Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
Diagnostics (Basel) ; 13(4)2023 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-36832101

RESUMO

The indications for the treatment of patients with known atrial fibrillation (AF) undergoing percutaneous coronary intervention (PCI) are clear, while less is available about the management of new-onset AF (NOAF) during ST-segment elevation myocardial infarction (STEMI). The aim of this study is to evaluate mortality and clinical outcome of this high-risk subgroup of patients. We analyzed 1455 consecutive patients undergoing PCI for STEMI. NOAF was detected in 102 subjects, 62.7% males, with a mean age of 74.8 ± 10.6 years. The mean ejection fraction (EF) was 43.5 ± 12.1% and the mean atrial volume was increased (58 ± 20.9 mL). NOAF occurred mainly in the peri-acute phase and had a very variable duration (8.1 ± 12.5 min). During hospitalization, all the patients were treated with enoxaparin, but only 21.6% of them were discharged with long term oral anticoagulation. The majority of patients had a CHA2DS2-VASc score >2 and a HAS-BLED score of 2 or 3. The in-hospital mortality was 14.2%, while the 1-year mortality was 17.2% and long-term mortality 32.1% (median follow-up 1820 days). We identified age as an independent predictor of mortality both at short- and long-term follow-ups, while EF was the only independent predictor for in-hospital mortality and arrhythmia duration for 1-year mortality. At the 1-year follow-up, we recorded three ischemic strokes and no bleeding complications.

2.
J Clin Med ; 11(19)2022 Oct 06.
Artigo em Inglês | MEDLINE | ID: mdl-36233765

RESUMO

The use of increasingly complex cardiac implantable electronic devices (CIEDs) has increased exponentially in recent years. One of the most serious complications in terms of mortality, morbidity and financial burden is represented by infections involving these devices. They may affect only the generator pocket or be generalised with lead-related endocarditis. Modifiable and non-modifiable risk factors have been identified and they can be associated with patient or procedure characteristics or with the type of CIED. Pocket and systemic infections require a precise evaluation and a specialised treatment which in most cases involves the removal of all the components of the device and a personalised antimicrobial therapy. CIED retention is usually limited to cases where infection is unlikely or is limited to the skin incision site. Optimal re-implantation timing depends on the type of infection and on the results of microbiological tests. Preventive strategies, in the end, include antibiotic prophylaxis before CIED implantation, the possibility to use antibacterial envelopes and the prevention of hematomas. The aim of this review is to investigate the pathogenesis, stratification, diagnostic tools and management of CIED infections.

3.
J Electrocardiol ; 69: 119-123, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34695778

RESUMO

INTRODUCTION: Many Authors already described automatic activity arising from accessory pathways, but the underlying mechanism has not been clarified yet. They may be due to embryogenetic features of myocardium or may be related to specific excitability during radiofrequency ablation. CASE: Our report shows that ventricular accelerated rhythm may transiently arise from the ventricular edge of a common myocardium made accessory pathway right after the ablation. No further action were required in our experience, since the phenomenon self extinguished in approximately hour. CONCLUSIONS: If this manifestation represents the effect of thermal injury or if it is a real intrinsic automaticity is not fully documented and may need further reporting and investigation.


Assuntos
Feixe Acessório Atrioventricular , Ablação por Cateter , Complexos Ventriculares Prematuros , Síndrome de Wolff-Parkinson-White , Feixe Acessório Atrioventricular/cirurgia , Eletrocardiografia , Sistema de Condução Cardíaco/cirurgia , Humanos , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/cirurgia , Síndrome de Wolff-Parkinson-White/diagnóstico , Síndrome de Wolff-Parkinson-White/cirurgia
4.
Front Genet ; 10: 547, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31231430

RESUMO

In this case report, we characterize a novel inherited frameshift mutation c.4700_4701del (p.Phe1567Cysfs*221) in a single copy of the SCN5A gene and its association with Brugada syndrome (BrS). The proband experienced a life-threatening ventricular arrhythmia successfully treated with DC-shock and he also suffered from supraventricular tachycardia. Ajmaline test confirmed the BrS diagnosis. No other mutation nor low frequency variants in the other 23 analyzed genes were detected. The same mutation was found in the father and sister, who were both diagnosed with BrS. We hypothesize that this mutation could be responsible for BrS and potentially linked to supraventricular tachycardias. Further studies are needed to confirm this observation and to assess the clinical relevance of this mutation, in terms of risk-stratification.

5.
Europace ; 21(8): 1193-1202, 2019 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-31056645

RESUMO

AIMS: Clinical outcomes after radiofrequency catheter ablation (RFCA) remain suboptimal in the treatment of non-paroxysmal atrial fibrillation (AF). Electrophysiological mapping may improve understanding of the underlying mechanisms. To describe the arrhythmia substrate in patients with persistent (Pers) and long-standing persistent (LSPers) AF, undergoing RFCA, using an integrated mechanism mapping technique. METHODS AND RESULTS: Patients underwent high-density electroanatomical mapping before and after catheter ablation. Integrated maps characterized electrogram (EGM) cycle length (CL) in regions with repetitive-regular (RR) activations, stable wavefront propagation, fragmentation, and peak-to-peak bipolar voltage. Among 83 patients (72% male, 60 ± 11 years old), RR activations were identified in 376 regions (mean CL 180 ± 31 ms). PersAF patients (n = 43) showed more RR sites per patient (5.3 ± 2.4 vs. 3.7 ± 2.1, P = 0.002) with faster CL (166 ± 29 vs. 190 ± 29 ms; P < 0.001) and smaller surface area of fragmented EGMs (15 ± 14% vs. 27 ± 17%, P < 0.001) compared with LSPersAF. The post-ablation map in 50 patients remaining in AF, documented reduction of the RR activities per patient (1.5 ± 0.7 vs. 3.7 ± 1.4, P < 0.001) and area of fragmentation (22 ± 17% vs. 8 ± 9%, P < 0.001). Atrial fibrillation termination during ablation occurred at RR sites (0.48 ± 0.24 mV; 170.5 ± 20.2 ms CL) in 31/33 patients (94%). At the latest follow-up, arrhythmia freedom was higher among patients receiving ablation >75% of RR sites (Q4 82.6%, Q3 63.1%, Q2 35.1%, and Q1 0%; P < 0.001). CONCLUSION: The integrated mapping technique allowed characterization of multiple arrhythmic substrates in non-paroxysmal AF patients. This technique might serve as tool for a substrate-targeted ablation approach.


Assuntos
Fibrilação Atrial , Mapeamento Potencial de Superfície Corporal , Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Mapeamento Potencial de Superfície Corporal/instrumentação , Mapeamento Potencial de Superfície Corporal/métodos , Eletrofisiologia Cardíaca/métodos , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Técnicas Eletrofisiológicas Cardíacas/métodos , Fenômenos Eletrofisiológicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Assistência Perioperatória/métodos , Reprodutibilidade dos Testes , Resultado do Tratamento
6.
Front Genet ; 10: 50, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30828344

RESUMO

In this case series, we report for the first time a family in which the inherited nonsense mutation [c. 3946C > T (p.Arg1316*)] in the SCN5A gene segregates in association with Brugada syndrome (BrS). Moreover, we also report, for the first time, the frameshift mutation [c.7686delG (p.Ile2563fsX40)] in the NF1 gene, as well as its association with type 1 neurofibromatosis (NF1), characterized by pigmentary lesions (café au lait spots, Lisch nodules, freckling) and cutaneous neurofibromas. Both of these mutations and associated phenotypes were discovered in the same family. This genetic association may identify a subset of patients at higher risk of sudden cardiac death who require the appropriate electrophysiological evaluation. This case series highlights the importance of genetic testing not only to molecularly confirm the pathology but also to identify asymptomatic family members who need clinical examinations and preventive interventions, as well as to advise about the possibility of avoiding recurrence risk with medically assisted reproduction.

7.
J Interv Card Electrophysiol ; 54(2): 141-149, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30483980

RESUMO

PURPOSE: Cardiac resynchronization therapy (CRT) with multipoint left ventricular (LV) pacing (MultiPoint™ Pacing [MPP]) improves long-term LV reverse remodeling, though questions persist about how to program LV pacing vectors and delays. We evaluated if an empirical method of programming MPP vectors and delays between pacing pulses improved CRT response similar to pressure-volume loop (PVL) optimized MPP programming. METHODS: Patients undergoing CRT implant (Quadra Assura MP™ CRT-D and Quartet™ LV lead) received MPP with programmed settings optimized either by PVL measurements at implant (PVL-OPT group) or empirically determined by maximizing the spatial separation between the two cathodes and minimal delays between the three ventricular pacing pulses (MAX-SEP group). CRT response was prospectively defined as a reduction in end-systolic volume (ESV) of ≥ 15% relative to baseline at 6 months as determined by a blinded observer. RESULTS: Patient characteristics at baseline (NYHA II-III, ejection fraction [EF] 27 ± 6%, QRS 151 ± 17 ms) were not significantly different between the PVL-OPT (n = 27) and MAX-SEP (n = 26) groups. During the follow-up period, there were no differences in the number of patients requiring reprogramming due to phrenic nerve stimulation or a high threshold for PVL-OPT vs. MAX-SEP (5/27 [19%] vs. 7/26 [27%], p = 0.53). After 6 months, ESV reduction, EF increase, and CRT response rate (RR) were similar for PVL-OPT vs. MAX-SEP (ESV - 20 ± 11 vs. - 22 ± 11%, p = 0.59; EF + 10 ± 4 vs. + 9 ± 7%, p = 0.53; RR 20/27 [74%] vs. 21/26 [81%], p = 0.74), while fewer patients in the PVL-OPT group experienced NYHA class reduction ≥ 2 (4/27 [15%] vs.15/26 [58%], p = 0.002). CONCLUSIONS: Both evaluated methods of MPP programming resulted in similar CRT outcomes. Empirical MPP programming by maximum spatial separation of LV cathodes may be an effective, simple, and non-invasive alternative to pressure-volume optimization.


Assuntos
Estimulação Cardíaca Artificial/métodos , Ecocardiografia/métodos , Insuficiência Cardíaca/terapia , Ventrículos do Coração/diagnóstico por imagem , Remodelação Ventricular/fisiologia , Idoso , Terapia de Ressincronização Cardíaca/métodos , Estudos de Coortes , Feminino , Insuficiência Cardíaca/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos , Medição de Risco , Volume Sistólico/fisiologia , Fatores de Tempo , Resultado do Tratamento
9.
Pacing Clin Electrophysiol ; 41(2): 106-113, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29222865

RESUMO

BACKGROUND: Multipoint left ventricular (LV) pacing (MultiPoint™ Pacing [MPP], Abbott, Sylmar, CA, USA) improves the response rate to cardiac resynchronization therapy (CRT). We evaluated the feasibility of noninvasive radial artery tonometry (RAT) to characterize arterial pressure morphology changes (pre-ejection period [PEP] and ejection duration [ED]) between conventional CRT and MPP pacing interventions. METHODS: Patients with a MPP-enabled CRT device (Quadra Assura MP™, Abbott) underwent noninvasive RAT assessment (SphygmoCor CVMS, AtCor Medical Inc., Itasca, IL, USA) at 3-6 months after implantation. A pacing protocol was performed in a randomized order including one optimized conventional biventricular CRT (CONV) configuration using the distal electrode and five MPP configurations. The PEP, ED, and PEP/ED ratio were determined for each intervention from the RAT pressure waveform and electrocardiogram. RESULTS: Pressure waveforms were successfully recorded in 19 patients (89% male, QRS 147 ± 16 ms, 63% ischemic). In 17/19 (89%) patients, at least one MPP intervention resulted in improved PEP, ED, and PEP/ED compared to CONV. The MPP intervention with greatest separation of LV cathodes and minimum intra-LV delay significantly improved PEP (mean PEP -15 ± 33% vs -8 ± 32% [CONV], P = 0.04) and ED (mean ED +8 ± 8% [MPP] vs +4 ± 7% [CONV], P = 0.02), and PEP/ED (-0.07 ± 0.14 [MPP] vs -0.04 ± 0.13 [CONV], P = 0.02) compared with CONV. CONCLUSIONS: Noninvasive RAT efficiently characterizes changes in PEP and ED between CONV and MPP interventions. MPP configurations using the widest separation among LV cathodes and minimum intra-LV delay may significantly improve RAT-derived parameters as compared to conventional CRT.


Assuntos
Hemodinâmica/fisiologia , Manometria/métodos , Marca-Passo Artificial , Artéria Radial/fisiologia , Idoso , Dispositivos de Terapia de Ressincronização Cardíaca , Ecocardiografia , Eletrocardiografia , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Humanos , Masculino
10.
J Cardiovasc Med (Hagerstown) ; 18(11): 920-921, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28937581

RESUMO

: A huge thrombus, developing after percutaneous left atrial appendage occlusion, has been successfully treated with dabigatran and aspirin as combination therapy.Although novel oral anticoagulants alone may be effective in thrombus dissolution, the association of an antiplatelet drug may safely enhance this process.


Assuntos
Apêndice Atrial/cirurgia , Fibrilação Atrial/terapia , Dispositivo para Oclusão Septal/efeitos adversos , Acidente Vascular Cerebral/prevenção & controle , Trombose/terapia , Idoso , Anticoagulantes/uso terapêutico , Aspirina/uso terapêutico , Dabigatrana , Ecocardiografia Tridimensional , Humanos , Masculino , Trombose/etiologia , Resultado do Tratamento
11.
Circ Arrhythm Electrophysiol ; 10(5): e005053, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28500178

RESUMO

BACKGROUND: There is emerging evidence that localization and elimination of abnormal electric activity in the epicardial right ventricular outflow tract may be beneficial in patients with Brugada syndrome. METHODS AND RESULTS: A total of 135 symptomatic Brugada syndrome patients having implantable cardiac defibrillator were enrolled: 63 (group 1) having documented ventricular tachycardia (VT)/ventricular fibrillation (VF) and Brugada syndrome-related symptoms, and 72 (group 2) having inducible VT/VF without ECG documentation at the time of symptoms. About 27 patients of group 1 experienced multiple implantable cardiac defibrillator shocks for recurrent VT/VF episodes. Three-dimensional maps before and after ajmaline determined the arrhythmogenic electrophysiological substrate (AES) as characterized by prolonged fragmented ventricular potentials. Primary end point was identification and elimination of AES leading to ECG pattern normalization and VT/VF noninducibility. Extensive areas of AES were found in the right ventricle epicardium, which were wider in group 1 (P=0.007). AES increased after ajmaline in both groups (P<0.001) and was larger in men (P=0.008). The increase of type-1 ST-segment elevation correlated with AES expansion (r=0.682, P<0.001). Radiofrequency ablation eliminated AES leading to ECG normalization and VT/VF noninducibility in all patients. During a median follow-up of 10 months, the ECG remained normal even after ajmaline in all except 2 patients who underwent a repeated effective procedure for recurrent VF. CONCLUSIONS: In Brugada syndrome, AES is commonly located in the right ventricle epicardium and ajmaline exposes its extent and distribution, which is correlated with the degree of coved ST-elevation. AES elimination by radiofrequency ablation results in ECG normalization and VT/VF noninducibility. Substrate-based ablation is effective in potentially eliminating the arrhythmic consequences of this genetic disease. CLINICAL TRIAL REGISTRATION: URL: https://clinicaltrials.gov. Unique identifier: NCT02641431.


Assuntos
Síndrome de Brugada/cirurgia , Ablação por Cateter , Taquicardia Ventricular/prevenção & controle , Fibrilação Ventricular/prevenção & controle , Potenciais de Ação , Adolescente , Adulto , Idoso , Ajmalina/administração & dosagem , Antiarrítmicos/administração & dosagem , Síndrome de Brugada/complicações , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/fisiopatologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/fisiopatologia , Resultado do Tratamento , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/etiologia , Fibrilação Ventricular/fisiopatologia , Adulto Jovem
12.
Europace ; 19(7): 1101-1108, 2017 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-27702865

RESUMO

AIMS: Continuous rhythm monitoring is valuable for adequate atrial fibrillation (AF) management in the clinical setting. Subcutaneous leadless implantable cardiac monitors (ICMs) yield an improved AF detection, overcoming the intrinsic limitations of the currently available external recording systems, thus resulting in a more accurate patient treatment. The study purpose was to assess the detection performance of a novel three-vector ICM device equipped with a dedicated AF algorithm. METHODS AND RESULTS: Sixty-six patients (86.4% males; mean age 60.4 ± 9.4 years) at risk to present AF episodes, having undergone the novel ICM implant (BioMonitor, Biotronik SE&Co. KG, Berlin, Germany), were enrolled. External 48-h ECG Holter was performed 4 weeks after the device implantation. The automatic ICM AF classification was compared with the manual Holter arrhythmia recordings. Of the overall study population, 63/66 (95.5%) had analysable Holter data, 39/63 (62%) showed at least one true AF episode. All these patients had at least one AF episode stored in the ICM. On Holter monitoring, 24/63 (38%) patients did not show AF episodes, in 16 of them (16/24, 67%), the ICM confirmed the absence of AF. The AF detection sensitivity and positive predictive value for episodes' analysis were 95.4 and 76.3%, respectively. CONCLUSION: Continuous monitoring using this novel device, equipped with a dedicated detection algorithm, yields an accurate and reliable detection of AF episodes. The ICM is a promising tool for tailoring individual AF patient management. Further long-term prospective studies are necessary to confirm these encouraging results.


Assuntos
Fibrilação Atrial/diagnóstico , Eletrocardiografia/instrumentação , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca , Tecnologia de Sensoriamento Remoto/instrumentação , Telemetria/instrumentação , Potenciais de Ação , Idoso , Algoritmos , Fibrilação Atrial/fisiopatologia , Eletrocardiografia Ambulatorial , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Processamento de Sinais Assistido por Computador , Fatores de Tempo
14.
Int J Cardiol ; 183: 267-73, 2015 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-25725201

RESUMO

Syncope is a significant source of cardiovascular-related morbidity yet the etiology is frequently obscure and the identification of patients at highest risk is challenging. Adenosine (AD) and adenosine triphosphate (ATP) administrations have been suggested as potentially useful non-invasive tools in the diagnostic workup of patients with neurally-mediated or bradycardia-related syncope. It has been postulated that both compounds by modulating the autonomic innervation in the heart and exerting negative chronotropic and dromotropic effects in the conduction system, may unmask the mechanism of syncope. However, the clinical implications derived from the efficacy of both tests in the investigation of syncope remain unclear mainly due to inconclusive and occasionally contradictory results of published studies. This review article summarizes recent and past information in the use of ATP and AD in the investigation of syncope with emphasis on clinical trials. We present the current level of evidence for the use of these agents in clinical practice, identify areas where further research is warranted and highlight the future perspectives of these agents as complements to an accurate risk-stratification of patients with syncope.


Assuntos
Trifosfato de Adenosina/administração & dosagem , Adenosina/administração & dosagem , Síncope/diagnóstico , Síncope/terapia , Adenosina/metabolismo , Trifosfato de Adenosina/metabolismo , Bradicardia/induzido quimicamente , Sistema de Condução Cardíaco/efeitos dos fármacos , Sistema de Condução Cardíaco/fisiologia , Frequência Cardíaca/efeitos dos fármacos , Humanos , Fatores de Risco , Síncope/metabolismo , Síncope/fisiopatologia
15.
Heart Rhythm ; 12(6): 1250-8, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25678057

RESUMO

BACKGROUND: Cardiac resynchronization therapy (CRT) with multipoint left ventricular (LV) pacing (MultiPoint™ Pacing [MPP], St. Jude Medical) improves acute LV function and LV reverse remodeling at 3 months. OBJECTIVE: The purpose of this study was to test the hypothesis that MPP can also improve LV function at 12 months. METHODS: Consecutive patients receiving a CRT implant (Unify Quadra MP™ or Quadra Assura MP™ CRT-D and Quartet™ LV lead, St. Jude Medical) were randomized to receive pressure-volume (PV) loop optimized biventricular pacing with either conventional cardiac resynchronization therapy (CONV) or MPP. CRT response was defined by a reduction in end-systolic volume (ESV) ≥15% relative to BASELINE as determined by a blinded observer and alive status. RESULTS: Forty-four patients (New York Heart Association class III, ejection fraction [EF] 29% ± 6%, QRS 152 ± 17 ms) were enrolled and randomized to either CONV (N = 22) or MPP (N = 22). During the observation period, 2 patients died of noncardiac causes and 2 patients were lost to follow-up. After 12 months, 12 of 21 patients (57%) in the CONV group and 16 of 21 patients (76%) in the MPP group were classified as CRT responders (P = .33). ESV reduction and EF increase relative to BASELINE were significantly greater with MPP than with CONV (ESV: median -25%, interquartile range [IQR] [-39% to -20%] vs median -18%, IQR [-25% to -2%], P = .03; EF: median +15%, IQR [8% to 20%] vs median +5%, IQR [-1% to 8%], P <.001). CONCLUSION: Sustaining the trend observed 3 months postimplant, PV loop-guided multipoint LV pacing resulted in greater LV reverse remodeling and increased LV function at 12 months compared to PV loop-guided conventional CRT.


Assuntos
Estimulação Cardíaca Artificial/métodos , Terapia de Ressincronização Cardíaca/métodos , Idoso , Ecocardiografia , Feminino , Seguimentos , Ventrículos do Coração , Humanos , Masculino , Função Ventricular Esquerda/fisiologia
16.
J Cardiovasc Electrophysiol ; 26(1): 58-63, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25109276

RESUMO

INTRODUCTION: Cardiac resynchronization therapy (CRT) with multipoint left ventricular (LV) pacing in a single coronary sinus branch improves acute LV function. We hypothesized that multipoint pacing (MPP) can improve midterm echocardiographic and clinical response compared with conventional CRT. METHODS AND RESULTS: Consecutive patients receiving a CRT implant (Unify Quadra MP™ or Quadra Assura MP™ CRT-D and Quartet™ LV lead, St. Jude Medical, Sylmar, CA, USA) were randomized to receive biventricular (BiV) pacing with either conventional LV pacing (CONV group) or MPP (MPP group). For each patient, an optimal pacing configuration for the assigned pacing mode was programmed based on intraoperative pressure-volume (PV) loop measurements. A clinical evaluation and transthoracic echocardiogram were performed before implant (BASELINE) and at 3 months postimplant and analyzed by a blinded observer. A reduction in end-systolic volume (ESV) of ≥15% relative to BASELINE was prospectively defined as response to CRT. Forty-four patients (NYHA Class III, EF 29 ± 6%, QRS duration 152 ± 17 milliseconds) were enrolled and randomized. One patient in the MPP group was lost to follow-up and excluded from further analysis. After 3 months, 11 of 22 (50%) CONV patients and 16 of 21 (76%) MPP patients were classified as responders. ESV reduction, EF increase, and NYHA class reduction relative to BASELINE were significantly greater in the MPP group than in the CONV group (ESV: -21.0 ± 13.9 vs. -12.6 ± 11.1%, P = 0.03; EF: +9.8 ± 5.1 vs. +2.0 ± 7.8 percentage points, P < 0.001; ΔNYHA: -1.05 ± 0.22 vs. -0.72 ± 0.46 functional classes, P = 0.006). CONCLUSION: PV loop optimized BiV pacing with MPP resulted in an improved rate of response to CRT.


Assuntos
Estimulação Cardíaca Artificial/métodos , Terapia de Ressincronização Cardíaca , Seio Coronário/fisiopatologia , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Ventrículos do Coração/fisiopatologia , Função Ventricular Esquerda , Idoso , Dispositivos de Terapia de Ressincronização Cardíaca , Desenho de Equipamento , Feminino , Insuficiência Cardíaca/fisiopatologia , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial , Recuperação de Função Fisiológica , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia , Pressão Ventricular
17.
Circulation ; 130(10): 811-9, 2014 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-25052405

RESUMO

BACKGROUND: The management of Wolff-Parkinson-White is based on the distinction between asymptomatic and symptomatic presentations, but evidence is limited in the asymptomatic population. METHODS AND RESULTS: The Wolff-Parkinson-White registry was an 8-year prospective study of either symptomatic or asymptomatic Wolff-Parkinson-White patients referred to our Arrhythmology Department for evaluation or ablation. Inclusion criteria were a baseline electrophysiological testing with or without radiofrequency catheter ablation (RFA). Primary end points were the percentage of patients who experienced ventricular fibrillation (VF) or potentially malignant arrhythmias and risk factors. Among 2169 enrolled patients, 1001 (550 asymptomatic) did not undergo RFA (no-RFA group) and 1168 (206 asymptomatic) underwent ablation (RFA group). There were no differences in clinical and electrophysiological characteristics between the 2 groups except for symptoms. In the no-RFA group, VF occurred in 1.5% of patients, virtually exclusively (13 of 15) in children (median age, 11 years), and was associated with a short accessory pathway antegrade refractory period (P<0.001) and atrioventricular reentrant tachycardia initiating atrial fibrillation (P<0.001) but not symptoms. In the RFA group, ablation was successful in 98.5%, and after RFA, no patients developed malignant arrhythmias or VF over the 8-year follow-up. Untreated patients were more likely to experience malignant arrhythmias and VF (log-rank P<0.001). Time-dependent receiver-operating characteristic curves for predicting VF identified an optimal anterograde effective refractory period of the accessory pathway cutoff of 240 milliseconds. CONCLUSIONS: The prognosis of the Wolff-Parkinson-White syndrome essentially depends on intrinsic electrophysiological properties of AP rather than on symptoms. RFA performed during the same procedure after electrophysiological testing is of benefit in improving the long-term outcomes.


Assuntos
Feixe Acessório Atrioventricular/fisiopatologia , Ablação por Cateter , Síndrome de Wolff-Parkinson-White/fisiopatologia , Síndrome de Wolff-Parkinson-White/cirurgia , Adolescente , Adulto , Arritmias Cardíacas/epidemiologia , Criança , Feminino , Seguimentos , Humanos , Masculino , Estudos Prospectivos , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Taxa de Sobrevida , Resultado do Tratamento , Fibrilação Ventricular/epidemiologia , Síndrome de Wolff-Parkinson-White/mortalidade , Adulto Jovem
18.
Heart Rhythm ; 11(3): 394-401, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24291411

RESUMO

BACKGROUND: Conventional cardiac resynchronization therapy (CRT) improves acute cardiac hemodynamics. OBJECTIVE: To investigate if CRT with multipoint left ventricular (LV) pacing in a single coronary sinus branch (MultiPoint Pacing [MPP], St Jude Medical, Sylmar, CA) can offer further hemodynamic benefits to patients. METHODS: Forty-four consecutive patients (80% men, New York Heart Association III, end-systolic volume 180 ± 77 mL, ejection fraction 27% ± 6%, and QRS duration 152 ± 17 ms) receiving a CRT device implant (Unify Quadra MP or Quadra Assura MP and Quartet LV lead, St Jude Medical) underwent intraoperative assessment of LV hemodynamics by using a pressure-volume loop system (Inca, CD Leycom). A pacing protocol was performed, including 9 biventricular pacing interventions with conventional CRT (CONV) using distal and proximal LV electrodes and various MPP configurations. Each pacing intervention was performed twice in randomized order with right ventricular pacing (BASELINE) repeated after every intervention. RESULTS: Evaluable recordings were obtained in 42 patients. Relative to BASELINE, the best MPP intervention significantly increased the rate of pressure change (dP/dtmax; 15.9% ± 10.0% vs 13.5% ± 8.8%; P < .001), stroke work (27.2% ± 42.5% vs 19.4% ± 32.2%; P = .018), stroke volume (10.4% ± 22.5% vs 4.1% ± 13.1%; P = .003), and ejection fraction (10.5% ± 20.9% vs 5.3% ± 13.2%; P = .003) as compared with the best CONV intervention. Moreover, the best MPP intervention improved acute diastolic function, significantly decreasing -dP/dtmin (-13.5% ± 10.2% vs -10.6% ± 6.8%; P = .011), relaxation time constant (-7.5% ± 9.0% vs -4.8% ± 7.2%; P = .012), and end-diastolic pressure (-18.2% ± 22.4% vs -8.7% ± 21.4%; P < .001) as compared with the best CONV intervention. CONCLUSIONS: CRT with MPP can significantly improve acute LV hemodynamic parameters assessed with pressure-volume loop measurements as compared with CONV.


Assuntos
Estimulação Cardíaca Artificial/métodos , Insuficiência Cardíaca/terapia , Marca-Passo Artificial , Idoso , Feminino , Insuficiência Cardíaca/fisiopatologia , Ventrículos do Coração , Hemodinâmica , Humanos , Masculino , Resultado do Tratamento
19.
Ann Ital Chir ; 84(4): 455-8, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23917491

RESUMO

AIM: The aim of the study was to evaluate the surgical approach to intramyocardial (i.m.) injection of Bone Marrow Stem Cells (BMSCs) in a pre-clinical model and its complications. MATERIAL OF STUDY: In New Zealand rabbits an ischemia reperfusion injury lasting 20 min was induced by temporary ligation of anterior descending coronary artery during cardiac surgical procedure. Homologous BMSCs were isolated from the posterior iliac crest, cultured and re-suspended for injection. BMSC were injected at the peri-infarcted area and side effects were evaluated. A control group with myocardial infarction was treated with i.m. injections of saline, to evaluate possible side effects of injection. Comparison of ventricular premature contractions (VPC), ventricular tachycardia and ventricular fibrillation were recorded during surgery and after 7 and 21 days. RESULTS: Seven rabbits developed intractable ventricular fibrillation during the experimental protocol, three during coronary ligation but before cell injections and four following i.m. injections. At day 7, hourly PVC were more frequent in the groups of animals that received i.m. injections of BMSCs (132 ± 19 beats) compared to saline injections. (54 ± 14). CONCLUSIONS: Intramyocardial injections of BMSCs induced an electrical instability as shown by a high number of PVC as compared with intramyocardial injections of saline.


Assuntos
Transplante de Medula Óssea , Procedimentos Cirúrgicos Cardíacos , Transplante de Células-Tronco , Animais , Transplante de Medula Óssea/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Modelos Animais de Doenças , Feminino , Injeções , Masculino , Modelos Animais , Coelhos , Transplante de Células-Tronco/efeitos adversos
20.
Ann Ital Chir ; 84(6): 631-6, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23340165

RESUMO

AIM: Analyze the results of an early experience in day-case LC (laparoscopic cholecystectomy) in a single laparoscopic unit, in terms of clinical outcome, unexpected admissions, readmissions, patients satisfaction. MATERIALS AND METHODS: During three years, 200 consecutive patients underwent LC. Emergency procedures (32pts) and patients scheduled for cholecystectomy plus other surgical procedures (21pts) were excluded. Thus, 147 patients underwent elective LC and 43 were scheduled for DSLC (day-surgery laparoscopic cholecystectomy). RESULTS: Six patients (13,9%) were considered not eligible for a same day discharge and admitted to the inpatients ward for overnight observation. The re-admission rate was 2,3% and 41 patients (95.3%) were completely satisfied. DISCUSSION: Patients satisfaction was complete in 95.3% of cases, related to a correct preoperative information and the reduction in hospital costs amounted approximately to 41%. Despite the evidence of feasibility and safety of the daycase procedure, the Italian cultural background is nowadays inadequate for a clean acceptance of the DSLC. The provision of adequate staff education and training prior to full DSLC introduction is mandatory to the success of this organizational model. CONCLUSIONS: LC can be performed safely in an outpatient setting if there's a careful education of patients and the surgical and anesthesiologist team is well-trained. Besides, good results can be achieved considering inclusion criteria. For the admission to be kept to a minimum, postoperative pain and nausea management has to be carefully planned such as discharge criteria evaluated. For selected patients, day-case LC is feasible and safe and can provide a reduction in hospital costs.


Assuntos
Procedimentos Cirúrgicos Ambulatórios , Colecistectomia Laparoscópica , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA