Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 151
Filtrar
1.
Sensors (Basel) ; 24(9)2024 May 05.
Artigo em Inglês | MEDLINE | ID: mdl-38733040

RESUMO

Shoulder pain represents the most frequently reported musculoskeletal disorder, often leading to significant functional impairment and pain, impacting quality of life. Home-based rehabilitation programs offer a more accessible and convenient solution for an effective shoulder disorder treatment, addressing logistical and financial constraints associated with traditional physiotherapy. The aim of this systematic review is to report the monitoring devices currently proposed and tested for shoulder rehabilitation in home settings. The research question was formulated using the PICO approach, and the PRISMA guidelines were applied to ensure a transparent methodology for the systematic review process. A comprehensive search of PubMed and Scopus was conducted, and the results were included from 2014 up to 2023. Three different tools (i.e., the Rob 2 version of the Cochrane risk-of-bias tool, the Joanna Briggs Institute (JBI) Critical Appraisal tool, and the ROBINS-I tool) were used to assess the risk of bias. Fifteen studies were included as they fulfilled the inclusion criteria. The results showed that wearable systems represent a promising solution as remote monitoring technologies, offering quantitative and clinically meaningful insights into the progress of individuals within a rehabilitation pathway. Recent trends indicate a growing use of low-cost, non-intrusive visual tracking devices, such as camera-based monitoring systems, within the domain of tele-rehabilitation. The integration of home-based monitoring devices alongside traditional rehabilitation methods is acquiring significant attention, offering broader access to high-quality care, and potentially reducing healthcare costs associated with in-person therapy.


Assuntos
Dor de Ombro , Humanos , Dor de Ombro/reabilitação , Telerreabilitação/métodos , Dispositivos Eletrônicos Vestíveis , Qualidade de Vida , Ombro , Monitorização Fisiológica/métodos , Monitorização Fisiológica/instrumentação , Serviços de Assistência Domiciliar , Modalidades de Fisioterapia/instrumentação
2.
Sensors (Basel) ; 24(6)2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38544279

RESUMO

Respiratory rate (fR) monitoring through wearable devices is crucial in several scenarios, providing insights into well-being and sports performance while minimizing interference with daily activities. Strain sensors embedded into garments stand out but require thorough investigation for optimal deployment. Optimal sensor positioning is often overlooked, and when addressed, the quality of the respiratory signal is neglected. Additionally, sensor metrological characterization after sensor integration is often omitted. In this study, we present the design, development, and feasibility assessment of a smart t-shirt embedded with two flexible sensors for fR monitoring. Guided by a motion capture system, optimal sensor design and position on the chest wall were defined, considering both signal magnitude and quality. The sensors were developed, embedded into the wearable system, and metrologically characterized, demonstrating a remarkable response to both static (sensitivity 9.4 Ω⋅%-1 and 9.1 Ω⋅%-1 for sensor A and sensor B, respectively) and cyclic loads (min. hysteresis span 20.4% at 36 bpm obtained for sensor A). The feasibility of the wearable system was assessed on healthy volunteers both under static and dynamic conditions (such as running, walking, and climbing stairs). A mean absolute error of 0.32 bpm was obtained by averaging all subjects and tests using the combination of the two sensors. This value was lower than that obtained using both sensor A (0.53 bpm) and sensor B (0.78 bpm) individually. Our study highlights the importance of signal amplitude and quality in optimal sensor placement evaluation, as well as the characterization of the embedded sensors for metrological assessment.


Assuntos
Corrida , Dispositivos Eletrônicos Vestíveis , Humanos , Monitorização Fisiológica , Taxa Respiratória , Têxteis
3.
Sensors (Basel) ; 24(5)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38475147

RESUMO

The safeguarding of plant health is vital for optimizing crop growth practices, especially in the face of the biggest challenges of our generation, namely the environmental crisis and the dramatic changes in the climate. Among the many innovative tools developed to address these issues, wearable sensors have recently been proposed for monitoring plant growth and microclimates in a sustainable manner. These systems are composed of flexible matrices with embedded sensing elements, showing promise in revolutionizing plant monitoring without being intrusive. Despite their potential benefits, concerns arise regarding the effects of the long-term coexistence of these devices with the plant surface. Surprisingly, a systematic analysis of their influence on plant physiology is lacking. This study aims to investigate the effect of the color and geometric features of flexible matrices on two key plant physiological functions: photosynthesis and transpiration. Our findings indicate that the negative effects associated with colored substrates, as identified in recent research, can be minimized by holing the matrix surface with a percentage of voids of 15.7%. This approach mitigates interference with light absorption and reduces water loss to a negligible extent, making our work one of the first pioneering efforts in understanding the intricate relationship between plant wearables' features and plant health.


Assuntos
Transpiração Vegetal , Dispositivos Eletrônicos Vestíveis , Transpiração Vegetal/fisiologia , Fotossíntese/fisiologia , Fenômenos Fisiológicos Vegetais , Transporte Biológico , Água , Folhas de Planta/fisiologia
4.
Sensors (Basel) ; 24(2)2024 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-38257715

RESUMO

Accurately mapping the temperature during ablation is crucial for improving clinical outcomes. While various sensor configurations have been suggested in the literature, depending on the sensors' type, number, and size, a comprehensive understanding of optimizing these parameters for precise temperature reconstruction is still lacking. This study addresses this gap by introducing a tool based on a theoretical model to optimize the placement of fiber Bragg grating sensors (FBG) within the organ undergoing ablation. The theoretical model serves as a general framework, allowing for adaptation to various situations. In practical application, the model provides a foundational structure, with the flexibility to tailor specific optimal solutions by adjusting problem-specific data. We propose a nonlinear and nonconvex (and, thus, only solvable in an approximated manner) optimization formulation to determine the optimal distribution and three-dimensional placement of FBG arrays. The optimization aims to find a trade-off among two objectives: maximizing the variance of the expected temperatures measured by the sensors, which can be obtained from a predictive simulation that considers both the type of applicator used and the specific organ involved, and maximizing the squared sum of the distances between the sensor pairs. The proposed approach provides a trade-off between collecting diverse temperatures and not having all the sensors concentrated in a single area. We address the optimization problem through the utilization of approximation schemes in programming. We then substantiate the efficacy of this approach through simulations. This study tackles optimizing the FBGs' sensor placement for precise temperature monitoring during tumor ablation. Optimizing the FBG placement enhances temperature mapping, aiding in tumor cell eradication while minimizing damage to surrounding tissues.

5.
Sensors (Basel) ; 23(24)2023 Dec 12.
Artigo em Inglês | MEDLINE | ID: mdl-38139623

RESUMO

Nowadays, there is an ever-growing interest in assessing the collective intelligence (CI) of a team in a wide range of scenarios, thanks to its potential in enhancing teamwork and group performance. Recently, special attention has been devoted on the clinical setting, where breakdowns in teamwork, leadership, and communication can lead to adverse events, compromising patient safety. So far, researchers have mostly relied on surveys to study human behavior and group dynamics; however, this method is ineffective. In contrast, a promising solution to monitor behavioral and individual features that are reflective of CI is represented by wearable technologies. To date, the field of CI assessment still appears unstructured; therefore, the aim of this narrative review is to provide a detailed overview of the main group and individual parameters that can be monitored to evaluate CI in clinical settings, together with the wearables either already used to assess them or that have the potential to be applied in this scenario. The working principles, advantages, and disadvantages of each device are introduced in order to try to bring order in this field and provide a guide for future CI investigations in medical contexts.


Assuntos
Comunicação , Liderança , Humanos , Segurança do Paciente , Inteligência
6.
Bioengineering (Basel) ; 10(12)2023 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-38136000

RESUMO

The purpose of this study was to investigate how lateralization shoulder angle (LSA) and distalization shoulder angle (DSA) are related to clinical and kinematic outcomes after reverse total shoulder arthroplasty. Thirty-three patients were evaluated at least six months postoperatively. The Single Assessment Numeric Evaluation (SANE), Constant Murley Score (CMS), Simple Shoulder Test (SST), and Visual Analogue Scale (VAS) were used. Shoulder kinematics was evaluated with a stereophotogrammetric system. LSA and DSA inter-rater reliability was analysed through the interclass correlation coefficient (ICC). Stepwise forward linear regression analysis was conducted between LSA and DSA with clinical scales and kinematic measures, between which a correlation analysis was conducted. The inter-rater reliability for LSA (mean ICC = 0.93) and DSA (mean ICC = 0.97) results were good to excellent. Greater LSA values were associated with higher peaks of internal rotation (p = 0.012, R2 = 0.188) and range of motion (ROM) (p = 0.037, R2 = 0.133). SANE (p = 0.009), CMS (p = 0.031), and SST (0.026) were positively correlated to external rotation, while VAS (p = 0.020) was negatively related. Abduction peaks were positively related to CMS (p = 0.011) and SANE (p = 0.037), as well as abduction ROM (SANE, p = 0.031; CMS, p = 0.014).

7.
iScience ; 26(11): 108260, 2023 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-38026224

RESUMO

Thermal ablation of tumors aims to apply extreme temperatures inside the target tissue to achieve substantial tumor destruction in a minimally invasive manner. Several techniques are comprised, classified according to the type of energy source. However, the lack of treatment selectivity still needs to be addressed, potentially causing two risks: i) incomplete tumor destruction and recurrence, or conversely, ii) damage of the surrounding healthy tissue. Therefore, the research herein reviewed seeks to develop sensing systems based on fiber Bragg gratings (FBGs) for thermal monitoring inside the lesion during radiofrequency, laser, and microwave ablation. This review shows that, mainly thanks to multiplexing and minimal invasiveness, FBGs provide an optimal sensing solution. Their temperature measurements are the feedback to control the ablation process and allow to investigate different treatments, compare their outcomes, and quantify the impact of factors such as proximity to thermal probe and blood vessels, perfusion, and tissue type.

8.
Bioengineering (Basel) ; 10(11)2023 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-38002429

RESUMO

Few studies have evaluated the effectiveness of shoulder rehabilitation in virtual environments. The objective of this study was to investigate the performance of a custom virtual reality application (VR app) with a stereophotogrammetric system considered the gold standard. A custom VR app was designed considering the recommended rehabilitation exercises following arthroscopic rotator cuff repair. Following the setting of the play space, the user's arm length, and height, five healthy volunteers performed four levels of rehabilitative exercises. Results for the first and second rounds of flexion and abduction displayed low total mean absolute error values and low numbers of unmet conditions. In internal and external rotation, the number of times conditions were not met was slightly higher; this was attributed to a lack of isolated shoulder movement. Data is promising, and volunteers were able to reach goal conditions more often than not. Despite positive results, more literature comparing VR applications with gold-standard clinical parameters is necessary. Nevertheless, results contribute to a body of literature that continues to encourage the application of VR to shoulder rehabilitation programs.

9.
BMC Musculoskelet Disord ; 24(1): 859, 2023 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-37919702

RESUMO

BACKGROUND: Virtual Reality (VR) systems have been increasingly used across several medical fields. A crucial preliminary step for developing optimized VR-based applications for rehabilitation purposes is identifying potential interventions to meet the requirements necessary to satisfy end-users' needs. This study aims to assess the acceptability, usability, and appropriateness of a VR physical therapy program executed with Oculus Quest 2 by expert physiotherapists of shoulder musculoskeletal rehabilitation. METHODS: Eleven physiotherapists were enrolled to test a VR program for shoulder musculoskeletal rehabilitation. At the end of each session, physiotherapists completed three questionnaires about the acceptability, usability, and appropriateness of the VR system and application, investigating aspects such as wearability, safety, stability, ease of control, comfort, size, utility, playability, and use mode. RESULTS: The acceptability questionnaire revealed that all the physiotherapists found the VR system easy to wear and control, very confident, and safe. The usability questionnaire showed that most physiotherapists (73%) found the VR application entertaining, although only 45% said the system could be used independently by patients without the support of a therapist. Many physiotherapists found the use of the VR application appropriate for patients with rotator cuff tears treated conservatively (63.6%) or surgically (54.5%), for patients with shoulder osteoarthritis treated conservatively (72.7%), for patients with shoulder osteoarthritis after surgical treatment (63.6%). 91% of physiotherapists think it would be best for patients to use the VR system under the supervision of a therapist and not independently in a home setting. CONCLUSIONS: The use of VR in orthopaedic rehabilitation is encouraging, although further efforts are needed to increase the independent use of patients without the supervision of a physiotherapist. Moreover, future studies should strive to ensure the clinical effectiveness of VR rehabilitation in reaching therapeutic goal settings.


Assuntos
Osteoartrite , Realidade Virtual , Humanos , Ombro , Extremidade Superior , Modalidades de Fisioterapia
10.
Food Res Int ; 173(Pt 2): 113464, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37803787

RESUMO

The high population growth rate, massive animal food consumption, fast economic progress, and limited food resources could lead to a food crisis in the future. There is a huge requirement for dietary proteins including cultured meat is being progressed to fulfill the need for meat-derived proteins in the diet. However, production of cultured meat requires monitoring numerous bioprocess parameters. This review presents a comprehensive overview of various widely adopted techniques (optical, spectroscopic, electrochemical, capacitive, FETs, resistive, microscopy, and ultrasound) for monitoring physical, chemical, and biological parameters that can improve the bioprocess control in cultured meat. The methods, operating principle, merits/demerits, and the main open challenges are reviewed with the aim to support the readers in advancing knowledge on novel sensing systems for cultured meat applications.


Assuntos
Dieta , Carne , Animais , Proteínas de Carne
11.
BMC Musculoskelet Disord ; 24(1): 766, 2023 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-37770871

RESUMO

PURPOSE: Radiofrequency ablation is an increasingly used surgical option for ablation, resection and coagulation of soft tissues in joint arthroscopy. One of the major issues of thermal ablation is the temperature monitoring across the target areas, as cellular mortality is a direct consequence of thermal dosimetry. Temperatures from 45 °C to 50 °C are at risk of damage to chondrocytes. One of the most reliable tools for temperature monitoring is represented by fiber optic sensors, as they allow accurate and real-time temperature measurement via a minimally invasive approach. The aim of this study was to determine, by fiber Bragg grating sensors (FBGs), the safety of radiofrequency ablation in tissue heating applied to ex-vivo bovine hip joints. METHODS: Ex vivo bovine hips were subjected to radiofrequency ablation, specifically in the acetabular labrum, for a total of two experiments. The WEREWOLF System (Smith + Nephew, Watford, UK) was employed in high operating mode and in a controlled ablation way. One optical fiber embedding seven FBGs was used to record multipoint temperature variations. Each sensor was 1 mm in length with a distance from edge to edge with each other of 2 mm. RESULTS: The maximum variation was recorded in both the tests by the FBG1 (i.e., the closest one to the electrode tip) and was lower than to 2.8 °C. The other sensors (from FBG2 to FBG7) did not record a significant temperature change throughout the duration of the experiment (maximum up to 0.7 °C for FBG7). CONCLUSIONS: No significant increase in temperature was observed at any of the seven sites. The sensor nearest to the radiofrequency source exhibited the highest temperature rise, but the variation was only 3 °C. The minimal temperature increase registered at the measurement sites, according to existing literature, is not expected to be cytotoxic. FBGs demonstrate the potential to fulfil the strict requirements for temperature measurements during arthroscopic surgery.


Assuntos
Articulação do Quadril , Ablação por Radiofrequência , Humanos , Bovinos , Animais , Temperatura , Artroscopia , Condrócitos
12.
Sensors (Basel) ; 23(15)2023 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-37571723

RESUMO

Monitoring shoulder kinematics, including the scapular segment, is of great relevance in the orthopaedic field. Among wearable systems, magneto-inertial measurement units (M-IMUs) represent a valid alternative for applications in unstructured environments. The aim of this systematic literature review is to report and describe the existing methods to estimate 3D scapular movements through wearable systems integrating M-IMUs. A comprehensive search of PubMed, IEEE Xplore, and Web of Science was performed, and results were included up to May 2023. A total of 14 articles was included. The results showed high heterogeneity among studies regarding calibration procedures, tasks executed, and the population. Two different techniques were described, i.e., with the x-axis aligned with the cranial edge of the scapular spine or positioned on the flat surface of the acromion with the x-axis perpendicular to the scapular spine. Sensor placement affected the scapular motion and, also, the kinematic output. Further studies should be conducted to establish a universal protocol that reduces the variability among studies. Establishing a protocol that can be carried out without difficulty or pain by patients with shoulder musculoskeletal disorders could be of great clinical relevance for patients and clinicians to monitor 3D scapular kinematics in unstructured settings or during common clinical practice.


Assuntos
Articulação do Ombro , Dispositivos Eletrônicos Vestíveis , Humanos , Fenômenos Biomecânicos , Escápula , Ombro , Amplitude de Movimento Articular
13.
Sensors (Basel) ; 23(15)2023 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-37571742

RESUMO

The identification of respiratory patterns based on the movement of the chest wall can assist in monitoring an individual's health status, particularly those with neuromuscular disorders, such as hemiplegia and Duchenne muscular dystrophy. Thoraco-abdominal asynchrony (TAA) refers to the lack of coordination between the rib cage and abdominal movements, characterized by a time delay in their expansion. Motion capture systems, like optoelectronic plethysmography (OEP), are commonly employed to assess these asynchronous movements. However, alternative technologies able to capture chest wall movements without physical contact, such as RGB digital cameras and time-of-flight digital cameras, can also be utilized due to their accessibility, affordability, and non-invasive nature. This study explores the possibility of using a single RGB digital camera to record the kinematics of the thoracic and abdominal regions by placing four non-reflective markers on the torso. In order to choose the positions of these markers, we previously investigated the movements of 89 chest wall landmarks using OEP. Laboratory tests and volunteer experiments were conducted to assess the viability of the proposed system in capturing the kinematics of the chest wall and estimating various time-related respiratory parameters (i.e., fR, Ti, Te, and Ttot) as well as TAA indexes. The results demonstrate a high level of agreement between the detected chest wall kinematics and the reference data. Furthermore, the system shows promising potential in estimating time-related respiratory parameters and identifying phase shifts indicative of TAA, thus suggesting its feasibility in detecting abnormal chest wall movements without physical contact with a single RGB camera.


Assuntos
Parede Torácica , Humanos , Estudos de Viabilidade , Fenômenos Biomecânicos , Mecânica Respiratória , Respiração , Pletismografia/métodos
14.
Biomed Tech (Berl) ; 68(6): 563-571, 2023 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-37295779

RESUMO

This study aims compare the spatiotemporal and kinematic running parameters obtained by the WalkerView (Tecnobody, Bergamo, Italy) with those recorded by a optoelectronic 3D motion capture system. Seventeen participants were simultaneously recorded by the WalkerView and a motion capture system during running tests on the WalkerView at two different speeds (i.e., 8 km/h and 10 km/h). Per each parameter and speed the Root Mean Square Error (RMSE), the intraclass correlation coefficient (ICC), and the mean of the difference (MOD) and limits of agreement (LOAs) indexes obtained from Bland-Altman analysis were used to compare the two systems. ICCs show an excellent agreement for the mean step time and the cadence at both testing speeds (ICC=0.993 at 8 km/h; ICC=0.998 at 10 km/h); a lower agreement was found for all the kinematic variables. Small differences for some spatio-temporal parameters and greater differences for the kinematic variables were found. Therefore, WalkerView could represent a practical, accessible, and less expensive tool for clinicians, researchers, and sports trainers to assess the characteristics spatio-temporal parameters of running in non-laboratory settings.


Assuntos
Marcha , Corrida , Humanos , Fenômenos Biomecânicos , Teste de Esforço , Captura de Movimento , Reprodutibilidade dos Testes
15.
Biosensors (Basel) ; 13(6)2023 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-37367002

RESUMO

Emerging evidence suggests that respiratory frequency (fR) is a valid marker of physical effort. This has stimulated interest in developing devices that allow athletes and exercise practitioners to monitor this vital sign. The numerous technical challenges posed by breathing monitoring in sporting scenarios (e.g., motion artifacts) require careful consideration of the variety of sensors potentially suitable for this purpose. Despite being less prone to motion artifacts than other sensors (e.g., strain sensors), microphone sensors have received limited attention so far. This paper proposes the use of a microphone embedded in a facemask for estimating fR from breath sounds during walking and running. fR was estimated in the time domain as the time elapsed between consecutive exhalation events retrieved from breathing sounds every 30 s. Data were collected from ten healthy subjects (both males and females) at rest and during walking (at 3 km/h and 6 km/h) and running (at 9 km/h and 12 km/h) activities. The reference respiratory signal was recorded with an orifice flowmeter. The mean absolute error (MAE), the mean of differences (MOD), and the limits of agreements (LOAs) were computed separately for each condition. Relatively good agreement was found between the proposed system and the reference system, with MAE and MOD values increasing with the increase in exercise intensity and ambient noise up to a maximum of 3.8 bpm (breaths per minute) and -2.0 bpm, respectively, during running at 12 km/h. When considering all the conditions together, we found an MAE of 1.7 bpm and an MOD ± LOAs of -0.24 ± 5.07 bpm. These findings suggest that microphone sensors can be considered among the suitable options for estimating fR during exercise.


Assuntos
Taxa Respiratória , Corrida , Masculino , Feminino , Humanos , Sons Respiratórios , Respiração , Caminhada
16.
IEEE Trans Biomed Eng ; 70(5): 1673-1682, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37079397

RESUMO

Due to prolonged incorrect sitting posture, upper body musculoskeletal disorders (UBMDs) are largely widespread among sedentary workers. Monitoring employees' sitting behaviors could be of great help in minimizing UBMDs' occurrence. In addition, being primarily influenced by psycho-physical stress conditions, respiratory rate (RR) would be a further useful parameter to delineate the workers' state of health. Wearable systems have emerged as a viable option for sitting posture and RR monitoring since enable continuous data collecting with no posture disturbances. Nevertheless, the main limits are poor fit, cumbersomeness, and movement restriction resulting in discomfort for the user. In addition, only few wearable solutions can track both these parameters contextually. To address these problems, in this study a flexible wearable system composed of seven modular sensing elements based on fiber Bragg grating (FBG) technology and designed to be worn on the back has been proposed to recognize the most common sitting postures (i.e., kyphotic, upright and lordotic) and estimate RR. The assessment was performed on ten volunteers showing good performances in postures recognition via Naïve Bayes classificator (accuracy >96.9%) and agreement with the benchmark in RR estimation (MAPE ranging between 0.74% and 3.83%, MODs close to zero, and LOAs between 0.76 bpm and 3.63 bpm). The method was then successfully tested on three additional subjects under different breathing conditions. The wearable system could offer great support for a better understanding of the workers' posture attitudes and contribute to gathering RR information to depict an overall picture of the users' state of health.


Assuntos
Postura Sentada , Dispositivos Eletrônicos Vestíveis , Humanos , Taxa Respiratória , Teorema de Bayes , Postura
17.
IEEE Trans Biomed Eng ; 70(10): 2788-2798, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37027279

RESUMO

OBJECTIVE: A major concern with wearable devices aiming to measure the seismocardiogram (SCG) signal is the variability of SCG waveform with the sensor position and a lack of a standard measurement procedure. We propose a method to optimize sensor positioning based on the similarity among waveforms collected through repeated measurements. METHOD: we design a graph-theoretical model to evaluate the similarity of SCG signals and apply the proposed methodology to signals collected by sensors placed in different positions on the chest. A similarity score returns the optimal measurement position based on the repeatability of SCG waveforms. We tested the methodology on signals collected by using two wearable patches based on optical technology placed in two positions: mitral and aortic valve auscultation site (inter-position analysis). 11 healthy subjects were enrolled in this study. Moreover, we evaluated the influence of the subject's posture on waveform similarity with a view on ambulatory use (inter-posture analysis). RESULTS: the highest similarity among SCG waveforms is obtained with the sensor on the mitral valve and the subject lying down. CONCLUSIONS: our approach aims to be a step forward in the optimization of sensor positioning in the field of wearable seismocardiography. We demonstrate that the proposed algorithm is an effective method to estimate similarity among waveforms and outperforms the state-of-the-art in comparing SCG measurement sites. SIGNIFICANCE: results obtained from this study can be exploited to design more efficient protocols for SCG recording in both research studies and future clinical examinations.


Assuntos
Eletrocardiografia , Dispositivos Eletrônicos Vestíveis , Humanos , Eletrocardiografia/métodos , Tórax , Algoritmos , Frequência Cardíaca
18.
Biosensors (Basel) ; 13(3)2023 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-36979581

RESUMO

Given the importance of respiratory frequency (fR) as a valid marker of physical effort, there is a growing interest in developing wearable devices measuring fR in applied exercise settings. Biosensors measuring chest wall movements are attracting attention as they can be integrated into textiles, but their susceptibility to motion artefacts may limit their use in some sporting activities. Hence, there is a need to exploit sensors with signals minimally affected by motion artefacts. We present the design and testing of a smart facemask embedding a temperature biosensor for fR monitoring during cycling exercise. After laboratory bench tests, the proposed solution was tested on cyclists during a ramp incremental frequency test (RIFT) and high-intensity interval training (HIIT), both indoors and outdoors. A reference flowmeter was used to validate the fR extracted from the temperature respiratory signal. The smart facemask showed good performance, both at a breath-by-breath level (MAPE = 2.56% and 1.64% during RIFT and HIIT, respectively) and on 30 s average fR values (MAPE = 0.37% and 0.23% during RIFT and HIIT, respectively). Both accuracy and precision (MOD ± LOAs) were generally superior to those of other devices validated during exercise. These findings have important implications for exercise testing and management in different populations.


Assuntos
Exercício Físico , Máscaras , Taxa Respiratória , Respiração , Monitorização Fisiológica
19.
Sensors (Basel) ; 23(3)2023 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-36772656

RESUMO

Heart rate variability (HRV) indexes are becoming useful in various applications, from better diagnosis and prevention of diseases to predicting stress levels. Typically, HRV indexes are retrieved from the heart's electrical activity collected with an electrocardiographic signal (ECG). Heart-induced mechanical signals recorded from the body's surface can be utilized to record the mechanical activity of the heart and, in turn, extract HRV indexes from interbeat intervals (IBIs). Among others, accelerometers and gyroscopes can be used to register IBIs from precordial accelerations and chest wall angular velocities. However, unlike electrical signals, the morphology of mechanical ones is strongly affected by body posture. In this paper, we investigated the feasibility of estimating the most common linear and non-linear HRV indexes from accelerometer and gyroscope data collected with a wearable skin-interfaced Inertial Measurement Unit (IMU) positioned at the xiphoid level. Data were collected from 21 healthy volunteers assuming two common postures (i.e., seated and lying). Results show that using the gyroscope signal in the lying posture allows accurate results in estimating IBIs, thus allowing extracting of linear and non-linear HRV parameters that are not statistically significantly different from those extracted from reference ECG.


Assuntos
Coração , Parede Torácica , Humanos , Frequência Cardíaca/fisiologia , Eletrocardiografia , Postura
20.
Sensors (Basel) ; 23(1)2023 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-36617147

RESUMO

Wearable devices are widely spreading in various scenarios for monitoring different parameters related to human and recently plant health. In the context of precision agriculture, wearables have proven to be a valuable alternative to traditional measurement methods for quantitatively monitoring plant development. This study proposed a multi-sensor wearable platform for monitoring the growth of plant organs (i.e., stem and fruit) and microclimate (i.e., environmental temperature-T and relative humidity-RH). The platform consists of a custom flexible strain sensor for monitoring growth when mounted on a plant and a commercial sensing unit for monitoring T and RH values of the plant surrounding. A different shape was conferred to the strain sensor according to the plant organs to be engineered. A dumbbell shape was chosen for the stem while a ring shape for the fruit. A metrological characterization was carried out to investigate the strain sensitivity of the proposed flexible sensors and then preliminary tests were performed in both indoor and outdoor scenarios to assess the platform performance. The promising results suggest that the proposed system can be considered one of the first attempts to design wearable and portable systems tailored to the specific plant organ with the potential to be used for future applications in the coming era of digital farms and precision agriculture.


Assuntos
Microclima , Dispositivos Eletrônicos Vestíveis , Humanos , Temperatura , Monitorização Fisiológica/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA