Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 84
Filtrar
1.
Eye (Lond) ; 38(7): 1333-1341, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38200321

RESUMO

BACKGROUND/OBJECTIVES: Axial length, a key measurement in myopia management, is not accessible in many settings. We aimed to develop and assess machine learning models to estimate the axial length of young myopic eyes. SUBJECTS/METHODS: Linear regression, symbolic regression, gradient boosting and multilayer perceptron models were developed using age, sex, cycloplegic spherical equivalent refraction (SER) and corneal curvature. Training data were from 8135 (28% myopic) children and adolescents from Ireland, Northern Ireland and China. Model performance was tested on an additional 300 myopic individuals using traditional metrics alongside the estimated axial length vs age relationship. Linear regression and receiver operator characteristics (ROC) curves were used for statistical analysis. The contribution of the effective crystalline lens power to error in axial length estimation was calculated to define the latter's physiological limits. RESULTS: Axial length estimation models were applicable across all testing regions (p ≥ 0.96 for training by testing region interaction). The linear regression model performed best based on agreement metrics (mean absolute error [MAE] = 0.31 mm, coefficient of repeatability = 0.79 mm) and a smooth, monotonic estimated axial length vs age relationship. This model was better at identifying high-risk eyes (axial length >98th centile) than SER alone (area under the curve 0.89 vs 0.79, respectively). Without knowing lens power, the calculated limits of axial length estimation were 0.30 mm for MAE and 0.75 mm for coefficient of repeatability. CONCLUSIONS: In myopic eyes, we demonstrated superior axial length estimation with a linear regression model utilising age, sex and refractive metrics and showed its clinical utility as a risk stratification tool.


Assuntos
Comprimento Axial do Olho , Miopia , Refração Ocular , Humanos , Miopia/fisiopatologia , Miopia/diagnóstico , Masculino , Feminino , Comprimento Axial do Olho/patologia , Comprimento Axial do Olho/diagnóstico por imagem , Adolescente , Criança , Refração Ocular/fisiologia , Curva ROC , Biometria/métodos , Adulto Jovem , Cristalino/fisiopatologia , Cristalino/diagnóstico por imagem , Cristalino/patologia , Modelos Lineares , Córnea/patologia , Córnea/diagnóstico por imagem , Córnea/fisiopatologia
2.
Eur J Ophthalmol ; : 11206721231219532, 2023 Dec 12.
Artigo em Inglês | MEDLINE | ID: mdl-38087768

RESUMO

Myopia is becoming increasingly common in young generations all over the world, and it is predicted to become the most common cause of blindness and visual impairment in later life in the near future. Because myopia can cause serious complications and vision loss, it is critical to create and prescribe effective myopia treatment solutions that can help prevent or delay the onset and progression of myopia. The scientific understanding of myopia's causes, genetic background, environmental conditions, and various management techniques, including therapies to prevent or postpone its development and slow its progression, is rapidly expanding. However, some significant information gaps exist on this subject, making it difficult to develop an effective intervention plan. As with the creation of this present algorithm, a compromise is to work on best practices and reach consensus among a wide number of specialists. The quick rise in information regarding myopia management may be difficult for the busy eye care provider, but it necessitates a continuing need to evaluate new research and implement it into daily practice. To assist eye care providers in developing these strategies, an algorithm has been proposed that covers all aspects of myopia mitigation and management. The algorithm aims to provide practical assistance in choosing and developing an effective myopia management strategy tailored to the individual child. It incorporates the latest research findings and covers a wide range of modalities, from primary, secondary, and tertiary myopia prevention to interventions that reduce the progression of myopia.

3.
J Ophthalmol ; 2023: 7961623, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37946723

RESUMO

Purpose: Previous studies have demonstrated an association between melatonin status and both refractive error and axial length in young adult myopes. This study aimed to determine if this relationship extends to a younger adolescent cohort. Methods: Healthy children aged 12-15 years provided morning saliva samples before attending Ulster University (55°N) for cycloplegic autorefraction and axial length measures. Participants completed questionnaires describing recent sleep habits and physical activity. Salivary melatonin was quantified using high-performance liquid chromatography-tandem mass spectrometry. Data collection for all participants occurred over a 1-week period (April 2021). Results: Seventy participants aged 14.3 (95% CI: 14.2-14.5) years were categorised by spherical equivalent refraction [SER] (range: -5.38DS to +1.88DS) into two groups; myopic SER ≤ -0.50DS (n = 22) or nonmyopic -0.50DS < SER ≤ +2.00DS (n = 48). Median morning salivary melatonin levels were 4.52 pg/ml (95% CI: 2.60-6.02) and 4.89 pg/ml (95% CI: 3.18-5.66) for myopic and nonmyopic subjects, respectively, and did not differ significantly between refractive groups (P = 0.91). Melatonin levels were not significantly correlated with SER, axial length, sleep, or activity scores (Spearman's rank, all P > 0.39). Higher levels of physical activity were associated with higher sleep quality (Spearman's rank, ρ = -0.28, P = 0.02). Conclusion: The present study found no significant relationship between morning salivary melatonin levels and refractive error or axial length in young adolescents. This contrasts with outcomes from a previous study of adults with comparable methodology, season of data collection, and geographical location. Prospective studies are needed to understand the discrepancies between adult and childhood findings and evaluate whether melatonin levels in childhood are indicative of an increased risk for future onset of myopia and/or faster axial growth trajectories and myopia progression in established myopes. Future work should opt for a comprehensive dim-light melatonin onset protocol to determine circadian phase.

4.
Ophthalmic Physiol Opt ; 43(5): 985-996, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37340533

RESUMO

PURPOSE: Controversy exists regarding the influence of peripheral visual experience on the onset and progression of childhood myopia. This longitudinal, observational study evaluated the relationship between relative peripheral refraction (RPR) and changes in refractive error and axial length (AL) over 12 months in White children aged 6-7 and 12-13 years with a range of baseline refractive errors. METHODS: Cycloplegic baseline autorefraction at horizontal retinal eccentricities of 0° and ±30° were recorded with the Shin-Nippon NVision-K 5001 while AL was measured using the Zeiss IOLMaster 700. Measurements were repeated after 12 months on a subgroup. Refractive data were transposed into power vectors as mean spherical equivalent (M), J0 and J45 . RPR was calculated by subtracting central from peripheral measurements. Participants were defined as myopic (M ≤ -0.50 D), premyopic (-0.50 D < M ≤ +0.75 D), emmetropic (+0.75 D < M < +2.00 D) or hyperopic (M ≥ +2.00 D). RESULTS: Data were collected from 222 and 245 participants aged 6-7 and 12-13 years, respectively. Myopic eyes demonstrated, on average, more hyperopic RPR. Emmetropes and premyopes displayed emmetropic RPR, and hyperopes showed a myopic RPR. Fifty-six 6- to 7-year-olds and seventy 12- to 13-year-olds contributed 12-month repeated measures. Longitudinal data demonstrated a significant relationship between a more hyperopic RPR in the nasal retina and greater short-term axial elongation in teens with myopia at baseline (ß = 0.69; p = 0.04). Each dioptre of relative peripheral hyperopia in the nasal retina was associated with an additional 0.10 mm (95% CI: 0.02-0.18 mm) annual increase in AL. CONCLUSIONS: Hyperopic RPR in the nasal retina of myopic children is indicative of increased risk for rapid axial elongation and may be a useful metric to support decision-making in myopia management.


Assuntos
Hiperopia , Miopia , Erros de Refração , Adolescente , Criança , Humanos , Miopia/etiologia , Refração Ocular , Erros de Refração/complicações , Retina , População Branca , Estudos Longitudinais
5.
Eye (Lond) ; 37(10): 1958-1965, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36258009

RESUMO

Cerebral Visual Impairment (CVI) is a common condition in the UK. Patients with conditions associated with CVI are frequently seen in paediatric ophthalmology clinics offering eye care professionals an opportunity to identify children proactively. In most cases CVI occurs as part of a neurodevelopmental condition or as a feature of multiple and complex disabilities. However, CVI can also be seen in children with apparently typical development. In some cases, high contrast visual acuity is normal and in other cases severely impaired. As such, identification of CVI requires evaluation of aspects of visual performance beyond high contrast acuity and consideration that visual function of those with CVI may fluctuate. Few paediatric ophthalmologists have received formal training in CVI. The detection and diagnosis of CVI varies across the UK and patients report hugely different experiences. A diagnosis of CVI is made based on professional clinical judgement and it is recognised that individual perspectives and local practice in the specific methodologies of assessment will vary. A systematic review and survey of professionals is underway to attempt to reach agreement on diagnostic criteria. Nonetheless, established pathways and published protocols can offer guidance on how a paediatric ophthalmology service can approach assessment of the child with suspected CVI. The purpose of this paper is to present a summary of research and clinical practice methods for detecting and diagnosing CVI in a paediatric ophthalmology outpatient setting. It represents current understanding of the topic and acknowledges the evolving nature of both practice and the evidence-base. A rapid literature review was undertaken to identify articles relating to clinical investigation of children with CVI. A focus group of QTVI and subject matter experts from sight loss charities was undertaken to address areas which were not covered by the literature review.


Assuntos
Oftalmologia , Transtornos da Visão , Criança , Humanos , Consenso , Transtornos da Visão/diagnóstico , Transtornos da Visão/terapia , Acuidade Visual , Cegueira
6.
Ophthalmic Physiol Opt ; 42(1): 48-58, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34761427

RESUMO

PURPOSE: To evaluate the repeatability and reproducibility of the swept-source optical coherence tomographer Zeiss IOLMaster 700 and compare its outputs with those obtained using partial coherence interferometry (Zeiss IOLMaster v3) in a healthy, paediatric population. METHODS: This is a cross-sectional, observational study. Examiner 1 took two sets of biometric measurements (axial length [AL], mean corneal radius of curvature [Kmean ], anterior chamber depth [ACD] and lens thickness [LT]) using the IOLMaster 700, and one set of measurements (AL, Kmean and ACD) using the IOLMaster v3. Examiner 2 took one full set of measurements using the IOLMaster 700. Mean differences and 95% limits of agreement (LOA) were calculated, and Bland and Altman plots used to explore repeatability and reproducibility of the IOLMaster 700 alongside establishing its agreement with the IOLMaster v3. RESULTS: Mean participant age was 7.52 ± 0.58 years. Repeatability analyses demonstrated small mean differences and narrow 95% LOA for AL (0.001, -0.013 to 0.015 mm), Kmean (0.002, -0.020 to 0.024 mm), ACD (-0.003, -0.031 to 0.024 mm) and LT (0.001, -0.024 to 0.026 mm), respectively. Similarly, small mean differences and narrow 95% LOA established excellent reproducibility (AL 0.001, -0.016 to 0.018 mm; Kmean -0.001, -0.027 to 0.025 mm; ACD -0.010, -0.041 to 0.021 mm; LT 0.002, -0.016 to 0.020 mm). The IOLMaster 700 and IOLMaster v3 demonstrated good agreement with small mean differences and narrow 95% LOA (AL 0.009, -0.034 to 0.052 mm; Kmean 0.016, -0.013 to 0.044 mm; ACD 0.134, 0.055 to 0.212 mm). CONCLUSIONS: When used within a paediatric population, these data demonstrate the IOLMaster 700 to be highly repeatable and reproducible for measures of AL, Kmean , ACD and LT. There is excellent inter-instrument agreement between the IOLMaster 700 and IOLMaster v3 for measures of AL and Kmean . ACD measurements show weaker agreement. These data will be useful when considering reports from population-based studies of refractive error and clinical myopia research.


Assuntos
Câmara Anterior , Comprimento Axial do Olho , Câmara Anterior/diagnóstico por imagem , Comprimento Axial do Olho/anatomia & histologia , Biometria , Criança , Córnea/anatomia & histologia , Estudos Transversais , Humanos , Interferometria , Estudos Prospectivos , Reprodutibilidade dos Testes , Tomografia de Coerência Óptica
7.
Ophthalmic Physiol Opt ; 41(5): 1048-1059, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34387902

RESUMO

PURPOSE: To compare real-world measures of illumination obtained with the Actiwatch-2 and Clouclip-M2 with 'gold standard' photometry measures and to evaluate the ability of Actiwatch-2 to correctly identify photometer-defined conditions: scotopic (≤0.01 lux), mesopic (0.02-3 lux), indoor photopic (>3-1,000 lux) and outdoor photopic (>1,000 lux); and Clouclip to correctly identify photometer-defined conditions within its operating range (>1 lux). Inter-device reliability of Clouclip for illumination and viewing distance measures was also investigated. METHODS: A Hagner-S2 photometer was used as reference. Measures of illumination were obtained from a range of real-world conditions. To investigate inter-device reliability, five Clouclips were simultaneously exposed to varied light conditions and object distances. RESULTS: Strong correlations existed between illumination measured with the photometer and both Actiwatch-2 (ρ = 0.99, p < 0.0001) and Clouclip (ρ = 0.99, p < 0.0001). However, both devices underestimated illumination compared to the photometer; disparity increased with increasing illumination and was greater for Actiwatch-2 than Clouclip measures. Actiwatch-2 successfully categorised illumination level (scotopic, mesopic, indoor and outdoor photopic) in 71.2% of cases. Clouclip successfully categorised illumination levels as scotopic/mesopic (≤3 lux) and indoor and outdoor photopic in 100% of cases. Mean differences and limits of agreement (LOA) were 430.92 ± 1,828.74 and 79.35 ± 407.33 lux, between the photometer and Actiwatch-2 and photometer and Clouclip, respectively. The Intra-class Correlation Coefficients for illumination and viewing distance measured with five Clouclips were 0.85 and 0.96, respectively. CONCLUSION: These data illustrate that different Clouclip devices produce comparable measures of viewing distance and illumination in real-world settings. Both Actiwatch-2 and Clouclip underestimate illumination in the field compared to gold standard photometer measures. The disparity increases at higher levels of illumination and the discrepancy was greater for Actiwatch-2 measures. For researchers interested in categorising light exposure, Clouclip classifies illumination levels >2 lux more accurately than Actiwatch-2 but cannot discriminate between scotopic and low mesopic light.


Assuntos
Visão de Cores , Iluminação , Humanos , Reprodutibilidade dos Testes
9.
Invest Ophthalmol Vis Sci ; 62(4): 6, 2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-33821881

RESUMO

Purpose: This study investigated whether refractive correction improved accommodative function of hyperopic children while engaged in two sustained near activities. Methods: Sustained accommodative function of 63 participants (aged 5-10 years) with varying levels of uncorrected hyperopia (>/= +1.00 D and < + 5.00 D spherical equivalent in the least hyperopic eye) was measured using eccentric infrared photorefraction (PowerRef 3; PlusOptix, Germany). Binocular accommodation measures were recorded while participants engaged in 2 tasks at 25 cm for 15 minutes each: an "active" task (reading small print on an Amazon Kindle), and a "passive" task (watching an animated movie on liquid crystal display [LCD] screen). Participants also underwent a comprehensive visual assessment, including measurement of presenting visual acuity, prism cover test, and stereoacuity. Reading speed was assessed with and without hyperopic correction. Refractive error was determined by cycloplegic retinoscopy. Results: Hyperopic refractive correction significantly improved accuracy of accommodative responses in both task (pairwise comparisons: t = -3.70, P = 0.001, and t = -4.93, P < 0.001 for reading and movie tasks, respectively). Accommodative microfluctuations increased with refractive correction in the reading task (F(1,61) = 25.77, P < 0.001) but decreased in the movie task (F(1,59) = 4.44, P = 0.04). Reading speed also significantly increased with refractive correction (F(1,48) = 66.32, P < 0.001). Conclusions: Correcting low-moderate levels of hyperopia has a positive impact on accommodative performance during sustained near activity in some schoolchildren. For these children, prescribing hyperopic correction may benefit performance in near vision tasks.


Assuntos
Acomodação Ocular/fisiologia , Hiperopia/terapia , Refração Ocular/fisiologia , Visão Binocular/fisiologia , Acuidade Visual , Criança , Pré-Escolar , Emetropia , Feminino , Humanos , Hiperopia/diagnóstico , Hiperopia/fisiopatologia , Masculino , Leitura , Retinoscopia
10.
Eur J Ophthalmol ; 31(3): 853-883, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33673740

RESUMO

The prevalence of myopia is increasing extensively worldwide. The number of people with myopia in 2020 is predicted to be 2.6 billion globally, which is expected to rise up to 4.9 billion by 2050, unless preventive actions and interventions are taken. The number of individuals with high myopia is also increasing substantially and pathological myopia is predicted to become the most common cause of irreversible vision impairment and blindness worldwide and also in Europe. These prevalence estimates indicate the importance of reducing the burden of myopia by means of myopia control interventions to prevent myopia onset and to slow down myopia progression. Due to the urgency of the situation, the European Society of Ophthalmology decided to publish this update of the current information and guidance on management of myopia. The pathogenesis and genetics of myopia are also summarized and epidemiology, risk factors, preventive and treatment options are discussed in details.


Assuntos
Miopia Degenerativa , Oftalmologia , Procedimentos Ortoceratológicos , Progressão da Doença , Humanos , Miopia Degenerativa/epidemiologia , Miopia Degenerativa/prevenção & controle , Prevalência
11.
Ophthalmic Physiol Opt ; 41(2): 224-244, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33368471

RESUMO

PURPOSE: Cerebral visual impairment (CVI) is the leading cause of childhood visual impairment in the developed world. Despite this, there are no agreed clinical guidelines for the investigation and diagnosis of the condition. Before development of such guidelines can commence, it is important to recognise which approaches are currently employed. This systematic review evaluated the literature to identify which methods of assessment are currently used to investigate and diagnose childhood CVI. METHODS: Medline, Embase, CINAHL, Scopus and the Cochrane Library databases were systematically searched in January 2020 using defined search terms. Articles were included if they: (i) were research papers, conference abstracts or research protocols published in peer-reviewed scientific journals, or relevant textbooks; (ii) included a clinical investigation of CVI in children; (iii) provided an explanation or criteria to diagnose CVI and (iv) were specifically investigating cerebral/cortical visual impairment. Methods used to a) assess and b) diagnose CVI were extracted from included articles. 'Assessment scores' were assigned for each method employed by researchers to investigate and diagnose CVI to quantify and compare approaches between articles. A quality grading was also applied to each article. RESULTS: Of 6454 identified articles, 45 met the inclusion criteria. From these, 10 categories of assessment utilised within included articles were identified: (1) Medical history, (2) Vision assessment/ophthalmologic examination, (3) Neuroimaging, (4) Visual behaviour and direct observation, (5) Structured history-taking, (6) Visual perception tests, (7) Ocular movement and posture assessment, (8) Intelligence/IQ assessment, (9) Clinical electrophysiology and (10) Neurodevelopmental tests. In terms of diagnostic criteria, the most commonly reported approach was one of exclusion, i.e., CVI was diagnosed when visual dysfunction could not be attributed to abnormalities detected in the anterior visual pathway. CONCLUSION: There is a lack of common practice in the approaches used by clinicians to investigate and diagnose CVI in children. At present, a 'diagnosis of exclusion' remains the most common means to diagnose CVI. Development of clinical guidelines for assessment and diagnosis are necessary to ensure consistency in the diagnosis of CVI and the timely implementation of support to alleviate the impact of CVI on the child's daily living.


Assuntos
Córtex Cerebral/diagnóstico por imagem , Técnicas de Diagnóstico Oftalmológico , Neuroimagem/métodos , Transtornos da Visão/diagnóstico , Acuidade Visual/fisiologia , Córtex Cerebral/fisiopatologia , Criança , Gerenciamento Clínico , Humanos , Transtornos da Visão/etiologia , Transtornos da Visão/fisiopatologia
12.
Sci Rep ; 10(1): 15189, 2020 09 16.
Artigo em Inglês | MEDLINE | ID: mdl-32938970

RESUMO

This report describes development of spherical equivalent refraction (SER) and axial length (AL) in two population-based cohorts of white, European children. Predictive factors for myopic growth were explored. Participants were aged 6-7- (n = 390) and 12-13-years (n = 657) at baseline. SER and AL were assessed at baseline and 3, 6 and 9 years prospectively. Between 6 and 16 years: latent growth mixture modelling identified four SER classes (Persistent Emmetropes-PEMM, Persistent Moderate Hyperopes-PMHYP, Persistent High Hyperopes-PHHYP and Emerging Myopes-EMYO) as optimal to characterise refractive progression and two classes to characterise AL. Between 12 and 22-years: five SER classes (PHHYP, PMHYP, PEMM, Low Progressing Myopes-LPMYO and High Progressing Myopes-HPMYO) and four AL classes were identified. EMYO had significantly longer baseline AL (≥ 23.19 mm) (OR 2.5, CI 1.05-5.97) and at least one myopic parent (OR 6.28, CI 1.01-38.93). More myopic SER at 6-7 years (≤ + 0.19D) signalled risk for earlier myopia onset by 10-years in comparison to baseline SER of those who became myopic by 13 or 16 years (p ≤ 0.02). SER and AL progressed more slowly in myopes aged 12-22-years (- 0.16D, 0.15 mm) compared to 6-16-years (- 0.41D, 0.30 mm). These growth trajectories and risk criteria allow prediction of abnormal myopigenic growth and constitute an important resource for developing and testing anti-myopia interventions.


Assuntos
Comprimento Axial do Olho , Miopia Degenerativa/diagnóstico , Refração Ocular , Adolescente , Adulto , Idade de Início , Criança , Estudos de Coortes , Europa (Continente)/epidemiologia , Feminino , Humanos , Masculino , Miopia Degenerativa/epidemiologia , Prognóstico , Fatores de Risco , Testes Visuais , População Branca , Adulto Jovem
13.
PLoS One ; 15(9): e0238779, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32915866

RESUMO

OBJECTIVES: To evaluate parent and teacher opinion of the provision of in-school eyecare and jargon-free written reporting of visual status for children in special educational settings. PARTICIPANTS AND METHODS: A nationally-agreed, in-school eyecare framework for children attending special schools which recommends a full eye examination, dispensing of spectacles and provision of a jargon-free written report of visual outcomes to parents and teachers, was provided to 200 children (mean age 10 years, 9 months; 70% male) attending a special school in the UK. The written 'Vision Report' detailed, in lay-language, results from the eye examination and provided practical advice to alleviate the impact of vision difficulties both at home and in the classroom. Following implementation of the framework, parents and teachers completed a feedback questionnaire to determine their opinion of the in-school eye examination and utility of the Vision Report. RESULTS: Parents of 123 participants returned a feedback questionnaire. Eighty-eight participants were represented by the 23 teachers who returned a questionnaire. The in-school eyecare was rated positively for children in special education by 82.4% of parents and 80.9% of teachers. Key benefits included the familiarity of the in-school setting (81.3% of parents and 100% of teachers agree), the convenience of the setting for parents (74.0% of parents and 100% of teachers agree), and the opportunity for teachers to speak directly to eyecare providers regarding a child's visual needs (82.6% of teachers agree). The information provided by the Vision Report was deemed useful day-to-day by 78.3% of parents and 100% of teachers. The majority (80%) of teachers implemented classroom modifications suggested in the report, whereas only 47.9% of parents reported implementation of modifications at home. CONCLUSIONS: Provision of in-school eyecare is valued by parents and teachers of children in special education settings. Jargon-free, written reports of visual status are valued and utilised by parents and teachers. Further support is required to aid parents in implementing vision modifications at home.


Assuntos
Educação Inclusiva/estatística & dados numéricos , Pais , Instituições Acadêmicas/estatística & dados numéricos , Testes Visuais/estatística & dados numéricos , Criança , Documentação , Feminino , Conhecimentos, Atitudes e Prática em Saúde , Humanos , Masculino , Inquéritos e Questionários
14.
Sci Rep ; 10(1): 12179, 2020 07 22.
Artigo em Inglês | MEDLINE | ID: mdl-32699286

RESUMO

This study demonstrates significant differences between the area of complete spatial summation (Ricco's area, RA) in eyes with and without non-pathological, axial myopia. Contrast thresholds were measured for six stimuli (0.01-2.07 deg2) presented at 10º eccentricity in 24 myopic subjects and 20 age-similar non-myopic controls, with RA estimated using iterative two-phase regression analysis. To explore the effects of axial length-induced variations in retinal image size (RIS) on the measurement of RA, refractive error was separately corrected with (i) trial lenses at the anterior focal point (near constant inter-participant RIS in mm), and (ii) contact lenses (RIS changed with axial length). For spectacle corrected measurements, RA was significantly larger in the myopic group, with a significant positive correlation also being observed between RA and measures of co-localised peripheral ocular length. With contact lens correction, there was no significant difference in RA between the groups and no relationship with peripheral ocular length. The results suggest RA changes with axial elongation in myopia to compensate for reduced retinal ganglion cell density. Furthermore, as these changes are only observed when axial length induced variations in RIS are accounted for, they may reflect a functional adaptation of the axially-myopic visual system to an enlarged RIS.


Assuntos
Potenciais de Ação/fisiologia , Comprimento Axial do Olho/fisiologia , Miopia/fisiopatologia , Adolescente , Adulto , Estudos de Casos e Controles , Lentes de Contato , Óculos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estimulação Luminosa , Erros de Refração , Células Ganglionares da Retina/citologia , Células Ganglionares da Retina/fisiologia , Adulto Jovem
15.
Invest Ophthalmol Vis Sci ; 61(8): 45, 2020 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-32729910

RESUMO

Purpose: To evaluate the relationship between refractive error, circadian phase, and melatonin with consideration of prior light exposure, physical activity, and sleep. Methods: Healthy young myopic (spherical equivalent refraction [SER] ≤-0.50DS) and emmetropic adults underwent noncycloplegic autorefraction and axial length (AL) measures. Objective measurements of light exposure, physical activity, and sleep were captured across 7 days by wrist-worn Actiwatch-2 devices. Questionnaires assessed sleep quality and chronotype. Hourly evening saliva sampling during a dim-light melatonin onset (DLMO) protocol evaluated circadian phase, and both morning serum and saliva samples were collected. Liquid chromatography/mass spectrometry quantified melatonin. Results: Subjects (n = 51) were aged 21.4 (interquartile range, 20.1-24.0) years. Melatonin was significantly higher in the myopic group at every evening time point and with both morning serum and saliva sampling (P ≤ 0.001 for all). DLMO-derived circadian phase did not differ between groups (P = 0.98). Multiple linear regression analysis demonstrated significant associations between serum melatonin and SER (B = -.34, ß = -.42, P = 0.001), moderate activity (B = .009, ß = .32, P = 0.01), and mesopic illumination (B = -.007, ß = -.29, P = 0.02), F(3, 46) = 7.23, P < 0.001, R2 = 0.32, R2adjusted = .28. Myopes spent significantly more time exposed to "indoor" photopic illumination (3 to ≤1000 lux; P = 0.05), but "indoor" photopic illumination was not associated with SER, AL, or melatonin, and neither sleep, physical activity, nor any other light exposure metric differed significantly between groups (P > 0.05 for all). Conclusions: While circadian phase is aligned in adult myopes and emmetropes, myopia is associated with both elevated serum and salivary melatonin levels. Prospective studies are required to ascertain whether elevated melatonin levels occur before, during, or after myopia development.


Assuntos
Ritmo Circadiano/fisiologia , Luz , Melatonina , Erros de Refração , Sono/fisiologia , Meio Ambiente , Exercício Físico/fisiologia , Feminino , Humanos , Masculino , Melatonina/análise , Melatonina/sangue , Erros de Refração/metabolismo , Erros de Refração/fisiopatologia , Saliva/metabolismo , Adulto Jovem
16.
Sci Rep ; 10(1): 10031, 2020 06 22.
Artigo em Inglês | MEDLINE | ID: mdl-32572106

RESUMO

Down syndrome (DS) is frequently associated with cataract, but there remains scant information about DS cataract morphology. Supra-nuclear cataracts in DS have been proposed as indicative of beta-amyloid (Aß) aggregation and thus potential biomarkers for Alzheimer's (AD). This study employed anterior segment OCT (AS-OCT) and slit-lamp (SL) photography to image the crystalline lens in DS, compared with adult controls. Lens images were obtained post-dilation. Using MATLAB, AS-OCT images were analysed and lens opacities calculated as pixel intensity and area ratios. SL images were classified using LOCS III. Subjects were n = 28 DS (mean ± SD 24.1 ± 14.3years), and n = 36 controls (54.0 ± 3.4years). For the DS group, AS-OCT imaging revealed the frequent presence of small dot opacities (27 eyes, 50%) in the cortex and nucleus of the lens, covering an area ranging from 0.2-14%. There was no relation with age or visual acuity and these dot opacities (p > 0.5) and they were not present in any control lenses. However, their location and morphology does not coincide with previous reports linking these opacities with Aß accumulation and AD. Four participants (14%) in the DS group had clinically significant age-related cataracts, but there was no evidence of early onset of age-related cataracts in DS.


Assuntos
Câmara Anterior/diagnóstico por imagem , Catarata/etiologia , Síndrome de Down/complicações , Adolescente , Adulto , Câmara Anterior/patologia , Estudos de Casos e Controles , Catarata/diagnóstico por imagem , Catarata/patologia , Criança , Síndrome de Down/patologia , Feminino , Humanos , Cristalino/diagnóstico por imagem , Cristalino/patologia , Masculino , Pessoa de Meia-Idade , Microscopia com Lâmpada de Fenda , Tomografia de Coerência Óptica , Adulto Jovem
18.
Augment Altern Commun ; 36(1): 54-62, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-32248709

RESUMO

Learning to read and spell is an important but difficult achievement for children who have complex communication needs. Given that assessment is a vital part of any intervention program, one major barrier is the lack of reliable and valid assessments for this population. This study evaluated the reliability and validity of Dynamic Assessment of the Alphabetic Principle (DAAP), which does not require spoken responses. For this study, 27 preschool and school-aged children with typical development completed the DAAP and other standard measures of phonemic awareness and early literacy. Results indicated the DAAP had high internal consistency and strong correlations among its subtests, indicating high reliability. Moreover, performance on the DAAP had high correlations with standard measures of phonemic awareness and early literacy, providing evidence of its validity. Consequently, the DAAP represents one approach to fill the important need for assessments of early literacy that do not require speech responses.


Assuntos
Alfabetização , Fonética , Criança , Pré-Escolar , Auxiliares de Comunicação para Pessoas com Deficiência , Transtornos da Comunicação/reabilitação , Feminino , Voluntários Saudáveis , Humanos , Testes de Linguagem , Masculino , Leitura , Reprodutibilidade dos Testes
19.
Optom Vis Sci ; 97(3): 198-206, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-32168243

RESUMO

SIGNIFICANCE: Pupillometry protocols evaluating rod/cone- and melanopsin-driven responses often use mydriatics to ensure maximal stimulus exposure; however, retinal effects of mydriatics are not fully understood. We demonstrate that dilation with either atropine or phenylephrine results in similar enhancements of rod/cone- and melanopsin-driven pupil responses. PURPOSE: The purposes of this study were to compare the effects of atropine, a muscarinic antagonist, and phenylephrine, an adrenergic agonist, on consensual pupil responses and to assess the repeatability of pupil metrics without mydriasis. METHODS: Right eye pupil responses of 20 adults aged 21 to 42 years were recorded before and 45 minutes after instillation of 0.5% atropine or 2.5% phenylephrine in the left eye. Stimuli were presented to the left eye and included six alternating 1-second 651-nm "red" and 456-nm "blue" flashes. Metrics included baseline pupil diameter, maximal constriction, 6- and 30-second post-illumination pupil responses, and early (0 to 10 seconds) and late (10 to 30 seconds) areas under the curve. RESULTS: Dilation of the stimulated eye with either mydriatic significantly increased the 6-second post-illumination pupil response and early and late areas under the curve for blue stimuli, and early area under the curve for red stimuli (P < .05 for all). Melanopsin-driven post-illumination pupil responses, achieved with either phenylephrine or atropine, did not significantly differ from each other (P > .05 for all). Without mydriasis, intersession intraclass correlation coefficients for pupil metrics were 0.63 and 0.50 (6- and 30-second post-illumination pupil responses, respectively) and 0.78 and 0.44 (early and late areas under the curve, respectively) for blue stimuli, with no significant difference between sessions (P > .05 for all). CONCLUSIONS: Dilation with phenylephrine or atropine resulted in similar enhancements of the rod/cone- and melanopsin-driven pupil responses, despite differing mechanisms. Early pupil metrics without mydriasis demonstrated moderate to good intersession repeatability.


Assuntos
Atropina/farmacologia , Midriáticos/farmacologia , Fenilefrina/farmacologia , Pupila/efeitos dos fármacos , Opsinas de Bastonetes/metabolismo , Administração Oftálmica , Agonistas de Receptores Adrenérgicos alfa 1/farmacologia , Adulto , Feminino , Humanos , Masculino , Antagonistas Muscarínicos/farmacologia , Soluções Oftálmicas , Estimulação Luminosa , Células Fotorreceptoras de Vertebrados/efeitos dos fármacos , Células Fotorreceptoras de Vertebrados/metabolismo , Reflexo Pupilar/fisiologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA