaquetas/antagonistas & inibidores , Estudos Retrospectivos , Stents/estatística & dados numéricos , Fatores de Tempo , Resultado do Tratamento
20.
Cardiovasc Revasc Med ; 10(1): 49-54, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19159855

RESUMO

BACKGROUND: Myocardial perfusion is an important prognostic factor after recanalisation in acute myocardial infarction patients. We present a computerized, densitometric measurement method to assess myocardial perfusion on phase-matched digitally subtracted coronary angiograms. METHODS AND MATERIALS: Quantitative myocardial perfusion was assessed by the G(max)/T(max) parameter of the time-density curves (TDCs) in infarct-related myocardial regions on X-ray coronary angiograms. Arteries were masked out from regions of measurement. This novel method has been compared with enzymatic infarct size, ST-segment resolution, and ejection fraction after successful revascularization of 62 patients with acute myocardial infarction. RESULTS: Significant correlations were found between G(max)/T(max) and enzymatic infarct size (R=-0.445, P<.001), ST-segment resolution (R=0.364, P=.004), and ejection fraction (R=0.278, P=.029). Bland and Altman plot of G(max)/T(max) reveals good interobserver agreement. CONCLUSIONS: G(max)/T(max) of the TDC measured in the infarct-related myocardial area is a reliable parameter to assess clinical indicators of myocardial reperfusion. Therefore, results suggest that it could be used to immediately assess the success of recanalisation at the tissue perfusion level during coronary intervention, and as an objective end point in clinical trials of new interventional devices and drugs.


Assuntos
Angiografia Digital , Cineangiografia , Angiografia Coronária/métodos , Circulação Coronária , Densitometria , Infarto do Miocárdio/diagnóstico , Imagem de Perfusão do Miocárdio , Idoso , Angioplastia Coronária com Balão , Biomarcadores/sangue , Creatina Quinase/sangue , Ecocardiografia , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/fisiopatologia , Infarto do Miocárdio/terapia , Miocárdio/patologia , Variações Dependentes do Observador , Valor Preditivo dos Testes , Interpretação de Imagem Radiográfica Assistida por Computador , Reprodutibilidade dos Testes , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA