Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
PLoS One ; 19(4): e0296357, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38578749

RESUMO

OBJECTIVE: Quantitative values derived from PET brain images are of high interest for neuroscientific applications. Insufficient DT correction (DTC) can lead to a systematic bias of the output parameters obtained by a detailed analysis of the time activity curves (TACs). The DTC method currently used for the Siemens 3T MR BrainPET insert is global, i.e., differences in DT losses between detector blocks are not considered, leading to inaccurate DTC and, consequently, to inaccurate measurements masked by a bias. However, following careful evaluation with phantom measurements, a new block-pairwise DTC method has demonstrated a higher degree of accuracy compared to the global DTC method. APPROACH: Differences between the global and the block-pairwise DTC method were studied in this work by applying several radioactive tracers. We evaluated the impact on [11C]ABP688, O-(2-[18F]fluoroethyl)-L-tyrosine (FET), and [15O]H2O TACs. RESULTS: For [11C]ABP688, a relevant bias of between -0.0034 and -0.0053 ml/ (cm3 • min) was found in all studied brain regions for the volume of distribution (VT) when using the current global DTC method. For [18F]FET-PET, differences of up to 10% were observed in the tumor-to-brain ratio (TBRmax), these differences depend on the radial distance of the maximum from the PET isocenter. For [15O]H2O, differences between +4% and -7% were observed in the GM region. Average biases of -4.58%, -3.2%, and -1.2% for the regional cerebral blood flow (CBF (K1)), the rate constant k2, and the volume of distribution VT were observed, respectively. Conversely, in the white matter region, average biases of -4.9%, -7.0%, and 3.8% were observed for CBF (K1), k2, and VT, respectively. CONCLUSION: The bias introduced by the global DTC method leads to an overestimation in the studied quantitative parameters for all applications compared to the block-pairwise method. SIGNIFICANCE: The observed differences between the two DTC methods are particularly relevant for research applications in neuroscientific studies as they affect the accuracy of quantitative Brain PET images.


Assuntos
Encéfalo , Oximas , Tomografia por Emissão de Pósitrons , Piridinas , Tomografia por Emissão de Pósitrons/métodos , Encéfalo/diagnóstico por imagem , Encéfalo/irrigação sanguínea , Imagens de Fantasmas , Cabeça , Imageamento por Ressonância Magnética
2.
Phys Med Biol ; 69(5)2024 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-38271724

RESUMO

Objective.ThephenoPET system is a plant dedicated positron emission tomography (PET) scanner consisting of fully digital photo multipliers with lutetium-yttrium oxyorthosilicate crystals and located inside a custom climate chamber. Here, we present the setup ofphenoPET, its data processing and image reconstruction together with its performance.Approach.The performance characterization follows the national electrical manufacturers association (NEMA) standard for small animal PET systems with a number of adoptions due to the vertical oriented bore of a PET for plant sciences. In addition temperature stability and spatial resolution with a hot rod phantom are addressed.Main results.The spatial resolution for a22Na point source at a radial distance of 5 mm to the center of the field-of-view (FOV) is 1.45 mm, 0.82 mm and 1.88 mm with filtered back projection in radial, tangential and axial direction, respectively. A hot rod phantom with18F gives a spatial resolution of up to 1.6 mm. The peak noise-equivalent count rates are 550 kcps @ 35.08 MBq, 308 kcps @ 33 MBq and 45 kcps @ 40.60 MBq for the mouse, rat and monkey size scatter phantoms, respectively. The scatter fractions for these phantoms are 12.63%, 22.64% and 55.90%. We observe a peak sensitivity of up to 3.6% and a total sensitivity of up toSA,tot= 2.17%. For the NEMA image quality phantom we observe a uniformity of %STD= 4.22% with ordinary Poisson maximum likelihood expectation-maximization with 52 iterations. Here, recovery coefficients of 0.12, 0.64, 0.89, 0.93 and 0.91 for 1 mm, 2 mm, 3 mm, 4 mm and 5 mm rods are obtained and spill-over ratios of 0.08 and 0.14 for the water-filled and air-filled inserts, respectively.Significance.ThephenoPET and its laboratory are now in routine operation for the administration of [11C]CO2and non-invasive measurement of transport and allocation of11C-labelled photoassimilates in plants.


Assuntos
Processamento de Imagem Assistida por Computador , Tomografia por Emissão de Pósitrons , Camundongos , Ratos , Animais , Tomografia por Emissão de Pósitrons/métodos , Imagens de Fantasmas
3.
Mol Imaging Biol ; 26(1): 36-44, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37848641

RESUMO

PURPOSE: Morphological imaging using MRI is essential for brain tumour diagnostics. Dynamic susceptibility contrast (DSC) perfusion-weighted MRI (PWI), as well as amino acid PET, may provide additional information in ambiguous cases. Since PWI is often unavailable in patients referred for amino acid PET, we explored whether maps of relative cerebral blood volume (rCBV) in brain tumours can be extracted from the early phase of PET using O-(2-18F-fluoroethyl)-L-tyrosine (18F-FET). PROCEDURE: Using a hybrid brain PET/MRI scanner, PWI and dynamic 18F-FET PET were performed in 33 patients with cerebral glioma and four patients with highly vascularized meningioma. The time interval from 0 to 2 min p.i. was selected to best reflect the blood pool phase in 18F-FET PET. For each patient, maps of MR-rCBV, early 18F-FET PET (0-2 min p.i.) and late 18F-FET PET (20-40 min p.i.) were generated and coregistered. Volumes of interest were placed on the tumour (VOI-TU) and normal-appearing brain (VOI-REF). The correlation between tumour-to-brain ratios (TBR) of the different parameters was analysed. In addition, three independent observers evaluated MR-rCBV and early 18F-FET maps (18F-FET-rCBV) for concordance in signal intensity, tumour extent and intratumoural distribution. RESULTS: TBRs calculated from MR-rCBV and 18F-FET-rCBV showed a significant correlation (r = 0.89, p < 0.001), while there was no correlation between late 18F-FET PET and MR-rCBV (r = 0.24, p = 0.16) and 18F-FET-rCBV (r = 0.27, p = 0.11). Visual rating yielded widely agreeing findings or only minor differences between MR-rCBV maps and 18F-FET-rCBV maps in 93 % of the tumours (range of three independent raters 91-94%, kappa among raters 0.78-1.0). CONCLUSION: Early 18F-FET maps (0-2 min p.i.) in gliomas provide similar information to MR-rCBV maps and may be helpful when PWI is not possible or available. Further studies in gliomas are needed to evaluate whether 18F-FET-rCBV provides the same clinical information as MR-rCBV.


Assuntos
Neoplasias Encefálicas , Glioma , Neoplasias Meníngeas , Humanos , Neoplasias Encefálicas/patologia , Glioma/patologia , Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons/métodos , Tirosina , Perfusão
4.
Front Neurosci ; 17: 1027697, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37766785

RESUMO

Introduction: The fMRI BOLD response to emotional stimuli highlighting the role of the medial prefrontal cortex (MPFC) has been thoroughly investigated. Recently, the relationship between emotion processing and GABA levels has been studied using MPFC proton magnetic resonance spectroscopy (1H-MRS). However, the role of GABAA receptors in the MPFC during emotion processing remains unexplored. Methods: Using [11C]flumazenil PET, we investigated the relationship between the binding potential of GABAA receptors and emotion processing as measured using simultaneous fMRI BOLD. We hypothesized a correlation between the percent signal change in the BOLD signal and the binding potential of GABAA receptors in the MPFC. In a combined simultaneous fMRI and [11C]flumazenil-PET study, we analyzed the data from 15 healthy subjects using visual emotional stimuli. Our task comprised two types of emotional processing: passive viewing and appraisal. Following the administration of a bolus plus infusion protocol, PET and fMRI data were simultaneously acquired in a hybrid 3 T MR-BrainPET. Results: We found a differential correlation of BOLD percent signal change with [11C]flumazenil binding potential in the MPFC. Specifically, [11C]flumazenil binding potential in the ventromedial prefrontal cortex (vMPFC) correlated with passive viewing of emotionally valenced pictures. In contrast, the [11C]flumazenil binding potential and the BOLD signal induced by picture appraisal did show a correlation in the paracingulate gyrus. Conclusion: Our data deliver first evidence for a relationship between MPFC GABAA receptors and emotion processing in the same region. Moreover, we observed that GABAA receptors appear to play different roles in emotion processing in the vMPFC (passive viewing) and paracingulate gyrus (appraisal).

5.
EJNMMI Res ; 13(1): 11, 2023 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-36757553

RESUMO

BACKGROUND: For positron emission tomography (PET) ligands, such as [11C]ABP688, to be able to provide more evidence about the glutamatergic hypothesis in schizophrenia (SZ), quantification bias during dynamic PET studies and its propagation into the estimated values of non-displaceable binding potential (BPND) must be addressed. This would enable more accurate quantification during bolus + infusion (BI) neuroreceptor studies and further our understanding of neurological diseases. Previous studies have shown BPND-related biases can often occur due to overestimated cerebellum activity (reference region). This work investigates whether an alternative framing scheme can minimize quantification biases propagated into BPND, whether confounders, such as smoking status, need to be controlled for during the study, and what the consequences for the data interpretation following analysis are. A group of healthy controls (HC) and a group of SZ patients (balanced and unbalanced number of smokers) were investigated with [11C]ABP688 and a BI protocol. Possible differences in BPND quantification as a function of smoking status were tested with constant 5 min ('Const 5 min') and constant true counts ('Const Trues') framing schemes. In order to find biomarkers for SZ, the differences in smoking effects were compared between groups. The normalized BPND and the balanced number of smokers and non-smokers for both framing schemes were evaluated. RESULTS: When applying F-tests to the 'Const 5 min' framing scheme, effect sizes (η2p) and brain regions which showed significant effects fluctuated considerably with F = 50.106 ± 54.948 (9.389 to 112.607), P-values 0.005 to < 0.001 and η2p = 0.514 ± 0.282 (0.238 to 0.801). Conversely, when the 'Const Trues' framing scheme was applied, the results showed much smaller fluctuations with F = 78.038 ± 8.975 (86.450 to 68.590), P < 0.001 for all conditions and η2p = 0.730 ± 0.017 (0.742 to 0.710), and regions with significant effects were more robustly reproduced. Further, differences, which would indicate false positive identifications between HC and SZ groups in five brain regions when using the 'Const 5 min' framing scheme, were not observed with the 'Const Trues' framing. CONCLUSIONS: Based on an [11C]ABP688 PET study in SZ patients, the results show that non-consistent BPND outcomes can be propagated by the framing scheme and that potential bias can be minimized using 'Const Trues' framing.

6.
Phys Med Biol ; 68(2)2023 01 05.
Artigo em Inglês | MEDLINE | ID: mdl-36595256

RESUMO

Objective. The positron range is a fundamental, detector-independent physical limitation to spatial resolution in positron emission tomography (PET) as it causes a significant blurring of underlying activity distribution in the reconstructed images. A major challenge for positron range correction methods is to provide accurate range kernels that inherently incorporate the generally inhomogeneous stopping power, especially at tissue boundaries. In this work, we propose a novel approach to generate accurate three-dimensional (3D) blurring kernels both in homogenous and heterogeneous media to improve PET spatial resolution.Approach. In the proposed approach, positron energy deposition was approximately tracked along straight paths, depending on the positron stopping power of the underlying material. The positron stopping power was derived from the attenuation coefficient of 511 keV gamma photons according to the available PET attenuation maps. Thus, the history of energy deposition is taken into account within the range of kernels. Special emphasis was placed on facilitating the very fast computation of the positron annihilation probability in each voxel.Results. Positron path distributions of18F in low-density polyurethane were in high agreement with Geant4 simulation at an annihilation probability larger than 10-2∼ 10-3of the maximum annihilation probability. The Geant4 simulation was further validated with measured18F depth profiles in these polyurethane phantoms. The tissue boundary of water with cortical bone and lung was correctly modeled. Residual artifacts from the numerical computations were in the range of 1%. The calculated annihilation probability in voxels shows an overall difference of less than 20% compared to the Geant4 simulation.Significance. The proposed method is expected to significantly improve spatial resolution for non-standard isotopes by providing sufficiently accurate range kernels, even in the case of significant tissue inhomogeneities.


Assuntos
Elétrons , Poliuretanos , Tomografia Computadorizada por Raios X , Tomografia por Emissão de Pósitrons/métodos , Simulação por Computador , Imagens de Fantasmas
7.
Phys Med Biol ; 67(23)2022 12 02.
Artigo em Inglês | MEDLINE | ID: mdl-36356317

RESUMO

'Objective. Dead time correction (DTC) is an important factor in ensuring accurate quantification in PET measurements. This is currently often achieved using a global DTC method, i.e., an average DTC factor is computed. For PET scanners designed to image dedicated organs, e.g., those used in brain imaging or positron emission mammography (PEM), a substantial amount of the administered radioactivity is located outside of the PET field-of-view (FOV). This activity contributes to the dead time (DT) of the scintillation detectors. Moreover, the count rates of the individual scintillation detectors are potentially very inhomogeneous due to the specific irradiation of each detector, especially for combined MR/PET systems, where radiation shields cannot be applied. Approach: We have developed a block-pairwise DTC method for our Siemens 3T MR BrainPET insert by extending a previously published method that uses the delayed random coincidence count rate to estimate the DT in the individual scans and planes (i.e., scintillation pixel rings). The method was validated in decay experiments using phantoms with a homogenous activity concentration and with and without out-of-FOV activity. Based on a three-compartment phantom, we compared the accuracy and noise properties of the block-pairwise DTC and the global DTC method.Main results. The currently used global DTC led to a substantial positive bias in regions with high activity; the block-pairwise DTC resulted in substantially less bias. The noise level for the block-pairwise DTC was comparable to the global DTC and image reconstructions without any DTC. Finally, we tested the block-pairwise DTC with a data set obtained from volunteer measurements using the mGluR5 (metabotropic glutamate receptor subtype 5) antagonist [11C]ABP688. When the relative differences in activity concentrations obtained with global DTC and block-pairwise DTC for the ACC and the cerebellum GM were compared, the ratios differed by a factor of up to 1.4 at the beginning-when the first injection is administered as a bolus with high radioactivity.Significance. In this work, global DTC was shown to have the potential to introduce quantification bias, while better quantitation accuracy was achieved with the presented block-pairwise DTC method. The method can be implemented in all systems that use the delayed window technique and is particulary expected to improve the quantiation accuracy of dedicated brain PET scanners due to their geometry.'


Assuntos
Tomografia por Emissão de Pósitrons , Tomografia Computadorizada por Raios X , Humanos , Tomografia por Emissão de Pósitrons/métodos , Imagens de Fantasmas , Processamento de Imagem Assistida por Computador , Encéfalo/diagnóstico por imagem
8.
Transl Psychiatry ; 12(1): 6, 2022 01 10.
Artigo em Inglês | MEDLINE | ID: mdl-35013095

RESUMO

Currently, the metabotropic glutamate receptor 5 (mGluR5) is the subject of several lines of research in the context of neurology and is of high interest as a target for positron-emission tomography (PET). Here, we assessed the feasibility of using [11C]ABP688, a specific antagonist radiotracer for an allosteric site on the mGluR5, to evaluate changes in glutamatergic neurotransmission through a mismatch-negativity (MMN) task as a part of a simultaneous and synchronized multimodal PET/MR-EEG study. We analyzed the effect of MMN by comparing the changes in nondisplaceable binding potential (BPND) prior to (baseline) and during the task in 17 healthy subjects by applying a bolus/infusion protocol. Anatomical and functional regions were analyzed. A small change in BPND was observed in anatomical regions (posterior cingulate cortex and thalamus) and in a functional network (precuneus) after the start of the task. The effect size was quantified using Kendall's W value and was 0.3. The motor cortex was used as a control region for the task and did not show any significant BPND changes. There was a significant ΔBPND between acquisition conditions. On average, the reductions in binding across the regions were - 8.6 ± 3.2% in anatomical and - 6.4 ± 0.5% in the functional network (p ≤ 0.001). Correlations between ΔBPND and EEG latency for both anatomical (p = 0.008) and functional (p = 0.022) regions were found. Exploratory analyses suggest that the MMN task played a role in the glutamatergic neurotransmission, and mGluR5 may be indirectly modulated by these changes.


Assuntos
Tomografia por Emissão de Pósitrons , Receptor de Glutamato Metabotrópico 5 , Radioisótopos de Carbono , Eletroencefalografia , Humanos , Oximas , Piridinas
9.
Hum Brain Mapp ; 43(7): 2148-2163, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35076125

RESUMO

The glutamate and γ-aminobutyric acid neuroreceptor subtypes mGluR5 and GABAA are hypothesized to be involved in the development of a variety of psychiatric diseases. However, detailed information relating to their in vivo distribution is generally unavailable. Maps of such distributions could potentially aid clinical studies by providing a reference for the normal distribution of neuroreceptors and may also be useful as covariates in advanced functional magnetic resonance imaging (MR) studies. In this study, we propose a comprehensive processing pipeline for the construction of standard space, in vivo distributions of non-displaceable binding potential (BPND ), and total distribution volume (VT ) based on simultaneously acquired bolus-infusion positron emission tomography (PET) and MR data. The pipeline was applied to [11 C]ABP688-PET/MR (13 healthy male non-smokers, 26.6 ± 7.0 years) and [11 C]Flumazenil-PET/MR (10 healthy males, 25.8 ± 3.0 years) data. Activity concentration templates, as well as VT and BPND atlases of mGluR5 and GABAA , were generated from these data. The maps were validated by assessing the percent error δ from warped space to native space in a selection of brain regions. We verified that the average δABP  = 3.0 ± 1.0% and δFMZ  = 3.8 ± 1.4% were lower than the expected variabilities σ of the tracers (σABP  = 4.0%-16.0%, σFMZ  = 3.9%-9.5%). An evaluation of PET-to-PET registrations based on the new maps showed higher registration accuracy compared to registrations based on the commonly used [15 O]H2 O-template distributed with SPM12. Thus, we conclude that the resulting maps can be used for further research and the proposed pipeline is a viable tool for the construction of standardized PET data distributions.


Assuntos
Tomografia por Emissão de Pósitrons , Receptores de GABA-A , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Mapeamento Encefálico/métodos , Humanos , Imageamento por Ressonância Magnética , Masculino , Tomografia por Emissão de Pósitrons/métodos , Receptores de GABA-A/metabolismo , Ácido gama-Aminobutírico/metabolismo
10.
IEEE Trans Med Imaging ; 41(5): 1104-1113, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34860648

RESUMO

Simultaneous MR-PET/-SPECT is an emerging technology that capitalises on the invaluable advantages of both modalities, allowing access to numerous sensitive tracers and superior soft-tissue contrast alongside versatile functional imaging capabilities. However, to optimise these capabilities, concurrent acquisitions require the MRI antenna located inside the PET/SPECT field-of-view to be operated without compromising any aspects of system performance or image quality compared to the stand-alone instrumentation. Here, we report a novel gamma-radiation-transparent antenna concept. The end-fed J-shape antenna is particularly adept for hybrid ultra-high field MR-PET/-SPECT applications as it enables all highly attenuating materials to be placed outside the imaging field-of-view. Furthermore, this unique configuration also provides advantages in stand-alone MR applications by reducing the amount of coupling between the cables and the antenna elements, and by lowering the potential specific absorption rate burden. The use of this new design was experimentally verified according to the important features for both ultra-high field MRI and the 511 keV transmission scan. The reconstructed attenuation maps evidently showed much lower attenuation (  âˆ¼ 15 %) for the proposed array when compared to the conventional dipole antenna array since there were no high-density components. In MR, it was observed that the signal-to-noise ratio from the whole volume obtained using the proposed array was comparable to that acquired by the conventional array which was also in agreement with the simulation results. The unique feature, J-shape array, would enable simultaneous MR-PET/-SPECT experiments to be conducted without unduly compromising any aspects of system performance and image quality compared to the stand-alone instrumentation.


Assuntos
Imageamento por Ressonância Magnética , Tomografia por Emissão de Pósitrons , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons/métodos , Razão Sinal-Ruído , Tomografia Computadorizada de Emissão de Fóton Único
11.
IEEE Trans Med Imaging ; 40(7): 1852-1862, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33735076

RESUMO

The kinetic analysis of [Formula: see text]-FET time-activity curves (TAC) can provide valuable diagnostic information in glioma patients. The analysis is most often limited to the average TAC over a large tissue volume and is normally assessed by visual inspection or by evaluating the time-to-peak and linear slope during the late uptake phase. Here, we derived and validated a linearized model for TACs of [Formula: see text]-FET in dynamic PET scans. Emphasis was put on the robustness of the numerical parameters and how reliably automatic voxel-wise analysis of TAC kinetics was possible. The diagnostic performance of the extracted shape parameters for the discrimination between isocitrate dehydrogenase (IDH) wildtype (wt) and IDH-mutant (mut) glioma was assessed by receiver-operating characteristic in a group of 33 adult glioma patients. A high agreement between the adjusted model and measured TACs could be obtained and relative, estimated parameter uncertainties were small. The best differentiation between IDH-wt and IDH-mut gliomas was achieved with the linearized model fitted to the averaged TAC values from dynamic FET PET data in the time interval 4-50 min p.i.. When limiting the acquisition time to 20-40 min p.i., classification accuracy was only slightly lower (-3%) and was comparable to classification based on linear fits in this time interval. Voxel-wise fitting was possible within a computation time ≈ 1 min per image slice. Parameter uncertainties smaller than 80% for all fits with the linearized model were achieved. The agreement of best-fit parameters when comparing voxel-wise fits and fits of averaged TACs was very high (p < 0.001).


Assuntos
Neoplasias Encefálicas , Glioma , Adulto , Neoplasias Encefálicas/diagnóstico por imagem , Glioma/diagnóstico por imagem , Humanos , Cinética , Tomografia por Emissão de Pósitrons , Tirosina
12.
Cancers (Basel) ; 13(4)2021 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-33562803

RESUMO

Amino acid PET using the tracer O-(2-[18F]fluoroethyl)-L-tyrosine (FET) has attracted considerable interest in neurooncology. Furthermore, initial studies suggested the additional diagnostic value of FET PET radiomics in brain tumor patient management. However, the conclusiveness of radiomics models strongly depends on feature generalizability. We here evaluated the repeatability of feature-based FET PET radiomics. A test-retest analysis based on equivalent but statistically independent subsamples of FET PET images was performed in 50 newly diagnosed and histomolecularly characterized glioma patients. A total of 1,302 radiomics features were calculated from semi-automatically segmented tumor volumes-of-interest (VOIs). Furthermore, to investigate the influence of the spatial resolution of PET on repeatability, spherical VOIs of different sizes were positioned in the tumor and healthy brain tissue. Feature repeatability was assessed by calculating the intraclass correlation coefficient (ICC). To further investigate the influence of the isocitrate dehydrogenase (IDH) genotype on feature repeatability, a hierarchical cluster analysis was performed. For tumor VOIs, 73% of first-order features and 71% of features extracted from the gray level co-occurrence matrix showed high repeatability (ICC 95% confidence interval, 0.91-1.00). In the largest spherical tumor VOIs, 67% of features showed high repeatability, significantly decreasing towards smaller VOIs. The IDH genotype did not affect feature repeatability. Based on 297 repeatable features, two clusters were identified separating patients with IDH-wildtype glioma from those with an IDH mutation. Our results suggest that robust features can be obtained from routinely acquired FET PET scans, which are valuable for further standardization of radiomics analyses in neurooncology.

13.
PLoS One ; 16(1): e0245580, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33481896

RESUMO

Iterative image reconstruction is widely used in positron emission tomography. However, it is known to contribute to quantitation bias and is particularly pronounced during dynamic studies with 11C-labeled radiotracers where count rates become low towards the end of the acquisition. As the strength of the quantitation bias depends on the counts in the reconstructed frame, it can differ from frame to frame of the acquisition. This is especially relevant in the case of neuro-receptor studies with simultaneous PET/MR when a bolus-infusion protocol is applied to allow the comparison of pre- and post-task effects. Here, count dependent changes in quantitation bias may interfere with task changes. We evaluated the impact of different framing schemes on quantitation bias and its propagation into binding potential (BP) using a phantom decay study with 11C and 3D OP-OSEM. Further, we propose a framing scheme that keeps the true counts per frame constant over the acquisition time as constant framing schemes and conventional increasing framing schemes are unlikely to achieve stable bias values during the acquisition time range. For a constant framing scheme with 5 minutes frames, the BP bias was 7.13±2.01% (10.8% to 3.8%) compared to 5.63±2.85% (7.8% to 4.0%) for conventional increasing framing schemes. Using the proposed constant true counts framing scheme, a stabilization of the BP bias was achieved at 2.56±3.92% (3.5% to 1.7%). The change in BP bias was further studied by evaluating the linear slope during the acquisition time interval. The lowest slope values were observed in the constant true counts framing scheme. The constant true counts framing scheme was effective for BP bias stabilization at relevant activity and time ranges. The mean BP bias under these conditions was 2.56±3.92%, which represents the lower limit for the detection of changes in BP during equilibrium and is especially important in the case of cognitive tasks where the expected changes are low.


Assuntos
Radioisótopos de Carbono , Imageamento Tridimensional/métodos , Tomografia por Emissão de Pósitrons , Marcação por Isótopo , Imagens de Fantasmas
14.
Transl Psychiatry ; 11(1): 60, 2021 01 18.
Artigo em Inglês | MEDLINE | ID: mdl-33462192

RESUMO

The symbiosis of neuronal activities and glucose energy metabolism is reflected in the generation of functional magnetic resonance imaging (fMRI) and electroencephalography (EEG) signals. However, their association with the balance between neuronal excitation and inhibition (E/I-B), which is closely related to the activities of glutamate and γ-aminobutyric acid (GABA) and the receptor availability (RA) of GABAA and mGluR5, remains unexplored. This research investigates these associations during the resting state (RS) condition using simultaneously recorded PET/MR/EEG (trimodal) data. The trimodal data were acquired from three studies using different radio-tracers such as, [11C]ABP688 (ABP) (N = 9), [11C]Flumazenil (FMZ) (N = 10) and 2-[18F]fluoro-2-deoxy-D-glucose (FDG) (N = 10) targeted to study the mGluR5, GABAA receptors and glucose metabolism respectively. Glucose metabolism and neuroreceptor binding availability (non-displaceable binding potential (BPND)) of GABAA and mGluR5 were found to be significantly higher and closely linked within core resting-state networks (RSNs). The neuronal generators of EEG microstates and the fMRI measures were most tightly associated with the BPND of GABAA relative to mGluR5 BPND and the glucose metabolism, emphasising a predominance of inhibitory processes within in the core RSNs at rest. Changes in the neuroreceptors leading to an altered coupling with glucose metabolism may render the RSNs vulnerable to psychiatric conditions. The paradigm employed here will likely help identify the precise neurobiological mechanisms behind these alterations in fMRI functional connectivity and EEG oscillations, potentially benefitting individualised healthcare treatment measures.


Assuntos
Mapeamento Encefálico , Imageamento por Ressonância Magnética , Encéfalo/diagnóstico por imagem , Eletroencefalografia , Tomografia por Emissão de Pósitrons
15.
Hum Brain Mapp ; 42(13): 4122-4133, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-30367727

RESUMO

Simultaneous trimodal positron emission tomography/magnetic resonance imaging/electroencephalography (PET/MRI/EEG) resting state (rs) brain data were acquired from 10 healthy male volunteers. The rs-functional MRI (fMRI) metrics, such as regional homogeneity (ReHo), degree centrality (DC) and fractional amplitude of low-frequency fluctuations (fALFFs), as well as 2-[18F]fluoro-2-desoxy-d-glucose (FDG)-PET standardised uptake value (SUV), were calculated and the measures were extracted from the default mode network (DMN) regions of the brain. Similarly, four microstates for each subject, showing the diverse functional states of the whole brain via topographical variations due to global field power (GFP), were estimated from artefact-corrected EEG signals. In this exploratory analysis, the GFP of microstates was nonparametrically compared to rs-fMRI metrics and FDG-PET SUV measured in the DMN of the brain. The rs-fMRI metrics (ReHO, fALFF) and FDG-PET SUV did not show any significant correlations with any of the microstates. The DC metric showed a significant positive correlation with microstate C (rs  = 0.73, p = .01). FDG-PET SUVs indicate a trend for a negative correlation with microstates A, B and C. The positive correlation of microstate C with DC metrics suggests a functional relationship between cortical hubs in the frontal and occipital lobes. The results of this study suggest further exploration of this method in a larger sample and in patients with neuropsychiatric disorders. The aim of this exploratory pilot study is to lay the foundation for the development of such multimodal measures to be applied as biomarkers for diagnosis, disease staging, treatment response and monitoring of neuropsychiatric disorders.


Assuntos
Córtex Cerebral , Conectoma/métodos , Rede de Modo Padrão , Eletroencefalografia/métodos , Imageamento por Ressonância Magnética/métodos , Imagem Multimodal/métodos , Tomografia por Emissão de Pósitrons/métodos , Adulto , Biomarcadores , Córtex Cerebral/diagnóstico por imagem , Córtex Cerebral/fisiologia , Rede de Modo Padrão/diagnóstico por imagem , Rede de Modo Padrão/fisiologia , Humanos
16.
Neuroimage ; 221: 117160, 2020 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-32679251

RESUMO

The use of hybrid PET/MR imaging facilitates the simultaneous investigation of challenge-related changes in ligand binding to neuroreceptors using PET, while concurrently measuring neuroactivation or blood flow with MRI. Having attained a steady state of the PET radiotracer using a bolus-infusion protocol, it is possible to observe alterations in ligand neuroreceptor binding through changes in distribution volumes. Here, we present an iterative procedure for establishing an administration scheme to obtain steady state [11C]flumazenil concentrations in grey matter in the human brain. In order to achieve a steady state in the shortest possible time, the bolus infusion ratio from a previous examination was adapted to fit the subsequent examination. 17 male volunteers were included in the study. Boli and infusions with different weightings were given to the subjects and were characterised by kbol values from 74 â€‹min down to 42 â€‹min. Metabolite analysis was used to ascertain the value of unmetabolised flumazenil in the plasma, and PET imaging was used to assess its binding in the grey matter. The flumazenil time-activity curves (TACs) in the brain were decomposed into activity contributions from pure grey and white matter and analysed for 12 â€‹vol of interest (VOIs). The curves highlighted a large variability in metabolic rates between the subjects, with kbol â€‹= â€‹54.3 â€‹min being a reliable value to provide flumazenil equilibrium conditions in the majority of the VOIs and cases. The distribution volume of flumazenil in all 12 VOIs was determined.


Assuntos
Radioisótopos de Carbono/administração & dosagem , Flumazenil , Moduladores GABAérgicos , Substância Cinzenta , Imageamento por Ressonância Magnética , Tomografia por Emissão de Pósitrons , Células Receptoras Sensoriais , Substância Branca , Adulto , Flumazenil/administração & dosagem , Flumazenil/sangue , Flumazenil/farmacocinética , Moduladores GABAérgicos/administração & dosagem , Moduladores GABAérgicos/sangue , Moduladores GABAérgicos/farmacocinética , Substância Cinzenta/diagnóstico por imagem , Substância Cinzenta/efeitos dos fármacos , Substância Cinzenta/metabolismo , Humanos , Masculino , Imagem Multimodal , Células Receptoras Sensoriais/efeitos dos fármacos , Células Receptoras Sensoriais/metabolismo , Substância Branca/diagnóstico por imagem , Substância Branca/efeitos dos fármacos , Substância Branca/metabolismo , Adulto Jovem
17.
Hum Brain Mapp ; 41(10): 2762-2781, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32150317

RESUMO

Consistent findings postulate disturbed glutamatergic function (more specifically a hypofunction of the ionotropic NMDA receptors) as an important pathophysiologic mechanism in schizophrenia. However, the role of the metabotropic glutamatergic receptors type 5 (mGluR5) in this disease remains unclear. In this study, we investigated their significance (using [11 C]ABP688) for psychopathology and cognition in male patients with chronic schizophrenia and healthy controls. In the patient group, lower mGluR5 binding potential (BPND ) values in the left temporal cortex and caudate were associated with higher general symptom levels (negative and depressive symptoms), lower levels of global functioning and worse cognitive performance. At the same time, in both groups, mGluR5 BPND were significantly lower in smokers (F[27,1] = 15.500; p = .001), but without significant differences between the groups. Our findings provide support for the concept that the impaired function of mGluR5 underlies the symptoms of schizophrenia. They further supply a new perspective on the complex relationship between tobacco addiction and schizophrenia by identifying glutamatergic neurotransmission-in particularly mGluR5-as a possible connection to a shared vulnerability.


Assuntos
Núcleo Caudado , Disfunção Cognitiva , Receptor de Glutamato Metabotrópico 5/metabolismo , Esquizofrenia , Lobo Temporal , Adulto , Núcleo Caudado/diagnóstico por imagem , Núcleo Caudado/metabolismo , Núcleo Caudado/fisiopatologia , Doença Crônica , Disfunção Cognitiva/etiologia , Disfunção Cognitiva/metabolismo , Disfunção Cognitiva/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Testes Neuropsicológicos , Oximas/farmacocinética , Tomografia por Emissão de Pósitrons , Piridinas/farmacocinética , Esquizofrenia/complicações , Esquizofrenia/metabolismo , Esquizofrenia/fisiopatologia , Fumar/metabolismo , Lobo Temporal/diagnóstico por imagem , Lobo Temporal/metabolismo , Lobo Temporal/fisiopatologia
18.
IEEE Trans Med Imaging ; 39(1): 140-151, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31180843

RESUMO

Accurate scatter correction is essential for qualitative and quantitative PET imaging. Until now, scatter correction based on Monte Carlo simulation (MCS) has been recognized as the most accurate method of scatter correction for PET. However, the major disadvantage of MCS is its long computational time, which makes it unfeasible for clinical usage. Meanwhile, single scatter simulation (SSS) is the most widely used method for scatter correction. Nevertheless, SSS has the disadvantage of limited robustness for dynamic measurements and for the measurement of large objects. In this work, a newly developed implementation of MCS using graphics processing unit (GPU) acceleration is employed, allowing full MCS-based scatter correction in clinical 3D brain PET imaging. Starting from the generation of annihilation photons to their detection in the simulated PET scanner, all relevant physical interactions and transport phenomena of the photons were simulated on GPUs. This resulted in an expected distribution of scattered events, which was subsequently used to correct the measured emission data. The accuracy of the approach was validated with simulations using GATE (Geant4 Application for Tomography Emission), and its performance was compared to SSS. The comparison of the computation time between a GPU and a single-threaded CPU showed an acceleration factor of 776 for a voxelized brain phantom study. The speedup of the MCS implemented on the GPU represents a major step toward the application of the more accurate MCS-based scatter correction for PET imaging in clinical routine.


Assuntos
Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons/métodos , Algoritmos , Neoplasias Encefálicas/diagnóstico por imagem , Desenho de Equipamento , Humanos , Imageamento Tridimensional/métodos , Método de Monte Carlo , Imagens de Fantasmas
20.
Eur Psychiatry ; 50: 7-20, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29358016

RESUMO

Simultaneous PET/MR/EEG (Positron Emission Tomography - Magnetic Resonance - Electroencephalography), a new tool for the investigation of neuronal networks in the human brain, is presented here within the framework of the European Union Project TRIMAGE. The trimodal, cost-effective PET/MR/EEG imaging tool makes use of cutting edge technology both in PET and in MR fields. A novel type of magnet (1.5T, non-cryogenic) has been built together with a PET scanner that makes use of the most advanced photodetectors (i.e., SiPM matrices), scintillators matrices (LYSO) and digital electronics. The combined PET/MR/EEG system is dedicated to brain imaging and has an inner diameter of 260 mm and an axial Field-of-View of 160 mm. It enables the acquisition and assessment of molecular metabolic information with high spatial and temporal resolution in a given brain simultaneously. The dopaminergic system and the glutamatergic system in schizophrenic patients are investigated via PET, the same physiological/pathophysiological conditions with regard to functional connectivity, via fMRI, and its electrophysiological signature via EEG. In addition to basic neuroscience questions addressing neurovascular-metabolic coupling, this new methodology lays the foundation for individual physiological and pathological fingerprints for a wide research field addressing healthy aging, gender effects, plasticity and different psychiatric and neurological diseases. The preliminary performances of two components of the imaging tool (PET and MR) are discussed. Initial results of the search of possible candidates for suitable schizophrenia biomarkers are also presented as obtained with PET/MR systems available to the collaboration.


Assuntos
Encéfalo/diagnóstico por imagem , Eletroencefalografia/métodos , Espectroscopia de Ressonância Magnética/métodos , Imagem Multimodal/métodos , Tomografia por Emissão de Pósitrons/métodos , Esquizofrenia/diagnóstico por imagem , Adulto , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA