1.
Clin Radiol ; 71(6): 615.e1-6, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27005016

RESUMO

AIM: To assess image quality and radiation dose in patients with body weights ≤75 kg undergoing abdominal computed tomography (CT) with a tube voltage of either 120 or 100 kVp. MATERIALS AND METHODS: Eighty patients weighing ≤75 kg were prospectively assigned to receive either 120 or 100 kVp abdominal CT in the portal-venous phase. Attenuation values of abdominal organs and image noise were measured, and the contrast-to-noise ratios (CNRs) were calculated. Subjective image quality was assessed by three independent radiologists. Radiation exposure was assessed by size-specific dose estimate (SSDE). RESULTS: The mean attenuation of the kidney increased by 20% at 100 kVp (p<0.0001), and the mean image noise was 27% higher in the 100 kVp (p=0.003). The CNR did not significantly differ between the groups (120 kVp, 6.6±2.8; 100 kVp, 7.4±3.6; p=0.26). Except for subjective image noise (p<0.001), no other subjective quality parameters (e.g., contrast, artefacts) were significantly different between the two groups (p between 0.094 and 0.761). The mean SSDE in the 100-kVp group (9.8±1.8 mGy) was reduced by 19% compared to the 120-kVp group (12.1±1.8 mGy; p<0.0001). CONCLUSION: Manual reduction of tube voltage from the standard 120 to 100 kVp for portal-venous phase CT in patients with body weights ≤75 kg resulted in a 19% dose reduction while maintaining objective and subjective image quality.


Assuntos
Peso Corporal , Tomografia Computadorizada Multidetectores/métodos , Doses de Radiação , Proteção Radiológica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Abdominal/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Radiometria/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
Clin Radiol ; 70(4): 366-72, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25554541

RESUMO

AIM: To compare low-contrast detectability, and qualitative and quantitative image parameters on standard and reduced radiation dose abdominal CT reconstructed with filtered back projection (FBP) and model-based iterative reconstruction (MBIR). MATERIALS AND METHODS: A custom built liver phantom containing 43 lesions was imaged at 120 kVp and four radiation dose levels (100% = 188 mAs, 50%, 25%, and 10%). Image noise and contrast-to-noise ratios (CNR) were assessed. Lesion detection and qualitative image analysis (five-point Likert scale with 1 = worst, 5 = best for confidence) was performed by three independent radiologists. RESULTS: CNR on MBIR images was significantly higher (mean 246%, range 151-383%) and image noise was significantly lower (69%, 59-78%) than on FBP images at the same radiation dose (both p < 0.05). On MBIR 10% images, CNR (3.3 ± 0.3) was significantly higher and noise (15 ± 1HU) significantly lower than on FBP 100% images (2.5 ± 0.1; 21 ± 1 HU). On 100% images, lesion attenuation was significantly lower with MBIR than with FBP (mean difference -2 HU). Low-contrast detectability and qualitative results were similar with MBIR 50% and FBP 100%. CONCLUSION: Low-contrast detectability with MBIR 50% and FBP 100% were equal. Quantitative parameters on even lower dose MBIR images are superior to 100%-dose FBP images. Some attenuation values differ significantly with MBIR compared with FBP.


Assuntos
Fígado/diagnóstico por imagem , Doses de Radiação , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Humanos , Imagens de Fantasmas , Reprodutibilidade dos Testes
3.
Clin Radiol ; 70(1): 54-61, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25459197

RESUMO

AIM: To compare image quality and diagnostic confidence of 100 kVp CT pulmonary angiography (CTPA) in patients with body weights (BWs) below and above 100kg. MATERIALS AND METHODS: The present retrospective study comprised 216 patients (BWs of 75-99kg, 114 patients; 100-125kg, 88 patients; >125kg, 14 patients), who received 100 kVp CTPA to exclude pulmonary embolism. The attenuation was measured and the contrast-to-noise ratio (CNR) was calculated in the pulmonary trunk. Size-specific dose estimates (SSDEs) were evaluated. Three blinded radiologists rated subjective image quality and diagnostic confidence. Results between the BW groups and between three body mass index (BMI) groups (BMI <25kg/m(2), BMI = 25-29.9kg/m(2), and BMI ≥30kg/m(2), i.e., normal weight, overweight, and obese patients) were compared using the Kruskal-Wallis test. RESULTS: Vessel attenuation was higher and SDDE was lower in the 75-99kg group than at higher BWs (p-values between <0.001 and 0.03), with no difference between the 100-125 and >125kg groups (p = 0.892 and 1). Subjective image quality and diagnostic confidence were not different among the BW groups (p = 0.225 and 1). CNR was lower (p < 0.006) in obese patients than in normal weight or overweight subjects. Diagnostic confidence was not different in the BMI groups (p = 0.105). CONCLUSION: CTPA at 100 kVp tube voltage can be used in patients weighing up to 125kg with no significant deterioration of subjective image quality and confidence. The applicability of 100 kVp in the 125-150kg BW range needs further testing in larger collectives.


Assuntos
Angiografia/normas , Sobrepeso/diagnóstico por imagem , Artéria Pulmonar/diagnóstico por imagem , Tomografia Computadorizada por Raios X/normas , Adulto , Idoso , Angiografia/métodos , Índice de Massa Corporal , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Obesidade/diagnóstico por imagem , Embolia Pulmonar/diagnóstico por imagem , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
4.
Clin Radiol ; 68(2): e79-86, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23219454

RESUMO

AIM: To assess the effect of an automatic tube voltage selection technique on image quality and radiation dose in abdominal computed tomography (CT) angiography of various body sizes. MATERIALS AND METHODS: An abdominal aortic phantom was filled with iodinated contrast medium and placed into three different cylindrical water containers, which simulated a small, intermediate-sized, and large patient. The phantom was scanned with a standard 120 kVp abdominal CT angiography protocol and with an optimized tube voltage protocol that was modulated by an automatic tube voltage technique. The attenuation of the aorta, background, and image noise was measured, and the contrast-to-noise ratio (CNR) was calculated. Three independent readers assessed the overall image quality. RESULTS: The automatic tube voltage technique selected 70 kVp as the optimal tube voltage for the small phantom, 80 kVp for the intermediate phantom, and 100 kVp for the large phantom. Compared to the standard 120 kVp protocol, the automatic tube voltage selection yielded significantly increased CNR values in the small phantom (15.8 versus 19.4, p < 0.001), intermediate phantom (8.4 versus 8.7, p < 0.05), and large phantom (4.3 versus 4.6, p < 0.01). The automatic tube voltage selection resulted in a 55%, 49%, and 39% reduction in the volume CT dose index (CTDI(vol)) in the small, intermediate, and large phantoms, respectively. The subjective overall image quality of the three phantom sizes at different tube voltages ranged between poor and good. CONCLUSION: Compared to a standard 120 kVp abdominal CT angiography protocol, the automatic tube voltage selection substantially reduced the radiation dose without compromising image quality in various simulated patient sizes.


Assuntos
Angiografia/métodos , Aorta Abdominal/diagnóstico por imagem , Imagens de Fantasmas , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/métodos , Automação , Tamanho Corporal , Humanos , Lesões por Radiação/prevenção & controle , Intensificação de Imagem Radiográfica , Interpretação de Imagem Radiográfica Assistida por Computador/instrumentação , Sensibilidade e Especificidade
5.
Eur J Radiol ; 81(9): 2007-13, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21696902

RESUMO

PURPOSE: To prospectively evaluate whether intravenous morphine co-medication improves bile duct visualization of dual-energy CT-cholangiography. MATERIALS AND METHODS: Forty potential donors for living-related liver transplantation underwent CT-cholangiography with infusion of a hepatobiliary contrast agent over 40 min. Twenty minutes after the beginning of the contrast agent infusion, either normal saline (n=20 patients; control group [CG]) or morphine sulfate (n=20 patients; morphine group [MG]) was injected. Forty-five minutes after initiation of the contrast agent, a dual-energy CT acquisition of the liver was performed. Applying dual-energy post-processing, pure iodine images were generated. Primary study goals were determination of bile duct diameters and visualization scores (on a scale of 0 to 3: 0--not visualized; 3--excellent visualization). RESULTS: Bile duct visualization scores for second-order and third-order branch ducts were significantly higher in the MG compared to the CG (2.9±0.1 versus 2.6±0.2 [P<0.001] and 2.7±0.3 versus 2.1±0.6 [P<0.01], respectively). Bile duct diameters for the common duct and main ducts were significantly higher in the MG compared to the CG (5.9±1.3 mm versus 4.9±1.3 mm [P<0.05] and 3.7±1.3 mm versus 2.6±0.5 mm [P<0.01], respectively). CONCLUSION: Intravenous morphine co-medication significantly improved biliary visualization on dual-energy CT-cholangiography in potential donors for living-related liver transplantation.


Assuntos
Absorciometria de Fóton/métodos , Colangiografia/métodos , Seleção do Doador/métodos , Transplante de Fígado/diagnóstico por imagem , Morfina/administração & dosagem , Tomografia Computadorizada por Raios X/métodos , Analgésicos Opioides/administração & dosagem , Ductos Biliares , Meios de Contraste/administração & dosagem , Feminino , Humanos , Aumento da Imagem/métodos , Injeções Intravenosas , Doadores Vivos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
6.
Radiologe ; 50(12): 1120, 1122-7, 2010 Dec.
Artigo em Alemão | MEDLINE | ID: mdl-20844858

RESUMO

The rapid technical advances in computed tomography have led to an increased number of clinical indications. Unfortunately, at the same time the radiation exposure to the population has also increased due to the increased total number of CT examinations. In the last few years various publications have demonstrated the feasibility of radiation dose reduction for CT examinations with no compromise in image quality and loss in interpretation accuracy. The majority of the proposed methods for dose optimization are easy to apply and are independent of the detector array configuration. This article reviews indication-dependent principles (e.g. application of reduced tube voltage for CT angiography, selection of the collimation and the pitch, reducing the total number of imaging series, lowering the tube voltage and tube current for non-contrast CT scans), manufacturer-dependent principles (e.g. accurate application of automatic modulation of tube current, use of adaptive image noise filter and use of iterative image reconstruction) and general principles (e.g. appropriate patient-centering in the gantry, avoiding over-ranging of the CT scan, lowering the tube voltage and tube current for survey CT scans) which lead to radiation dose reduction.


Assuntos
Angiografia/efeitos adversos , Angiografia/métodos , Processamento de Imagem Assistida por Computador/métodos , Doses de Radiação , Tomografia Computadorizada por Raios X/efeitos adversos , Tomografia Computadorizada por Raios X/métodos , Humanos , Radiometria/métodos , Tecnologia Radiológica/métodos
7.
Eur Surg Res ; 45(1): 26-33, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20720430

RESUMO

BACKGROUND/AIMS: To determine whether intravenous morphine comedication improves bile duct visualization, diameter and/or volume applying intravenous CT cholangiography in a porcine liver model. METHODS: 12 Landrace pigs underwent intravenous CT cholangiography. Eight minutes after initiation of the contrast material infusion, either morphine sulfate (n = 6 animals) or normal saline (n = 6 animals) was administered. Eighteen consecutive CT scans of the liver were acquired with 2-min intervals starting with initiation of the contrast material infusion. Maximum bile duct visualization scores, diameters and volumes and time to maximum bile duct visualization scores, diameters and volumes were determined. RESULTS: Maximum bile duct visualization scores, diameters and volumes and time to maximum bile duct visualization scores, diameters and volumes were not significantly different when the morphine group was compared to the normal saline group. Maximum bile duct visualization scores ranged between 4.00 ± 0.00 and 2.83 ± 1.47. Maximum bile duct diameters ranged between 6.77 ± 0.40 and 2.10 ± 1.35 mm. Maximum bile duct volume was 16.41 ± 7.33 ml in the morphine group and 16.79 ± 5.65 ml in the normal saline group. CONCLUSION: Intravenous morphine comedication failed to improve bile duct visualization and to increase bile duct diameter and volume applying CT cholangiography.


Assuntos
Morfina/administração & dosagem , Analgésicos Opioides/administração & dosagem , Animais , Colecistografia/métodos , Ducto Colédoco/anatomia & histologia , Ducto Colédoco/diagnóstico por imagem , Ducto Cístico/diagnóstico por imagem , Infusões Intravenosas , Radiografia Abdominal , Suínos , Tomografia Computadorizada por Raios X/métodos
8.
Skeletal Radiol ; 34(6): 355-8, 2005 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15891930

RESUMO

We present a case of chronic osteomyelitis in a 13-year-old girl which was originally diagnosed as adductor insertion avulsion syndrome ("thigh splints") on the basis of the clinical presentation, patient history, initial radiographs and MRI examination. However, at follow-up with persistent pain and altered radiographic and MRI appearances, surgical biopsy was indicated. Histopathological findings confirmed a bone abscess. This case underlines the necessity of clinical follow-up and imaging in certain patients with apparent thigh splints.


Assuntos
Fêmur/diagnóstico por imagem , Fêmur/patologia , Osteomielite/diagnóstico , Adolescente , Biópsia/métodos , Doença Crônica , Dermatite/complicações , Diagnóstico Diferencial , Feminino , Fêmur/microbiologia , Seguimentos , Humanos , Imageamento por Ressonância Magnética/métodos , Osteomielite/complicações , Osteomielite/tratamento farmacológico , Dor/etiologia , Radiografia , Infecções Estafilocócicas/diagnóstico , Infecções Estafilocócicas/tratamento farmacológico , Síndrome , Coxa da Perna/diagnóstico por imagem , Coxa da Perna/patologia
9.
Vasa ; 34(1): 62-5, 2005 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-15786943

RESUMO

We describe the successful selective coil embolization of an infected superior gluteal pseudoaneurysm secondary to methicillin-resistant Staphylococcus aureus (MRSA) in a 36-year old women. The patient presented with a long history of drug abuse and perisacral abscesses due to chronic sacroilitis. The chosen strategy provides a safe and successful management of infected false gluteal artery aneurysm.


Assuntos
Abscesso/complicações , Falso Aneurisma/terapia , Aneurisma Infectado/terapia , Artrite Infecciosa/complicações , Nádegas/irrigação sanguínea , Embolização Terapêutica , Resistência a Meticilina , Articulação Sacroilíaca , Infecções Estafilocócicas/terapia , Abscesso/diagnóstico , Adulto , Falso Aneurisma/diagnóstico , Aneurisma Infectado/diagnóstico , Angiografia , Artrite Infecciosa/diagnóstico , Bacteriemia/complicações , Bacteriemia/diagnóstico , Diagnóstico Diferencial , Feminino , Humanos , Imageamento por Ressonância Magnética , Infecções Estafilocócicas/diagnóstico , Tomografia Computadorizada por Raios X
10.
Skeletal Radiol ; 34(3): 156-60, 2005 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15232657

RESUMO

The rare occurrence of angiosarcoma in postmastectomy upper-limb lymphedema with magnetic resonance (MR) imaging is discussed. Unfamiliarity with this aggressive vascular tumor and its harmless appearance often leads to delayed diagnosis. Angiosarcoma complicating chronic lymphedema may be low in signal intensity on T2-weighting and short tau inversion recovery (STIR) imaging reflecting the densely cellular, fibrous stroma, and sparsely vascularized tumor histology. Additional administration of intravenous contrast medium revealed significant enhancement of the tumorous lesions. Awareness of angiosarcoma and its MR imaging appearance in patients with chronic lymphedema may be a key to early diagnosis or allow at least inclusion in the differential diagnosis.


Assuntos
Linfangiossarcoma/diagnóstico , Linfedema/complicações , Imageamento por Ressonância Magnética/métodos , Neoplasias Cutâneas/diagnóstico , Idoso de 80 Anos ou mais , Braço , Neoplasias da Mama/radioterapia , Neoplasias da Mama/cirurgia , Doença Crônica , Diagnóstico Diferencial , Feminino , Humanos , Linfangiossarcoma/etiologia , Mastectomia/efeitos adversos , Neoplasias Cutâneas/etiologia , Síndrome