Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Stud Health Technol Inform ; 295: 75-78, 2022 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-35773810

RESUMO

Log data, captured during use of mobile health (mHealth) applications by health providers, can play an important role in informing nature of user engagement with the application. The log data can also be employed in understanding health provider work patterns and performance. However, given that these logs are raw data, they require robust cleaning and curation if accurate conclusions are to be derived from analyzing them. This paper describes a systematic data cleaning process for mHealth-derived logs based on Broeck's framework, which involves iterative screening, diagnosis, and treatment of the log data. For this study, log data from the demonstrative mUzima mHealth application are used. The employed data cleaning process uncovered data inconsistencies, duplicate logs, missing data within logs that required imputation, among other issues. After the data cleaning process, only 39,229 log records out of the initial 91,432 usage logs (42.9%) could be included in the final dataset suitable for analyses of health provider work patterns. This work highlights the significance of having a systematic data cleaning approach for log data to derive useful information on health provider work patterns and performance.


Assuntos
Avaliação de Desempenho Profissional/métodos , Pessoal de Saúde/normas , Aplicativos Móveis , Telemedicina , Coleta de Dados/normas , Avaliação de Desempenho Profissional/normas , Avaliação de Desempenho Profissional/tendências
2.
J Med Internet Res ; 23(12): e28958, 2021 12 22.
Artigo em Inglês | MEDLINE | ID: mdl-34941557

RESUMO

BACKGROUND: Unique patient identification remains a challenge in many health care settings in low- and middle-income countries (LMICs). Without national-level unique identifiers for whole populations, countries rely on demographic-based approaches that have proven suboptimal. Affordable biometrics-based approaches, implemented with consideration of contextual ethical, legal, and social implications, have the potential to address this challenge and improve patient safety and reporting accuracy. However, limited studies exist to evaluate the actual performance of biometric approaches and perceptions of these systems in LMICs. OBJECTIVE: The aim of this study is to evaluate the performance and acceptability of fingerprint technology for unique patient matching and identification in the LMIC setting of Kenya. METHODS: In this cross-sectional study conducted at an HIV care and treatment facility in Western Kenya, an open source fingerprint application was integrated within an implementation of the Open Medical Record System, an open source electronic medical record system (EMRS) that is nationally endorsed and deployed for HIV care in Kenya and in more than 40 other countries; hence, it has potential to translate the findings across multiple countries. Participants aged >18 years were conveniently sampled and enrolled into the study. Participants' left thumbprints were captured and later used to retrieve and match records. The technology's performance was evaluated using standard measures: sensitivity, false acceptance rate, false rejection rate, and failure to enroll rate. The Wald test was used to compare the accuracy of the technology with the probabilistic patient-matching technique of the EMRS. Time to retrieval and matching of records were compared using the independent samples 2-tailed t test. A survey was administered to evaluate patient acceptance and satisfaction with use of the technology. RESULTS: In all, 300 participants were enrolled; their mean age was 36.3 (SD 12.2) years, and 58% (174/300) were women. The relevant values for the technology's performance were sensitivity 89.3%, false acceptance rate 0%, false rejection rate 11%, and failure to enroll rate 2.3%. The technology's mean record retrieval speed was 3.2 (SD 1.1) seconds versus 9.5 (SD 1.9) seconds with demographic-based record retrieval in the EMRS (P<.001). The survey results revealed that 96.3% (289/300) of the participants were comfortable with the technology and 90.3% (271/300) were willing to use it. Participants who had previously used fingerprint biometric systems for identification were estimated to have more than thrice increased odds of accepting the technology (odds ratio 3.57, 95% CI 1.0-11.92). CONCLUSIONS: Fingerprint technology performed very well in identifying adult patients in an LMIC setting. Patients reported a high level of satisfaction and acceptance. Serious considerations need to be given to the use of fingerprint technology for patient identification in LMICs, but this has to be done with strong consideration of ethical, legal, and social implications as well as security issues.


Assuntos
Infecções por HIV , Tecnologia , Adulto , Estudos Transversais , Feminino , Infecções por HIV/terapia , Humanos , Quênia , Inquéritos e Questionários
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA