Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.073
Filtrar
1.
Phys Rev Lett ; 132(9): 091901, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38489625

RESUMO

We perform the first global quantum chromodynamics (QCD) analysis of dihadron production for a comprehensive set of data in electron-positron annihilation, semi-inclusive deep-inelastic scattering, and proton-proton collisions, from which we extract simultaneously the transversity distributions of the nucleon and π^{+}π^{-} dihadron fragmentation functions. We incorporate in our fits known theoretical constraints on transversity, namely, its small-x asymptotic behavior and the Soffer bound. We furthermore show that lattice-QCD results for the tensor charges can be successfully included in the analysis. This resolves the previously reported incompatibility between the tensor charges extracted from dihadron production data and lattice QCD. We also find agreement with results for the transversity and tensor charges obtained from measurements on single-hadron production. Overall, our work demonstrates for the first time the universal nature of all available information for the transversity distributions and the tensor charges of the nucleon.

2.
Phys Rev Lett ; 132(1): 011902, 2024 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-38242654

RESUMO

We present a new quantum field-theoretic definition of fully unintegrated dihadron fragmentation functions (DiFFs) as well as a generalized version for n-hadron fragmentation functions. We demonstrate that this definition allows certain sum rules to be satisfied, making it consistent with a number density interpretation. Moreover, we show how our corresponding so-called extended DiFFs that enter existing phenomenological studies are number densities and also derive their evolution equations. Within this new framework, DiFFs extracted from experimental measurements will have a clear physical meaning.

4.
J Dent Res ; 102(1): 21-27, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36085580

RESUMO

Because a relationship has been reported between masticatory behavior, obesity, and postprandial blood glucose, it is recommended to chew well and take a longer time to eat. The purpose of this study was to examine the possibility of changing masticatory behavior using a small ear-hung wearable chewing counter, which can monitor masticatory behavior without disturbing daily meals. In total, 235 healthy volunteers participated in a 4-wk randomized controlled trial and were divided into 3 groups. All participants were instructed about the importance of mastication at the first visit. During the intervention, group B used the chewing counter without an algorithm during each meal (notification of the number of chews after meal), and group C used the chewing counter with a masticatory behavior change algorithm (setting a target value and displaying the number of chews in real time). Group A was set as the control group. The number of chews and the meal time when consuming 1 rice ball (100 g) were measured before and after the intervention using the chewing counter, and the rate of change in these values was evaluated. Participants also provided a subjective evaluation of their changes in masticatory behavior. The number of chews and the meal time of 1 rice ball increased significantly in groups B and C compared with before the intervention, and the rate of change was significantly higher in group C than in group A and group B. In addition, the subjective evaluation of the change in the number of chews was highest in group C. Self-monitoring of masticatory behavior by providing a target value and the degree of achievement for the number of chews using a wearable chewing counter with a behavioral change algorithm could promote effective change in masticatory behavior and lead to an increased number of chews. (Trial ID: UMIN000034476).


Assuntos
Mastigação , Dispositivos Eletrônicos Vestíveis , Humanos , Comportamento Alimentar , Obesidade
5.
AJNR Am J Neuroradiol ; 43(8): 1202-1209, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35835590

RESUMO

BACKGROUND AND PURPOSE: CNS lesions of tuberous sclerosis complex are diagnosed mainly by T2WI, FLAIR, and sometimes T1WI with magnetization transfer contrast. The usefulness of T1WI with chemical shift selective images was recently reported in focal cortical dysplasia type IIb, which has histopathologic and imaging features similar to those of tuberous sclerosis complex. We investigated the usefulness of the T1WI with chemical shift selective images in detecting CNS lesions of tuberous sclerosis complex. MATERIALS AND METHODS: We retrospectively reviewed 25 consecutive patients with tuberous sclerosis complex (mean age, 11.9 [SD, 8.9] years; 14 males) who underwent MR imaging including T1WI, T1WI with magnetization transfer contrast, T1WI with chemical shift selective, T2WI, and FLAIR images. Two neuroradiologists assessed the number of CNS lesions in each sequence and compared them in 2 steps: among T1WI, T1WI with magnetization transfer contrast and T1WI with chemical shift selective images, and among T2WI, FLAIR, and T1WI with chemical shift selective images. We calculated the contrast ratio of the cortical tubers and of adjacent normal-appearing gray matter and the contrast ratio of radial migration lines and adjacent normal-appearing white matter in each sequence and compared them. RESULTS: T1WI with chemical shift selective images was significantly superior to T1WI with magnetization transfer contrast for the detection of radial migration lines and contrast ratio of radial migration lines. There was no significant difference between T1WI with chemical shift selective images and T1WI with magnetization transfer contrast for the detection of cortical tubers and the contrast ratio of the cortical tubers. Both T2WI and FLAIR were statistically superior to T1WI with chemical shift selective images for the detection of cortical tubers. T1WI with chemical shift selective images was significantly superior to T2WI and FLAIR for the detection of radial migration lines. CONCLUSIONS: The usefulness of T1WI with chemical shift selective images in detecting radial migration lines was demonstrated. Our findings suggest that the combination of T1WI with chemical shift selective images, T2WI, and FLAIR would be useful to evaluate the CNS lesions of patients with tuberous sclerosis complex in daily clinical practice.


Assuntos
Epilepsia , Esclerose Tuberosa , Masculino , Humanos , Criança , Esclerose Tuberosa/complicações , Esclerose Tuberosa/diagnóstico por imagem , Estudos Retrospectivos , Substância Cinzenta , Imageamento por Ressonância Magnética/métodos
6.
Phys Rev Lett ; 127(24): 242001, 2021 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-34951781

RESUMO

We report the results of a Monte Carlo global QCD analysis of unpolarized parton distribution functions (PDFs), including for the first time constraints from ratios of ^{3}He to ^{3}H structure functions recently obtained by the MARATHON experiment at Jefferson Lab. Our simultaneous analysis of nucleon PDFs and nuclear effects in A=2 and A=3 nuclei reveals the first indication for an isovector nuclear EMC effect in light nuclei. We find that while the MARATHON data yield relatively weak constraints on the F_{2}^{n}/F_{2}^{p} neutron to proton structure function ratio and on the d/u PDF ratio, they suggest an enhanced nuclear effect on the d-quark PDF in the bound proton, questioning the assumptions commonly made in nuclear PDF analyses.

7.
Phys Rev Lett ; 127(23): 232001, 2021 Dec 03.
Artigo em Inglês | MEDLINE | ID: mdl-34936801

RESUMO

We perform the first global QCD analysis of pion valence, sea quark, and gluon distributions within a Bayesian Monte Carlo framework with threshold resummation on Drell-Yan cross sections at next-to-leading log accuracy. Exploring various treatments of resummation, we find that the large-x asymptotics of the valence quark distribution ∼(1-x)^{ß_{v}} can differ significantly, with ß_{v} ranging from ≈1 to >2.5 at the input scale. Regardless of the specific implementation, however, the resummation induced redistribution of the momentum between valence quarks and gluons boosts the total momentum carried by gluons to ≈40%, increasing the gluon contribution to the pion mass to ≈40 MeV.

8.
Phys Rev Lett ; 126(13): 137201, 2021 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-33861132

RESUMO

We present an experimental study of time refraction of spin waves (SWs) propagating in microscopic waveguides under the influence of time-varying magnetic fields. Using space- and time-resolved Brillouin light scattering microscopy, we demonstrate that the broken translational symmetry along the time coordinate results in a loss of energy conservation for SWs and thus allows for a broadband and controllable shift of the SW frequency. With an integrated design of SW waveguide and microscopic current line for the generation of strong, nanosecond-long, magnetic field pulses, a conversion efficiency up to 39% of the carrier SW frequency is achieved, significantly larger compared to photonic systems. Given the strength of the magnetic field pulses and its strong impact on the SW dispersion relation, the effect of time refraction can be quantified on a length scale comparable to the SW wavelength. Furthermore, we utilize time refraction to excite SW bursts with pulse durations in the nanosecond range and a frequency shift depending on the pulse polarity.

9.
AJNR Am J Neuroradiol ; 41(9): 1683-1689, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32763900

RESUMO

BACKGROUND AND PURPOSE: Hypophysitis is one of the well-known adverse effects of immune checkpoint inhibitors. Immune checkpoint inhibitor-induced hypophysitis frequently causes irreversible hypopituitarism, which requires long-term hormone replacement. Despite the high frequency and clinical significance, characteristic MR imaging findings of immune checkpoint inhibitor-induced hypophysitis have not been established. In the present study, we aimed to review and extract the MR imaging features of immune checkpoint inhibitor-induced hypophysitis. MATERIALS AND METHODS: This retrospective international multicenter study comprised 20 patients with melanoma who were being treated with immune checkpoint inhibitors and clinically diagnosed with immune checkpoint inhibitor-induced hypophysitis. Three radiologists evaluated the following MR imaging findings: enlargement of the pituitary gland and stalk; homogeneity of enhancement of the pituitary gland; presence/absence of a well-defined poorly enhanced area and, if present, its location, shape, and signal intensity in T2WI; and enhancement pattern in contrast-enhanced dynamic MR imaging. Clinical symptoms and hormone levels were also recorded. RESULTS: Enlargement of the pituitary gland and stalk was observed in 12 and 20 patients, respectively. Nineteen patients showed poorly enhanced lesions (geographic hypoenhancing lesions) in the anterior lobe, and 11 of these lesions showed hypointensity on T2WI. Thyrotropin deficiency and corticotropin deficiency were observed in 19/20 and 12/17 patients, respectively, which persisted in 12/19 and 10/12 patients, respectively, throughout the study period. CONCLUSIONS: Pituitary geographic hypoenhancing lesions in the anterior lobe of the pituitary gland are characteristic and frequent MR imaging findings of immune checkpoint inhibitor-induced hypophysitis. They reflect fibrosis and are useful in distinguishing immune checkpoint inhibitor-induced hypophysitis from other types of hypophysitis/tumors.


Assuntos
Hipofisite/induzido quimicamente , Hipofisite/patologia , Inibidores de Checkpoint Imunológico/efeitos adversos , Melanoma/tratamento farmacológico , Neoplasias Cutâneas/tratamento farmacológico , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Fibrose/induzido quimicamente , Fibrose/diagnóstico por imagem , Fibrose/patologia , Humanos , Hipofisite/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Melanoma Maligno Cutâneo
10.
AJNR Am J Neuroradiol ; 41(6): 1094-1098, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32439644

RESUMO

BACKGROUND AND PURPOSE: Leptomeningeal glioneuronal heterotopia of the brain stem and cerebral migration abnormality were pathologically reported in Fukuyama congenital muscular dystrophy, but the radiologic assessments of the brain stem and cerebral venous system (which may be involved in the development of the anomaly) were insufficient. Here, we evaluated the brain stem and cerebral veins on MR imaging in patients with Fukuyama congenital muscular dystrophy. MATERIALS AND METHODS: We retrospectively reviewed the MR imaging findings of 27 patients with Fukuyama congenital muscular dystrophy. We visually assessed the hypoplasia, superficial structures, and signal intensity of the brain stem on T2WI, FLAIR, and double inversion recovery images and the cerebral, superficial, and deep veins with and without hemorrhage on T2WI and SWI. RESULTS: Brain stem fluffy structures were seen in 96.3% of the cases on T2WI. Superficial high signal intensity on T2WI and FLAIR images was seen in 96.3% and 92.6%, respectively. Abnormally located superficial vessels beneath the cortex were seen in 11.1% on T2WI. Hypoplasia of the superficial cerebral veins was noted in all patients who underwent SWI. Dilated and tortuous subependymal veins were seen in 40.0% on SWI. Hemorrhages were seen in 11.1% on T2WI and in 60.0% on SWI. CONCLUSIONS: Superficial brain stem structural and signal abnormalities would be useful MR imaging findings to diagnose Fukuyama congenital muscular dystrophy as well as venous system abnormalities. Clinicians must keep in mind that this disease has a high risk of hemorrhage.


Assuntos
Tronco Encefálico/anormalidades , Veias Cerebrais/anormalidades , Síndrome de Walker-Warburg/diagnóstico por imagem , Adolescente , Tronco Encefálico/diagnóstico por imagem , Veias Cerebrais/diagnóstico por imagem , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Imageamento por Ressonância Magnética/métodos , Masculino , Neuroimagem/métodos , Estudos Retrospectivos , Adulto Jovem
11.
Int J Oral Maxillofac Surg ; 49(4): 432-441, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31451304

RESUMO

The objective was to introduce a new technique for visualizing the three-dimensional (3D) movements of velopharyngeal-related muscles using high-speed cine-magnetic resonance imaging (MRI) based on T2-weighted sequences. The evaluation of phonation- and water swallowing-related events was performed in 11 healthy subjects. Specifically, whether cine-MRI could precisely visualize normal velopharyngeal function during these two events was examined. The 3D movements of the soft palate, superior pharyngeal constrictor muscles, and levator veli palatini muscles were visualized in all 11 subjects. A noteworthy finding was that the magnetic resonance signals of the superior constrictor pharyngeal muscles and the levator veli palatini muscles were significantly higher during phonation and during water swallowing than at rest. This initial study suggests that the 3D movements of velopharyngeal-related muscles can be successfully and precisely visualized without side effects. The magnetic resonance signal changes seen in the superior pharyngeal constrictor and levator veli palatini muscles using the technique described here should be useful to develop better methods of evaluation of velopharyngeal function.


Assuntos
Insuficiência Velofaríngea , Humanos , Imageamento por Ressonância Magnética , Músculos Palatinos , Palato Mole , Músculos Faríngeos
12.
Phys Rev Lett ; 123(5): 057204, 2019 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-31491302

RESUMO

In the last decade, two revolutionary concepts in nanomagnetism emerged from research for storage technologies and advanced information processing. The first suggests the use of magnetic domain walls in ferromagnetic nanowires to permanently store information in domain-wall racetrack memories. The second proposes a hardware realization of neuromorphic computing in nanomagnets using nonlinear magnetic oscillations in the gigahertz range. Both ideas originate from the transfer of angular momentum from conduction electrons to localized spins in ferromagnets, either to push data encoded in domain walls along nanowires or to sustain magnetic oscillations in artificial neurones. Even though both concepts share a common ground, they live on very different timescales which rendered them incompatible so far. Here, we bridge both ideas by demonstrating the excitation of magnetic auto-oscillations inside nanoscale domain walls using pure spin currents. This Letter will shed light on the current characteristic and spatial distribution of the excited auto-oscillations.

14.
AJNR Am J Neuroradiol ; 40(6): 1060-1066, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-31097427

RESUMO

BACKGROUND AND PURPOSE: The transmantle sign is a characteristic MR imaging finding often seen in focal cortical dysplasia type IIb. The transmantle sign is typically hyperintense on T2WI and FLAIR and hypointense on T1WI. However, in some cases, it shows T1 high signal. We evaluated the imaging and pathologic findings to identify the causes of the T1 high signal in the transmantle sign. MATERIALS AND METHODS: We retrospectively reviewed the preoperative imaging data of 141 consecutive patients with histologically proved focal cortical dysplasia. We selected 25 patients with focal cortical dysplasia with the transmantle sign and divided them into groups based on the pathologic focal cortical dysplasia subtype and T1 signal of the transmantle sign. We evaluated the clinical, radiologic, and pathologic findings, including the number of balloon cells and dysmorphic neurons and the severity of gliosis or calcifications and compared them among the groups. RESULTS: Nine of the 25 patients had a T1-high-signal transmantle sign; the other 16 patients did not. All 9 patients with a T1-high-signal transmantle sign were diagnosed as type IIb (group A). Of the 16 patients with no T1-high-signal transmantle sign, 13 were diagnosed as having type IIb (group B), and the other 3 patients, as type IIa (group C). The number of balloon cells was significantly higher in group A than in the other groups, but there were no differences regarding dysmorphic neurons, the severity of gliosis, or calcifications. CONCLUSIONS: Approximately 6% (9/141) of this patient series had a T1-high-signal transmantle sign, and all were type IIb. The signal may reflect a rich density of balloon cells. This finding could support the differentiation of subtypes, especially type IIb.


Assuntos
Epilepsia/diagnóstico por imagem , Epilepsia/patologia , Imageamento por Ressonância Magnética/métodos , Malformações do Desenvolvimento Cortical do Grupo I/diagnóstico por imagem , Malformações do Desenvolvimento Cortical do Grupo I/patologia , Neuroimagem/métodos , Adolescente , Adulto , Criança , Pré-Escolar , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Estudos Retrospectivos , Adulto Jovem
15.
Int J Oral Maxillofac Surg ; 48(4): 480-487, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30316661

RESUMO

The aim of this study was to determine whether the evaluation of neurovascular compression (NVC) using new criteria on magnetic resonance (MR) cisternography improves the prediction of the curative effects of carbamazepine (CBZ) in trigeminal neuralgia (TN). In this study, a new analysis of NVC using MR cisternography was performed retrospectively for 280 patients with clinical signs and symptoms suggesting TN. The new analysis examined whether the site of the NVC was less than 3mm from the edge of the exit point and within the first third of the root entry zone on MR cisternography. Prediction of the curative effects of CBZ using the new evaluation of distance to the NVC improved on the predictive ability of the previous method of calculating the NVC volume (Mantel-Haenszel coefficient, P<0.01). In particular, initial treatment with CBZ 100mg/day for 2 weeks appeared more effective for patients with NVC volumes of ≤5mm3 plus a distance to the NVC of ≤3mm, than for those with NVC volumes >5mm3. The evaluation of NVC on MR cisternography using this new approach appears to be more useful than the previous method for predicting the initial treatment response in patients with TN.


Assuntos
Neuralgia do Trigêmeo , Angiografia , Carbamazepina , Humanos , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Estudos Retrospectivos
16.
Phys Rev Lett ; 121(15): 152001, 2018 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-30362780

RESUMO

We perform the first global QCD analysis of parton distribution functions (PDFs) in the pion, combining πA Drell-Yan data with leading neutron electroproduction from HERA within a Monte Carlo approach based on nested sampling. Inclusion of the HERA data allows the pion PDFs to be determined down to much lower values of x, with relatively weak model dependence from uncertainties in the chiral splitting function. The combined analysis reveals that gluons carry a significantly higher pion momentum fraction, ∼30%, than that inferred from Drell-Yan data alone, with sea quarks carrying a somewhat smaller fraction, ∼15%, at the input scale. Within the same effective theory framework, the chiral splitting function and pion PDFs can be used to describe the d[over ¯]-u[over ¯] asymmetry in the proton.

18.
Phys Rev Lett ; 120(15): 152502, 2018 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-29756858

RESUMO

We report on the first global QCD analysis of the quark transversity distributions in the nucleon from semi-inclusive deep-inelastic scattering (SIDIS), using a new Monte Carlo method based on nested sampling and constraints on the isovector tensor charge g_{T} from lattice QCD. A simultaneous fit to the available SIDIS Collins asymmetry data is compatible with g_{T} values extracted from a comprehensive reanalysis of existing lattice simulations, in contrast to previous analyses, which found significantly smaller g_{T} values. The contributions to the nucleon tensor charge from u and d quarks are found to be δu=0.3(2) and δd=-0.7(2) at a scale Q^{2}=2 GeV^{2}.

19.
Br J Surg ; 105(9): 1192-1199, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29683188

RESUMO

BACKGROUND: Liver fibrosis is a risk factor for hepatectomy but cannot be determined accurately before hepatectomy because diagnostic procedures are too invasive. Magnetic resonance elastography (MRE) can determine liver stiffness (LS), a surrogate marker for assessing liver fibrosis, non-invasively. The aim of this study was to investigate whether the LS value determined by MRE is predictive of major complications after hepatectomy. METHODS: This prospective study enrolled consecutive patients who underwent hepatic resection between April 2013 and August 2016. LS values were measured by imaging shear waves by MRE in the liver before hepatectomy. The primary endpoint was major complications, defined as Clavien-Dindo grade IIIa or above. Logistic regression analysis identified independent predictive factors, from which a logistic model to estimate the probability of major complications was constructed. RESULTS: A total of 96 patients were included in the study. Major complications were observed in 15 patients (16 per cent). Multivariable logistic analysis confirmed that higher LS value (P = 0·021) and serum albumin level (P = 0·009) were independent predictive factors for major complications after hepatectomy. Receiver operating characteristic (ROC) analysis showed that the best LS cut-off value was 4·3 kPa for detecting major complications, comparable to liver fibrosis grade F4, with a sensitivity of 80 per cent and specificity of 82 per cent. A logistic model using the LS value and serum albumin level to estimate the probability of major complications was constructed; the area under the ROC curve for predicting major complications was 0·84. CONCLUSION: The LS value determined by MRE in patients undergoing hepatectomy was an independent predictive factor for major complications.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Hepatectomia/efeitos adversos , Cirrose Hepática/cirurgia , Fígado/diagnóstico por imagem , Complicações Pós-Operatórias/diagnóstico , Idoso , Fenômenos Biomecânicos , Feminino , Seguimentos , Humanos , Incidência , Japão/epidemiologia , Fígado/fisiopatologia , Fígado/cirurgia , Cirrose Hepática/diagnóstico , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Valor Preditivo dos Testes , Estudos Prospectivos
20.
Phys Rev E ; 97(2-1): 022145, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29548248

RESUMO

Topological constraints on a dynamical system often manifest themselves as breaking of the Hamiltonian structure; well-known examples are nonholonomic constraints on Lagrangian mechanics. The statistical mechanics under such topological constraints is the subject of this study. Conventional arguments based on phase spaces, Jacobi identity, invariant measure, or the H theorem are no longer applicable since all these notions stem from the symplectic geometry underlying canonical Hamiltonian systems. Remembering that Hamiltonian systems are endowed with field tensors (canonical 2-forms) that have zero helicity, our mission is to extend the scope toward the class of systems governed by finite-helicity field tensors. Here, we introduce a class of field tensors that are characterized by Beltrami vectors. We prove an H theorem for this Beltrami class. The most general class of energy-conserving systems are non-Beltrami, for which we identify the "field charge" that prevents the entropy to maximize, resulting in creation of heterogeneous distributions. The essence of the theory can be delineated by classifying three-dimensional dynamics. We then generalize to arbitrary (finite) dimensions.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA