Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
1.
Anaesthesist ; 69(9): 611-622, 2020 09.
Artigo em Alemão | MEDLINE | ID: mdl-32296866

RESUMO

BACKGROUND: Measurement of blood pressure is part of standard monitoring procedures in anesthesia, in addition to the other vital parameters of heart frequency and peripheral oxygen saturation. In recent years the relevance of the duration and extent of perioperative episodes of hypotension for the occurrence of postoperative complications or even increased mortality have become the focus of scientific investigations. OBJECTIVE: The aim of this review is to briefly recapitulate the physiological aspects of blood pressure and to describe the pathophysiology and risk factors of perioperative hypotension. It describes which potential organ damage can be caused by hypotension and discusses which perioperative blood pressure values are acceptable without harming the patient. METHODS: Review and analysis of the currently available literature. RESULTS: Perioperative hypotension is defined by either absolute systolic arterial pressure (SAP) or mean arterial pressure (MAP) thresholds and by relative blood pressure declines from an individual preoperative baseline value. For the definition of absolute and relative thresholds it needs to be considered that the ultimate target is an adequate perfusion pressure (and not the MAP) and that the preinduction blood pressure is a poor reflection of the patients' normal blood pressure profile. Risk factors for an intraoperative drop in blood pressure are advanced age, higher American Society of Anesthesiologists (ASA) status, low blood pressure prior to induction of anesthesia, the premedication, e.g. angiotensin-converting enzyme (ACE) inhibitors, the anesthesia technique (combination of general and epidural anesthesia) and emergency surgery. The lowest tolerable intraoperative blood pressure should be defined according to the individual patient's preoperative blood pressure and risk profile. Individual thresholds should be determined for the severity and duration of intraoperative hypotension. Empirically, MAP values <65 mm Hg and relative pressure declines of >20-30% are often recommended as thresholds. Below critical blood pressure values the risk of postoperative organ damage (myocardium, kidneys and central nervous system) and mortality increases with longer duration of hypotension. Older people and high-risk patients (e.g. patients in vascular surgery) have a poorer and shorter tolerance of low blood pressure. Postoperative organ complications can be minimized by maintenance of an adequate intraoperative blood pressure CONCLUSION: Anesthesiologists should avoid extensive and prolonged hypotension by timely interventions in order to improve the postoperative outcome of patients.


Assuntos
Pressão Sanguínea/fisiologia , Hipotensão/complicações , Hipotensão/fisiopatologia , Período Perioperatório , Determinação da Pressão Arterial , Humanos , Hipotensão/diagnóstico
2.
Anaesthesist ; 68(9): 637-650, 2019 09.
Artigo em Alemão | MEDLINE | ID: mdl-31270554

RESUMO

The determination of arterial blood pressure is a fundamental part of basic cardiovascular monitoring in perioperative, intensive care and emergency medicine. Blood pressure can be measured directly via an arterial catheter, which is the most accurate method. Blood pressure is most commonly monitored using noninvasive intermittent methods with an occluding upper arm cuff. Noninvasive intermittent blood pressure measurements can also be performed either manually using palpation and auscultation or automatically based on an oscillometric algorithm. Furthermore, methods such as the vascular unloading technique with a finger plethysmographic sensor are available for continuous and noninvasive blood pressure monitoring. This article explains the principles of the individual methods, the sources of errors, advantages and disadvantages and discusses the fields of application in the clinical routine.


Assuntos
Pressão Arterial , Determinação da Pressão Arterial/métodos , Cuidados Críticos , Humanos , Monitorização Fisiológica , Oscilometria
3.
Intensive Care Med ; 45(4): 434-446, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30778648

RESUMO

Over the past two decades, ultrasound (US) has become widely accepted to guide safe and accurate insertion of vascular devices in critically ill patients. We emphasize central venous catheter insertion, given its broad application in critically ill patients, but also review the use of US for accessing peripheral veins, arteries, the medullary canal, and vessels for institution of extracorporeal life support. To ensure procedural safety and high cannulation success rates we recommend using a systematic protocolized approach for US-guided vascular access in elective clinical situations. A standardized approach minimizes variability in clinical practice, provides a framework for education and training, facilitates implementation, and enables quality analysis. This review will address the state of US-guided vascular access, including current practice and future directions.


Assuntos
Cateterismo Venoso Central/instrumentação , Ultrassonografia de Intervenção/métodos , Dispositivos de Acesso Vascular/normas , Cateterismo Venoso Central/efeitos adversos , Cateterismo Venoso Central/métodos , Estado Terminal/terapia , Humanos , Ultrassonografia de Intervenção/efeitos adversos , Ultrassonografia de Intervenção/instrumentação , Dispositivos de Acesso Vascular/tendências
4.
Med Klin Intensivmed Notfmed ; 113(3): 192-201, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-28474097

RESUMO

BACKGROUND: Advanced hemodynamic monitoring is recommended in patients with complex circulatory shock. OBJECTIVES: To evaluate the current attitudes and beliefs among German intensivists, regarding advanced hemodynamic monitoring, the actual hemodynamic management in clinical practice, and the barriers to using it. MATERIALS AND METHODS: Web-based survey among members of the German Society of Medical Intensive Care and Emergency Medicine. RESULTS: Of 284 respondents, 249 (87%) agreed that further hemodynamic assessment is needed to determine the type of circulatory shock if no clear clinical diagnosis can be made. In all, 281 (99%) agreed that echocardiography is helpful for this purpose (transpulmonary thermodilution: 225 [79%]; pulmonary artery catheterization: 126 [45%]). More than 70% of respondents agreed that blood flow variables (cardiac output, stroke volume) should be measured in patients with hemodynamic instability. The parameters most respondents agreed should be assessed in a patient with hemodynamic instability were mean arterial pressure, cardiac output, and serum lactate. Echocardiography is available in 99% of ICUs (transpulmonary thermodilution: 91%; pulmonary artery catheter: 63%). The respondents stated that, in clinical practice, invasive arterial pressure measurements and serum lactate measurements are performed in more than 90% of patients with hemodynamic instability (cardiac output monitoring in about 50%; transpulmonary thermodilution in about 40%). The respondents did not feel strong barriers to the use of advanced hemodynamic monitoring in clinical practice. CONCLUSIONS: This survey study shows that German intensivists deem advanced hemodynamic assessment necessary for the differential diagnosis of circulatory shock and to guide therapy with fluids, vasopressors, and inotropes in ICU patients.


Assuntos
Cuidados Críticos , Monitorização Hemodinâmica , Padrões de Prática Médica , Atitude do Pessoal de Saúde , Débito Cardíaco , Hemodinâmica , Humanos , Internet , Monitorização Fisiológica , Inquéritos e Questionários , Termodiluição
5.
Br J Anaesth ; 119(1): 57-64, 2017 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-28974066

RESUMO

BACKGROUND: We hypothesized that different phases of intraoperative hypotension should be differentiated because of different underlying causative mechanisms. We defined post-induction hypotension (PIH; i.e. arterial hypotension occurring during the first 20 min after anaesthesia induction) and early intraoperative hypotension (eIOH; i.e. arterial hypotension during the first 30 min of surgery). METHODS: In this retrospective study, we included 2037 adult patients who underwent general anaesthesia. Arterial hypotension was defined as a systolic arterial blood pressure (SAP) <90 mm Hg or a need for norepinephrine infusion at > 6 µg min -1 at least once during the phases of PIH and eIOH. Multivariate logistic regression analysis was used to test for association of clinical factors with PIH and eIOH. RESULTS: Independent variables significantly related to PIH were pre-induction SAP [odds ratio (OR) 0.97 (95% confidence interval 0.97-0.98)], age [OR 1.03 (1.02-1.04)], and emergency surgery [OR 1.75 (1.20-2.56); P <0.01 each]. Pre-induction SAP [OR 0.99 (0.98-0.99), P <0.01], age [OR 1.02 (1.02-1.03), P <0.01], emergency surgery [OR 1.83 (1.28-2.62), P <0.01], supplementary administration of spinal or epidural anaesthetic techniques [OR 3.57 (2.41-5.29), P <0.01], male sex [OR 1.41 (1.12-1.79), P <0.01], and ASA physical status IV [OR 2.18 (1.19-3.99), P =0.01] were significantly related to eIOH. CONCLUSIONS: We identified clinical factors associated with PIH and eIOH. The use of these factors to estimate the risk of PIH and eIOH might allow the avoidance or timely treatment of hypotensive episodes during general anaesthesia.


Assuntos
Anestesia Geral/efeitos adversos , Hipotensão/etiologia , Complicações Intraoperatórias/etiologia , Adulto , Idoso , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
6.
Internist (Berl) ; 58(3): 207-217, 2017 Mar.
Artigo em Alemão | MEDLINE | ID: mdl-28184956

RESUMO

Bleeding associated with hemorrhagic shock is often seen in emergency medical services or in the intensive care unit. Identifying the origin of the bleeding and additional disorders helps to determine the degree of the hemorrhagic shock. In order to be effective, the initial therapy until blood products are available needs to be differentiated to be effective in terms of hemodynamic stabilization and coagulation. Crystalloidal and colloidal solutions should be used carefully since those solutions bear a risk within themselves. Treatment of acidosis and hypothermia can further reduce bleeding complications. Early and repeated monitoring of clotting should be performed simultaneously to shock therapy to permit specific treatment and substitution of coagulation factors if needed. Hemorrhagic shock therapy should be continued until bleeding is stopped.


Assuntos
Fatores de Coagulação Sanguínea/uso terapêutico , Hemorragia/etiologia , Hemorragia/terapia , Choque Hemorrágico/terapia , Acidose/terapia , Coagulação Sanguínea , Serviços Médicos de Emergência , Humanos , Hipotermia/terapia , Unidades de Terapia Intensiva
7.
Br J Anaesth ; 118(1): 68-76, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28039243

RESUMO

BACKGROUND: Functional imaging by thoracic electrical impedance tomography (EIT) is a non-invasive approach to continuously assess central stroke volume variation (SVV) for guiding fluid therapy. The early available data were from healthy lungs without injury-related changes in thoracic impedance as a potentially influencing factor. The aim of this study was to evaluate SVV measured by EIT (SVVEIT) against SVV from pulse contour analysis (SVVPC) in an experimental animal model of acute lung injury at different lung volumes. METHODS: We conducted a randomized controlled trial in 30 anaesthetized domestic pigs. SVVEIT was calculated automatically analysing heart-lung interactions in a set of pixels representing the aorta. Each initial analysis was performed automatically and unsupervised using predefined frequency domain algorithms that had not previously been used in the study population. After baseline measurements in normal lung conditions, lung injury was induced either by repeated broncho-alveolar lavage (n=15) or by intravenous administration of oleic acid (n=15) and SVVEIT was remeasured. RESULTS: The protocol was completed in 28 animals. A total of 123 pairs of SVV measurements were acquired. Correlation coefficients (r) between SVVEIT and SVVPC were 0.77 in healthy lungs, 0.84 after broncho-alveolar lavage, and 0.48 after lung injury from oleic acid. CONCLUSIONS: EIT provides automated calculation of a dynamic preload index of fluid responsiveness (SVVEIT) that is non-invasively derived from a central haemodynamic signal. However, alterations in thoracic impedance induced by lung injury influence this method.


Assuntos
Lesão Pulmonar Aguda/fisiopatologia , Impedância Elétrica , Hidratação , Volume Sistólico , Tomografia/métodos , Animais , Respiração com Pressão Positiva , Suínos
8.
Med Klin Intensivmed Notfmed ; 112(4): 326-333, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-26676240

RESUMO

When treating acutely ill patients in the emergency department (ED), the successful management of a variety of medical conditions, such as sepsis, acute kidney injury, and pancreatitis, is highly dependent on the correct assessment and optimization of a patient's intravascular volume status. Therefore, it is crucial that the ED physician knows and uses available means to assess intravascular volume status to adequately guide fluid therapy. This review focuses on techniques for volume status assessment that are available in the ED including basic clinical and laboratory findings, apparatus-based tests such as sonography and chest x-ray, and functional tests to evaluate fluid responsiveness. Furthermore, we provide an outlook on promising innovative, noninvasive technologies that might be used for advanced hemodynamic monitoring in the ED.


Assuntos
Doença Aguda/terapia , Determinação do Volume Sanguíneo/métodos , Volume Sanguíneo/fisiologia , Serviço Hospitalar de Emergência , Hidratação/métodos , Monitorização Hemodinâmica , Humanos , Radiografia Torácica , Ultrassonografia
9.
Anaesth Intensive Care ; 44(3): 340-5, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27246932

RESUMO

The T-Line(®) system (Tensys(®) Medical Inc., San Diego, CA, USA) non-invasively estimates cardiac output (CO) using autocalibrating pulse contour analysis of the radial artery applanation tonometry-derived arterial waveform. We compared T-Line CO measurements (TL-CO) with invasively obtained CO measurements using transpulmonary thermodilution (TDCO) and calibrated pulse contour analysis (PC-CO) in patients after major gastrointestinal surgery. We compared 1) TL-CO versus TD-CO and 2) TL-CO versus PC-CO in 27 patients treated in the intensive care unit (ICU) after major gastrointestinal surgery. For the assessment of TD-CO and PC-CO we used the PiCCO(®) system (Pulsion Medical Systems SE, Feldkirchen, Germany). Per patient, we compared two sets of TD-CO and 30 minutes of PC-CO measurements with the simultaneously recorded TL-CO values using Bland-Altman analysis. The mean of differences (± standard deviation; 95% limits of agreement) between TL-CO and TD-CO was -0.8 (±1.6; -4.0 to +2.3) l/minute with a percentage error of 45%. For TL-CO versus PC-CO, we observed a mean of differences of -0.4 (±1.5; -3.4 to +2.5) l/minute with a percentage error of 43%. In ICU patients after major gastrointestinal surgery, continuous non-invasive CO measurement based on autocalibrating pulse contour analysis of the radial artery applanation tonometry-derived arterial waveform (TL-CO) is feasible in a clinical study setting. However, the agreement of TL-CO with TD-CO and PC-CO observed in our study indicates that further improvements are needed before the technology can be recommended for clinical use in these patients.


Assuntos
Débito Cardíaco/fisiologia , Procedimentos Cirúrgicos do Sistema Digestório/métodos , Manometria/métodos , Artéria Radial/fisiologia , Idoso , Calibragem , Feminino , Frequência Cardíaca/fisiologia , Humanos , Unidades de Terapia Intensiva , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Termodiluição/métodos
12.
Anaesthesist ; 64(7): 494-505, 2015 Jul.
Artigo em Alemão | MEDLINE | ID: mdl-26081011

RESUMO

Goal-directed hemodynamic therapy is becoming increasingly more interesting for anesthesiologists and intensive care physicians. Meta-analyses of studies evaluating perioperative therapy algorithms demonstrated a reduction of postoperative morbidity compared to the previous clinical practices. In this review article the basic concepts of goal-directed hemodynamic therapy and the principles of previously employed therapy algorithms are described and discussed. Furthermore, the questions of how these therapy strategies can be transferred into daily clinical practice and whether these therapeutic approaches might even bear risks for patients are elucidated.


Assuntos
Hidratação/métodos , Hemodinâmica/fisiologia , Algoritmos , Débito Cardíaco , Objetivos , Humanos , Assistência Perioperatória , Complicações Pós-Operatórias/prevenção & controle , Resultado do Tratamento
13.
Br J Anaesth ; 114(4): 562-75, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25596280

RESUMO

The determination of blood flow, i.e. cardiac output, is an integral part of haemodynamic monitoring. This is a review on noninvasive continuous cardiac output monitoring in perioperative and intensive care medicine. We present the underlying principles and validation data of the following technologies: thoracic electrical bioimpedance, thoracic bioreactance, vascular unloading technique, pulse wave transit time, and radial artery applanation tonometry. According to clinical studies, these technologies are capable of providing cardiac output readings noninvasively and continuously. They, therefore, might prove to be innovative tools for the assessment of advanced haemodynamic variables at the bedside. However, for most technologies there are conflicting data regarding the measurement performance in comparison with reference methods for cardiac output assessment. In addition, each of the reviewed technology has its own limitations regarding applicability in the clinical setting. In validation studies comparing cardiac output measurements using these noninvasive technologies in comparison with a criterion standard method, it is crucial to correctly apply statistical methods for the assessment of a technology's accuracy, precision, and trending capability. Uniform definitions for 'clinically acceptable agreement' between innovative noninvasive cardiac output monitoring systems and criterion standard methods are currently missing. Further research must aim to further develop the different technologies for noninvasive continuous cardiac output determination with regard to signal recording, signal processing, and clinical applicability.


Assuntos
Débito Cardíaco , Cuidados Críticos , Monitorização Fisiológica , Assistência Perioperatória , Impedância Elétrica , Humanos , Análise de Onda de Pulso , Artéria Radial/fisiologia
15.
Br J Anaesth ; 112(3): 521-8, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24355832

RESUMO

BACKGROUND: Radial artery applanation tonometry technology can be used for continuous non-invasive measurement of arterial pressure (AP). The purpose of this study was to evaluate this AP monitoring technology in intensive care unit (ICU) patients in comparison with invasive AP monitoring using a radial arterial catheter. METHODS: In 24 ICU patients (German university hospital), AP values were simultaneously recorded on a beat-to-beat basis using radial artery applanation tonometry (T-Line system; Tensys Medical, San Diego, CA, USA) and a radial arterial catheter (contralateral arm). The primary endpoint of the study was to investigate the accuracy and precision of the non-invasively assessed AP measurements with the Bland-Altman method based on averaged 10 beat AP epochs (n=2993 10 beat epochs). RESULTS: For mean AP (MAP), systolic AP (SAP), and diastolic AP (DAP), we observed a bias (±standard deviation of the bias; 95% limits of agreement; percentage error) of +2 mm Hg (±6; -11 to +15 mm Hg; 15%), -3 mm Hg (±15; -33 to +27 mm Hg; 23%), and +5 mm Hg (±7; -9 to +19 mm Hg; 22%), respectively. CONCLUSIONS: In ICU patients, MAP and DAP measurements obtained using radial artery applanation tonometry show clinically acceptable agreement with invasive AP determination with a radial arterial catheter. While the radial artery applanation tonometry technology also allows SAP measurements with high accuracy, its precision for SAP measurements needs to be further improved.


Assuntos
Pressão Arterial/fisiologia , Cuidados Críticos/métodos , Manometria/métodos , Monitorização Fisiológica/métodos , Artéria Radial/fisiologia , Adulto , Idoso , Determinação de Ponto Final , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
16.
Br J Anaesth ; 111(2): 185-90, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23491946

RESUMO

BACKGROUND: The T-Line TL-200pro (TL-200pro) device (Tensys Medical, Inc., San Diego, CA, USA), based on radial artery tonometry, provides an arterial pressure (AP) waveform and beat-to-beat values of systolic arterial pressure (SAP), mean arterial pressure (MAP), and diastolic arterial pressure (DAP). The aim of the study was to evaluate this non-invasive technique for continuous AP monitoring in medical intensive care unit (ICU) patients. METHODS: Arterial pressure measurements obtained using the TL-200pro technology were compared using Bland-Altman analysis with values measured directly from a femoral arterial catheter in 34 ICU patients. RESULTS: Arterial pressure values were analysed and compared in 4502 averaged 10-beat epochs. A bias of +0.72 mm Hg (95% limits of agreement -9.37 to +10.82 mm Hg) was observed for MAP. For SAP and DAP, there was a mean difference of -1.39 mm Hg (95% limits of agreement -18.74 to +15.96 mm Hg) and +4.36 mm Hg (95% limits of agreement -8.66 to +17.38 mm Hg), respectively. The percentage error for MAP, SAP, and DAP was 12%, 14%, and 21%, respectively. CONCLUSIONS: Arterial pressure measurement based on radial artery tonometry using the TL-200pro technology is feasible in medical ICU patients. The TL-200pro system is capable of providing MAP values with high accuracy (low mean difference) and precision (narrow limits of agreement) compared with MAP measured invasively using a femoral arterial catheter. The TL-200pro technology is promising for the measurement of SAP and DAP but further development is necessary to improve accuracy and precision.


Assuntos
Determinação da Pressão Arterial/instrumentação , Monitores de Pressão Arterial , Cuidados Críticos/métodos , Unidades de Terapia Intensiva/estatística & dados numéricos , Monitorização Fisiológica/instrumentação , Artéria Radial/fisiologia , Idoso , Pressão Sanguínea/fisiologia , Determinação da Pressão Arterial/métodos , Feminino , Humanos , Masculino , Manometria/métodos , Pessoa de Meia-Idade , Monitorização Fisiológica/métodos
17.
Eur J Clin Microbiol Infect Dis ; 31(7): 1419-28, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22057419

RESUMO

The purpose of this study was to investigate characteristics of critically ill patients with Stenotrophomonas maltophilia (S. maltophilia) isolated from the respiratory tract, to identify risk factors for S. maltophilia-pneumonia and intensive care unit (ICU) mortality and to analyze antibiotic susceptibility of S. maltophilia. This was a retrospective analysis of 64 medical ICU patients with S. maltophilia in the respiratory tract. Thirty-six patients fulfilled the criteria for diagnosis of pneumonia. A significantly higher lung injury score (LIS) was observed in patients with pneumonia compared to patients with colonization (p=0.010). Independent risk factors for S. maltophilia-pneumonia were higher Sequential Organ Failure Assessment (SOFA) score (p=0.009) and immunosuppression (p=0.014). Patients with S. maltophilia-pneumonia had higher ICU mortality within a 28-day follow-up (p=0.040) and higher hospital mortality (p=0.018) than patients with colonization. The highest antibiotic susceptibility rates were observed to trimethoprim-sulfamethoxazole, tigecycline, and moxifloxacin. Higher SOFA score when S. maltophilia was isolated (p=0.001) and development of renal failure (p=0.021) were independent risk factors for ICU mortality. Higher SOFA score and immunosuppression are independent risk factors for S. maltophilia-pneumonia. Patients with S. maltophilia-pneumonia have a significantly higher ICU mortality within a 28-day follow-up, hospital mortality and LIS compared to patients with S. maltophilia-colonization.


Assuntos
Infecções por Bactérias Gram-Negativas/epidemiologia , Pneumonia Bacteriana/epidemiologia , Sistema Respiratório/microbiologia , Stenotrophomonas maltophilia/isolamento & purificação , Adulto , Idoso , Idoso de 80 Anos ou mais , Antibacterianos/farmacologia , Feminino , Infecções por Bactérias Gram-Negativas/microbiologia , Infecções por Bactérias Gram-Negativas/mortalidade , Infecções por Bactérias Gram-Negativas/patologia , Humanos , Unidades de Terapia Intensiva , Masculino , Testes de Sensibilidade Microbiana , Pessoa de Meia-Idade , Pneumonia Bacteriana/microbiologia , Pneumonia Bacteriana/mortalidade , Pneumonia Bacteriana/patologia , Estudos Retrospectivos , Fatores de Risco , Stenotrophomonas maltophilia/efeitos dos fármacos , Análise de Sobrevida
18.
Dtsch Med Wochenschr ; 135(14): 668-74, 2010 Apr.
Artigo em Alemão | MEDLINE | ID: mdl-20358493

RESUMO

BACKGROUND AND OBJECTIVE: Despite numerous publications on the epidemiology of inflammatory bowel diseases (IBD) there is a lack of systematic investigations on live-threatening complications of IBD and their causes. This study evaluates risk factors, course and outcome in intensive-care patients which were related to complications of IBD. PATIENTS AND METHODS: Among 6071 admissions to the intensive-care unit (ICU) of a gastroenterological department (university hospital with IBD-outpatient unit) between 1.1.1991 and 31.1.2008 36 ICU admissions of 28 patients with IBD were documented and prospectively analysed from 1996 onwards, using a structured questionnaire on causes for ICU admission as well as risk factors regarding death, organ failure and length of ICU stay. RESULTS: ICU admissions of IBD patients mainly resulted from three causes: complications specific to IBD (44 %), including acute flare-up, perforation and electrolyte imbalance, septic complications (22 %) and thromboembolic complications (17 %). Five patients died, all from septic complications related to immunosuppression including candida sepsis, varicella pneumonia during treatment with infliximab, and pneumocystis pneumonia related to treatment with azathioprine. The most important risk factors according to uni- and multivariate analyses were old age on ICU-admission and first diagnosis of IBD, previous surgery related to IBD and Crohn's disease. CONCLUSIONS: Complications of both IBD and immunosuppressive therapy may be live-threatening in patients with IBD. Better characterization of patients with a high probability of improved outcome by immunosuppressive and/or antibody-therapy seems to be preferable to noncritical early use of these drugs.


Assuntos
Colite Ulcerativa/complicações , Doença de Crohn/complicações , Unidades de Terapia Intensiva , Adulto , Idoso , Causas de Morte , Colite Ulcerativa/mortalidade , Colite Ulcerativa/terapia , Doença de Crohn/mortalidade , Doença de Crohn/terapia , Feminino , Alemanha , Mortalidade Hospitalar , Hospitais Universitários , Humanos , Tempo de Internação/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Prognóstico , Recidiva , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento , Adulto Jovem
19.
J Dent Res ; 86(5): 451-6, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-17452567

RESUMO

Ozone has been proposed as an alternative oral antiseptic in dentistry, due to its antimicrobial power reported for gaseous and aqueous forms, the latter showing a high biocompatibility with mammalian cells. New therapeutic strategies for the treatment of periodontal disease and apical periodontitis should consider not only antibacterial effects, but also their influence on the host immune response. Therefore, our aim was to investigate the effect of aqueous ozone on the NF-kappaB system, a paradigm for inflammation-associated signaling/transcription. We showed that NF-kappaB activity in oral cells stimulated with TNF, and in periodontal ligament tissue from root surfaces of periodontally damaged teeth, was inhibited following incubation with ozonized medium. Under this treatment, IkappaBalpha proteolysis, cytokine expression, and kappaB-dependent transcription were prevented. Specific ozonized amino acids were shown to represent major inhibitory components of ozonized medium. In summary, our study establishes a condition under which aqueous ozone exerts inhibitory effects on the NF-kappaB system, suggesting that it has an anti-inflammatory capacity.


Assuntos
NF-kappa B/antagonistas & inibidores , Oxidantes Fotoquímicos/farmacologia , Ozônio/farmacologia , Ativação Transcricional/efeitos dos fármacos , Aminoácidos/farmacologia , Células Cultivadas , Meios de Cultivo Condicionados/farmacologia , Citocinas/antagonistas & inibidores , Células Epiteliais , Fibroblastos , Células HeLa , Humanos , Proteínas I-kappa B/antagonistas & inibidores , Ligamento Periodontal/citologia , Periodontite/metabolismo , Transdução de Sinais/efeitos dos fármacos , Fator de Necrose Tumoral alfa/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA