Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 77
Filtrar
1.
J Clin Med ; 13(18)2024 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-39336891

RESUMO

Background: We aimed to compare the procedural efficacy and long-term clinical results of a totally contrast-free Transcatheter Aortic Valve Implantation (TAVI) procedure (i.e., contrast dye was not used for either the pre-procedural assessment or during the procedure) to those of standard practice in patients with severe renal dysfunction. Methods: All consecutive patients with a glomerular filtration rate (GFR) ≤ 35 mL/min and severe aortic stenosis who were treated with transfemoral TAVI at our Institution were included in the registry. The zero-contrast patients underwent carbon dioxide angiography and a non-contrast CT scan for assessment of vascular access suitability, and aortic annulus sizing was performed by a TEE, and the procedural guidance was fluoroscopic and echocardiographic. Procedural outcomes were evaluated, and clinical long-term follow-up was performed for all included patients. Results: A total of 44 patients (median age, 85 (IQR, 80.75-87.00)) were included in the zero-contrast group (TEE guidance and general anesthesia in 37 (84%) patients), while 63 patients were included in the standard practice arm (82 ± 78 mL of contrast dye used). Procedural success was obtained in 100% of cases. There were no differences in procedural outcomes, including final mean aortic gradients (5.5 (IQR, 5.0-10.0) mmHg in the zero-contrast group vs. 6.0 (IQR, 5.0-10.0) mmHg in the standard practice group) and rate of at least a moderate paravalvular leak (0% vs. 1.6% in the zero-contrast and standard practice groups, respectively; p = 0.31). No differences in AKI during the hospital stay were observed. Over a median follow-up of 3.3 years, there was a significantly lower rate of AKI (1.2% vs. 25.9%, p < 0.001) and rehospitalizations (1.6% vs. 35.5%, p < 0.00) in standard practice group. Conclusions: We showed for the first time the feasibility and efficacy of a totally contrast-free strategy compared to standard practice in TAVI patients with severe renal dysfunction. Besides achieving comparable procedural results, the zero-contrast strategy showed a better long-term clinical outcome in reducing hospital readmissions for kidney function deterioration.

2.
Microorganisms ; 12(7)2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-39065089

RESUMO

BACKGROUND: The benefits of mitral repair versus replacement for endocarditis are inconclusive. This study compares outcomes of patients with infective endocarditis undergoing mitral valve repair versus replacement and investigates the impact of microbial etiology. METHODS: All 251 patients undergoing mitral valve surgery for active endocarditis between 2010 and 2023 were enrolled, 180 (71.7%) replacement and 71 (28.3%) repair. To adjust for imbalances, inverse probability of treatment weighting was applied and 187 patients were obtained. RESULTS: The analysis between groups, following the application of inverse probability of treatment weighting, showed no statistically significant differences across all considered outcomes. Early and late death was observed respectively in 6 (8.5%) and 11 (15.5%) patients in the repair group versus 24 (13.3%) and 45 (25.0%) in the replacement group without statistical significance (p = 0.221 and p = 0.446). Relapse occurred in six patients (8.5%) in the repair group after a median time of 4.0 months and in six (3.3%) in the replacement after 6.9 months (p = 0.071). CONCLUSIONS: Surgical strategy in mitral endocarditis has no effect on major postoperative complications, mortality, or medium/long-term survival. Staphylococcus aureus and Coagulase-negative Staphylococci represent a risk for early mortality and relapse. However, mitral valve repair for endocarditis can be pursued when it ensures the complete eradication of all infected tissue, particularly in cases caused by Streptococcus infection, in young patients, and after a minimum of 18 days of antibiotic therapy.

3.
Int J Mol Sci ; 25(12)2024 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-38928127

RESUMO

Valvular disease is a complex pathological condition that impacts countless individuals around the globe. Due to limited treatments, it is crucial to understand its mechanisms to identify new targets. Valve disease may result in pulmonary venous hypertension, which is linked to compromised functioning of the alveolar and capillary membranes and hindered gas exchange. Nonetheless, the correlation between surfactant proteins (SPs) and valve disease remains unexplored. A total of 44 patients were enrolled in this study, with 36 undergoing aortic valve replacement and 8 needing a second aortic valve substitution due to bioprosthetic valve degeneration. Ten healthy subjects were also included. The results showed that patients who underwent both the first valve replacement and the second surgery had significantly higher levels of immature SP-B (proSP-B) compared to control subjects. The levels of the extra-lung collectin SP-D were higher in patients who needed a second surgery due to bioprosthetic valve degeneration, while SP-A levels remained unchanged. The research also showed that there was no reciprocal relationship between inflammation and SP-D as the levels of inflammatory mediators did not differ between groups. The present study demonstrates that circulating proSP-B serves as a reliable marker of alveolar-capillary membrane damage in patients with valvular heart disease.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Calcinose , Proteína B Associada a Surfactante Pulmonar , Humanos , Estenose da Valva Aórtica/sangue , Estenose da Valva Aórtica/cirurgia , Masculino , Feminino , Proteína B Associada a Surfactante Pulmonar/sangue , Proteína B Associada a Surfactante Pulmonar/metabolismo , Idoso , Calcinose/sangue , Valva Aórtica/cirurgia , Valva Aórtica/patologia , Pessoa de Meia-Idade , Biomarcadores/sangue , Estudos de Casos e Controles
4.
Eur J Cardiothorac Surg ; 65(2)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38321206

RESUMO

Iatrogenic injuries to the circumflex coronary artery during mitral valve surgery are probably underestimated (reported rates of 0.3-1.8%). This complication arises from the artery's close proximity to the mitral annulus, particularly at the anterolateral commissure. The study aimed to assess this risk in a patient group prone to such injury. The surgical procedure utilized a minimally invasive approach and indocyanine green-based fluorescence imaging. This technique allows a real-time visualization of the circumflex artery, aiding precise placement of annular sutures and minimizing the risk of injury. The method, applied in 6 patients, integrates preoperative assessments with intraoperative fluorescence imaging, ensuring accurate arterial depiction and preventing iatrogenic damage. The study highlights the safety and efficacy of fluorescence imaging, especially in identifying vessel anomalies, indicating potential applications in various cardiac procedures.


Assuntos
Vasos Coronários , Insuficiência da Valva Mitral , Humanos , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Verde de Indocianina , Estudos de Viabilidade , Insuficiência da Valva Mitral/cirurgia , Doença Iatrogênica
5.
G Ital Cardiol (Rome) ; 25(3): 157-161, 2024 Mar.
Artigo em Italiano | MEDLINE | ID: mdl-38410896

RESUMO

Surgical mitral valve repair (SMVR) is performed with various techniques that involve the implantation of non-biological material, such as the prolene of the suture threads, the polytetrafluoroethylene of the neo-chordae or the prosthetic ring for the remodeling of the valve annulus, whose exposure to the bloodstream is capable of triggering the blood coagulation cascade and consequently the development of thrombotic/thromboembolic events. The indications of the literature on the use of antithrombotic drugs after SMVR are weak and not univocal given the absence of randomized data and the availability of only small observational case series, which are generally contaminated by the lack of homogeneity of the populations examined. Indeed in these studies, patients not only undergoing SMVR, but also transcatheter repair of the mitral valve or surgical implantation of a biological valve prosthesis (not only in the mitral position) are included. In addition, the indication for antithrombotic therapy, and in particular anticoagulation, is often conditioned by the concomitant presence of atrial fibrillation that either preexists or develops postoperatively. In this review, the current evidence regarding antithrombotic therapy in patients undergoing SMVR, both in the presence or absence of atrial fibrillation, is summarized and updated treatment algorithms are proposed.


Assuntos
Fibrilação Atrial , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Valva Mitral/cirurgia , Fibrinolíticos , Implante de Prótese de Valva Cardíaca/métodos , Fibrilação Atrial/cirurgia , Resultado do Tratamento , Insuficiência da Valva Mitral/etiologia
6.
J Clin Med ; 13(2)2024 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-38256672

RESUMO

BACKGROUND: Bradyarrhythmia requiring pacemaker implantation among patients undergoing valve surgery may occur even after several years, with unclear predictors. Our aim was to investigate the incidence of pacemaker implantation at different follow-up times and identify associated predictors. METHODS: We conducted a retrospective study evaluating 1046 consecutive patients who underwent valve surgery at the Cardiac Surgery Division of Bologna University Hospital from 2005 to 2010. RESULTS: During 10 ± 4 years of follow-up, 11.4% of these patients required pacemaker implantation. Interventions on both atrioventricular valves independently predicted long-term pacemaker implantation (SHR 2.1, 95% CI 1.2-3.8, p = 0.014). Preoperative atrioventricular conduction disease strongly predicted long-term atrioventricular block, with right bundle branch block as the major predictor (SHR 7.0, 95% CI 3.9-12.4, p < 0.001), followed by left bundle branch block (SHR 4.9, 95% CI 2.4-10.1, p < 0.001), and left anterior fascicular block (SHR 3.9, 95% CI 1.8-8.3, p < 0.001). CONCLUSION: Patients undergoing valvular surgery have a continuing risk of atrioventricular block late after surgery until the 12-month follow-up, which was clearly superior to the rate of atrioventricular block observed at long-term. Pre-operative atrioventricular conduction disease and combined surgery on both atrioventricular valves are strong predictors of atrioventricular block requiring pacemaker implantation.

7.
Biomedicines ; 12(1)2024 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-38275404

RESUMO

BACKGROUND: Despite advanced diagnosis and treatment, infective endocarditis (IE) is a potentially life-threatening condition. The impact of COVID-19 on the diagnosis and outcome of the surgical treatment of IE is uncertain. The aim of this study was to analyze the incidence, characteristics, and outcomes of surgically treated IE before and after the COVID-19 pandemic. METHODS: This study retrospectively analyzed the data of 535 patients who underwent valve surgical procedures for IE between January 2010 and December 2022 in a single cardiac surgery center. Patients were divided into two groups depending on the date of their operation: before (n = 393) and after (n = 142) COVID-19 onset. In order to balance the groups, inverse probability of treatment weighting (IPTW) calculated from the propensity score (PS) was applied. Weighted univariate logistic regressions were reported for outcomes; weights were derived from IPTW. Interrupted time series analysis (ITSA) according to Linden's method was used to evaluate the changes in the manifestation of IE after 11 March 2020. RESULTS: Patients from the post-COVID-19 cohort (after 11 March 2020) had a greater number of comorbidities such as diabetes (29.6% vs. 16.3% p = 0.001), hypertension (71.1% vs. 59.5% p = 0.015), and preoperative kidney injury requiring dialysis (9.2% vs. 2.5% p = 0.002), but the median additive and logistic EuroSCORE were not statistically different. In the post-COVID-19 group, we observed a greater prevalence of Staphylococcus aureus-related endocarditis (24.5% vs. 15.4% p = 0.026), a consequent reduction in Staphylococcus non aureus-related endocarditis (12.2% vs. 20.1% p = 0.048), and a decrease in aortic valve replacements (43.0% vs. 53.9%), while the number of mitral valve replacements and repair was greater (21.1% vs. 15.0% and 6.3% vs. 4.3%, respectively). No differences were found in the two groups concerning early death, death, or relapse at 1 year after surgery. Data obtained by multivariable analysis identified preoperative renal dysfunction requiring dialysis as the only common risk factor for early mortality via stratifying by time periods in analysis. CONCLUSIONS: The incidence of surgically treated IE significantly increases after the COVID-19 pandemic with a higher incidence of mitral valve involvement with respect to the aortic valve. Although a delay in surgical timing occurred during the COVID-19 pandemic, data in terms of mortality and outcomes were largely unaffected.

8.
Eur J Cardiothorac Surg ; 65(2)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38212996

RESUMO

OBJECTIVES: In the last decades, 4 different scores for the prediction of mortality following surgery for type A acute aortic dissection (TAAD) were proposed. We aimed to validate these scores in a large external multicentre cohort. METHODS: We retrospectively analysed patients who underwent surgery for TAAD between 2000 and 2020. Patients were enrolled from 10 centres from 2 European countries. Outcomes were the early (30-day and/or in-hospital) and 1-year mortality. Discrimination, calibration and observed/expected (O/E) ratio were evaluated. RESULTS: A total of 1895 patients (31.7% females, mean age 63.72 ± 12.8 years) were included in the study. Thirty-day mortality and in-hospital mortality were 21.7% (n = 412) and 22.5% (n = 427) respectively. The German Registry of Acute Aortic Dissection Type A (GERAADA) score shows to have the best discrimination [area under the curve (AUC) 0.671 and 0.672] in predicting as well the early and the 1-year mortality, followed by the International Registry of Acute Aortic Dissection (IRAD) model 1 (AUC 0.658 and 0.672), the Centofanti (AUC 0.645 and 0.66) and the UK aortic score (AUC 0.549 and 0.563). According to Hosmer-Lemeshow and Brier tests, the IRAD model I and GERAADA, respectively, were well calibrated for the early mortality, while the GERAADA and Centofanti for the 1-year mortality. The O/E analysis showed a marked underestimation for patients labelled as low-risk for UK aortic score and IRAD model I for both outcomes. CONCLUSIONS: The GERAADA score showed the best performance in comparison with other scores. However, none of them achieved together a fair discrimination and a good calibration for predicting either the early or the 1-year mortality.


Assuntos
Dissecção Aórtica , Azidas , Desoxiglucose/análogos & derivados , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Estudos Retrospectivos , Dissecção Aórtica/cirurgia , Mortalidade Hospitalar , Europa (Continente) , Sistema de Registros , Fatores de Risco , Resultado do Tratamento
10.
Bioengineering (Basel) ; 10(12)2023 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-38136021

RESUMO

In elderly patients undergoing cardiac surgery, extracorporeal circulation affects the incidence of post-operative delirium and cognitive impairment with an impact on quality of life and mortality. In this study, a new oxygenator system (RemoweLL 2) was tested against a conventional system to assess its efficacy in reducing the onset of postoperative delirium and cognitive dysfunction and the levels of serum inflammatory markers. A total of 154 patients (>65 y.o.) undergoing cardiopulmonary bypass (CPB) were enrolled and randomly assigned to oxygenator RemoweLL 2 (n = 81) or to gold standard device Inspire (n = 73) between September 2019 and March 2022. The aims of the study were to assess the incidence of delirium and the cognitive decline by neuropsychiatric tests and the MoCa test intra-hospital and at 6 months after CPB. Inflammation biomarkers in both groups were also evaluated. Before the CPB, the experimental groups were comparable for all variables. After CPB, the incidence of severe post-operative delirium showed a better trend (p = 0.093) in patients assigned to RemoweLL 2 (16.0%) versus Inspire (26.0%). Differences in enolase levels (p = 0.049), white blood cells (p = 0.006), and neutrophils (p = 0.003) in favor of RemoweLL 2 were also found. The use of novel and better construction technologies in CPB oxygenator devices results in measurable better neurocognitive and neurological outcomes in the elderly population undergoing CPB.

11.
Biomolecules ; 13(12)2023 11 28.
Artigo em Inglês | MEDLINE | ID: mdl-38136584

RESUMO

Recent evidence indicates that reactive oxygen species play an important causative role in the onset and progression of valvular diseases. Here, we analyzed the oxidative modifications of albumin (HSA) occurring on Cysteine 34 and the antioxidant capacity of the serum in 44 patients with severe aortic stenosis (36 patients underwent aortic valve replacement and 8 underwent a second aortic valve substitution due to a degenerated bioprosthetic valve), and in 10 healthy donors (controls). Before surgical intervention, patients showed an increase in the oxidized form of albumin (HSA-Cys), a decrease in the native reduced form (HSA-SH), and a significant reduction in serum free sulfhydryl groups and in the total serum antioxidant activity. Patients undergoing a second valve replacement showed levels of HSA-Cys, free sulfhydryl groups, and total antioxidant activity similar to those of controls. In vitro incubation of whole blood with aspirin (ASA) significantly increased the free sulfhydryl groups, suggesting that the in vivo treatment with ASA may contribute to reducing oxidative stress. We also found that N-acetylcysteine and its amide derivative were able to regenerate HSA-SH. In conclusion, the systemic oxidative stress reflected by high levels of HSA-Cys is increased in patients with aortic valve stenosis. Thiol-disulfide breaking agents regenerate HSA-SH, thus paving the way to the use these compounds to mitigate the oxidative stress occurring in the disease.


Assuntos
Antioxidantes , Estenose da Valva Aórtica , Humanos , Albumina Sérica , Estresse Oxidativo , Acetilcisteína/farmacologia , Compostos de Sulfidrila
12.
Biomedicines ; 11(11)2023 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-38001989

RESUMO

BACKGROUND: Nowadays, one of the main goals of aortic valve surgery is to reduce the biological impact, mortality, and complications. It is well-known that long operative times in terms of the extracorporeal circulation, but above all, of the aortic cross-clamp time (ACC), represent a risk factor for mortality in patients undergoing cardiac surgery. In order to shorten the aortic cross-clamp time, many technological improvements, such as sutureless prostheses, have been introduced, but their actual effectiveness has not been proven yet. The aim of this study was to assess the 30-day outcomes of patients undergoing aortic valve replacement surgery, focusing on the ACC length. METHODS: All 3139 patients undergoing aortic valve replacement between January 2013 and July 2022 at our institution were enrolled. The data were retrospectively collected and the baseline characteristics and intraoperative variables were recorded. In order to adjust the results according to the differences in the baseline characteristics, propensity score matching was performed and four groups of 351 patients were obtained based on the first, second, third, and fourth quartile of the ACC time. RESULTS: The patient population included 132 redo surgeries (9.4%) and 61 cases of active endocarditis (4.3%), with an overall median EuroSCORE II of 1.8 (IQR 1.2-3.1). An increase across the groups was observed in terms of the acute kidney failure (p < 0.001) incidence, the number of blood transfusions (p = 0.022), prolonged hospital stays (p < 0.001), the and respiratory failure (p < 0.001) incidence. A p of < 0.1 was found for the 30-day mortality (p = 0.079). The predictors of an early 30-day mortality were standard full sternotomy (OR 2.48, 95% CI 1.14-5.40, p = 0.022), EuroSCORE II (OR 1.10, 95% CI 1.05-1.16, p < 0.001), and a trend for a longer ACC time (Q4 vs. Q1: OR 2.62, 95% CI 0.89-7.68, p = 0.080). CONCLUSIONS: Shortening the operative times resulted in marked improvements of the patients' outcomes. The combined use of minimally invasive approaches and sutureless aortic valve prostheses allows for a lower 30-day events rate. New technologies should be assessed to obtain the best results with the least risk.

13.
Eur J Cardiothorac Surg ; 64(4)2023 10 04.
Artigo em Inglês | MEDLINE | ID: mdl-37812223

RESUMO

OBJECTIVES: The aim of this study was to examine the incidence and predictors of stroke after minimally invasive mitral valve surgery (mini-MVS) and to assess the role of preoperative CT scan on surgical management and neurological outcomes in the large cohort of Mini-Mitral International Registry. METHODS: Clinical, operative and in-hospital outcomes in patients undergoing mini-MVS between 2015 and 2021 were collected. Univariable and multivariable analyses were used to identify predictors of stroke. Finally, the impact of preoperative CT scan on surgical management and neurological outcomes was assessed. RESULTS: Data from 7343 patients were collected. The incidence of stroke was 1.3% (n = 95/7343). Stroke was associated with higher in-hospital mortality (11.6% vs 1.5%, P < 0.001) and longer intubation time, ICU and hospital stay (median 26 vs 7 h, 120 vs 24 h and 14 vs 8 days, respectively). On multivariable analysis, age (odds ratio 1.039, 95% confidence interval 1.019-1.060, P < 0.001) and mitral valve replacement (odds ratio 2.167, 95% confidence interval 1.401-3.354, P < 0.001) emerged as independent predictors of stroke. Preoperative CT scan was made in 31.1% of cases. These patients had a higher risk profile and EuroSCORE II (median 1.58 vs 1.1, P < 0.001). CT scan influenced the choice of cannulation site, being ascending aorta (18.5% vs 0.5%, P < 0.001) more frequent in the CT group and femoral artery more frequent in the no CT group (97.8% vs 79.7%, P < 0.001). No difference was found in the incidence of postoperative stroke (CT group 1.5, no CT group 1.4%, P = 0.7). CONCLUSIONS: Mini-MVS is associated with a low incidence of stroke, but when it occurs it has an ominous impact on mortality. Preoperative CT scan affected surgical cannulation strategy but did not led to improved neurological outcomes.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca , Acidente Vascular Cerebral , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Fatores de Risco , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Esternotomia/efeitos adversos , Procedimentos Cirúrgicos Minimamente Invasivos/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/efeitos adversos
14.
Innovations (Phila) ; 18(3): 274-275, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37309866

RESUMO

Currently, minimally invasive cardiac surgery (MICS) has been developing and has been largely approved for mitral valve surgery. The more development of MICS, the more the entire surgical setup needs to be appropriate. We developed a homemade tool for mitral annular sizing that is simple and fits the mini surgical access. It is a plastic-based foldable paper that can be easily inserted through the minithoracotomy, using a surgical forceps.


Assuntos
Implante de Prótese de Valva Cardíaca , Anuloplastia da Valva Mitral , Insuficiência da Valva Mitral , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Anuloplastia da Valva Mitral/métodos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Toracotomia/métodos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/métodos
15.
Eur J Cardiothorac Surg ; 63(6)2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-37052525

RESUMO

OBJECTIVES: Minimally invasive access has become the preferred choice in mitral and/or tricuspid valve surgery. Reported outcomes are at least similar to classic sternotomy although aortic cross-clamp times are usually longer. METHODS: We analysed the largest registry of mitral and/or tricuspid valve surgery patients (mini-mitral international registry (MMIR)) for the relationship between aortic cross-clamp times, mortality and other outcomes. From 2015 to 2021, 7513 consecutive patients underwent mini-mitral and/or tricuspid valve surgery in 17 international Heart-Valve-Centres. Data were collected according to Mitral Valve Academic Research Consortium (MVARC) definitions and 6878 patients with 1 cross-clamp period were analysed. Uni- and multivariable regression analyses were used to assess outcomes in relation to aortic cross-clamp times. RESULTS: Median age was 65 years (57% male). Median EuroSCORE II was 1.3% (Inpatient Quality Reporting (IQR): 0.80-2.63). Minimally invasive access was either by direct vision (28%), video-assisted (41%) or totally endoscopic/robotic (31%). Femoral cannulation was used in 93%. Three quarters were repairs with 17% additional tricuspid valve surgery and 19% Atrial Fibrillation (AF)-ablation. Cardiopulmonary bypass and cross-clamp times were 135 min (IQR: 107-173) and 85 min (IQR: 64-111), respectively. Postoperative events were death (1.6%), stroke (1.2%), bleeding requiring revision (6%), low cardiac output syndrome (3.5%) and acute kidney injury (6.2%, mainly stage I). Statistical analyses identified significant associations between cross-clamp time and mortality, low cardiac output syndrome and acute kidney injury (all P < 0.001). Age, low ejection fraction and emergent surgery were risk factors, but variables of 'increased complexity' (redo, endocarditis, concomitant procedures) were not. CONCLUSIONS: Aortic cross-clamp time is associated with mortality as well as postoperatively impaired cardiac and renal function. Thus, implementing measures to reduce cross-clamp time may improve outcomes.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca , Humanos , Masculino , Idoso , Feminino , Baixo Débito Cardíaco/etiologia , Baixo Débito Cardíaco/cirurgia , Valva Mitral/cirurgia , Procedimentos Cirúrgicos Cardíacos/métodos , Aorta/cirurgia , Esternotomia/métodos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Resultado do Tratamento , Toracotomia , Estudos Retrospectivos , Implante de Prótese de Valva Cardíaca/métodos
16.
J Clin Med ; 12(6)2023 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-36983179

RESUMO

BACKGROUND: Studies reporting on the outcome of 90-year-old patients undergoing cardiac surgery are scant in literature; and currently, those regarding the implementation of trans-catheter techniques number even fewer. METHODS: We compared patients aged >89 years operated on between 1998 and 2008 at 8 Italian cardiac surgery centers, with patients of the same age operated on between 2009 and 2021. All of the patients were operated on with "open" surgery, with the exclusion of percutaneous valve repair/implantation procedures. RESULTS: The patients of the two groups (group 98-08-127 patients, and group 09-21-101 patients) had comparable preoperative risk factors in terms of the LogEuroSCORE (98-08: 21.3 ± 6.1 vs. 09-21: 20.9 ± 11.1, p = 0.12). There was a considerable difference in the type of surgery (isolated valve, isolated coronary, and combined surgery, 46.5, 38.5, and 15% vs. 52, 13, and 35% in 98-08 and 09-21, respectively, p = 0.01). Analogous operating durations were recorded (cross-clamp time: 98-08: 46 ± 28 min vs. 09-21: 51 ± 28 min, p = 0.06). The number of packed bypasses was lower in 09-21 (1.3 ± 0.6 vs. 2.4 ± 1.2, p = 0.001). In the postoperative period, there was a statistically significant difference in the 30-day survival in favor of the "more recent" patients (98-08: 17 deaths (13.4%) versus 09-21: 6(5.9%); p = 0.001), also confirmed in the subgroups (12.2% vs. 0% in isolated coronary surgery, p < 0.001; and 12.3% vs. 0% in isolated valve surgery, p < 0.001). CONCLUSIONS: Accurate pre-, intra-, and post-operative evaluation/management to reduce biological impacts facilitate significant improvements in the outcomes in nonagenarian patients when compared to the results recorded in previous years.

17.
JACC Cardiovasc Interv ; 16(4): 396-411, 2023 02 27.
Artigo em Inglês | MEDLINE | ID: mdl-36858659

RESUMO

BACKGROUND: The optimal access route in patients with severe peripheral artery disease (PAD) undergoing transcatheter aortic valve replacement (TAVR) remains undetermined. OBJECTIVES: This study sought to compare clinical outcomes with transfemoral access (TFA), transthoracic access (TTA), and nonthoracic transalternative access (TAA) in TAVR patients with severe PAD. METHODS: Patients with PAD and hostile femoral access (TFA impossible, or possible only after percutaneous treatment) undergoing TAVR at 28 international centers were included in this registry. The primary endpoint was the propensity-adjusted risk of 30-day major adverse events (MAE) defined as the composite of all-cause mortality, stroke/transient ischemic attack (TIA), or main access site-related Valve Academic Research Consortium 3 major vascular complications. Outcomes were also stratified according to the severity of PAD using a novel risk score (Hostile score). RESULTS: Among the 1,707 patients included in the registry, 518 (30.3%) underwent TAVR with TFA after percutaneous treatment, 642 (37.6%) with TTA, and 547 (32.0%) with TAA (mostly transaxillary). Compared with TTA, both TFA (adjusted HR: 0.58; 95% CI: 0.45-0.75) and TAA (adjusted HR: 0.60; 95% CI: 0.47-0.78) were associated with lower 30-day rates of MAE, driven by fewer access site-related complications. Composite risks at 1 year were also lower with TFA and TAA compared with TTA. TFA compared with TAA was associated with lower 1-year risk of stroke/TIA (adjusted HR: 0.49; 95% CI: 0.24-0.98), a finding confined to patients with low Hostile scores (Pinteraction = 0.049). CONCLUSIONS: Among patients with PAD undergoing TAVR, both TFA and TAA were associated with lower 30-day and 1-year rates of MAE compared with TTA, but 1-year stroke/TIA rates were higher with TAA compared with TFA.


Assuntos
Ataque Isquêmico Transitório , Doença Arterial Periférica , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Resultado do Tratamento , Sistema de Registros
18.
Eur J Cardiothorac Surg ; 63(6)2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-36892446

RESUMO

OBJECTIVES: With the popularization of catheter-based mitral valve procedures, evaluating risk-specific differentiated clinical outcomes after contemporary mitral valve surgery is crucial. In this study, we assessed the operative results of minimally invasive mitral valve operations across different patient risk profiles and evaluated the value of EuroSCORE (ES) II predicted risk of mortality model for risk prediction, in the large cohort of Mini-Mitral International Registry (MMIR). METHODS: The MMIR database was used to analyse mini-mitral operations between 2015 and 2021. Patients were categorized as low (<4%), intermediate (4% to <8%), high (8% to <12%) and extreme risk (≥12%) according to ES II. The observed-to-expected mortality ratio was calculated for each risk group. RESULTS: A total of 6541 patients were included in the analysis. Of those, 5546 (84.8%) were classified as low risk, 615 (9.4%) as intermediate risk, 191 (2.9%) as high risk and 189 (2.9%) as extreme risk. Overall operative mortality and stroke rates were 1.7% and 1.4%, respectively, and were significantly associated with patient's risk. The observed mortality was significantly lower than expected-according to the ES II-in all risk categories (observed-to-expected ratio < 1). CONCLUSIONS: The present study provides an international contemporary benchmark for operative outcomes after minimally invasive mitral surgery. Operative results were excellent in low-, intermediate- and high-risk patients, but were less satisfactory in extreme risk. The ES II model overestimated the in-hospital mortality. We believe that findings from the MMIR may assist surgeons and cardiologists in clinical decision-making and treatment allocation for patients with mitral valve disease.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Doenças das Valvas Cardíacas , Implante de Prótese de Valva Cardíaca , Humanos , Valva Mitral/cirurgia , Procedimentos Cirúrgicos Cardíacos/métodos , Fatores de Risco , Esternotomia/métodos , Procedimentos Cirúrgicos Minimamente Invasivos/efeitos adversos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Estudos Retrospectivos , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/métodos
19.
Thorac Cardiovasc Surg ; 71(7): 557-565, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-36257545

RESUMO

OBJECTIVES: The aim of this study was to investigate the need for postoperative permanent pacemaker implantation (PPI) following sutureless and rapid-deployment aortic valve replacement (SuRD-AVR) in the context of a progress report from a large multicenter international registry (SURD-IR). METHODS: We retrospectively analyzed 4,166 patients who underwent SuRD-AVR between 2008 and 2019. The primary outcome was the need for PPI before discharge. The study population was analyzed separately according to the implanted prostheses (Su cohort and RD cohort). Each cohort was divided into two groups based on the operation date: an early group ("EG" = 2008-2016) and a late group ("LG" = 2017-2019). RESULTS: The rate of PPI decreased significantly in the Su cohort over time (EG = 10.8% vs LG = 6.3%, p < 0.001). In the Su cohort, a decrease in age, risk profile, and incidence of bicuspid aortic valve, increased use of anterior right thoracotomy, reduction of cardiopulmonary bypass time and of associated procedures, and more frequent use of smaller prostheses were observed over time. In the RD cohort, the rate of PPI was stable over time (EG = 8.8% vs LG = 9.3%, p = 0.8). In this cohort, a younger age, lower risk profile, and higher incidence of concomitant septal myectomy were observed over time. CONCLUSION: Our analysis showed a significant decrease in the PPI rate in patients who underwent Su-AVR over time. Patient selection as well as surgical improvements and a more accurate sizing could be correlated with this phenomenon. The RD cohort revealed no significant differences either in patient's characteristics or in PPI rate between the two time periods.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Procedimentos Cirúrgicos sem Sutura , Humanos , Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Estudos Retrospectivos , Relatório de Pesquisa , Resultado do Tratamento , Desenho de Prótese , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Procedimentos Cirúrgicos sem Sutura/efeitos adversos
20.
J Clin Med ; 13(1)2023 Dec 27.
Artigo em Inglês | MEDLINE | ID: mdl-38202159

RESUMO

BACKGROUND: Infective endocarditis (IE) is a serious disease, and in many cases, surgery is necessary. Whether the type of prosthesis implanted for aortic valve replacement (AVR) for IE impacts patient survival is a matter of debate. The aim of the present study is to quantify differences in long-term survival and recurrence of endocarditis AVR for IE according to prosthesis type among patients aged 40 to 65 years. METHODS: This was an analysis of the INFECT-REGISTRY. Trends in proportion to the use of mechanical prostheses versus biological ones over time were tested by applying the sieve bootstrapped t-test. Confounders were adjusted using the optimal full-matching propensity score. The difference in overall survival was compared using the Cox model, whereas the differences in recurrence of endocarditis were evaluated using the Gray test. RESULTS: Overall, 4365 patients were diagnosed and operated on for IE from 2000 to 2021. Of these, 549, aged between 40 and 65 years, underwent AVR. A total of 268 (48.8%) received mechanical prostheses, and 281 (51.2%) received biological ones. A significant trend in the reduction of implantation of mechanical vs. biological prostheses was observed during the study period (p < 0.0001). Long-term survival was significantly higher among patients receiving a mechanical prosthesis than those receiving a biological prosthesis (hazard ratio [HR] 0.546, 95% CI: 0.322-0.926, p = 0.025). Mechanical prostheses were associated with significantly less recurrent endocarditis after AVR than biological prostheses (HR 0.268, 95%CI: 0.077-0.933, p = 0.039). CONCLUSIONS: The present analysis of the INFECT-REGISTRY shows increased survival and reduced recurrence of endocarditis after a mechanical aortic valve prosthesis implant for IE in middle-aged patients.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA